Heating Controls Technical

Similar documents
CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

Wired Solutions Wired Heating Control Products

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Digital Room Thermostat

Electronic Dual Cylinder Thermostat Installation Instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Home. evohome multi-zone, Lyric T6 programmable thermostat and Single Zone thermostat. Smart Heating Controls THE COMPLETE CONNECTED CHOICE

RF Programmable Room Thermostat Installation Instructions

CentaurPlus ZW and HRT4-ZW

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

PRECISION CONTROL FROM MYSON PLUS

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

SMART THERMOSTAT WITH HOT WATER CONTROL

425 series Electro-mechanical Programmers

Operating your heating system with the Prefect PRE5701 Programable Thermostat

MAKING MODERN LIVING POSSIBLE. SET 1E Electronic Timeswitch for Heating and Hot Water. Installation Guide. Danfoss Heating

Installation and User Guide. Electro-mechanical 24 hour timeswitch for controlling hot water and heating (Including Factory Replacement Units FRU)

Smartfit S Pack Installation Guide with 24Hr or 7 Day Room Unit

ES3247B. 3 Channel Programmer. User and Installation Instructions

ESRTD2 Electronic Room Thermostat, with LCD Display

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

ESRTD3. Digital Room Thermostat with TPI & Delayed Start. User and Installation Instructions

T105 Advanced Remote Control Programmable Thermostat. User Manual

Honeywell Homes T3, T3M & T3R

WALL-HUNG HIGH EFFICIENCY GAS BOILERS. Elegant, efficient and intelligent

MAKING MODERN LIVING POSSIBLE. SET 3E Electronic 24 Hour Programmer for Heating and Hot Water. Installation Guide. Danfoss Heating

PART NO. COMBUSTION AIR TERMINATION CAP

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

RT021 User and Installation Instructions

Room thermostat with 24-hour time switch and large LCD

Digital Electronic Thermostat With RF

WALL-HUNG HIGH EFFICIENCY GAS BOILERS

PART NO. COMBUSTION AIR CAP

Instruction FH-CWP Thermostat

Programmable Room Thermostat Installation Instructions

CS-11 LCD Timeswitch: Central Time Control of Multiple Thermostats

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

ARATON 2100 TX 1 AURATON 2100 TX. Advanced Remote Control Programmable Thermostat

Digital Electronic Thermostat With RF

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

DOMESTIC HOT WATER Follow operational sequence

AUTO CM CM USER GUIDE

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

Installation & User Instructions

Electronic timeswitch

PROGRAMMABLE 7-DAY RF THERMOSTAT

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

USERS GUIDE 24, 30. For installation guide see reverse of book

SCS311 / SCS317 Installation Instructions

Installation and User Guide. Electro-mechanical mini programmer for controlling hot water and heating Including Factory Replacement Units (FRU)

Easy-Stat. Wireless Programmable Room Thermostat Pt No

User Operating Instructions Horstmann 425 Tiara/Diadem Electro-mechanical Programmers

evohome Sundial pack Thermostat

PROGRAMMABLE 7-DAY THERMOSTAT

3 Channel Multi-Purpose Programmer User Instructions

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

Digimax 210. Programmable Thermostat Compatible with Maxi Controller. User Guide

Model: RT310. Installation Manual

A B C D E F G H I J K L M N O P Q R S T U V W X Y Z

ST9000 FAMILY OF TIMERS & PROGRAMMERS FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

Battery Powered Electronic Programmable Room Thermostat

CS027 User Instructions

Electronic Thermostat With RF

Phone: * Website: wiser.draytoncontrols.co.uk /DraytonHome

Technical Data Manual

AURATON 2005 / 2005 TX

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

Dec Wirsbo CoSy Radio. Installation and Operating Instructions

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

WALL-HUNG HIGH EFFICIENCY GAS COMBINATION BOILERS. Efficient, economical and easy

INSTALLATION AND USER INSTRUCTIONS TOWERCHRON QE1/QE2. WA-EKF 4042/05.01/S:MMS/D:Bau/00/00344/

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

RF Programmable Room Thermostat User Instructions

C-Stat 17-ZW User Instructions

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

User Manual THR842DUK Wireless Digital Thermostat

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Battery Powered Electronic Room Thermostat Cat. No. TRT033

CET B-RF Wireless Electronic Hot Water Cylinder Thermostat User & Installation Instructions

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Heat Link. Technical Guide

User Guide for EHE & EHE Programmable Room Thermostat

Control Packs Catalogue. Including control packs compliant with 2013 Building Regulations: Part L

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

Alpha CombiMax 350 and 600

PART NO. THROUGH THE ROOF VENT CAP

THERMOMAX COLTREC RCX 100 MICROPROCESSOR REFRIGERATION CONTROL SYSTEM ENGLISH.

USER GUIDE LOGIC HEAT H

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

iheat 25c iheat 30c iheat 35c

Home. Wired, wireless & connected heating controls Control, Comfort and Energy Efficiency

Transcription:

472 Room Thermostat Voltage Rating: 230V AC 50Hz Switch Rating: Terminal 3 10A resistive, 3A inductive Terminal 4 6A resistive, 2A inductive Single pole, double throw (SPDT) Temperature Setting Range: 10 to 30 C Thermal Differential: 0.5-1-0 C (at a heat ramp of 3 C per hour with heat anticipator connected) The KT6360BWHI is a mains voltage room thermostat designed to give automatic temperature control of domestic wet central heating systems. It can be used to directly switch a circulating pump or boiler, or to operate spring return and motor open/motor close zone valves. The KT6360BWHI can switch electrical heating loads up to 10A. The KT6360BWHI thermostat can also be used for cooling applications. A room thermostat must be located in a position with good air circulation at average ambient temperature, preferably on an inside wall about 1.2 to 1.5m from the floor. The thermostat must not be positioned in draughts, above a radiator or where it will be subject to localised heat gains from direct sunlight, water pipes or appliances. To obtain close temperature control the heat anticipator must be operational. This is achieved by wiring the unit as shown on the wiring diagram. There are two knockouts on the top of the cover and one knockout on each side for surface wiring. When mini-trunking is used it must be fitted firmly against the thermostat cover so that there is no gap between the cover and trunking. Dual diaphragm temperature sensing element Suitable for surface or switch box mounting Heat anticipator for close temperature control Indicator neon, illuminates on a call for heat 84 10 84 15 20 25 30 o C 37 Change-over contact switching Double insulated Earth wire parking terminal RFI suppression Large setting dial 4 3 2 1 Terminal 3: 10(3)A max. Terminal 4: 6(2)A max. HEATIG LOAD L 230V 50Hz.B.1. Switching contacts are shown in the normally open position i.e. no heat demand. 2. Typical heating loads: Motorised zone valve, pump, boiler.

473 technical hotline +44 (0)1268 563720 white wiring devices Electronic Timeswitch Single pole, double throw (SPDT) Switch Rating: 3(3)A Timing Accuracy: ±1 min/month Timing Resolution: Time of Day 1 minute Programme Times 10 minutes Ambient Operating Temperature: 0-50 C Power Reserve: Minimum 4 days Weight: 330g approx (including wall plate) Earthing: Double Insulated Battery Back-Up: Integral battery with built-in charging circuit Options KST6100CWHI 7 Day Single Channel timeswitch with up to three / periods a day. KST6100AWHI 24 Hour Single Channel time-switch with up to two / periods a day. KST6100CWHI is a 7 day single channel timeswitch that gives great flexibility offering up to three on/off switchings per day, additionally, each day could be programmed differently. Ideal for combi installations when the user has different heating needs from day to day or as a zone control on larger systems. Transfer of programming information from one day to the next is simplified by the provision of a copy button. KST6100AWHI is a 24 hour timeswitch with two on/off switching times per day. This unit can be used for combi boilers, added zones or any application where small electrical loads need switching. A hinged cover conceals the programming buttons when not in use, leaving only the two override buttons exposed. The front cover also carries abbreviated user instructions on the inside for permanent ready reference. Built-in battery back-up Built-in start-up programme Clear digital display Ease of operation Temporary or permanent over-ride facilities 12-hour time display with am/pm indication ST 6100 Simple change to 24 hour clock display Programme indicator lights Double insulated Extra hour facility for one, two or three hour boost or programme extension Earth wire parking terminal 145 KST6100CWHI and KST6100AWHI can be either surface or flush switch box mounted, for both of which fixing screws are supplied. The wiring sub-base has holes to suit single switch boxes and breakouts for surface and channelled wiring and mini-trunking. When wiring is completed the plug-in module is fitted onto the sub-base and secured by tightening the retaining screws. Clock 3 AMPS MAX L 230V~ 50...60Hz MAIS IPUT L 1 2 3 4 TIMED OUTPUTS 95 45 120 For a full range of corresponding products, see pages 65-66 in the product selector. otes 1. Suitable for potential free mains voltage switching. 2. If normal mains voltage is required link terminal L and 1. Minimum clearance Above wall plate Below wall plate Left/right of wall plate 40mm 100mm 10mm

474 Electronic Programmer Single pole, double throw (SPDT) Switch Rating: 3(3)A Timing Accuracy: ±1 min/month Timing Resolution: Time of Day 1 minute Programme Times 10 minutes Ambient Operating Temperature: 0-50 C Power Reserve: Minimum 4 days Weight: 330g approx (including wall plate) Earthing: Double Insulated Battery Back-Up: Integral battery with built-in charging circuit Options KST6400AWHI 24 hour full programmer with independent time control for heating and hot water. The KST6400AWHI can be either surface or flush switch box mounted, for which fixing screws are supplied. The wiring sub-base has holes to suit single switch boxes and breakouts for surface wiring and mini-trunking. When wiring is completed the plug-in module is fitted onto the sub-base and secured by tightening the retaining screws. The KST6400AWHI is a fully featured electronic programmer offering 24 hour programming with up to two / periods per day, which can be set independently for heating and hot water. A hinged cover conceals the programming buttons when not in use, leaving only the four override buttons exposed. The front cover also carries abbreviated user instructions on the inside for permanent ready reference. Independent time control of heating and hot water Up to three / periods a day Built-in start-up programme Clear digital display Ease of operation Temporary or permanent over-ride facilities ST 6400 Clock 3 AMPS MAX L 230V~ 50...60Hz L 1 2 3 4 HW CH HW TIMED OUTPUTS CH 12 hour time display with am/pm indication Simple change to 24 hour clock display Programme indicator lights Double insulated Extra hour facility for one, two or three hour boost or programme extension Earth wire parking terminal 145 95 45 120

475 technical hotline +44 (0)1268 563720 white wiring devices Single Pole, double throw (SPDT) Electric Rating: 230V~, 50 60Hz, 0.1A to 5A resistive 0.1A to 2A inductive (0.6pf) 24V~, 50 60Hz, 0.5A to 5A resistive 0.5A to A inductive (0.6pf) The WHI thermostat is designed to provide automatic time and temperature control of domestic heating systems. It can be used as part of a system in conjunction with combi-boilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The WHI is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product. Attractive slim, modern styling 24 hour heating program Up to 4 daily independent time and temperature level changes Room Temperature Enquiry EEPROM memory holds the user program indefinitely mode has an integral frost protection setting at minimum 5 o C (installer adjustable) so that pipes in the house will never freeze in winter Battery powered by 2 x AA size (LR6) alkaline cells Minimum battery life of 2 years with low battery warning indicator Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation o installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems

476 Location The WHI thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall, 1.5 metres above the floor level. Do not position the WHI thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. 88.5 133 26 175 Mounting The WHI thermostat can be mounted directly on the wall surface or on to an electrical wall box. The WHI thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class A switch (having contact separation of at least 3 mm in all poles).

477 technical hotline +44 (0)1268 563720 white wiring devices Single Pole, double throw (SPDT) Electric Rating: 230V~, 50 60Hz, 0.1A to 5A resistive 0.1A to 2A inductive (0.6pf) 24V~, 50 60Hz, 0.5A to 5A resistive 0.5A to A inductive (0.6pf) The WHI thermostat is designed to provide automatic time and temperature control of domestic heating systems. It can be used as part of a system in conjunction with combi- boilers, oil-burners and gas fired boilers, circulation pumps, thermal actuators, zone valves and electric heat systems (<5A). The WHI is designed with the installer in mind and includes a moulded back-plate with trunking guides and wiring breakouts to make installation quick and easy. The unit is ideal for consumers who want reliable precise temperature control from a modern looking, simple to program and easy to use product. Attractive slim, modern styling 7 day heating program Up to 4 daily independent time and temperature level changes Room Temperature Enquiry EEPROM memory holds the user program indefinitely mode has an integral frost protection setting at minimum 5 o C (installer adjustable) so that pipes in the house will never freeze in winter Battery powered by 2 x AA size (LR6) alkaline cells Minimum battery life of 2 years with low battery warning indicator Surface or wall box mounting options, with trunking guides and wiring breakouts to simplify installation o installer links or special installer switches on the back of the unit mean no adjustment is required for combi-boilers and most domestic central heating systems

478 Location The WHI thermostat is the control element of the heating system and, therefore, MUST be located in a position with good air circulation, at average room temperature and on an inside wall, 1.5 metres above the floor level. Do not position the WHI thermostat near sources of heat (radiators, hot air vents, TV or lights), near doors or windows, or in direct sunlight. 88.5 133 26 175 Mounting The WHI thermostat can be mounted directly on the wall surface or on to an electrical wall box. The WHI thermostat is designed for fixed wiring only and must be installed in accordance with the latest l.e.e. regulations. Ensure the wiring connection to the supply is via a fuse rated at no more than 5 amps and a Class A switch (having contact separation of at least 3 mm in all poles).