Electronic timeswitch

Similar documents
Room thermostat with 24-hour time switch and large LCD

Room thermostats with LCD RDD100..

Room thermostat with independent DHW control

Room thermostat with Auto Timer, independent DHW

Wireless room thermostat with LCD

Frost Protection Thermostat

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Room Temperature Controllers

Flush-mounted room thermostat

Semi flush-mount room thermostat with KNX communications For VAV heating and cooling systems

Flush-mounted room thermostats

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

Room thermostat with Auto Timer, Option External Input

Wall-mounted room thermostat with LCD

Mimic display driver, LED ribbon cable

Semi flush-mount room thermostats

Room Temperature Controller

Input module, input/output modules

Use. For 2-pipe fan coils

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Room thermostat with Auto Timer, Option External Input

Output module (230 V)

Interbases. Sinteso FDSB221, FDSB228, FDSB229

Multi line separator module

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

RVL479. Heating Controller. for use with a partner unit

Input module, input/output module

1592P01. for liquids in piping DN

Room thermostat with Auto Timer, Option External Input

Smart Thermostat RDS110

Frost Units for air temperature monitoring

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

Duct Temperature Sensors

Semi flush-mount communicating room thermostats

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

Call stations and extensions

Radio fire detection system

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

SOL-LX-W, SOL-LX-C, RoLP-LX, RoLP Sounder, beacon, and sounderbeacon

Room Temperature Sensors

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

Room thermostat with Auto Timer, Option External Input

FDOOT221, FDO221, FDT221

RAB21 RAB21.1. For two-pipe fan coils

QAW70. Room Unit. Building Technologies. for use with heating controllers

ASA linear smoke detector

ST9000 FAMILY OF TIMERS & PROGRAMMERS FEATURES APPLICATIONS PRODUCT SPECIFICATION SHEET

For the user / for the installer. Instructions for Use and Installation. time SWITCH hour time clock

RF Programmable Room Thermostat Installation Instructions

Room Sensor [RBT-3C] Installation Instructions

Fire control panels FC360

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

DM1131 / DM1133 / DM1134 Manual call points

OH720, OP720, HI720, HI722

FDOOT241-9, FDOOT241-A, FDO241, FDT241

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

FDM273 Radio manual call point Mounting

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

Electronic 7 Installation Instructions

Hot Water Switch installation instructions. Please pass to your installer

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

FDCIO223 (ES 45) Transponder

Fume Hood Operating Display Panel

SWING radio fire detection system

Digital Room Thermostat for Heating Applications with 7-Day Time Program

RVL480. Heating Controller

FP120-Z1 Power supply kit A (70 W) Technical Manual

RVL481. Heating Controller. including d.h.w. heating

Heating Element. Building Technologies HVAC Products

Heating and D.h.w. Controller RVL482 Basic Documentation

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Fire control panels FC726 FC726-XA

Room thermostats with LCD for wall mounting

REA22 Room Temperature Controller

Hot Water Switch installation instructions. Please pass to your installer

INSTALLATION INSTRUCTIONS

Semi flush-mount room thermostat

Indoor Air Quality Controller

FDOOT241-A9-Ex Multisensor fire detector

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

103E5. Installation & User Instructions. Electronic timeswitch for controlling hot water and heating. including Factory Replacement Units (FRU)

RE-PR3-E-27 3-Phase Panel Mount 27kW

Digital Room Thermostat

FT2080 Fire terminal (Touch) Mounting Installation

EN Operating manual. thermio TM eco QE1/QE2

CentaurPlus ZW and HRT4-ZW

FDCW241 Radio gateway Mounting

PRELIMINARY EDITION

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Touch Screen Flush-mount Room Thermostats with KNX Communications

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Heating Controls Technical

Electronic Thermostat With RF

Transcription:

Electronic timeswitch RWB1007 To control combination boilers and single zone applications together with the appropriate thermostat. Easy-to-read backlit display Time programming 7-day 2/3 ON/OFFs Advance and 1-hour boost Clock with auto summer/winter changeover Selectable time formats: 24-hour and 12-hour LED ON lamps Ideal for combination boilers Industry standard backplate Battery back-up Service interval capable Audio and visual service reminder 2017-11-27 Building Technologies

Use The RWB1007 electronic timeswitch is designed to control combination boilers and single zone applications together with the appropriate thermostat. Functions Service interval reminder function The boiler service interval reminder function complies with Regulation 36 of the Gas Safety (Installation and Use) Regulations 1998, requiring landlords to carry out a safety check at intervals of no more than 12 months. If the function is enabled, a message is displayed on screen, informing you about the number of days remaining until the next boiler service is due, up to 50 days prior to the actual service date (the prewarning period is set by the engineer, default is 50 days). Normal functions continue during this stage. The amount of prewarning days has to be entered by the installer, maintenance engineer, or the landlord. Contact them when you see the warning for the first time. From then, the display will switch between the normal display and the amount of remaining days. The RWB will also emit a 5-second sound hourly between 09:00 and 21:00. If the RWB goes past the service day, the system will be switched off with only the one-hour boost feature working, and the display will switch between the real time and OFF. Mechanical design The unit consists of the following parts: Plastic housing with electronics (inputs, outputs), operating elements (HMI) and DIP switches An industry standard backplate with screws 2

Operation and settings Switch 1: Programming switch. When all programming has been done, this switch must be in RUN. Switch 2: This switch allows you to choose how the RWB operates. 1. Constant: The RWB is permanently ON. 2. ALL DAY: The RWB switches on at the first ON and off at the last OFF. 3. AUTO: The RWB switches automatically at the programmed times. Boost: The RWB switches on for one hour if it is in an OFF period, or adds an hour if it is already in an ON period. Advance: The RWB brings forward the next ON or OFF period. This feature only works in AUTO or ALL DAY. Type summary Product number Stock number Description RWB1007 BPZ:RWB1007 Electronic timeswitch Equipment combinations Delivery When ordering, indicate the product number, stock number and description. Description Product number Data sheet *) Room thermostat RAA21 N3562 *) The documents can be downloaded from http://siemens.com/bt/download. Product documentation Topic Title Document ID Installation and commissioning RWB1007 User instructions A6V10464930 Standards and directives CE declarations 8000078260 Environmental compatibility Environmental declarations A6V101118376 3

Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download Notes Security CAUTION National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage Observe national provisions and comply with the appropriate safety regulations. Mounting NOTICE Do not install the unit where either extremes of heat or cold exist. Steam, water or oil cannot splash onto or enter the unit or its backplate. Installation NOTICE All external wiring must comply with current IEE regulations. Only competent electricians may wire this unit. Do not use this unit to control immersion heaters. Comply with local regulations to wire, protect and earth the unit. WARNING No internal line protection for supply lines to external consumers Risk of fire and injury due to short circuits! Adapt the line diameters as per local regulations to the rated value of the installed overcurrent protection device. The AC 230 V mains supply must have an external circuit breaker with a rated current of no more than 3 A. Commissioning Setting the On/Off times Before leaving the factory, the RWB1007 was programmed with the correct date and time with the following switching times dependent on the DIP switch setting on the back of RWB (factory default 2 On/Off). 4

Monday - Friday Weekend 2 On/Off switching times - On 06:00 Off 08:30 - On 16:30 Off 22:30 3 On/Off switching times - On 06:00 Off 08:30 - On 12:00 Off 14:00 - On 16:30 Off 22:30 2 On/Off switching times - On 07:00 Off 09:00 - On 16:30 Off 23:00 3 On/Off switching times - On 07:00 Off 09:00 - On 12:00 Off 14:00 - On 16:30 Off 23:00 NOTICE Press RESET after any DIP switch change. Time format The RWB1007 can display time in 24- or 12-hour format, with 24 hours as factory setting. To change the format, press the RESET button on the front of the unit, and set to the desired option. Maintenance The unit is designed for maintenance-free operation. Disposal The device is considered an electronic device for disposal in accordance with the European Guidelines and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Dispose of empty batteries in designated collection points. Instructions for the replacement of lithium button batteries WARNING Explosion due to fire or short-circuit, even with discharged battery Risk of injury due to flying parts Prevent the battery from coming into contact with water. Do not extinguish a burning battery with water. Do not recharge the battery. Do not damage or disassemble the battery. Do not heat the battery over 100 C. WARNING Leakage of electrolyte Severe burns Handle damaged batteries only wearing suitable protective gloves. In case of contact with electrolyte, rinse eyes immediately with plenty of water. Consult a doctor. Observe the following: 5

Use only a battery of the same type as a replacement. Observe the polarities (+/-). The battery must be new and undamaged. Store, transport and dispose of the battery in compliance with local requirements, regulations and laws. Also observe the instructions of the battery manufacturer. Warranty Technical data on specific applications are valid only together with Siemens products listed under "Equipment combinations". Siemens rejects any and all warranties in the event that thirdparty products are used. 6

Technical data Power supply Operating voltage AC 230 V Switching voltage AC 12 240 V Frequency 50 Hz Power consumption 50 ma Backup battery Type CR2032 lithium battery Life Min. 3 years Max. external supply line fusing: 3 A Outputs Contact rating - Resistive: max. 6 A - Inductive: max. 2 A Environmental conditions Moisture and dust ingress IP30 Operating humidity 20 80% r.h., 90% r.h. non-condensing Operating ambient temperature 0...50 Storage ambient temperature -20...60 Standards, directives and approvals EU conformity (CE) 8000078260 *) Safety class Housing as EN60730-2-7 standard as IEC 730 standard Environmental compatibility The product environmental declaration (A6V101118376 ) contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). * ) The documents can be downloaded from http://siemens.com/bt/download. General Connection terminals Housing Weight without/with packaging 2.0 mm dia. Fire retardant, ABS material 289 g/332.5 g 7

Diagrams Connection terminals L Live, AC 230 V N Neutral, AC 230 V 1 Switching input, hot water (HW) 2 Switching input, central heating (CH) 3 Switching output, hot water (HW), normally open (NO), voltage-free contact 4 Switching output, hot water (CH), normally open (NO), voltage-free contact Wiring diagrams Shutdown of heating ONLY when service due Shutdown of heating and hot water when service due Note: If AC 230 V direct mains switching is required, link L to 2. The voltage applied to terminal 2 is switched to terminal 4 when RWB is in the ON position. If wiring up as Service Interval Reminder for a combi-boiler, a new backplate supplied must be used. WARNING The mains supply must be isolated before replacing an existing timeswitch. Failure to do so may cause damage to the RWB and will invalidate any warranty claims. 8

Application examples Combination boiler 1 Combination boiler 2 Timeswitch, RWB 3 Room thermostat, RAA 4 Heating circuit Dimensions Dimensions in mm 9

Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 CH-6300 Zug Tel. +41 58 724 2424 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2017 Technical specifications and availability subject to change without notice. 10 Building Technologies Document ID 2017-11-27 Edition 2017-11-27