Fire control panels FC360

Similar documents
Fire control panels FC726 FC726-XA

FC722 Fire control panel

FC722 Fire control panel

FC724 Fire control panel

FC723 Fire control panel

FC724 Fire control panel

Fire control panel for modernization

FC2040. Fire control panel. Sinteso. FS20 series, MP6

FC2020 Fire control panel

FT2080 Fire terminal (Touch) Mounting Installation

FT2080 Fire terminal (Touch) Mounting Installation

Output module (230 V)

Input module, input/output modules

13 tones to choose from, 2 programmable alarm levels Adjustable sound levels up to 93 dba

Input module, input/output module

Mimic display driver, LED ribbon cable

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

FS20 Fire detection system

Multi line separator module

Manual call point. Sinteso Cerberus PRO FDM223H, FDM224H. 'Heavy Duty' manual call point addressed (FDnet/C-NET)

OOH740, OOHC740. Cerberus PRO. Automatic fire detectors

Sinteso TM product catalog.

Interbases. Sinteso FDSB221, FDSB228, FDSB229

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

OH720, OP720, HI720, HI722

DM1131 / DM1133 / DM1134 Manual call points

FDOOT241-9, FDOOT241-A, FDO241, FDT241

ASA linear smoke detector

DBS721, DBS729 Sounder interbase, Sounder beacon interbase

FDCL221-M Multi line separator module

DM1101 / DM1103 / DM1104 DM1103-L / DM1103-S Manual call points Manual release button and emergency stop button

FDF Sinteso Cerberus PRO Cerberus FIT. Flame detector. Flame detector addressed or collective, ASAtechnology TM

DC1154 / DC1154-AA / DC1156-AA / DC1157-AA Input / Output modules

FDOOT221, FDO221, FDT221

Cerberus FIT conventional system

FC700A Fire detection control unit

Manual call points. Sinteso / Cerberus PRO FDM225, FDM226

FP120-Z1 Power supply kit A (70 W) Technical Manual

OOH740, OOHC740 Automatic fire detectors

FDCIO223 (ES 45) Transponder

FDS229-R / FDS229-A Alarm sounder with supplementary optical indication

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

FS720 Fire detection system Planning

Radio fire detection system

Synova TM product catalog.

FDOOT241-A3, FDOOT241-A4, FDOOT241-A5, FDOOT241-A9, FDOOT241-8

FDBZ290 Air sampling smoke detection kit

SWING radio fire detection system

FC121-ZA / FC122-ZA / FC123-ZA / FC124-ZA

FDBZ290 Air sampling smoke detection kit

Call stations and extensions

DC1192 Input /Output module

Fire safety products and accessories siemens.com/cerberus

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

FDOOT241-A9-Ex Multisensor fire detector

DT1101A / DT1102A / DO110xA Automatic fire detectors

FDA241, FDA221 Siemens ASD

OOH740-A9-Ex Multisensor fire detector

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Building Technologies. FDUL221 en Line tester operating instructions for electricians

XC10 Extinguishing control panels

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

Test units and accessories

OOH740-A9-Ex Multi-sensor fire detector

FDCL221-Ex Line adapter (Ex)

Fire control panel detect 3004 plus and accessories

FC721 Fire control panel Technical Manual

ZXSe Range Data Sheet

Test units and accessories

FS720 Fire detection system (marine) Technical Manual

FDCW241 Radio gateway Mounting

2015 NEW. Cerberus ECO. enjoy protecting. Product Brouchure. siemens.com/buildingtechnologies

ZXSe Range. Fire Safety. Analogue addressable fire alarm control panel KEY FEATURES. Panel Features

FDA241, FDA221 Siemens ASD

Cerberus TM PRO Fire Safety System A comprehensive fire-protection system

Cerberus PRO A comprehensive fire-protection system

The EN54 Part 2 & 4 Fire System

DM1153H-Ex / DM1154H-Ex Manual call point 'Heavy Duty'-Ex

Room thermostat with 24-hour time switch and large LCD

System 800 Addressable Fire Detection & Alarm System

Discovery 4 Loop Analogue Addressable Control Panel (NVI & NVA series Protocols)

Product Data Sheet. Remote Terminals. Features:

MK8000 OPC Server Interface Specification for CS1115 Building Technologies

FDCW221 / DOW1171 / SMF121 SMF6120 (repair/replacement) Radio fire detection system

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

The EN54 Part 2, 4 and 13 Fire System

FDCL221 Line separator

Intelligent Security & Fire Ltd

INTELLIGENT FIRE ALARM CONTROL PANEL

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

Desigo TM Fire Safety System A comprehensive fire-protection system

ZSC100 Gas Detection and Alarm System Controller

Electronic timeswitch

DB110xA, DB1131A, SO620A, DB1151A Detector bases and accessories

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

DF1101-Ex Infrared flame detector

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

FDA241, FDA221 Aspirating Smoke Detector Technical Manual

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Desigo TM Fire Safety System A comprehensive fire-protection system

Transcription:

Cerberus TM FIT Fire control panels FC360 FC361-ZZ, FC361-ZA, FC361-YZ, FC361-YA Fire control panels (1-loop) for addressable peripheral devices with integrated operating unit One loop with 126 addresses or two stubs each with 32 addresses Two collective horn lines Three freely programmable relay outputs Four freely programmable control inputs/outputs Optional RS232 module Optional module with four freely configurable monitored outputs Integrated web-server-based 'FC360 Panel Configurator' software, access via Ethernet connection (port) Installation space for optional components: LED indicator (16 zones) Key switch (standard) or key switch (Nordic) Evacuation module (NL) Emergency power supply for emergency operating time of up to 72 hours Building Technologies 2016-06-13 Control Products and Systems

Properties The FC361-xx is a compact fire control panel with an integrated operating unit. An 'C-NET' detector line with up to 126 addressable devices can be connected on a single loop. It is also possible to connect up to two stub lines instead of a loop. Automatic fire detectors, manual call points, input/output modules, and other 'C-NET' devices can be connected to the detector line. You will find more information in the 'List of compatibility', document A6V10882301. The 'FC360 Panel Configurator' software is used to configure the fire control panel. All customer texts as well as individual zones and output controllers can be adapted with the 'FC360 Panel Configurator' software. Monitoring of the detector line for short-circuit and open line: Precision localization of the error location is possible. None of the devices on the detector line are lost in the event of a short-circuit on the loop. Up to 2000 events can be called up according to various criteria. Changeover to summer time and winter time is automatic. Individual customer text per zone containing up to 42 characters The 'Manned'/'Unmanned' operation modes can be selected. 2

Use Functions The FC361-xx is ideal for smaller fire detection installations such as those in the following buildings, for example: Workshops Hotels Schools Shops Residential homes Display and operating unit The following components are located on the operating unit: The electronic components for the operating unit Optional: Key switch (standard or Nordic) LED indicator (16 zones) Evacuation module (NL) No. Designation 1 Navigation button 2 Menu button 3 Keypad for entering numeric and alphanumeric texts, e.g., password, customer text, etc. 4 OK button (to confirm your selection) 5 C button ('Cancel') 6 Button for 'Buzzer OFF' 7 Button for 'Acknowledge' message 8 Button for 'Reset' message 9 'Mute'/'Unmute' button for sounder control 10 Button for 'Alarm delay OFF' 11 Button for 'Manned'/'Unmanned' operation modes 12 Button for scrolling through alarm messages 3

Mainboard The following components are located on the mainboard: A slot for the RS232 module CPU module An Ethernet port The connection terminals for the C-NET detector line (one loop or up to two stubs) Two monitored collective horn lines Three freely configurable relays (remote transmission fire fault, fire control) Four freely programmable control inputs/outputs One DC 24 V voltage output Optional: Output module (4M) equipped with 4 monitored freely configurable outputs for alarm devices, fire control, and transmission paths for alarm and fault Power supply 70 W The power supply feeds the hardware and charges the batteries. Emergency power supply In the event of a power cut, the batteries provide emergency current for up to 72 hours. Configuration Customer-specific adaptations to the system can be made with the integrated 'FC360 Panel Configurator'. 4

Design Configuration 8 9 1 2 3 7 7 6b 6a 5 4 4 Item Designation Type Notes 1 Housing Items 1 3 and item 7 2 Mainboard -> basic equipment for each FC361-xx 3 Power supply (70 W) FP2015-A1 4 Batteries FA200x-A1 2x 12 V 5 Key switch FCA3601-Z1 Optional 1, for access Key switch (Nordic) FCA3603-Z1 authorization for operation 6a LED indicator (16 zones) FTO3602-Z1 Optional 2 6b Evacuation module (NL) FTO3601-H1 Optional 2 7 PMI Basic equipment 8 Output module (4M) FCA3602-Z1 Optional 9 RS232 module (isolated) FCA2001-A1 Optional 1 Not in conjunction with the evacuation module (NL) 2 Either LED indicator (16 zones) or evacuation module (NL): The LED indicator (16 zones) and the evacuation module (NL) cannot be installed at the same time. 5

Type Overview Fire control panels FC361-xx FC361-ZZ S54433-C112-A1 Fire control panel (1L, Comp.) FC361-ZA S54433-C111-A1 Fire control panel (1L, Comf.) FC361-YZ S54433-C110-A1 Fire control panel (1L, Comp., LED) FC361-YA S54433-C109-A1 Fire control panel (1L, Comf., LED) FC361-ZZ Battery: Max. 2x 12 V, 12 Ah Without integrated LED indicator for 16 zones FC361-ZA Battery: Max. 2x 12 V, 25 Ah Without integrated LED indicator for 16 zones FC361-YZ Battery: Max. 2x 12 V, 12 Ah With integrated LED indicator for 16 zones FC361-YA Battery: Max. 2x 12 V, 25 Ah With integrated LED indicator for 16 zones Accessories Extensions FTO3602-Z1 S54433-B117-A1 LED indicator (16 zones) FCA3601-Z1 S54433-N113-A1 Key switch FCA3603-Z1 S54433-N115-A1 Key switch (Nordic) 6

FTO3601-H1 S54433-B116-A1 Evacuation module (NL) FCA2001-A1 A5Q00005327 RS232 module (isolated) FCA3602-Z1 S54433-A114-A1 Output module (4M) FCA1209-Z1 S54400-B124-A1 Output module (230 V) Auxiliary power supply FP120-Z1 S54400-S122-A1 Power supply kit A 70 W Batteries FA2003-A1 A5Q00019353 Battery (12 V, 7 Ah, VdS) FA2004-A1 A5Q00019354 Battery (12 V, 12 Ah, VdS) BAT12-25 S54302-Z102-A1 Battery (12 V, 25 Ah, VdS) External printer DL3750+ A5Q00023962 Matrix printer (external) A5Q00023963 Color ribbon for matrix printer DL3750+ Spare part FP2015-A1 S54400-B121-A1 Power supply (70 W) FCM3601-Z1 S54443-A115-A1 Mainboard FHD3601-Z1 S54443-B118-A1 Door incl. PMI Mounting accessories FHA3602-Z1 S54433-N118-A1 Semi-flush mount bezel Tools Type Order number/document ID Comment FC360 Panel Configurator Scope of supply for FC361- xx control panels FX3610 Cerberus FIT Quantities tool A6V10885143 7

Product documentation Document ID A6V10421795 A6V10450595 A6V10882301 A6V10421792 A6V10893024 Name Technical Manual of Fire Control Panels FC361-xx Operation Manual of FC360 Desktop Editor and FC360 Panel Configurator List of compatibility (for 'FC360' product line) Installation of Fire Control Panels FC361-xx Installation Semi flush mount bezel FHA3602-Z1 Technical data General data Number of detector lines Loop or Stub lines Max. 1 Max. 2 Number of addresses Max. 126 Operating unit Dimensions (W x H x D) FC361-ZZ / FC361-YZ FC361-ZA / FC361-YA Color: Housing / cover cap Integrated 402 x 372 x 132 mm 402 x 372 x 211 mm ~RAL 7035, light gray Inputs / outputs Integrated inputs/outputs Outputs for horn Relay outputs for fire control and transmission paths for alarm and fault Freely configurable inputs/outputs 4 Options: Output module (4M) with 4 monitored outputs for alarm devices, fire control, and transmission paths for alarm and fault 2 3 1 Connections Slot for serial interface RS232 Max. 1 Ethernet port RJ45 Max. 1 LED indication Max. 1 Key switch (standard) Max. 1 Key switch (Nordic) Max. 1 Evacuation module (NL) Max. 1 8

Connections Output card (4M) Max. 1 Connectable detector series External printer DL3750+ Cerberus PRO FD720 (C-NET) according to 'List of compatibility'. See 'Product documentation' section Connection via RS232 interface Performance data Mains voltage Power supply Operating voltage Operating current Battery capacity Battery bridging time Battery monitoring Mains supervision AC 97...127 V AC 196...253 V 70 W DC 20.5...28.6 V Max. 2.5 A Max. 2x 12 V, 12 Ah (FC361-ZZ, FC361-YZ) Max. 2x 12 V, 25 Ah (FC361-ZA, FC361-YA) Up to 72 h Yes Yes Ambient conditions and protection category Operating temperature -5...+40 C Storage temperature -20 +60 C Air humidity (no condensation permitted) 95 % rel. Protection category (IEC 60529) IP30 Standards and approvals Standards EN 54-2, EN 54-4, EN 54-13 Approvals: LPCB 531q/03 Siemens Switzerland Ltd, Gubelstrasse 22 16 0786 FC361-YA / FC361-YZ / FC361-ZA / FC361-ZZ CH-6301 Zug, Switzerland Technical data: see doc. A6V10421795 FC361 - Control and Indicating Equipment incl. FP2015-70W/24VDC Power Supply Equipment in fire detection and fire alarm systems installed in buildings 305/2011/EU (CPR): EN 54-2 / EN 54-4 ; 2014/30/EU (EMC): EN 50130-4 / EN 61000-6-3 ; 2014/35/EU (LVD): EN 60950-1 ; 2011/65/EU (RoHS): EN 50581 Declared performance and conformity can be seen in the Declaration of Performance and the EC Declaration of Conformity, which is obtainable via the Customer Support center: Tel. +49 89 9221-8000 or http://siemens.com/bt/download DoP No.: 0832-CPR-F1346; DoC No.: CED-FC361 9

Issued by Siemens Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd, 2014 Technical specifications and availability subject to change without notice. 10 Fire Safety Document ID 2016-06-13 Edition 2016-06-13