Similar documents
Flexomix A versatile range of modular air handling units

GOLD RX/HC. The air handling unit with a reversible heat pump. Ventilation, heating and cooling all in one

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Geniox. The next generation of air handling units

VENTILATION = WELL-BEING

LIVING. For heat recovery in multi-occupancy buildings with extract air ventilation. And excellent return on investment.

Mikael Börjesson Product manager. Commercial air handling units Ventilation functionality Building management system integration

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

Heat pump & cooling unit in one

Think System Solution to get it right first time

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

eq PRIME » ENERGY EFFICIENCY AND FLEXIBILITY STRAIGHT OUT OF THE BOX AIR COMFORT AIR TREATMENT AIR HANDLING UNITS

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Contents. Technical Description of the Air Handling Unit General, Specification Function, Functional Sections

Ventilation. Product Information

Product Brochure Low-profile air handling units ATpicco. Modular configuration with highly efficient energy recovery

Comfortable indoor climate regardless of the season

Whole Home Heat Recovery Ventilation

» WITH REGASORP ROTARY HEAT EXCHANGER

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

PFS Single stage axial fan The axial fan for modern boiler plants

PRODUCT RANGE POOL AIR HANDLING UNITS. Swimming pool and spa environmental control, heating, cooling and dehumidification

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

KOMFORT EC DB Suspended heat recovery air handling units

Vireo Fresh intelligence

DAIKIN Air Handling Unit Modular

Breathe Fresh Air at Home

Healthy, comfortable and energy-efficient ventilation

TopMaster Air Handling unit. Technical data

Underfloor Air Systems. How It s Different: Overhead vs. Underfloor Air Systems

Screw Compressors ESM Fixed Speed & VS Variable Speed

Indoor Air Quality Product Brochure.

L CONNECTION NETWORK Commercial Controls

Air handling unit. REC Temovex 400S-EC-RS. Experts on indoor climate in low-energy houses

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Flexit air handling units UNI 2, 3 og 4

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Guide for Air Treatment with Ozone for Restaurants and Commercial Kitchens

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Tunnel Fans. Facilitator Office

Introducing the RetroVent

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

COOLflow 4E PRODUCT RANGE

The PA 600LI Heat Recovery Ventilation unit has been designed to serve the following small scale applications

Indoor Air Quality Product Brochure.

COMPACT VENTILATION UNITS DUPLEX R5

DEMAND-CONTROLLED HOME VENTILATION

Demand-controlled Ventilation Leading edge products for demand-controlled ventilation

Gas condensing boiler UltraGas

Description of the functions, IQlogic

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Swegon CASA R85. Ventilation unit with rotary heat exchanger HOME VENTILATION

The New Sorption Rotary Heat Exchanger

Vision and Skyline Semi-custom Air Handlers

Flexit air handling units C2 and UNI 2, 3,4

Complete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks

Swegon CASA R120. Ventilation unit with rotary heat exchanger HOME VENTILATION

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

SWIMMING POOL AIR MANAGEMENT DanX

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

OVERVIEW and SYSTEM GUIDE. Swegon CASA. Residential ventilation for optimal operating economy and the greatest comfort.

The plug & play fresh Air Solution

Screw Compressors ESN Fixed Speed & VS 250 Variable Speed

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Product catalogue Air handling units. Easy and flexible solutions for any ventilation requirements

VERSO Air Handling Units

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

Double Skin Air Handling Units

PRINCIPLE FOR DEHUMIDIFYING CRAWL SPACES

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

LG VRF Systems. Air Conditioning Technologies

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

VERSO DOMEKT. Residential ventilation units m³/h. Non residential ventilation units m³/h

Your complete source of information on Venmar AVS air exchangers. Constructo: 1.0 / 1.5 / 2.0 Solo: 1.5 / 2.0 Duo: 1.2 / 1.4 / 1.9 HE: 1.3 / 1.8 / 2.

AIR DIFFUSION A COMPLETE RANGE OF CHILLED BEAMS FOR COMFORT AND FLEXIBILITY CHILLED BEAMS. iq Star Lyra II iq Star Stella Flexicool IQID

RoofVent Design Handbook

Zehnder Comfosystems. ComfoAir 180 Datasheet

The clean solution M-iQ. A TOTALLY NEW DEFINITION OF CLEANING TECHNOLOGY.

Swegon CASA W130. Ventilation unit with counter-flow plate heat exchanger HOME VENTILATION

HEX390. Balanced Pressure Ventilation with Heat Recovery. for healthy indoor air

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

VERSO Air Handling Units

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

DX SYSTEM HEAT RECOVERY ENHANCED BY DEMAND CONTROLLED VENTILATION

COTES ALL ROUND C35E-C35D

GreenMaster HP Exhaust air heat pump for residential properties

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Gas condensing boiler (wall mounted) TopGas

XXXXXXX EN 1704 INSTALLATION AND OPERATION MANUAL. Desiccant dryer Condair DA 65. Dehumidification and Drying

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Heat recovery unit RDKS

Air Handling Unit Airblock FG

A MEMBER OF MUHIBBAH ENGINEERING

Atlas Copco Oil-injected Rotary Screw Compressors GA 15-22/GA /GA VSD (11-30 kw/15-40 hp)

TELLUS. Complete HVAC substation for air handling, cooling, heating and hot tap water. Main benefits. General

LYRA » ENERGY EFFICIENT CASSETTE CHILLED BEAM AIR DIFFUSION LYRA

ClimaFläkt. Chillers and condensing units

Transcription:

Unbelievable but true! The market s most energy-efficient air handling unit

World class air handling VoltAir System air handling unit is the market s leading system for recovery of tempered air in buildings. The secret behind the exceptionally efficient recovery is a patented heat exchanger with unique properties that ensure long product life, optimal economy and low maintenance. The heat is transferred without the risk of odours and particles leaking between the supply air and exhaust air, which contributes to a healthy and pleasant indoor climate. VoltAir System air handling units have been installed in residential buildings, offices, schools, hospitals, health care institutions and industries with excellent references and results. The units are available for flows of 0. m/s and upwards. They can be delivered with integrated control equipment or ready-prepared with a connector block that easily connects to the control system used by your organisation. The unit has a simple design with few components and moving parts, making it exceptionally service-friendly. It can be delivered in flat packages to facilitate transport to the installation location. VoltAir System is a Swedish quality product. Un What is unique about VoltAir System? Can be delivered in flat packages for maximum flexibility. 0. The unit can be assembled onsite and adapted to the building s specific characteristics. This allows optimal utilisation of the available space in the building. Columns in the way? Low ceiling? No problem! 0. Efficient cooling recovery in summer.0. Highest heat recovery efficiency 90% combined with EC fans and minimal internal pressure drop --> lowest operating cost. 0. High heat recovery efficiency, even at very low temperatures. The heat exchanger is made of polycarbonate, which minimises the risk of freezing. 07. No heating coil necessary in many cases. be bu liev a tt ru ble e! Few components and moving parts results in long service intervals and low service costs. 09. No silencer is needed on the supply air side in many cases. 0. No transfer of odours between the supply and exhaust air.. Available with integrated controller or connector block with connected sensors and actuators. 08. Exhaust air o -6 C Exhaust air o C % RH Every drop of sea water contains approximately billion gold atoms Supply air o 8 C Outdoor air o -8 C At the heart of the VoltAir System are two series-connected cross-flow heat exchangers in polycarbonate. Energy is recovered from the building s exhaust air by feeding the supply and exhaust air crosswise over the heat exchanger. The supply and exhaust air are held completely separate, eliminating the risk of odour transfer. The system has a sturdy design with few moving parts, which means minimal maintenance costs.

The world s entire ant population weighs more than the world s entire human population. OUT IN High heat recovery efficiency and low power consumption lead to the lowest life cycle cost on the market VoltAir System s highly efficient energy recovery is based on two series-connected cross-flow heat exchangers in polycarbonate. Energy is recovered from the building s exhaust air by feeding the supply and exhaust air crosswise over the heat exchanger. The supply and exhaust air are held completely separate from each other, and the unit s internal pressure setup ensures that they remain separate. This prevents the transfer of odours, a common problem in installations with rotary technology where particles and odours can be transferred via leakage or if the rotor is contaminated. Large heat-conductive surfaces, highly efficient energy exchange be tween air flows and cross-flow serial connection of the heat exchangers ensure operational reliability and high efficiency all year round. A smart investment, no matter what the season VoltAir System s high efficiency makes it a sound investment and not only during the cold months when heating is required; it works just as well during the summer. During summer use, the cooler exhaust air can be used to cool the warmer supply air through transferring of energy from the warm outdoor air to the exhaust air. This is especially effective when combined with the function called free night cooling. In warm summer days the VoltAir System heat exchanger off-loads the building s cooling system and can reduce the temperature by several degrees. Properties that result in the lowest LCC Large filter areas and low air speeds provide low internal pressure drop. In combination with EC fans, this results in minimal SFPv values. Internal pressure drops are further minimised by bypass dampers on both the supply air side and the exhaust air side, which open up at warmer temperatures. These combined features result in the lowest LCC. By the time you finish reading this sentence, ten more people will have been born on the Earth. 90% able eliev! b n U true but heat recovery efficiency without recirculating old air.

The song Happy Birthday is copyrighted. Hey, why don t we invest in a unit that also works in the winter? Un be l i but evabl e tru e! VoltAir System maintains its high heat recovery efficiency even at very low temperatures The heat exchanger in VoltAir System is made of polycarbonate that is specially processed to give it neutral static electricity characteristics and low surface roughness. This prevents dirt and ice from fastening on the surface of the heat exchanger, making the product highly resistant to ice accumulation. The heat exchanger s design with low air speeds, laminar flow and a 6 large heat-exchanging surface provides long periods of high efficiency without the need for defrosting. When the supply air temperature drops below zero, the moisture in the exhaust air freezes and forms ice crystals. The VoltAir System heat exchanger deals with this process and maintains its high efficiency even when ice starts forming. To prevent complete freezing in the event of unbalanced flows or during long periods with low outdoor temperatures, the units have an intelligent, automatic defrosting system that can be adapted to the prevailing conditions. Since the VoltAir System heat exchanger is so efficient and resistant to freezing, this automatic feature rarely needs to be activated, which translates into minimised heating costs. How does your existing air handling unit work? An HVAC unit s main task is to exchange indoor air for outdoor air. The air exchange process may be more or less energyefficient, and the long-term costs can vary greatly depending on the technology used. If your currently installed technology has a lower temperature efficiency than 80%, it is most likely more economical to switch to a unit with a higher recovery level. In the long run, the difference between 80% and 90% adds up to half your energy consumption. An LCC calculation clearly illustrates how much money you can save with VoltAir System.

TAIR tem The Earth s entire population would have room to live in an area the size of Texas. Low ceiling, difficult VOLTAIR access, System narrow no problem for VoltAir System A technical room usually cannot be rented out or utilised to the benefit of the property. For this reason, it is crucial to plan the premises so that the air handling system occupies as little space as possible. Early planning is no problem in a new building but it is often hard to fit a conventional air handling unit into older, pre-existing buildings. VoltAir System focuses on the customer s total economy. All surface area is a valuable resource that needs to be managed carefully. VoltAir System comes in a full range of versions and can be positioned anywhere. VoltAir System can ideally be installed in places that are narrow or difficult to access. Moreover, the technology even allows permanent obstacles such as columns to be built into the unit. The system can be installed in places that have low financial value such as attics, cellars, roofs or areas with low ceiling height. If necessary, the system can be installed through a standard door with an opening as narrow as 60 centimetres. This saves the customer added costs, e.g. for opening up walls, ceilings or roofs. VoltAir System frees up surface space, and many of our customer testimonials describe cases in which a former technical room was converted into flats, offices, spa facilities or other areas that could be used for financial gain. VOLTAIR SYSTEM System Unbelievable but true! 6 THANK TACK! YOU! TACK! TACK! OFF ON OFF ON 8 OFF ON 9

Dramatic energy savings, whichever size you choose Now it s even easier to choose a suitable unit and obtain information such as technical data, sketch drawings, energy and LCC calculations and optional accessories. The user-friendly unit selection programme can be downloaded from our website, www.voltairsystem.com, on the Documentation tab. www.voltairsystem.com VSEi Unit for indoor or outdoor installation VSEi has inspection hatches on the sides providing simple, practical service and maintenance access. The units can be located either indoors or outdoors. In the outdoor version, grilles are fitted on the exhaust and supply air outlets. The minimum permitted ceiling height is. metres for indoor installation. The more flexible product, VSI, can be customised for areas with even lower ceiling heights or with pillars. VSE compact AHU s 0, m /s -, m /s VSE is available in two models and can be installed on roofs, on facades, through facades or in technical rooms. The units can be supplied ready assembled, or in parts if there is limited transport access. Minimum dimension for entry = door dimensions with width of 60 cm. Bypass dampers on both the supply air side and the exhaust air side are included in alla VSE units. Optional accessories include for example an internal fire management solution and heating coil. The units are delivered with EC fans and, if needed, our patented, energy-efficient defrosting program.. Heat exchanger. At the heart of the system is a cross-flow heat exchanger in polycarbonate with high resistance to dirt and ice particles and a temperature efficiency of 90% at standard flow.. EC fans. Energy-efficient supply air and exhaust air fans with the latest EC technology. Fan impellers with high efficiency and low noise level.. Bypass damper. All units have a bypass damper on both the supply air side and the exhaust air side for optimal heat exchange control.. Filter. Supply air filter, class F7, included in all units. An optional exhaust air filter can be installed, or can be added later if desired.. Conversion damper. The units can be equipped with an internal fire management solution based on either converted supply air or a bypass damper beside the exhaust air filter for the fire management solution operating fans. Unit VSEi -, -, m /s VSEi -8, -, m /s VSEi -, -,8 m /s VSEi -0 0,9 -, m /s VSEi -6 0,7 -,8 m /s VSEi - 0, -, m /s VSEi -08 0, -,0 m /s VSEi -0 0, - 0,6 m /s 0 0,,0,,0,,0,,0, Flow, m /s VSEt Unit for roof installation VSEt has a top-fitted hood opening, and is normally recessed in the roof of the building. All service and maintenance is done through the top-fitted hood opening, and all components are positioned for easy access. The unit is designed to look aesthetically attractive when installed on the building s exterior. VSEt is the favourite of architects and surface optimisation engineers. Unit VSEt -6 0,7 -,8 m /s VSEt - 0, -, m /s VSEt -08 0, -,0 m /s VSEt -0 0, - 0,6 m /s 0 0,,0,,0 Flow, m /s 0

7 6 VSM Modular unit 0, m/s - m/s VSM is a modular unit for higher flows. The unit is designed for ventilation of all types of buildings. The technology is optimal for industrial facilities and hospitals, or for similar applications where recirculated air must be avoided. The unit is normally installed on roofs or beam foundations. Depending on the specific installation, the modular unit can be adapted so that the desired function is achieved. The finished unit can be supplemented with coils for heating and cooling. The unit is delivered in modules that are docked together on site. This series features considerable flexibility with regard to combinations, air volumes and functions for minimising energy consumption in buildings.. Heat exchanger. At the heart of the system is a cross-flow heat exchanger in polycarbonate with high resistance to dirt and ice particles and a temperature efficiency of 90% at standard flow.. EC fans. Energy-efficient supply air and exhaust air fans with the latest EC technology. Fan impellers with high efficiency and low noise levels.. Bypass damper. All units have a bypass damper on both the supply air side and the exhaust air side for optimal heat exchange control.. Filter. Supply air filter, class F7, included in all modular units. An optional exhaust air filter can be installed, or can be added later if desired.. Conversion damper. The units can be equipped with an internal fire management solution based on either converted supply air or a bypass damper beside the exhaust air filter for the fire management solution operating fans. Built-in unit VSI 0, m/s - 0 m/s VSI is a built-in unit. All technical rooms have different characteristics and possibilities and sometimes the air handling unit doesn t even need to be installed in a technical room. To optimise a building s overall economy, it can often be beneficial to relocate the air handling system. The built-in unit, VSI, is designed and delivered as a turnkey system to optimise space, operating costs and energy consumption. These air handling units can be installed at lower ceiling heights, down to.90 m. This has allowed many of our customers to relocate their technical rooms away from areas that can be rented out, to for example garages, in order to reduce their energy costs and increase the property s net operating income. VSI is a concept from VoltAir System designed to optimise the available space.. Heat exchanger. At the heart of the system is a cross-flow heat exchanger in polycarbonate with a temperature efficiency of 90 % at standard flow.. EC fans. Energy-efficient supply air and exhaust air fans with the latest EC technology.. Bypass damper. All units have a bypass damper on both the supply air side and the exhaust air side for optimal heat exchange control.. Filter. Supply air filter, class F7, included in all built-in units. An optional exhaust air filter can be installed, or can be added later if desired.. Heating coil and cooling coil. Optional. 6. Cooling recovery. Optional. 7. Damper for recirculated air. Optional.

you should ask your air handling unit supplier 0questions Remember to make an LCC calculation It will pay off. The examples below refer to year-round operation in Stockholm with current energy prices ( March, 0) and industry-recognized operating data. Coil exchanger 0% temperature efficiency Maintenance % Investment 0% Maintenance % VoltAir System 90% Investment 8% 6 The outdoor temperature is minus ºC, the exhaust air has % air humidity and the air flows are nominal and balanced. What is the average temperature efficiency over three days if these conditions remain unchanged? Are there bypass dampers on both the supply air side and exhaust air side to provide optimal control of the heat recovery and to reduce the SFP value when recovery is not needed? Energy 8% vs. Money left over 7% Energy % 7 Is defrosting required in the above example? How is the heat exchanger cleaned, and what is the minimum cleaning frequency to retain the temperature efficiency? Cross-flow heat exchanger / Rotor 80% temperature efficiency Maintenance % Investment 0% Maintenance % VoltAir System 90% Is there a risk of exhaust air, particles and odours leaking into the supply air? 8 What is the equivalent SFP value for the heating coil and F7 filter? Energy 7% vs. Money left over % Investment % Energy 9% What service and maintenance will be required over a five-year period, in addition to filter replacement? What are the minimum required opening dimensions for installing a unit? 9 0 Can the unit be equipped with an internal fire management solution based on either converted supply air or a pressure control damper beside the exhaust air filter for the fire management solution operating fans? Is there a free choice of control system? www.voltairsystem.com VoltAir System AB Arenavägen Box 70 77 Stockholm Växel 08-60 6 00 Mobil 076-767 99 9 tomas.franden@voltairsystem.com Tomas Frändén VoltAir Systems System s överlägsna superior air luftbehandling unit i in praktiken practice Hittar If you du can t inte find våra our senaste latest customer praktikfall cases i den here, här fickan simply går go to du www.voltairsystem.com enklast in på www.voltairsystem.com and click och on REFERENCES. klickar på REFERENSER.

VoltAir System offers a unique economy, environmental and health concept for air exchange in buildings with a mechanical supply air and exhaust air system. Its proven technology ensures a long lifespan and highly efficient recovery of energy from the exhaust air. We offer a wide range of products including air handling units, fan room walls and inspection hatches. VoltAir System is a Swedish product manufactured in Torsby with marketing and development in Stockholm. We are a flexible company that complies with the latest market requirements for responsible system performance. We constantly strive to develop our business and remain one step ahead. Our product is the market leader in terms of economy, environmental performance and health. Stockholm Address: Box 70, 07 Stockholm Globen Street address: Arenavägen, plan 6, 77 Johanneshov Phone: +6 (0)8 60 6 00 Email: info@voltairsystem.com Torsby Street adress: Vinkelvägen 68 Torsby Phone: +6(0)8 60 6 00