International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015

Similar documents
Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Enhancement of COP in Vapour Compression Refrigeration System

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

Performance of an Improved Household Refrigerator/Freezer

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

STUDY OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING DOUBLE PIPE HEAT EXCHANGER

Performance investigation of Air-conditioning system using ejector as expansion device

International Journal of Research in Engineering and Innovation Vol-1, Issue-5 (2017), 68-72

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

(Refer Slide Time: 00:00:40 min)

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Volume 4, Issue 1 (2016) ISSN International Journal of Advance Research and Innovation

Design & Fabrication of Hybrid Cooler

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

International Journal of Research in Engineering and Innovation Vol-3, Issue-1 (2019), 1-5

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Thermodynamic Calculations of Two-Stage Vapor Compression Refrigeration Cycle with Flash Chamber and Separate Vapor Mixing Intercooler

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Vapour Compression-Absorption Cascade Refrigeration System- Thermodynamic Analysis

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Volume 2, Issue 4 (2014) ISSN International Journal of Advance Research and Innovation

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Waghmare Tushar Ramrao, D.S.Nakate

Analysis of Vapour Compression Refrigeration System with Refrigerants R134a, R143a, R152a, R290 and R32

*Corresponding author;

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

ISSN Electronic International Interdisciplinary Research Journal (EIIRJ) Bi-monthly Reviewed Journal Mar- April 2015

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Optimum Length of a Condenser for Domestic Vapor Compression refrigeration System

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

Adsorption refrigeration system using waste heat

Study of R-161 refrigerant as an Alternate Refrigerant to various other refrigerants

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Experimental Investigate on the Performance of High Temperature Heat Pump Using Scroll Compressor

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

ADVANCES in NATURAL and APPLIED SCIENCES

Effect of Condenser Subcooling of the Performance of Vapor Compression Systems: Experimental and Numerical Investigation

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

JJMIE Jordan Journal of Mechanical and Industrial Engineering

η second law = Second law efficiency

Numerical Simulation of Window Air Conditioner

Design, Manufacturing of Chilled Water System for Process Cooling Application

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

A Comparison Between Refrigerants Used In Air Conditioning

LECTURE-17. Multi-Stage Vapour Compression Refrigeration. 1. Introduction

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

PERFORMANCE OF SOLID DESICCANT COOLING WITH SOLAR ENERGY IN HOT AND HUMID CLIMATE

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Environment Protection Engineering

Volume 3, Issue 4 (2015) ISSN International Journal of Advance Research and Innovation

DESIGN, DEVELOPMENT AND TESTING THE

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

International Journal of Scientific & Engineering Research, Volume 5, Issue 7, July-2014 ISSN

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

Designated vs Non-designated Areas for Condenser Subcooling

PERFORMANCE ANALYSIS OF MULTIPURPOSE REFRIGERATION SYSTEM (MRS) ON FISHING VESSEL

Use of fourth generation ecofriendly refrigerants in two and three cascade refrigeration systems for reducing global warming and ozone depletion

Thermodynamic analysis of the performance of a vapour compression refrigeration system, working with R290 and R600a mixtures

The Effect of Condenserfluid Quality on the Performance of a Vapour Compression Refrigeration Cycle A Simulation Model Approach

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

Transcription:

International Journal of Engineering & Technology Sciences Volume 03, Issue 01, Pages 55-64, 2015 ISSN: 2289-4152 Performance Evaluation of Vapour Compression Refrigeration System Using Double Effect Condensing Unit (Sub-cooler) T. S. Mogaji a, *, R. K. Yinusa a a Department of Mechanical Engineering, Federal University Of Technology Akure, School of Engineering and Engineering Technology, P M B 704, Ondo State, Nigeria. * Corresponding author. Tel.: +2348143181937. E-mail address: mogajits@gmail.com A b s t r a c t Keywords: Vapour compression, Refrigeration system, Sub-cooling cycle, Double effect condensing unit system, Refrigerating effect, Coefficient of performance. This report presents a study on development and analysis of double effect condensing unit vapour compression refrigeration system (DECU VCR system). The system is composed by two refrigeration cycles working with R134a. Tests under a wide range operating temperature interval conditions were carried out on the developed system. Experimental data was generated to observe the performance of the basic VCR system and DECU VCR system for an important parameters such as condensation (35 to 55 C) and evaporation temperatures (-5 to 15 C). Performance evaluation of the system was characterized in terms of cooling capacity and coefficient of performance (COP). In the present study, both COP and refrigerating effect of the developed system have been found, in general, to be greater than the corresponding basic VCR system values, but the degree of enhancement varies depending on the test conditions. Additionally, by using dedicated subcooling cycle, up to 11 and 11.7 % performance improvement ratio of VCR system are observed at evaporation temperature of 15 o C and condensation temperature of 35 o C respectively. It can be concluded that the use of dedicated sub cooling cycle in VCR system is most efficient and suitable for the betterment of thermal system performance. Accepted: 13 February2015 Academic Research Online Publisher. All rights reserved. 1. Introduction Cooling in industrial process, air-conditioning of buildings and refrigeration of perishable products are common practice throughout the world [1]. As pointed out in the study of [2], these refrigeration systems on the whole, consume a large amount of 55 P a g e

energy since hundreds of millions are currently in use, and dozens of millions are coming onto the market every year. Generally refrigeration systems can be classified into 3 main cycle systems which are vapour compression refrigeration system, vapour absorption refrigeration system and gas cycle refrigeration system. According to [3], the most commonly used system in refrigeration and air-conditioning industry is vapour compression refrigeration system. As reported in the study of [4], a considerable part of the energy produced worldwide is consumed by refrigerators and it is crucial to minimize the energy utilization of these devices. In order to reduce this energy consumption, a high energy efficiency system should be adopted. Typical vapour compression refrigeration system uses a single condenser unit component to remove heat from high pressure superheated vapour refrigerant, sub-cooled it to saturated vapour state and then condenses into a saturated liquid state. Theoretically, the condensation process is considered under constant pressure. It is well known that the more the heat rejection in the condenser, the sub cooling of the liquid increases the refrigerating effect without increasing the work requirement and, consequently, increases the efficiency of the system. [5], also pointed out that the COP of vapour compression refrigeration system can be improved either by increasing refrigeration effect or by reducing work input given to the system. Therefore, consideration of double effect condensing unit vapour compression refrigeration system (DECU VCR system) for improving performance of the system becomes very worthy to be investigated. [6], discovered that adding extra internal heat exchanger in a single-stage cycles prior to expansion process sub cools the liquid refrigerant. [7], presented a concept of a sub-cool system in which the liquid receiver is installed before the last pass to a parallel flow micro channel condenser rather than at the exit of the condenser. They observed COP improvement benefitted from subcooling due to an increase in enthalpy difference across evaporator. [8], carried out experimental investigation of the effect of condenser liquid subcooling on a refrigeration system performance. Their result revealed that the COP and refrigeration cooling capacity of refrigerants; R134a (12.5%), R12 (10.5%) and R152a (10%), benefited from subcooling increase from 6 C to 18 C, while condensing temperature was kept artificially constant. [9], evaluated the performances of the selected refrigerants R23, R32, R134a, R143a and R152a in terms of heat exchanger effectiveness, capacity index and coefficient of performance in vapour compression refrigeration system by using a subcooling heat exchanger as a tool. [10], investigated the performance characteristics due to use of different refrigerant combinations in vapour compression cycles with dedicated mechanical sub-cooling. They reported that dedicated mechanical subcooling is more suited to cycles using R-134a as the main cycle refrigerant rather than R-717. [11], developed a refrigeration cycle which combines a basic vapour compression refrigeration cycle with an ejector cooling cycle for enhancement of the basic vapour compression refrigeration cycle. The authors concluded that the COP of the modified vapour compression refrigeration cycle improved by 9.1%. The objective of the present paper is to evaluate the performance improvement of a double effect condensing unit vapour compression refrigeration system (DECU VCR system). The performance evaluation was based on comparison between the basic vapour compression refrigeration system and 56 P a g e

the modified vapour compression refrigeration system dedicated to double effect condensing unit. The effects of condensation and evaporation temperatures on refrigerating effect and coefficient of performance (COP) of the system were also reported. 2. Description of the system and methodology Figure 1 shows a schematic diagram of the vapour compression refrigeration system with dedicated subcooling cycle. The components of the subcooling cycle are designed and coupled to the basic VCR system. Process 2-3 (Condensation process) represents the removal of latent heat which changes the dry saturated refrigerant into liquid refrigerant. The process 3-4 represents the subcooling of the liquid refrigerant leaving the basic VCR system condenser before passing through the expansion valve (4-5) for the onward throttling of the liquid refrigerant from the condenser pressure to the evaporator pressure and then evaporate in the evaporator (5-1), in this study these processes are enhanced using a dedicated subcooling cycle (6-7-8-9). With the dedicated subcooling modification, liquid refrigerant leaving the condenser is further cooled at constant pressure to an intermediate temperature, T4, as shown in Figure1. Finally, the vaporized refrigerant is circulated through the compressor (1-2) and then condensate in the condenser (2-3). In this way, less work is used to operate the compressor of the DECU VCR system and, consequently, enhance the performance of the system. Fig. 1: schematic diagram of the vapour compression refrigeration system with subcooling cycle. 3. System development and analysis involves development and analysis of a double A simple VCR system consist of a compressor, air effect condensing unit vapour compression cooled condenser, expansion device and refrigeration system. This investigation begins with evaporator. Due to the need of high energy efficiency refrigeration system a double effect condensing unit vapour compression refrigeration system is hereby proposed in this study. This study thermal analysis of the developed refrigeration system taking into consideration the system cooling load which is made up of (i) The heat transferred through the refrigerating space wall, (ii) Heat added 57 P a g e

to the refrigerating compartment whenever the system door is opened otherwise known as infiltration load and (iii) The heat gained from the products otherwise known as the product load. The thermal analysis results were used to predict the capacity/volume of each component in the developed system. Shown in Figure 2 is the pressure-enthalpy diagram of the developed double effect condensing unit VCR system where the basic VCR system and subcooled system cycle are represented by processes 1-2-3-4-5 and processes 6-7-8-9 respectively. The process 6-7 is the evaporator of the subcooling cycle which serves as the subcooler of the basic VCR system condenser. However, more focus of this study is given to the heat rejected by the condenser of the basic VCR system, since it is a fundamental input for the design of the double effect condensing unit vapour compression refrigeration system components. W c Basic VCR system Wc Sub-cooling VCR system Fig. 2: pressure-enthalpy diagram of the developed double effect condensing unit VCR system. The basic VCR system refrigeration capacity is The heat rejected by the basic VCR system calculated as follows: condenser is calculated as follows: Q Ebasic = m (h 1 h 5 ) (1) Q Cbasic = m (h 2 h 3 ) (4) where the subscript 1 and 5 refers to the enthalpies where, the subscript 3 refers to the enthalpy at the at the exit and inlet of the basic VCR system exit of the basic VCR system condenser. evapour ator respectively. The refrigeration capacity of the sub-cooling VCR The work done by the basic VCR system system is calculated as follows: compressor is calculated as follows: Q Esub = m (h 7 h 6 ) (5) W Cbasic = (h 2 h 1 ) (2) The work done by the sub-cooling VCR system where, the subscript 2 refers to the enthalpy at the compressor is estimated as follows: exit of the basic VCR system compressor. W Csub = (h 8 h 7 ) (6) And the compressor power required by the basic where, the subscript 8 refers to the enthalpy at the VCR system is estimated as: exit of the sub-cooling VCR system compressor. P Cbasic = m W Cbasic (3) Thus, the compressor power required by the subcooling VCR system is estimated as: 58 P a g e

P Csub = m W Csub (7) The heat addition to the sub-cooling VCR system evaporator must be rejected in the sub-cooling VCR system condenser at the cost of the work of the sub-cooling VCR system compressor. Thus resulting in a trade-off between the amount of sub-cooling provided to the basic VCR system and the amount of work performed by the subcooling VCR system compressor. Hence, the heat rejected by the sub-cooling cycle condenser is calculated as follows: Q Csub = m (h 8 h 9 ) (8) where, the subscript 9 refers to the enthalpy at the exit of the sub-cooling VCR system condenser. 4. Performance evaluation Experimentally, evaporation temperatures of both the basic VCR system and the double effect condensing unit VCR refrigeration system are obtained for condensation temperatures range from 35 to 55 at temperature interval of 5, using Refrigerant 134a as a working fluid. Similarly, the corresponding condensation temperatures of both refrigeration systems are obtained across a range of evaporation temperatures from 5 to 15 at a temperature interval of 5. It should be noted that when one of them is varied, the other parameters remain constant at a practical value. Performances of both systems are evaluated based on the experimental data obtained. The evaluation of both refrigeration systems are characterized by refrigerating effect in terms of cooling capacity, compress power and coefficient of performance (COP) of the systems. The cooling capacity is calculated as: Q sub = m (h 1 h 5 ) (9) The compressor power is obtained as follows: P sub = m (h 1 h 2 ) (10) Thus, the coefficient of performance of the developed system is calculated as: COP sub = Q sub P sub (11) The COP improvement COP imp expressed in % is calculated as follows; COP imp = COP sub COP basic COP bsic 100% (12) where, the COP basic is the COP at the same evaporator and condenser temperatures of the basic VCR system. 5. Results and discussion The effects of important parameters such as condensation and evaporation temperatures on the systems performances are analysed in this section. 5.1. Effect of condensation temperature on COP of the system Figure 3 shows variation of condensation temperature on the coefficient of performance for both the basic VCR and the DECU VCR systems. From this figure, it can be noticed that the COPs for both systems decrease as the condensation temperature increases but with different rates. These trends are similar to those observed in the study of [5]. Basically, increasing of condensation temperature causes increase in the compressor power, decreasing the system cooling capacity, and consequently decreases the COP of the system. Moreover, COP of the modified system at lower condensation temperature is observed to be more sensitive higher than the COP of the basic VCR system which confirms the efficiency of system with double effect condensing unit as compared with the basic VCR system counterpart. Additionally, as condensation temperature decreases from 55 to 35 C, the improvement ratio in COP increases from 2.9% to 11.7% as shown in Figure 4. This trend can be attributed to lesser work used to operate the compressor of the DECU VCR system than the basic VCR system. 59 P a g e

5.2. Effects of evaporator temperature on COP of the VCR system Figure 5 illustrate the effects of the evaporation temperature on COP of both the DECU VCR and basic VCR systems. According to this figure, the first law efficiency of vapour compression refrigeration system (COP) increases as expected with increasing the evaporation temperature of both systems. This trend is similar to those observed in the studies of [4] and [12]. The DECU VCR system is more sensitive to increase in evaporation temperature as higher COP is observed at any application (air conditioning refrigeration and freezing). Such behavior is related to the fact that less work is used to operate the compressor of the DECU VCR system. Moreover, high energy efficiency of the modified VCR system can be noticed in Figure 6 as evaporation temperature increases from -5 to15, the COP improvement ratio increases from 3.1 to 11. Consequently affirming that sub cooling a vapour compression 15 system using double effect condensing unit improves performance of the system. 5.3. Effect of refrigerating effect on COP of the system Figures 7 and 8 display variation of refrigerating effect of both basic VCR and DECU VCR systems considering effects of both condensation and evaporation temperatures. According to Figure7, it can be noted that refrigerating effect increases with decreasing condensation temperature. This is due to reduction in exergy loss of the system under this operating condition. (i.e decreasing condensation temperature). Also, as can be observed in Figure 8, the refrigerating effect of both cycles is directly proportional to evaporation temperature. This effect is more pronounced for DECU VCR system. These behaviors can be attributed to lower pressure lift of modified system than basic VCR system. Thus, dedicated subcooling modification is responsible for the betterment of the system performance. Coefficient of performance 12 9 6 DECU VCR system BASIC VCR system 3 30 35 40 45 50 55 60 Condensation Temperature ( o C) Fig. 3: Variation of coefficient of performance with condensation temperature. 60 P a g e

Performance improvement ratio (%) 15 12 9 6 3 COPimp 0 30 35 40 45 50 55 60 Condensation Temperature ( o C) Fig. 4: Variation of performance improvement rate with condensation temperature. 15 Coefficient of performance 12 9 6 3 DECU VCR system BASIC VCR system 0-10 -5 0 5 10 15 20 Evaporation Temperature ( o C) Fig. 5: Variation of coefficient of performance with evaporation temperature. 61 P a g e

15 Performance improvement ratio (%) 12 9 6 3 0-5 0 5 10 15 20 Evaporation Temperature ( o C) COPimp Fig. 6: Variation of performance improvement rate with evaporation temperature. 160 Refrigerating effect(kj/kg) 150 140 130 120 DECU VCR system BASIC VCR system 110 30 35 40 45 50 55 60 Condensation Temperature ( o C) Fig. 7: Variation of refrigerating effect with condensation temperature 62 P a g e

Refrigerating effect(kj/kg) 160 150 140 130 120 DECU VCR system BASIC VCR system 110-10 -5 0 5 10 15 20 Evaporation Temperature ( o C) Fig. 8: Variation of refrigerating effect with evaporation temperature 6. Conclusions A double effect condensing unit VCR system was developed and presented in this paper. Performance evaluation of the system was characterized by refrigerating effect in terms of cooling capacity, compressor power and coefficient of performance (COP) of the system using R134a as a working fluid. The effects of condensation and evaporation temperatures were studied on the system operation and performances. From the present study, the following main conclusions can be drawn: i. The COP and Refrigerating effect of DECU VCR system is higher compares with the basic VCR system counterpart. ii. By using dedicated subcooling cycle, up to 11 and 11.7 % performance improvement ratio of vapour compression system are observed at evaporation temperature of 15 o C and condenser temperature of 35 o C respectively iii. As the condensation temperature decreases the COP of the VCR system increases. Similarly, Refrigerating effect of the system increases. iv. Condensation temperature has the highest effect on the system performance improvement ratio. As the condensation temperature decreases from 55 to 35 o C, the performance improvement ratio of the system increases geometrically. v. As the evaporation temperature increases, the COP and the Refrigerating effect of the VCR system increases. vi. According to the preceding analysis on performance evaluation of both basic VCR and DECU VCR systems. It can be concluded that the use of dedicated sub cooling cycle in VCR system is most efficient and suitable for any cooling system application (air conditioning refrigeration and freezing). Acknowledgments The authors would like to acknowledge the assistance of the Refrigeration and Air Conditioning Unit of the Department of Mechanical Engineering, Federal University of Technology Akure in supplying the equipment used in the present study. The technical support given to 63 P a g e

this investigation by Mr. K. A. Adewole is also appreciated and deeply recognized. References [1] Dahmani, A., Aidoun, Z., Galanis, N. Optimum design of ejector refrigeration systems with environmentally benign fluids. International Journal of Thermal Sciences 2011; 50:1562-1572. [2] Gonçalves, J. M. Cládio, M. Hermes, C. J. L. A semi-empirical model for steady-state simulation of household refrigerators. Applied Thermal Engineering 2009; 29: 1622-1630. [3] Karamangil, M. I. Coskun, S. Kavnaki, O., Yamankaradeniz, N. A simulation study of performance evaluation of single- stage absorption refrigeration system using convectional working fluids and alternatives. Renewable and Sustainable Energy Reviews (2010); 14: 1969-1978. [4] Mohan, C. Exergy analysis of vapour compression refrigeration system using R12 and R134a as refrigerants. International Journal of Students Research in Technology & Management 2014; 2(04): 134-139. [5] Mishra, R. S. Methods of improving thermodynamic performance of vapour compression system using twelve eco-friendly refrigerants in primary circuit and nanofluid (waternano particles based) in secondary circuit. International Journal of Emerging Technology and Advanced Engineering (2014); 4(6): 878-891. [6] Domanski, P.A., Didion, D.A. Evaluation of suction-line/liquid-line heat exchange in the refrigeration cycle. International Journal of Refrigeration (1994); 17: 487-493. [7] Yamanaka Y, Matsuo H, Tuzuki K, Tsuboko T, 1997, Development of sub-cool system, SAE Technical Paper Series, paper 970110. [8] Linton, J.W., Snelson, W.K., Hearty, P. F. Effect of condenser liquid subcooling on system performance for refrigerants CFC-12, HFC-134a and HFC-152a. ASHRAE Transactions 1992; 98: 160-146. [9] Akintunde M.A., Bolaji, B.O., and Falade, T.O. Theoretical investigation of the performance of some environment-friendly refrigerants in a subcooling heat exchanger refrigeration system, Journal of Science and Technology 2010; 30(3):101-108. [10] Qureshi, B.A., Zubair, S.M. The effect of refrigerant combinations on performance of a vapour compression refrigeration system with dedicated mechanical sub-cooling, International Journal of Refrigeration 2012;35(1): 47-57. [11] Zhu, Y., Jiang, P. Hybrid vapour compression refrigeration system with an integrated ejector cooling cycle, International Journal of Refrigeration 2012; 35(1): 68-78. [12] Elgendy, E. parametric study of a vapour compression refrigeration cycle using a two-phase constant area ejector, International Journal of Mechanical, Aerospace, Industrial and Mechatronics Engineering 2013; 7(8):1-7. 64 P a g e