Addendum to the DVC/DAA Manual (52411) for H Manual Revisions

Similar documents
1 UL 864 Compliance. 2 Product Overview. Network Communications Module NCM-W/F Product Installation Document. 1.1 Products Subject to AHJ Approval

ONYXWORKS AND FIRSTVISION. Version 4

FieldServer Driver - Serial FS Notifier NCA

STROBE / SOUNDER INTERFACE

ONYXWorks. ONYXWorks NOTIFY IP. Installation & Operation Manual. Document /23/11 Rev: A3 P/N: 53620:A3 ECN:

Section 8 System Operation

E3 Series Broadband System

PRODUCT BULLETIN. Rev. A Monitoring Station offering PN Rev. B as a direct replacement. OVERVIEW / DESCRIPTION

E3 Series Broadband System

MIR2. System Operations Manual. P/N Rev 1.5 OCT98

1.1 The Network Communications Module for Wire (NCM-W) Channel A & B Connections. Network Connection Ports (NUP)

FST DFS Notifier Onyx 640

A World of Solutions in Fire Protection Systems

Network Hardware and wiring (quiz)...

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Software Release M2.7 Summary for the Notifier AM2020/AFP1010 Fire / Security Control Panels, Including NOTI FIRE NET and Peripherals

Fire Alarm Control Panel AFP Programming Manual. Australia Edition. Document DOC Rev: E 11/12/2018 ECN:

Innovative protection that combines power and flexibility

Section 9 System Operation

ADE Gen4. Speech Dialler Engineering Information. Description. Features

A World of Solutions

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

SCAN200E USER S MANUAL

PERS-3600 PERSONAL EMERGENCY REPORTING SYSTEM INSTALLATION & OPERATION INSTRUCTIONS

Fire Alarm Control Panel AFP Operations Manual. Australian Edition. Document DOC /11/2015 Rev: P/N DOC :B

Simplex Panel Interface Guide

DSC Power832/PC5010 Wiring the MN01-4G Cellular Communicator and Programming the Panel

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

2000 Series. Program Entry Guide. Control Panels

USER MANUAL FOR OPERATING SYSTEM

QUICKFIT INSTALL HOOK-UP SHEET FOR ESL KIT REV 1.17 OP

INTELLIGENT FIRE ALARM AND AUDIO NETWORK SYSTEM. Features

ANNUNCIATOR FIXED MODULE

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

Laptop / PC Programming Manual

Memcom Emergency Telephone

Interrogator 200 Audio Verification Module (AVM)

Panel Remote Annunciators Installation Instructions

Sensaphone 400 Telemetry System Integration

DYGIZONE GJD910 Lighting Controller & Enunciator

R Series Remote Annunciators and Expander Installation and Operation Guide

A World of Solutions

The System 5000 Operating Manual

Signature Series Auto-Sync Output Module (CC1S)

JDVC Digital Voice Command and Amplifiers Series

TD80 LEVEL GAUGING & OVERFILL PREVENTION SYSTEM PRODUCT MANUAL SUPPLEMENT. TPM 005 Revision 0.0

Quick Reference Guide

Weekly Testing of Dedicated Stairwell Pressurization Fans- Metasys System Extended Architecture Code No. LIT

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Specifications Minimum Typical Maximum Unit

NETWORKING AND INTEGRATION

CHEAT SHEET: SPECTRA V2.1

ONYX FirstVision Specification Interactive Firefighters Display

E911 Manual. Empowered by Innovation P/N E911. For additional resources, visit our Technical Support site on the web at

Print Specification. Publication. Instructions. Specific requirements. General requirements

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

CSP-204 CSP-208 CSP-104 CSP-108

FIRE FIRE. 4100U Fire Alarm. Operator's Manual. Technical Manuals Online! -

Annunciator Control System ACS Series

Intrinsically Safe Solutions

Operator s Manual Part: InfoAlarm Product: 4100U, 4100ES Rev. B

ION Meter Alerts TECHNICAL NOTE NOVEMBER In This Document

RM-1 Series. Remote Microphones. (RM-1, RM-1SA) Document Revision B RM-1 RM-1SA. RM-1 on ADP-4 dress panel. RM-1SA in a CAB-RM or CAB-RMR

Installation Instructions. Fire Command Center/Fire Alarm Annunciators D1256/D1257

NetSOLO Classic. Voice Evacuation. Intelligent, Networked, Multi-Channel and Bulk Amplification Voice Evacuation System FEATURES & BENEFITS.

Planning Instructions MEW01472 Revision -

Installing a Fan Tray in an Ethernet Routing Switch 8000 Series Chassis

TrueAlarm Fire Alarm Systems

USER MANUAL DexTempTM 1000 Temperature Monitor (P/N: IR-1001) DexTempTM 1000 USB Non-Contact Temperature Monitor. User Manual.

Weekly Testing of Dedicated Smoke Control Dampers - Metasys System Extended Architecture

Ion Gateway Cellular Gateway and Wireless Sensors

EST3 Installation and Service Manual

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

D8024, D9024, D10024 Analog Fire Alarm Control Panels Programming Guide

AT60 AUTO DIALLER User Guide

EL-OEM-3 OEM Packaged Voltage Data Logger

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Alarm Tone Generator Model AG17

Installation & Operations Manual

4100U City and Relay Cards Installation Instructions

ERS-3600B. PERS-3600B Personal Emergency Reporting System

Planning Instructions MEW01776 Revision -

SIGA-CC1 Single Input Signal Module Installation Sheet

FireFinder XLSV Digital Emergency Voice Alarm / Communication System

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

1. Introduction. 2. Product overview

PC4020 v3.2 Installation Manual DLS-3 v1.3

ELT-KLED EliteSuite LED Keypad Installation Manual

D6500 reports are shown in typewriter style letters. For example, AC FAILED indicates the report sent when the panel reports an AC power failure.

Radionics D4112 Program Sheet

OnGuard 7.2 Resolved Issues

Quick Installation Manual LED Touch Keypad Autodial Wireless Alarm System

3226 Trunk Port FXO Doorphone

CEM-24 Series. Owner's Manual - Installation and Operating Instructions

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

SEAR II APPLICATION 9V736-A01D PREPARED FOR NORFOLK SOUTHERN

Driver Manual. FS (Notifier NFS-640 NFS-320 NFS2-640)

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

INSTRUCTIONS. Eagle Quantum Premier (EQP) Addressable Smoke & Heat (ASH) Module EQ3750ASH. 5.1 Rev: 4/

Transcription:

Addendum to the /DAA Manual (52411) for H Manual Revisions Document 52411ADD 05/12/2009 Rev: A P/N 52411ADD:A ECN 09-064

Software Downloads In order to supply the latest features and functionality in fire alarm and life safety technology to our customers, we make frequent upgrades to the embedded software in our products. To ensure that you are installing and programming the latest features, we strongly recommend that you download the most current version of software for each product prior to commissioning any system. Contact Technical Support with any questions about software and the appropriate version for a specific application. Documentation Feedback Your feedback helps us keep our documentation up-to-date and accurate. If you have any comments or suggestions about our online Help or printed manuals, you can email us. Please include the following information: Product name and version number (if applicable) Printed manual or online Help Topic Title (for online Help) Page number (for printed manual) Brief description of content you think should be improved or corrected Your suggestion for how to correct/improve documentation Send email messages to: FireSystems.TechPubs@honeywell.com Please note this email address is for documentation feedback only. If you have any technical issues, please contact Technical Services. 2 NOTI Bookname P/N 52411ADD:A 05/12/2009

This supplement includes information regarding software version 3.2 and higher. It describes how to program the priority for the FFT-NFN input. It also modifies the examples to show one-button activation for annunciators, and, on pages 7 8, gives a modified annunciator point explanation. Software version 14.1 and higher for the NFS2-3030 and NCA-2 is compatible with this release of software. Page 57 - The following cautions have been added in the Inputs section of the Audio Message Programming. ARROW KEYS - Use to reassign the priority of an individual input.! CAUTION: 1 Do not program FFT-NFN with a priority greater than the following inputs: Local RM-1 Remote RM-1 Local Mic Remote Mic Local Tel Network Tel 2 The endpoints of an FFT-NFN link must be programmed with the same FFT-NFN priority. Page 74 - Replace Section 4.3.2 Point-to-point FFT Communication over Noti-Fire-Net (FFT-NFN) with the following. 4.3.2 Point-to-point FFT Communication over Noti-Fire-Net (FFT-NFN) software version 3.2 supports FFT communications between two digital audio loops on the same Noti- Fire-Net network. All s and DAAs must be PCB version hardware or higher (not PCA versions) and running software Version 3.2 and software Version 3.40 or higher, as well as NFS2-3030/NCA-2 software version 14.1 and higher. Example 1 Refer to Figures 4.3 and 4.4 for this example. A call initiated at an FFT (C) on a node can be answered at another (A). This will require turning on two communication links: 1. the link between the FFT (C) and its (B), and 2. the link between (A) and (B) (the FFT-NFN link on Noti-Fire-Net). C N1L1M2 N3 A FFT-NFN Link on Noti-Fire-Net N7 B DAA DAL Figure 4.3 FFT-NFN Communication Links Example 1 NOTI Bookname P/N 52411ADD:A 05/12/2009 3

One -KD or ACS annunciator point is required to establish and terminate this communication. The point must be programmed with the ACS function/mode FFT-NFN. Figure 4.4 shows the point programming. -KD or ACS programming: ACS function/mode = FFT-NFN Mapping: as indicated in point label Point mapping - connects (A) to (B) to (C) N3,N7,N1L1M2 -KD or Annunciator at (A) Figure 4.4 Point Programming for Figure 4.3 Example This setup would operate as follows: 1. A firefighter jacks in at (C). Point 1 rings and both LEDs flash at (A). 2. The operator at (A) presses the point button, programmed as shown in Figure 4.4, turning on the point. The point active LEDs will light steady on, and the yellow LEDs will go off. Communication is established between (C) and the local telephone at (A). The N3,N7 portion of the point programming controls the Noti-Fire-Net communication - (A) to(b) in this example. The N1L1M2 portion of the point programming controls the telephone communication between the field telephone and the at node 3. (In this example, N1 would be the panel controlling the telephone module.) NOTE: The FFT-NFN link will accommodate communication between two s at a time. If the FFT-NFN link is in use by two other s when the Point 2 button is pressed, the attempt to link (A) and (B) will be denied. A system trouble will display on an NCA-2 or NWS. 3. When the FFT-NFN connection is no longer needed, the operator at (A) disconnects the call by pressing the point button to disconnect. The FFT-NFN link will be automatically disconnected, because no other points are active at the -KD or annunciator on the (A) to(b) link. The link will close once all the active FFT-NFN points mapped to the -KD or annunciator have been turned off. Example 2 Refer to Figures 4.5 and 4.6 for this example. Calls initiated at more than one FFT on a node can be answered at another. This communication requires turning on the following communication links: 1. the links between the FFTs and their local ( (B) to (C), (D), and (E), and 2. the link between (A) and (B) (the FFT-NFN link on Noti-Fire-Net). E N1L1M5 C N1L1M2 N3 A FFT-NFN Link on Noti-Fire-Net N7 B DAL DAA D DAA 2 N7A2T Figure 4.5 FFT-NFN Communication Links Example 2 4 NOTI Bookname P/N 52411ADD:A 05/12/2009

-KD or ACS annunciator points are required to establish and terminate this communication. These points must be programmed with the ACS function/mode FFT-NFN. Figure 4.6 shows the point programming. -KD or ACS programming: ACS function/mode = FFT-NFN Mapping: as indicated in point label Point 1 mapping - connects (A) to (B) to (C) Point 2 mapping - connects (A) to (B) to (D) Point 3 mapping - connects (A) to (B) to (E) Point 1 Point 2 Point 3 N3,N7,N1L1M2 N3,N7,N7A2T N3,N7,N1L1M5 -KD or Annunciator at Node 3 Figure 4.6 Point Programming for Figure 4.5 Example This setup would operate as follows. 1. A firefighter jacks in at (C). Point 1 rings and both LEDs flash at (A). 2. The operator presses Point 1, turning on the point. The point active LEDs will light steady on, and the yellow LEDs will turn off. Communication is established between (C) and the local telephone at (A). If pressing Point 1 activates (C) but does not open the FFT-NFN link, the (A) and (C) point LEDs will continue to flash because the FFT-NFN link is not available. A system trouble (NFN PAGING CHANNEL LIMIT EXCEEDED) will display on an NCA-2. 3. Firefighters jack in at (D) and (E). Points 2 and 3 ring at (A), the point active LEDs light steady and the yellow LEDs flash. The operator at (A) presses the Point 2 and 3 buttons (either the Point 2 and 3 -KD buttons or the Point 2 and 3 ACS annunciator buttons), programmed as shown in Figure 4.6, turning on the points. The yellow LEDs will turn off. Communication is established between the field telephones at (C), (D) and (E) and the local telephone at (A). (A) through (E) are now in communication. NOTE: (D) is on a riser with no telephone control modules installed, so mapping is to the DAA in the format NxAxT, where A = DAA address on the DAL (digital audio loop). 4. (C) jacks out. The operator presses Point 1 to terminate the connection with (C). Points (D) and (E) are still active, and continue to communicate over the FFT-NFN link. 5. (D) and (E) jack out. The operator presses Points 2 and 3 to terminate these connections. The FFT-NFN link automatically terminates, because no FFT-NFN programmed points remain active on it. Example 3 Refer to Figures 4.7 and 4.8 for this example. A call initiated at an FFT on a node can be connected to an FFT on another s digital audio riser. This communication requires turning on three communication links: 1. the link between the FFT (F) and its (A). 2. the link between (A) and (B) (the FFT-NFN link on Noti-Fire-Net ) NOTI Bookname P/N 52411ADD:A 05/12/2009 5

3. the link between the FFT (C) and its (B). N3 A N9L1M8 F FFT-NFN Link on Noti-Fire-Net N7 B E N1L1M5 DAL DAA C N1L1M2 D DAA 2 N7A2T Figure 4.7 FFT-NFN Communication Links Example 3 -KD or annunciator points are required to establish and terminate this communication. These points must be programmed with the ACS function/mode FFT-NFN. Figure shows the point programming. -KD or ACS programming: ACS function/mode = FFT-NFN Mapping: as indicated in point label Point 1 Mapping - Connects (A) to (B) to (C) Point 2 Mapping - Connects (A) to (B) to (D) Point 3 Mapping - Connects (A) to (B) to (E) Point 4 Mapping - Connects (A) to (B) to (F) Point 1 Point 2 Point 3 Point 4 N3,N7,N1L1M2 N3,N7,N7A2T N3,N7,N1L1M5 N3,N7,N9L1M8 Figure 4.8 Point Programming for Figure 4.7 This setup would operate as follows. 1. A firefighter jacks in at (C). Point 1 rings at (A), and both LEDs flash. The operator presses Point 1, turning on the point. The point active LED will light steady on, and the yellow LED will turn off. Communication is established between the field telephone at (C) and the local telephone at (A). 2. A firefighter jacks in at (F). Point 4 rings at (A), the point active LED lights steady, and the yellow LED flashes. The operator presses Point 4, turning on the point. The yellow LED will turn off. Communication is established between the field telephones at (F) and (C). 3. (C) and (F) jack out. The operator presses Points 1 and 4 to terminate these connections. The FFT-NFN link automatically terminates, because no FFT-NFN programmed points remain active on it. Example 4 -KD or Annunciator at Node 3 Refer to Figures 4.9 and 4.10 for this example. A can communicate directly with another via the FFT-NFN connection. The local phone at one node can be connected to another: the link between (A) and (B) (the FFT-NFN link on Noti-Fire-Net.) Local phone N3 A FFT-NFN Link on Noti-Fire-Net N7 B Local phone Figure 4.9 FFT-NFN Communication Links Example 4 6 NOTI Bookname P/N 52411ADD:A 05/12/2009

-KD or annunciator points are required to establish and terminate this communication. These points must be programmed with the ACS function/mode FFT-NFN. Figure 4.10 shows the point programming. There must be a programmed point at each for this link to function. -KD or ACS programming: ACS function/mode = FFT-NFN Mapping: as indicated in point label N3,N7 Point 1 Point 1 Mapping - Connects (A) to (B)) Point 1 N3,N7 -KD or Annunciator at Node 3 -KD or Annunciator at Node 7 Figure 4.10 Point Programming for Figure 4.9 Example This setup would operate as follows. 1. The operator at node 3 (A) picks up the local telephone and presses Point 1, turning on the point and making the FFT-NFN connection. The local telephone at node 7 (B) rings, and both LEDs flash. 2. The operator at node 7 (B) answers by picking up the phone and pressing Point 1 to speak. (A) and (B) are now in communication over the FFT-NFN link. The point active LEDs at both points light steady, and the yellow LEDs turn off. 3. To end the connection, one of the operators presses the Point 1 button to disconnect the FFT-NFN link. Priority FFT-NFN communication has a programmable priority (default message priority of 1042, refer to Table 3.1 on page 58). FFT-NFN will: be preempted by any message with a higher priority. preempt a lower priority message. not preempt an active message with the same priority (that is, another FFT-NFN connection). Local riser functionality, as described in FFT Communication Local to Node, remains the same while there is an FFT-NFN connection. FFT-NFN explanation for annunciator points: ACS Point Mode FFT-NFN Function: The point...will, when pressed: Notify a in the map format Nxxx,Nxxx,NxxxLyyMzzz or Nxxx,Nxxx,NxxxAyyT to open the FFT-NFN link and turn on the mapped FFT point or riser. A second press will notify the to turn off that FFT point or riser and determine whether the FFT-NFN link should be closed or remain open. Notify a in the map format Nxxx,Nxxx to close or open the FFT-NFN link between two s. Explanation The Point Active LED is lit if a corresponding mapped point is active. The Status (trouble) LED is on when a point or zone is disabled or in trouble. Table 5.4 ACS Point Mapping: Explanation of Point Modes NOTI Bookname P/N 52411ADD:A 05/12/2009 7

FFT-NFN explanation for annunciator mode sources: FFT-NFN mode sources: format Nxxx,Nxxx,NxxxLyyMzzz: Telephone control module (NxxxLyyMzzz) preceded by the node numbers of the two s (Nxxx,Nxxx) that will communicate over the FFT-NFN link. format Nxxx, Nxxx:: numbers of the two s that will communicate over the FFT-NFN link.. format NxxxAyyT: Use this address (N = the node number and A = the DAA address on the digital audio loop) when no telephone control modules are installed on a DAA s. Refer to the FFT-NFN section of the manual for programming and application examples. 8 NOTI Bookname P/N 52411ADD:A 05/12/2009