TRIPLE WAVEBAND INFRARED FLAME DETECTOR

Similar documents
Instruction manual for the Infrared Point Type Flame Detector

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

Evolution Analogue Addressable Fire System

IFD-E Flame Detector User Manual

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

Model DRD-AS Conventional Infrared Flame Detector User Manual Ver. 1.0

Reflective Optical Beam Smoke Detector User Guide

IFD-E Flame Detector User Manual

talentum Flame detection across the spectrum Range Brochure

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

FIRE IR SENSOR Flame Detection

Conspec - Why use our Flame Detectors

Dräger Flame 2500 (IR3) Flame Detection

Open-area Smoke Imaging Detection (OSID)

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Flame Detector User Manual

Dräger Flame 2700 (Multi-IR) Flame Detection

Dräger Flame 2500 Flame Detection

Flame Detection Jon Sarfas

Infrared Flame Detectors

Talentum - Why use our Flame Detectors?

Interface Modules for SENTRI

Installation Guide. Ceiling PIR Detector (311) Features and Connections

SAFETY MANUAL. FL4000H and FL4000 Multi-Spectral Infrared Flame Detectors

Commercial Series TriTech+ Motion Detector with Anti-mask

DF1151-Ex Infrared flame detector

Fire Safety. Installation Instructions Model MMB-2 Main Control Board OPERATION. INSTALLATION Always remove power before installation.

Infrared Flame Detectors

Instructions AutroFlame IR Flame Detector BG-201/BG-21

Basic Vehicle Fire Protection Manual

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

DF1101-Ex Infrared flame detector

English. Italiano. Português. Françias. Español

Touch Screen 1 loop Addressable Fire Alarm Panel

COMPACT FLAME CONTROLLER CFC 1000

Dräger Flame 2100 (UV) Flame Detection

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

Dräger Flame 2100 Flame Detection

Fire Detection systems. UniVario industrial fire detectors for every job

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

CONVENTIONAL FIRE ALARM CONTROL PANEL

SERIES VAC Microprocessor-Based Intermittent Pilot Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION

EVA-SCM-SCI Sounder Control Module

Dräger Polytron Pulsar 2 Open Path Gas Detector

COMPACT FLAME CONTROLLER CFC 2000

Dräger Flame 2350 (UV&IR) Flame Detection

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

IRtech. E instruments. IRtech Radiamatic IR20 LS series. Infrared Technology

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Talentum Flame Detector User Guide

Model 20/20MI Mini Triple IR (IR3) Flame Detector

Evolution Product Range

Pyroelectric Infrared Sensor PIR

7EF/7HF/7EC/7ES Temperature Controllers

Laser Level Measurement Products. Introducing the New LLT100

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

11,9. Ordering data. Max. cable length sensor head 1 basicdim ILD lx 150 lx m 1

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Dräger Flame 2370 (UV&IR) Flame Detection

Modline. 5 Stand Alone Temperature Sensor. You can bet your process on it!

Technical Data Sheet 5mm Infrared LED, T-1

Flame Detector. Model: ZT-30P. User Guide. Document Ref: GLT Zeta Alarms Limited Morfa Road, Swansea, SA1 2EN, United Kingdom

SEC Signature Process Gas Analyzer

Quick Selection Guide Fire Systems LSN Periphery

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

luxcontrol lighting control system basicdim basicdim ILD 16DPI 69f Compact control module with ambient light sensor and motion sensor

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

System 800 Addressable Fire Detection & Alarm System

UV-IR Flame Detector User Manual. Model: VS-200P

D7052. Installation Instructions Multiplex Dual Input Module

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

SharpEye Flame Detector Selection Guide

Design Manual Installation Operation Maintenance

Pyroelectric Infrared Sensors

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

D-Tect 2 GJD300 Quad PIR Movement Detector

AP200 SERIES INTELLIGENT ALARM DEVICES

PS914 Power Supply. 900-KL Keylock (optional) Page BB Battery Backup (optional) Page 3

I am Rick Jeffress and I handle sales for Fike Video Image Detection. We thank the AFAA for coordinating the venue for this presentation, and we

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

ALARMLINE ANALOGUE Linear Heat Detection System

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

Conventional Fire Detection

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Fireray 2000 Linear Smoke Detector

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

Conventional Fire Alarm Systems

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

The SharpEye 40/40I (IR3) Flame Detection

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

HX-80NRAM. High Mount Outdoor Detector

Infrared Temperature Sensor

TITLE SLIDE FIRERAY50/100R OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

Transcription:

RIPLE WAVEBAND INFRARED FLAME DEEOR Features Description he is a triple waveband infrared flame detector ideal for indoor/outdoor non-hazardous environments. Its three built-in infrared sensors can detect fuel fires at long distances with a high immunity to false alarms. he is equipped with a manual and automatic Self-est function to assure continued reliable operation. Its Omniview indicator provides 360 visibility for easy status recognition by four types of color illumination. he has the same interface to a previous model of 2RA3-PF, which provides compatibility for wiring. Optional weather-proof hood offers an enhancement of tolerance to the rise of temperature due to the direct sunlight. riple waveband infrared flame detection for optimum false alarm immunity Detection range adjustable up to 60 m* Omniview 360 LED indicates the conditions of detector by four different color illumination (Alarm, rouble, Startup, esting) Self-est function for monitoring window lens obscuration and circuit troubles Dust-Proof and Water-Proof Outdoor installation available Responds to flickering flames Selectable Response time and Self-est cycle Stylish low profile design urrent consumption approx. 6 ma (quiescent), 40 ma (max.) Equipped with an angle adjustable bracket having fine scale Dimensions [ op ] * 0.1 m 2 n-heptane pan fire [ Front ] [ Side ] (mm) Nittan reserves the right to make changes at any time without notice in prices, colours, materials, components, equipment, specifications and models and also to discontinue models. -DA-00 Rev.0

Directional Sensitivity and Range Directional Sensitivity and Range Direction 40 30 0 10 20 10 High 20 Middle 30 Low 40 50 50 60 60 70 70 80 80 90 60m 50m 40m oward A or B 30m 20m 10m 90 10m 20m 30m 40m 50m 60m oward or D Selectable Detector Sensitivity Detector Sensitivity Detection Range High (default) 60 m Middle 30 m Low 15 m Detectable Flame Size 50cm 30cm 10cm (Sensitivity = High) 1 m 10m 20m 30m 40m 50m 60m (N-Heptane fire on a 0.1 m 2 pan) Detector sensitivity is selectable from 3 values by a dedicated setting tool. Detection range is a detectable distance for a 0.1 m 2 n-heptane pan fire. he has a detection range of 60 m away and a wide angle of 100 degrees toward horizontal and vertical directions. riple Wavelength IR Detecting Wavelength range for identifying a true fire O2 resonance emission Wavelength [µm] Fire (flame) has a characteristic peak at 4.4 µm in a spectral distribution, which is called as O2 emission. he has 3 sensors that monitor the band of O2 emission and two wavebands on either side respectively. he detector avoids false alarms by the feature of frequency-fluctuation detection. Page 2 of 5 -DA-00 Rev.0

OMNIVIEW 360 LED he has a large ring OMNIVIEW 360 LED indicator to see detector status easily. Red Alarm Yellow rouble Green Startup Blue Remote-est Self-est Function he previous model has two LEDs on the frame. he has self-test function that checking lens condition or circuit status either automatically or manually to detect trouble condition. hat is effective in preventing false alarms. he automatic self-test cycle is adjustable to either every 1 hr, 12 hrs or 1 week to meet with peripheral environment. Lens (sensor) Yellow light indicating when Lens or ircuit has trouble LED indication for each status Normal est Function Detector Status Output Signal LED Indicator Manual est Normal Fire Red (steady) (By remote test Lens Stains rouble Yellow (steady) switch) ircuit rouble rouble Yellow (steady) Normal - Off Automatic est Lens Stains rouble Yellow (steady) ircuit rouble rouble Yellow (steady) Dust Water ondensation Selectable Self-est ycle Self-est ycle Every 1 hr Every 12 hrs Every 1 week Off *Selectable by a dedicated setting tool. Default setting is 12 hrs. Page 3 of 5 -DA-00 Rev.0

ypical Wiring Dedicated ontrol Panel Fire ommon Zone 1 rouble 24 VD+ est L K I + *1 White Black Green Red Yellow Brown Blue Y X I + K L *2 Fire ommon Zone 2 rouble 24 VD+ est L K I + *1 Dedicated fire alarm panel 1PQ1-FLD-nL+L etc. Junction Box Y X I + K L *2 ypical onventional ontrol Panel *1 Install a wire jumper between the terminals connected to Brown and Blue wires. *2 he has a built-in End-of-Line device (RE) in its enclosure. hus, the number of connectable detector is one per each zone. 1PM2, etc. Ln Zone n (-) ypical conventional fire alarm control panels, such as 1PM2, 1PV0. o Next LP06 or EOL*1 Lin in Lout out LP06 L1 K1 I+ X1 Y1 L2 K2 X2 Y2 24G (Black) (Black) GND 24 VD External Power Supply Isolated, Regulated and Power limited NFU-7000 Addressable ontrol Panel *1 A RE End-of-Line Device must be installed at the last LP06 in the Ln and circuit. From Panel or Previous Device Loop Loop o Next Device EVA-ZMU-SI Lin+ Lin- Lout+ Lout- A+ A- o Next LP06 or EOL*1 Lin in Lout out LP06 L1 K1 I+ X1 Y1 L2 K2 X2 Y2 24G (Black) (Black) GND UL listed 24 VD Power Supply Isolated, Regulated, Power limited, Listed for Battery Backup *1 A 10 kω End-of-Line Resister must be installed at the last LP06 in the A+ and A- circuit. Page 4 of 5 -DA-00 Rev.0

Example of Applications Applications Ironworks plant Printing factory Waste incineration plant hemical factory Solutions Fire monitoring for the place where may become hot by motors Fire monitoring for the large printing machine which uses organic solvent Monitoring for waste which may fire spontaneously in waste storage (orrespond to high-ceiling place) Monitoring for waste storage which may fire spontaneously Ironworks Plant Specifications Specifications Rated Voltage Operating Voltage Rated urrent Operating urrent Sensitivity / Detection Range (for 0.1 m 2 n-heptane pan fire) Response ime 24 VD 19.2 VD to 33.6 VD L - K - : 50 ma : 50 ma I : 6 ma (quiescent), 40 ma (max.) L - : 10 μa and less K - : 10 μa and less High Middle Low : 60 m (default) : 30 m : 15 m Instant : approx. 4 sec. Fast : approx. 8 sec. Normal : approx. 15 sec. (default) Prudent : approx. 30 sec. Field of View Horizontal 100, Vertical 100 LED Indicator Automatic Self-est ycle Operating emperature Exclosure Rating Dimensions Weight Material onnectable Fire Alarm Panel Optional Accessory Alarm : Red (steady) rouble : Yellow (steady) Remote est : Blue (flashing) Startup : Green (flashing) Normal : Off Adjustable to every 1 hr, 12 hrs (default), 1 week or OFF -20 to +60 IP66 (Dust-proof, Water-proof / IP67 (Dust-proof, Submersion-proof) W 120 mm x H 145 mm x D 206 mm (with Mounting Bracket) Approx. 1.5 kg (with Mounting Bracket) Body : Aluminum alloy (painted in dark bronze) Window : Sapphire Bracket : Stainless Steel Directly With LP-06 With ZMU and LP-06 ME2-RD: Flame Detector esting Device DRD-14A: Weather-proof Hood : 1PQ1-FLD-nL+L : 1PF, 1PK, 1PM, 1PN, 1PQ, 1PS, 1PV, etc. : NFU-7000, NFU-7000-L Page 5 of 5 -DA-00 Rev.0