Meeting the Challenges of the EU HFC Phase-Down

Similar documents
Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

International New Technology and Refrigerant Symposium

The impact of legislation and trends for the industry

Overview of New Refrigerants and Expected Market Trends

Retrofitting Existing Systems

Grow your business: Get ready for flammable refrigerants!

Refrigerants & Cooling in renovation buildings

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

European Experience in Certification of competence in ODS substitutes: F-gas and Alternative Refrigerants. Pune, 5 th March 2015

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Natural refrigerant trends in EU, Japan & North America

Legislation & Standards

Understanding Applications for Alternative Refrigerants

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Guidance for Stationary Refrigeration & Air-Conditioning

Refrigerant and Energy Regulations Update

Understanding Applications for Alternative Refrigerants

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

The link between safety standards and legislation:

Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Effectively Managing the Transition to Lower GWP Refrigerants

Flammability and the Low GWP Refrigerant Challenge

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

market trend update on industrial & light-commercial refrigeration

FACT SHEET 6 Transport Refrigeration

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

Alternative Refrigerants Part 1 Future and Current Options. Overview

The Current Path of Refrigerants

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Making equipment decisions

Update on Opteon Refrigerants

Embraco Position Paper: Light Commercial Refrigeration

world natural refrigerants trends market availability, technology trends & the impact of policy

ECOS Position Paper: Further recommendations

Information Guide Maintenance and Refrigerant Regulations. Issue 35

natural refrigerants - global trends & developments

In this issue. RAC equipment use up/ refrigerant leaks down. Access Canberra Safety Alert 065 Gas Explosion

Possibilities of the RAC sector transformation a technical perspective

DOE and EPA Impacts to Commercial Refrigeration

Consolidated Workshop Proceedings Report

A2L Refrigerants. Objectives 14/09/2017

AIRAH Victoria Refrigerants Update

Overview of refrigerant alternatives in the air conditioning sector *

Effectively Managing the Transition to Lower GWP Refrigerants

PHASE-IN of natural refrigerants. Prof. Dr. Armin Hafner NTNU Norway

Large AC units using a variety of low-gwp options

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

Flammability and New Refrigerant Options

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Consolidated Workshop Proceedings Report

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Guidance Note EC Regulation No 842/2006 on Certain Fluorinated Greenhouse Gases. BFPSA Guidance for the Fire Protection Industry

Refrigerant & Energy Regulations Update

Description of the European standard EN 378: Refrigerating systems and heat pumps Safety and environmental requirements

Low GWP alternative refrigerants to R404A

The Global E-waste Monitor 2017

Reducing Refrigerant Leakage

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

Refrigerants Management & Retrofits. Mike Saunders & Randy Tebbe Emerson Climate Technologies

Training and certification experience in Europe and opportunities in Hot Countries Tunis, 25th October 2016

New Refrigerants & Selecting Capital Equipment

Ammonia. Background on ammonia as a refrigerant

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Information for practitioners 5. Refrigerant selection guidelines. An overview of the refrigerants of the future.

Refrigerant options now and in the future

Challenges from flammability concerns and related safety standards, possibilities for compact systems limiting charge sizes

Business and Economic Potential of Resource Recovery and Recycling from E-waste

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

SOLSTICE L40X (R-455A)

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

Making Sense of the Latest Rulemaking on Acceptable Refrigerants. E360 Webinar

Chillers for High Ambient Conditions: What Technologies and Fluids?

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

INDUSTRIAL REFRIGERATION. Position on refrigerant selection

Position of ECOS, EEB, Friends of the Earth Europe, WWF EPO and INFORSE Europe

The Case for R-290 in U.S. Commercial Foodservice

Refrigerant options now and in the future

Sanhua accepts the challenge of new low-gwp refrigerants

see notes on refrigerant type Refrigerant Type ASHR AE Refrigerant Composition (Mass % ) Zeotropes

BETTER URBAN PLANNING

The Indian Scenario and Challenges about E-waste

Natural Refrigerants.

LATEST HYDROCARBON-BASED REFRIGERATION TRENDS

The 10 th Three Associations Meeting JRAIA. The Japan Refrigeration and Air Conditioning Industry Association. August 31, 2016.

Responsible Care Product Stewardship for Refrigerants

Honeywell Refrigerant Update

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

EXHIBIT G REFRIGERANT MANAGEMENT POLICY

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

Published in March 2005 by the. Ministry for the Environment. PO Box , Wellington, New Zealand ISBN: X.

Refrigerant and Energy Regulations Update

New Refrigerants Designation and Safety Classifications

Requirements for the Collection, Transportation, Storage and Treatment of Cooling and Freezing Appliances containing Hydrocarbons (HC)

Chapter 2. Alternatives to HCFCs and their Characteristics

Exhibition Hall 1. Fachprogramm. Technical Programme

Navigating a changing refrigerants market

4: Leakage matters: for service and maintenance contractors

Transcription:

EPEE Meeting the Challenges of the EU HFC Phase-Down EPEE Gapometer Project Key Messages November 2017

Background The EU F-Gas Regulation creates massive cuts in the CO 2 equivalent amount of HFC refrigerants that can be placed on the EU market. This reduction scheme is regulated by a quota system. The first big cut in HFC quota is in 2018. The EPEE Gapometer Project provides important insights into the actions required to meet the challenging HFC phasedown targets. A Roadmap was developed in 2015 to highlight how these targets could be achieved. Market monitoring is being carried out to identify whether the necessary actions are being undertaken quickly enough for the targets to be met. 2

The scale of the challenge The cut in HFC quota in 2018 will be 37% of the baseline amount (the baseline represents historic HFC consumption in the EU). Taking pre-charged imports into account, the actual cut in 2018 will be 44%. In 2021 there will be a further big cut an overall reduction of 60%. These cuts are measured in tonnes CO2 equivalent, to encourage: (i) the use of refrigerants with a lower GWP (global warming potential), (ii) the reduction of the amount of virgin HFCs placed on the market and (iii) the recovery and reclaim of HFCs. Key risks for end-users The severe cut of HFC quota will lead to significant price increases for HFC refrigerants, especially those with a very high GWP, such as R-404A and R-507. An important consideration is that the availability of these very high GWP refrigerants could become very limited. This situation will occur if stakeholders do not take sufficient action to reduce HFC demand. How the challenge can be met: The EPEE Gapometer Roadmap shows that it will be possible to meet the HFC phase-down targets, but only if a wide range of stakeholders take appropriate actions to reduce HFC demand as a matter of urgency. The Roadmap shows the relative size of the required actions by considering a number of core actions that must be undertaken. The core actions include four crucial measures: Use of lower GWP refrigerants in new equipment Reduction of leakage from existing equipment Retrofit of high GWP refrigerants in certain types of existing equipment Recovery and reclaim of waste refrigerant EU HFC Quota Pre-charged imports Million tonnes CO 2 equivalent 200 150 100 50 0 Baseline 2018 2021 3

Cuts in MT CO 2 Million tonnes CO2 equivalent 200 150 100 New Equipment Existing Equipment Refrigerant Re-use 50 0 Baseline 2018 2021 The required actions are sector specific: The EPEE Roadmap clearly shows that the phase-down actions vary between different parts of the market. In some market sectors, the emphasis will be to ensure that all new equipment is using lower GWP refrigerants than the traditional HFCs. In other market sectors, there also needs to be significant action related to existing equipment, especially leak prevention and refrigerant retrofit. Energy efficiency, safety and cost are vital considerations: A switch to a lower GWP alternative must not compromise energy efficiency or safety and should not incur excessive cost. What is the outlook for 2018-2021? The recent market analysis carried out by EPEE shows some encouraging progress in certain market sectors and in some geographic regions. However, the research shows that across the whole EU there are significant gaps between the Roadmap requirements and the level of overall activity. Unless there is a significant increase in the uptake of the core actions in the short-term, it is predicted that there could be a severe shortage of some HFC refrigerants in 2018. 4

Key Messages New equipment Lower GWP refrigerants are already available for most RAC applications - BUT uptake of lower GWP options is slower than required End users must be strongly encouraged to avoid using high GWP traditional HFCs OEMs / equipment suppliers must make lower GWP options available Some lower GWP options involve flammable refrigerants - Training, the development and use of safety standards and the update of national building codes are urgent priorities Advisors play an important role and must understand the lower GWP options - Some advisors, such as building service consultants and refrigeration contractors, are not yet fully aware of the need for lower GWP refrigerants or alternative design configurations Existing Equipment Leakage reduction is important, especially in larger systems - Supermarkets are a key sector historically they had high leak rates - There is good evidence of progress by best-practice supermarkets, reducing leaks from over 20% per year to well under 10% - BUT there is a lack of progress in some supermarket companies and Member States Retrofit of R-404A systems is a crucial contributor to phase-down targets - Supermarkets have embraced this opportunity in some EU countries - BUT greater adoption of retrofits across the EU is urgent to meet 2018 targets - R-404A (GWP 3922) can often be replaced by refrigerants with GWP below 1500 - Maximising recovery and reclaim of R-404A Industrial users of HFC systems must also consider leakage and retrofits - BUT industrial users are well behind supermarket sector in relation to these issues Refrigerant Reclaim Reclaim of refrigerant makes an important contribution to HFC phase-down - Recycled or reclaimed HFCs are not accounted for in the phase-down quotas - The EPEE Roadmap shows they can provide over 25% of the required cut in 2018 Drivers for recovery and reclaim will grow quickly - Historically there was relatively little HFC reclaim as virgin HFCs were low cost - Higher refrigerant prices and shortages of high GWP gases will encourage reclaim RAC contractors and end users need to maximise refrigerant recovery - At equipment end-of-life and when R-404A equipment is being retrofitted - This is a legal requirement, BUT some contractors do not comply with current rules The gas supply chain needs to provide supporting infrastructure - By providing: (a) easy access to recovery cylinders, (b) easier transport of waste gas between countries and (c) facilities for reclaim of both unmixed and mixed batches of refrigerant - There is good infrastructure in a few Member States, but significant work is needed in 2017 and 2018 to maximise refrigerant reclaim 5

EPEE Retail Refrigeration Key influencers New equipment Large retail chains: in-house experts working at head office level. It is important that the in-house experts have a clear strategy to address each of the core actions described below. Small retailers: OEMs, suppliers and installation / maintenance contractors. Advisors from suppliers and contractors play a key role helping small retailers understand the F Gas Regulation. It is important that they explain the relevant core actions to retailers. Avoid R-404A and R-507A in all new refrigeration equipment, with immediate effect. Use ultra-low GWP options (such as CO 2, hydrocarbons and HFOs) where possible, taking into account safety, energy efficiency and costs. These are already available and cost effective for large central systems and for small stand-alone systems. Cost effectiveness for medium sized systems is rapidly improving. Also consider alternative design configurations (e.g. indirect systems or stand-alone systems). 6

Leak reduction Ensure minimisation of leakage from existing refrigeration equipment. Central multi-pack supermarket refrigeration systems have historically high leakage rates. Leak reduction is particularly important in the retail sector. A well-managed leak reduction initiative can reduce leak rates by well over 50%. Maintenance contractors must be incentivised to address the leakage issue. Regular reporting of refrigerant use is important to monitor improvements. Individual systems that leak particularly badly need extra attention and investment. Retrofit of existing R-404A systems Most supermarket companies have a large bank of R-404A in existing equipment. Obtaining R-404A to maintain these systems will become nearly impossible from 2018. Using virgin R-404A for servicing systems is banned from 2020 (systems > 10kg). Retrofit of R-404A systems is an important risk mitigation measure for supermarkets. It will make a significant contribution to EU HFC phasedown targets. Waiting for the 2020 service ban is not appropriate there is too much risk of R-404A short age in 2018. Various non-flammable refrigerants suited to retrofit of R-404A are available. Energy efficiency improvements of > 5% are reported by several companies that have completed retrofits this provides a positive financial driver for retrofits. The value of recovered high GWP refrigerant can be an additional incentive for the end user. Use of recycled and reclaimed refrigerant Recycled and reclaimed refrigerants are not included in the HFC phase-down quotas and can provide an important source of refrigerant supply at times when HFCs are in short supply. Recovery of waste refrigerant (at end-of-life or during a refrigerant retrofit) is a legal requirement under the EU F-Gas Regulation. Retail sector users should ensure compliance with this requirement and should encourage their contractors to maximise gas recovery. Historically most recovered gas was incinerated. This is no longer the best option. All recovered gas should be either recycled or sent for reclaim. Different refrigerants should not be mixed with each other in recovery cylinders. Supermarket companies can limit the risks of high refrigerant prices by a carefully coordinated refrigerant management programme based on the use of recycled or reclaimed refrigerant from equipment reaching end-of-life and from retrofits of existing systems. The potential value of the recovered high GWP refrigerant can be a significant incentive for the end-user. 7

EPEE Building Air-Conditioning 8 Key influencers Large buildings: building services consultants. Most air-conditioning systems for large buildings are specified by design consultants. Many are still specifying traditional HFCs, ignoring the lower GWP options that are becoming available. Building designers need to be encouraged to specify lower GWP solutions. Small buildings: OEMs, suppliers and installation / maintenance contractors. Advisors from suppliers and contractors play a key role helping small building owners understand the F-Gas Regulation. It is important that they explain the relevant core actions to users. New AC equipment: Water chillers For medium to large size water chillers, R-134a is today the leading refrigerant in Europe. Various ultralow GWP refrigerants are becoming available, for example R-1234ze/yf and R-516A (safety class A2L) for medium pressure chillers and R-1233zd (safety class A1) or R-514A (safety class B1) for low pressure chillers. Propane (R-290) and ammonia (R 717) can also be considered for higher pressure chillers but may have application limitations due to safety constraints (propane: higher flammability, class A3; ammonia: higher toxicity, class B2L). Non-flammable alternatives are avail able with a moderate GWP (around 600), including R-513A and R-450A. For smaller chillers, R-410A is the leading fluid. Potential alternatives with lower GWP (in range 100-750) are being proposed, like the HFC R-32 or the blends R-452B and R-454B. All these alternatives to R-410A are mildly flammable (class A2L). Despite the rapidly increasing availability of ultra-low GWP options, their uptake is still slow. OEMs, equipment suppliers and designers must be encouraged to offer lower GWP options while continuing to take into account safety and energy efficiency. Given the long life of water chillers, end users must be encouraged to avoid high GWP refrigerants in new chillers.

Leak reduction Ensure minimisation of leakage from existing air-conditioning equipment. Most air-conditioning equipment have low levels of leakage. Large instal lations should be regularly checked for leakage and records kept of the quantities of refrigerant used for top up of leaks. Any large leaks are required to be repaired as soon as possible. Retrofit of existing AC Retrofit of existing air-conditioning equipment to lower GWP gases is not yet being undertaken, but certain non-flammable blends (e.g. R-450A or R-513A) can be considered for retrofit of R-134a systems. New AC equipment: DX systems Small split systems: Until recently most split systems have used R-410A (GWP 2088). There is no ultra-low GWP option currently available in the EU for split air-conditioning. Moderate GWP options such as R-32 (GWP 675) and certain HFO/HFC blends are now available and should be used where possible. These new moderate GWP options have lower flammability (safety class A2L). This could limit application in certain circumstances. Larger DX systems including VRF and packaged roof-top units: Currently the main option for large VRF systems is R-410A. Because of flamma bility constraints in large systems lower GWP alternatives are not currently available. Product developments are underway and VRF systems using A2L refrigerants such as HFC-32 or HFC/HFO blends may be introduced in the future. For packaged roof-top units, A2L refrigerants such as R-32, R-452B and R-454B can be considered. Use of recycled or reclaimed refrigerant Recycled or reclaimed refrigerants are not included in the phase-down quotas and can provide an important source of refrigerant supply at times when HFCs are in short supply. Recovery of waste refrigerant at end-of-life is a legal requirement under the EU F-Gas Regulation. Building air-conditioning end users should ensure compliance with this requirement and should encourage their contractors to maximise gas recovery. Historically most recovered gas was incinerated. This is no longer the best option. All recovered gas should be either recycled or sent for reclaim. Different refrigerants should not be mixed with each other in recovery cylinders. 9

EPEE Industrial Refrigeration Key influencers New equipment Large factories: in-house experts working at head office level. It is important that the in-house experts have a clear strategy to address each of the core actions described below. Small factories: OEMs, suppliers and installation / maintenance contractors. Advisors from suppliers and contractors play an important role helping small industrial refrigeration users understand the F-Gas Regulation. It is important that they explain the relevant core actions to users. Avoid R-404A and R-507A in all new refrigeration equipment. Large flooded or DX systems: Use ultra-low GWP options (such as ammonia, CO 2, hydrocarbons and HFOs) where possible. Ammonia systems are widely used in many industrial applications. CO 2 is growing in popularity, especially for the low stage of cascades, in combination with other solutions for the high stage (such as ammonia). Industrial chillers: Ammonia is often suitable. Ultra-low GWP HFOs such as R-1234ze/ yf, R- 1233zd and R-516A are becoming available. Smaller DX systems: To avoid R-404A or R- 507A, various non-flammable medium GWP options are available (e.g. R-448A, R-449A, R-449B, R-407A, R-407F, R-407H, R-452A). New HFO/HFC blends with a small level of flammability (safety category A2L) are becoming available and may be suitable in many industrial applications. 10

Leak reduction Ensure minimisation of leakage from existing re frig eration equipment. Industrial refrigeration systems have historically high leakage rates. A well-man aged leak reduction initiative can reduce leak rates by well over 50%. Maintenance contractors must be incentivised to address the leakage issue. Regular reporting of refrigerant use is important to monitor improvements. Systems that leak particularly badly need extra attention and investment. Retrofit of existing R-404A systems Many existing industrial systems use R-404A. Obtaining R-404A to maintain these systems will become nearly impossible from 2018. Using virgin R-404A for servicing systems is banned from 2020 (the ban applies to any R-404A system containing > 10kg of refrigerant). The service ban also applies to other refrigerants with a GWP above 2500 e.g. R-507A and R-434A. Retrofit of R-404A systems is an important consideration for industrial refrigeration users. Waiting for the 2020 service ban is not appropriate there is too much risk of R-404A shortages in 2018. Various non-flammable drop-in replacements for R-404A are available for retrofit of direct expansion systems. Energy efficiency improvements of > 5% are reported by several companies that have completed retrofits this provides a positive financial driver for retrofits. Retrofit of large flooded systems is not usually recommended. Use of recycled or reclaimed refrigerant Recycled or reclaimed refrigerants are not included in the phase-down quotas and can provide an important source of refrigerant supply at times when HFCs are in short supply. Recovery of waste refrigerant (at end-of-life or a refrigerant retrofit) is a legal requirement under the EU F-Gas Regulation. Industrial refrigeration users should ensure compliance with this requirement and should encourage contractors to maximise gas recovery. Historically most recovered gas was incinerated. This is no longer the best option. All recovered gas should be either recycled or sent for reclaim. Different refrigerants should not be mixed with each other in recovery cylinders. Industrial companies can limit the risks of high refrigerant prices by a carefully coordinated refrigerant management programme based on the use of reclaimed refrigerant from equipment reaching end-of-life and from retrofits of existing systems. 11

EPEE RAC Installation and Maintenance Contractors Role as a Key influencer RAC contractors play a very important role in advising their clients about the impact of the EU F-Gas Regulation. It is essential that contractors keep up-to-date with the latest technical developments so that they can provide the best advice about the core actions required to ensure that HFC phase-down targets are met. New equipment Contractors should encourage their customers to use lower GWP options where available. During the life of equipment purchased in 2017 or 2018 there will be a significant reduction of HFC quota (a 60% cut by 2021, rising to a cut of nearly 80% by 2027). It makes commercial sense to change to alternatives in new equipment where possible. There is a rapid rate of development of new RAC products using lower GWP refrigerants. RAC contractors need to ensure they are recommending the optimum refrigerant and system design configuration. Avoid using R-404A and R-507A in all new refrig eration equipment, with immediate effect. Ultra-low GWP refrigerants are available in many RAC sectors including retail refrigeration, industrial refrigeration and water chillers. Moderate GWP refrigerants should be considered in some markets e.g. R-32 in split air-conditioning systems. 12

Leak reduction Contractors should ensure minimisation of leakage from existing refrigeration equipment that they are maintaining. This is especially important in larger distributed systems such as supermarket central systems and industrial systems. A well-managed leak reduction initiative can reduce leak rates by well over 50%. Maintenance contractors should encourage customers to invest in leak prevention. Systems that leak particularly badly need extra attention and investment. There is a legal requirement to regularly test systems for leakage (except very small systems) and a legal requirement to repair any leaks that are identified. Both end users and their maintenance contractors could be prosecuted if they do not comply with these rules. Retrofit of existing R-404A systems A refrigerant retrofit should be considered for existing refrigeration systems using R-404A. Obtaining R-404A to maintain these systems will become nearly impossible from 2018. Using virgin R-404A for servicing systems is banned from 2020 (systems > 10kg). Retrofit of R-404A systems is an important risk mitigation measure for supermarkets and industrial refrigeration users. Waiting for the 2020 service ban is not appropriate there is too much risk of R-404A shortage in 2018. Various non-flammable drop-in replacements for R-404A are available for retrofit of direct expansion systems. Energy efficiency improvements of > 5% are reported by several companies that have completed retrofits this provides a positive financial driver for retrofits. Retrofit of large flooded systems is not usually recommended. Use of recycled or claimed refrigerant Recycled or reclaimed refrigerants are not included in the phase-down quotas and can provide an important source of refrigerant supply at times when HFCs are in short supply. Recovery of waste refrigerant (at end-of-life or a refrigerant retrofit) is a legal requirement under the EU F-Gas Regulation. RAC contractors should ensure compliance with this requirement and max imise gas recovery. Historically most recovered gas was incinerated. This is no longer the best option. All recovered gas should be either recycled or sent for reclaim. Different refrigerants should not be mixed with each other in recovery cylinders. 13

EPEE Member State Governments Stakeholder Engagement Officials responsible for implementation of the EU F-Gas Regulation should provide support and information to stakeholders, to ensure they are aware of key aspects of the Regulation and the potential risks of a shortage of HFC refrigerants in 2018. Key stakeholders include: Major end users, including supermarkets and industrial companies RAC equipment manufacturers and importers Advisors such as design consultants and building service engineers RAC installation and maintenance contractors Government officials should take urgent action to remove unnecessary restrictions in building codes that currently prevent alternatives to be used, by updating their building codes and aligning them with the EU product safety legislation (low voltage directive, machinery directive). New equipment End users must be encouraged to use lower GWP refrigerants where available and possible. During the life of equipment purchased in 2017 or 2018 there will be a significant reduction of HFC quota (a 60% cut by 2021, rising to a cut of nearly 80% by 2027). It makes commercial sense for end users to stop using high GWP HFCs in new equipment where possible. Officials should take urgent actions to align national and local building codes with EU refrigeration safety standards and product legislation to remove market barriers. Regular information updates will help stakeholders understand the availability of lower GWP refrigerants. Such information needs to be customised for different types of stakeholders. 14

Leak reduction End users and maintenance contractors must be encouraged to minimise leakage from existing refrigeration equipment. This is especially important in larger distributed systems such as supermarket central systems and industrial systems. A well-managed leak reduction initiative can reduce leak rates by well over 50%. End users and contractors should be reminded that it is a legal requirement to regularly test systems for leakage (except very small systems) and to repair any leaks that are identified. Government officials should consider policy initiatives that will incentivise compliance with these aspects of the F-Gas Regulation. Retrofit of existing R-404A systems End users must be encouraged to consider refrigerant retrofits for any large refrigeration systems using R-404A. Obtaining R-404A to maintain these systems will become nearly impossible from 2018. Using virgin R-404A for servicing systems is banned from 2020 (systems > 10kg). Retrofit of R-404A systems is an important risk mitigation measure, particularly for supermarkets industrial refrigeration users. Waiting for the 2020 service ban is not appropriate there is too much risk of R-404A shortage in 2018. Various non-flammable refrigerants suited to retrofit of R-404A are available. Energy efficiency improvements of > 5% are reported by several companies that have completed retrofits this provides a positive financial driver for retrofits. Retrofit of large flooded systems is not usually recommended. Use of recycled and claimed refrigerant Recycled and reclaimed refrigerants are not included in the phase-down quotas and can provide an important source of refrigerant supply at times when HFCs are in short supply. Recovery of waste refrigerant (at end-of-life or a refrigerant retrofit) is a legal requirement under the EU F-Gas Regulation. Policy measures should be considered to ensure that end-users and RAC contractors comply with this requirement and maximise gas recovery. Officials need to review the availability of refrigerant recycling and reclaim infrastructure and help ensure that reprocessing options are available to all end users in each Member State. They should also facilitate cross border shipments of waste to allow for recycling or reclaiming activities in other regions. 15

EPEE The voice of the refrigeration, air-conditioning and heat-pump industry in Europe About EPEE The European Partnership for Energy and the Environment (EPEE) represents the interests of the refrigeration, air-conditioning and heat pump industry in Europe. Founded in the year 2000, EPEE s membership is composed of 47 member companies, national and international associations from Europe, the USA and Asia, employing more than 200,000 people in Europe and realising a turnover of over 30 billion Euro. EPEE European Partnership for Energy and the Environment Avenue des Arts, 46 1000 Brussels Tel : +32 (0) 2 732 70 40 Fax : +32 (0) 2 732 71 76 secretariat@epeeglobal.org www.epeeglobal.org Follow us on Twitter @EPEESecretariat 2017 EPEE ALL RIGHTS RESERVED