DIESEL Engine Fire Pump Controllers Features

Similar documents
DIESEL Engine Fire Pump Controllers Features

FDF Foam Pump Controllers Features

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

Transfer Switch Features

LMR Electric Fire Pump Controllers Features

LMR Electric Fire Pump Controllers Features

Transfer Switch Features

FT60 Reduced Voltage - Autotransformer

Fire Pump Controllers Foam (Additive) Controllers

Remote Alarm Panels Features

FD30 Full Voltage - Across the Line July 2011

Customer Connection Terminals Connection terminals for external customer connections, are located at the top of the Power I/O board.

Variable Frequency Drive SERIES MP800 VFD

Fire Pump Controllers Medium Voltage Controllers

FT40 Reduced Voltage - Part Winding. Electrically and Mechanically

FT20 Full Voltage - Limited Service. Electrically and Mechanically

Across-the-Line SERIES MP300 Combined Manual and Automatic

Soft Start Series MP700 Solid State, Reduced Voltage

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

Technical Data Submittal Documents

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Centro-Matic Automated Lubrication Systems System Controls

TECHNICAL DATA. multi-hazard. model vfr400. Release Control Panel 290a. January 16, 2014

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Drawing Submittal Package

DGC-500 DIGITAL GENSET CONTROLLER

DGC-1000 DIGITAL GENSET CONTROLLER

FDJ SERIES Jockey Pump Controllers Features

EATON DFDAP-M / FDAP-M Remote Alarm Panels

Drawing Submittal Package

NS (A) ECN

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Technical Data Submittal Document

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

EATON LMR Plus Electric Fire Pump Controllers

FTA550 JOCKEY PUMP CONTROLLERS

Oxygen (O2) Single-Point Gas Detection System

Installation Guide for models:

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Installation Guide for models:

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

MANUAL FOR MODEL FD4 FIRE PUMP CONTROLLERS

Conventional Releasing Control Panel

DIESEL ENGINE CONTROL UNIT DCU USER S MANUAL - N-2000 Lillestrøm, Norway Tel: (+47) Fax: (+47)

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

AS950 REFRIGERATED SAMPLERS

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

La Marche Manufacturing Company Option 46 Series. Digital Combined Accessory Package. Installation and Operation Manual

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

B. Section Transfer Switches: Automatic transfer switch.

Specification/ Data Sheet

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

AS950 PORTABLE SAMPLERS

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

Guide Specification Model CTG Automatic Transfer Switch

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

TECHNICAL DATA OBSOLETE

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

Combustible Gas Detection and Control System

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

SPECIFICATION MICROMIST FIRE SUPPRESSION SYSTEM WITH SHP-PRO CONTROL PANEL

Fire Pump Controller. For Electric Motor Driven Fire Pumps. Wye Delta Reduced Current Types

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

Series. Access Power Controllers. Installation Guide

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

AS DIGITAL FIRE PUMP CONTROLLER

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

AL802ULADA. NAC Power Extender. Installation Guide. (See Application Guide for additional information) Rev

AL800ULADA. NAC Power Extender. Installation Guide

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

INTELLIGENT FIRE ALARM CONTROL PANEL

Smart Temp. ApolloP/n Installation Manual. Version 1.0

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

University of Houston Master Construction Specifications Insert Project Name SECTION FIRE PROTECTION PUMPS PART 1 - GENERAL

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Two-Channel Gas Controller

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

SP-1000X. Panic Device Power Controller Installation Guide. Rev

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Commercial and Light Industrial Fire Alarm Control Panel

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Technical Data Submittal Documents

21-light Remote Annunciator. Owner s Manual

Tempco Part Number PCT30006 Temperature Control Enclosure with Relay Output for Tote Tank Heating Applications

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

CONVENTIONAL FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels MEA. Features. Description

AT10.1 Series Microprocessor-Controlled Float Battery Charger (single phase input)

Transcription:

September 007 DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers 1-1 Printer / Recorder The industrial grade thermal printer is housed in a rugged steel enclosure within the controller. The on/off switch, feed and reset buttons are front accessible. A bi-color status LED is also visible on the front of the printer. Green indicates - Printer Operational while yellow indicates - Out of Paper. Engine Crank Cycle Upon detecting a drop in system pressure, the microprocessor sends a start signal to the engine, initiating its crank cycle. The crank cycle consists of six periods of 1 second duration, separated by five rest periods of 1 second duration alternating on each set of batteries. If the engine does not start within this cycle, an audible and visible Fail to Start alarm is activated. Should voltage of either battery fall below 67% of normal during the crank cycle, a Battery Failure alarm will be activated and the FD0 will alter the cranking sequence by continuing the process with the remaining good battery. The crank cycle terminates when the engine starts. The FD0 continues to monitor the batteries and engine for conditions such as: water temperature, oil pressure and speed (RPM). Product Description The FD0 Diesel Engine Controller is designed to control and monitor 1 or volt, diesel fire pump engines. All models are listed by UL and ULC, and approved by Factory Mutual and CSA, as well as meeting or exceeding the requirements of NFPA 0 and NFPA 70. Product Features Microprocessor Control EATON Cutler-Hammer FD0 Diesel Engine Fire Pump Controllers are microprocessor based. All events surrounding the operation of the controller are stored within the memory, thus giving the ability to diagnose and troubleshoot problems based on an actual history of events. Events are time and date stamped. A main display unit provides a read-out of parameters such as current pressure, volts and amps and will display error messages as well as provide alarm indication. A status report is available which can be printed locally. The status reports provide a record of the state of the controller as it was left after commissioning. Pressure Transmitter: 0. -.V Each diesel engine controller is equipped with a plug-in style, 0. to. volt pressure transmitter. Run Period Timer The run period timer is built into the FD0 microprocessor and can be accessed via the membrane / keypad. It is programmable from 0-60 minutes and should be reset to thirty (0) minutes when the controller is placed in service. Last Messages The internal microprocessor stores the most recent messages in it s memory. The messages can be printed, viewed on the LCD screen or downloaded to a computer. Each message is time and date stamped. The LCD display acts as a paperless chart recorder. Common Alarm Relay The FD0 controller has a common alarm relay which energizes whenever there are any alarm conditions present. This relay is energized under normal conditions and has LED status indication. Additional Output Relays Two additional output relays labeled Future #1 and Future #, can be user programmed to operate for ten () different functions. Programming is done in the FD0 menu using the membrane / keypad. Alarm Relay Ratings All alarm relays are rated at Amps, 0VAC 1/HP resistive load only. NEMA Enclosures All FD0 controllers come standard with NEMA enclosures unless otherwise ordered. Available options include: NEMA R,, X, 1. AC Power Failure The FD0 microprocessor retains a record in it s memory whenever AC power is applied / restored to the controller. The LCD display indicates the message AC Power OK. Weekly Test Timer Each diesel controller is equipped with a Weekly Test Timer, hour clock, to automatically exercise the engine once a week for the time specified as per NFPA Pamphlet No. 0. Relay Board The FD0 Relay Board is clearly labeled with pullapart terminal blocks for ease of wiring and connections. All relays are labeled with full description as well as corresponding three letter designation as indicated on the wiring diagram. A visual LED indicates the energized state of the relay. All plug-in relays are identical PDT, allowing complete interchangeabilty. All terminal numbers are indicated on both the stationary and moveable portion of the terminal blocks. Pump Room Trouble and Engine Trouble common alarm relays are standard. BR0006K/B

1- DIESEL Engine Fire Pump Controllers Features FD0 Diesel Engine Controllers September 007 Product Features Alarm & Status Indication The display panel is equipped with sixteen indication LED s which indicate various functions and operations of the controller. They are colour keyed to the urgency of the indication. Green indicates normal running conditions, Yellow indicates supervisory alarms and Red indicates critical alarms. LCD Display / Function Panel The line liquid crystal display allows viewing of all programming parameters in addition to battery and pressure information without opening the front door of the controller. Messages can also be downloaded to a laptop computer via the communications port located on the top of the main microprocessor board. Battery Chargers Three Step Charge The battery chargers incorporate a three step charge to guarantee the fastest charge times while optimizing battery life. The three steps are referred to as Bulk mode, Overcharge Mode and Float mode. Bulk In Bulk mode, a current of Amps is delivered into the battery until the voltage reaches. Volts per cell for Lead Acid Batteries. (1. Volts for a 1 Volt battery). At this point, the battery has recovered approximately 90% of its capacity. When the charger senses this state, it switches to the Overcharge mode. Overcharge In the Overcharge mode, the voltage on the battery is held at 1. Volts and the current into the battery declines. This mode is maintained until the current into the battery declines to 1. Amps. At this moment, the battery is approximately 99% charged and the charger will change to Float Mode. Float In Float Mode, the charger maintains the battery voltage at. Volts per cell for a lead acid battery (1. Volts for a 1 Volt battery). In this mode, the battery will come to 0 % charge. At the same time, any additional load on the battery system will draw its current from the charger so that the battery will not discharge due to these additional loads. This charging technique insures that the battery will not be overcharged. RS Port This port is currently not active. It is reserved for use with the Diesel Plus controller. Temperature Monitoring Internal Temperature Sensor To achieve optimal performance of the charger and to insure that the batteries are not overcharged, each charger is equipped with an internal temperature sensor which provides an ambient temperature indication. The charging parameters are altered based on the temperature readings, to provide optimal charging results. Additionally, for temperatures outside of the charging temperatures recommended by the battery manufacturers, the charger will activate an alarm. Charger Shut Down The charger will automatically shut down if there is no load connected to the output or if there is a short on the load side of the charger. In addition, the charger will not operate if a battery is connected incorrectly or if the wrong voltage of battery is connected. AC Input Fuse Protection The AC Supply is protected by a 6 amp fuse which will blow in case of a breakdown of the charger. This fuse will not blow as a result of overloading of the charger since the electronics will shutdown the charger in this event before the fuse blows. Alarm LED s Auto Mode Fail to Start Low Oil Pressure Engine Overspeed Engine Run Battery Failure Charger Failure Low Fuel Level High Fuel Level Fuel Spill High Engine Temperature Low Pump Room Temperature High Reservoir Level Low Reservoir Level Charger Fail Output A single Form C relay output will activate if the charger fails for any reason. Charger Setup: Lead Acid / Ni Cad DIP switches on the charger can be used to select a number of options including battery type and voltage as well as Alarm Latching. Options currently supported for the charger include 1 or Volt Lead Acid and NiCad Batteries. Installation / Mounting Two chargers are direct mounted to the back pan. A separate bracket, which accommodates a single charger board, can be used for retro-fitting previous models. LCD Display A single line by 16 character LCD display will alternately show: Charging Amps; Voltage; Alarms Specifications Voltage Input: 90-0VAC - Auto detect Voltage Output: 1 - VDC - DIP switch selectable Hertz: Operates on 0 / 60Hz Standards & Certification The FD0 Diesel Engine Fire Pump Controllers meet or exceed the requirements of Underwriters Laboratories, Underwriters Laboratories Canada, Factory Mutual, the Canadian Standards Association, New York City building code, are built to NFPA 0 standards and meet CE mark requirements. BR0006K/B For CE Approved Dimensional drawing - see Page 1-.

CB1 CRANK # 1 CRANK # CB CB1 CRANK # 1 CRANK # CB November 007 Diesel Engine Controllers Dimensions FD0 Diesel Engine Controller Dimensions Standard Enclosure - Type CE Approved 1. [6] 9.7 [7].17 [6] 1.00 [7].00 [].00 [1].97 [91].97 [6].97 [171].7 [7] 1.00 [7].6 [6] 1 - AUDIBLE ALARM - DIESEL MEMBRANE - CRANK BUTTONS - MAIN CIRCUIT BREAKERS - LOCKABLE HANDLES 6 - STOP BUTTON 7 - DVS DISCHARGE PIPE - PIPING ENTRANCE 1/" NPT - FEMALE 9 - CABLE ACCESS (BOTTOM ONLY) - PRESSURE TRANSMITTER 1. [1].7 [16]. [1] Dimensions in Inches and [millimeters]. Approx. Weight Lbs. (Kg) () 1.1 [9] 1.9 [7]. [] 1.7 [] NOTES: 1. All enclosures finished in FirePump red.. Cable Entrance bottom only.. Standard Enclosure type NEMA. MD0007K/B

November 006 Diesel Engine Controllers Main Display Main Display - FD0 Diesel Engine Controller Main Display AUTO MANUAL TEST OFF VOLTS AMPS PSI / BAR BATT. #1 BATT. # F1 F F MENU Silence Reset Lamp Test Time Print CB1 CRANK #1 CRANK # CB MD00076K

September 007 Diesel Engine Fire Pump Controllers Electrical Wiring Schematic FD0 Diesel Engine Controllers - CE Approved Electrical Wiring Schematic FD0 CE Approved Diesel Engine Controller ES0007K/C

GROUND NEUTRAL LINE January 007 Diesel Engine Fire Pump Controllers Field Connections FD0 Diesel Engine Controllers - CE Approved Field Connections FD0 CE Approved Diesel Engine Controller DIESEL ENGINE TERMINAL BLOCK FUEL WATER SOLENOID ENGINE RUN SW OVERSPEED SW OIL PRESSURE SW ENGINE WATER BATTERY #1 ENGINE ALT BATTERY # INPUT BATTERY #1 CRANK BATTERY # CRANK BATTERIES (-) FUEL SOLENOID DIESEL ENGINE 1 6 6 7 9 1 SEE WIRING NOTE CUSTOMER CONNECTION TO MAIN TERMINAL BLOCK FUEL WATER SOLENOID ENGINE RUN SW OVERSPEED SW OIL PRESSURE SW ENGINE WATER BATTERY #1 ENGINE ALT BATTERY # INPUT BATTERY #1 CRANK BATTERY # CRANK BATTERIES (-) FUEL SOLENOID DIESEL ENGINE 1 6 7 9 1 7 10 CUSTOMER CONNECTION DIRECT TO RELAY BOARD TERMINALS SEE WIRING NOTE FUEL WATER SOLENOID ENGINE RUN SW OVERSPEED SW OIL PRESSURE SW ENGINE WATER BATTERY #1 ENGINE ALT BATTERY # INPUT BATTERY #1 CRANK BATTERY # CRANK BATTERIES (-) FUEL SOLENOID DIESEL ENGINE 1 6 7 9 1 CUSTOMER CONNECTION TO INPUT FILTER BOARD SEE WIRING NOTE MAIN TERMINAL BLOCK 6 6A A L L N N GD 6 PO POWER ON TO DIESEL ENGINE TERMINALS SEE NOTE 7 CUSTOMER CONNECTION TO INPUT FILTER BOARDS AC POWER SUPPLY 1A MAXIMUM INPUT FILTER BOARD ES0001K/B

October 007 Fire Pump Controllers 1-1 Features FD0 Diesel Engine Fire Pump Controllers Typical Specifications 1. Approvals A. The Fire Pump Controller shall meet the requirements of the latest edition of NFPA 0 as well as meeting CE mark requirements. It shall be listed by [Underwriters Laboratories (UL)] [Underwriters Laboratories of Canada (ULC)] and approved by [Factory Mutual Research (FM)] [Canadian Standards Association (CSA)] [New York Department of Buildings (NYSB)] for fire pump service. B. The controller shall be [1 volt / volt] negative ground, for use with Diesel Engine, Model manufactured by.. Ratings A. The Controller shall have a low altitude rating of 00 to 01 meters, a standard rating of 00 to +000 meters, and a high rating of +001 to +000 meters.. Construction A. All internal components shall be front mounted and wired for ease of inspection and maintenance. All relays shall be of the plug-in type, indentical, and complete with visual indication to show that the relays are energized. The controller shall include an LCD display to indicate battery voltage and amperes as well as system pressure, in PSI or Bars. B. The controller shall have twin battery chargers meeting NFPA 0 requirements. The battery chargers shall have reverse polarity protection/ indication and be capable of recharging a completely discharged battery within hours. The chargers shall auto detect the input voltage of either 10VAC or 0VAC and shall be able to be programmed for either 1VDC or VDC output.. Pressure Transmitter A. A plug-in, 0.-.volt, solid state pressure transmitter shall be installed with a bulkhead fitting in the enclosure bottom so that all plumbing connections are made external to the controller. The controller piping and pressure system shall be rated for operation in system pressures up to 600 PSI (. kg/cm) within +/- 1.% accuracy.. Enclosure A. The controller shall be housed in a NEMA Type (IEC IP) drip-proof, powder baked finish, freestanding enclosure with wall mounting brackets. 6. Printer / Recorder A. The controller shall be equipped with a line printer-recorder, capable of operation between - 0VDC, that will produce hard copy reports of system STATUS; including time, date, weekly test time, AC Power Failure status, print and stop mode status, sequential start time, RPT setting, system pressure setpoints, charger amperes and battery voltage plus pump running status reports and alarm data. The controller shall have the capability of storing events for furtherance to the line printer-recorder. 7. Microprocessor Control A. The following parameters shall be programmable and included as standard: 1. START and STOP PSI points. STOP MODE: Manual or Auto. RUN PERIOD TIMER: 0-60 min. AC POWER FAILURE: Enable or Disable. SEQUENTIAL START TIMER: 0-00 sec. 6. WEEKLY TEST TIMER 7. PRINT MODE: Manual or Auto. PRINTER DEVIATION: 1-99 PSI 9. LANGUAGE: English/French/Spanish B. The following visual and audible alarms shall be provided: SWITCH IN AUTO FAIL TO START LOW OIL PRESSURE ENGINE RUN ENGINE OVERSPEED LOW FUEL HIGH ENGINE TEMP. HIGH FUEL BATTERY #1 FAILURE CHGR #1 FAILURE BATTERY # FAILURE CHGR # FAILURE HIGH RESERVOIR LOW RESERVOIR LOW ROOM TEMP. FUEL SPILL C. The above shall be color coded to signify the urgency of the alarms: 1. GREEN: Normal Running Conditions. RED: Critical Alarms. YELLOW: Supervisory Alarms. Output Relays A. Three () sets of alarm contacts (Form-C) rated at A, 0VAC/VDC, shall be provided for remote indication of: 1. MANUAL MODE. ENGINE RUN. OFF MODE. PUMP ROOM TROUBLE. ENGINE TROUBLE B. Two () FUTURE relays, each containing three sets of alarm contacts (Form-C) shall (each) be factory set to indicate one of the following, as per customer requirements: 1. AUTO MODE. FAIL TO START. TEST MODE. ENGINE OVERSPEED. PRESSURE START 6. LOW OIL PRESSURE 7. HIGH ENGINE TEMP.. AC POWER FAILURE 9. Manufacturer A. The controller shall be microprocessor based as manufactured by Eaton s Cutler-Hammer business unit. PS0000K/E