OPTIONAL LENS 2 FLANGE FINISH

Similar documents
80 Watts FLANGE FINISH

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

FLANGE FINISH LENS. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (provided standard)

USAI. BeveLED 2.1 Cylinder Dimming Compatibility. Lighting River Road New Windsor, NY

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

USAI. BeveLED mini WGD Dimming Compatibility. Lighting River Road New Windsor, NY

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

USAI. NanoLED MULTI Crisp White Dimming Compatibility. Lighting River Road New Windsor, NY

USAI ADJUSTABLE. Lighting

USAI. BeveLED BLOCK Dimming Compatibility. Lighting River Road New Windsor, NY

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

USAI. Basic Dimming Compatibility. BeveLED Mini. Lighting. Precision Lighting. Color Harmony River Road New Windsor, NY 12553

DATE TYPE 40 DELIVERED PERFORMANCE

PROJECT INFORMATION PROJECT

BeveLED BLOCK. Downlight BLSD5 BEVELED BLOCK DOWNLIGHT BEVELED BLOCK DOWNLIGHT - CONDUIT CUT OUT. usailighting.com/block

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts ADJUSTABLE

PROJECT INFORMATION PROJECT DATE TYPE

BeveLED 2.1 PROJECT INFORMATION

PROJECT INFORMATION FLANGE FINISH

1" Regress Trim DELIVERED PERFORMANCE - Downlight

9 Watts 12 Watts 16 Watts 24 Watts 33 Watts 36 Watts

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

PROJECT DATE TYPE. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

PROJECT INFORMATION PROJECT DATE TYPE

BeveLED BLOCK. Wall Wash BLRW5 Pendant. usailighting.com/block

PROJECT INFORMATION LENS. S Solite F Frosted C Clear N No Glass. New Construction CP Chicago Plenum 35KS 3500K, 80+ CRI.

PROJECT INFORMATION LENS. S Solite (provided standard) F Frosted. FTA BabyLED Flat. Housing. New Construction 2 FTIC BabyLED Flat 2

NanoLED NXT Cylinder LNRP3 Surface

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN10RAT - BM- MTG214-27KS LNC61-120V - DIML2 - CB27 - BOFD

BeveLED. 2.2 Retrofit 4.5 Round Downlight - B4RDRT B4RDRT. usailighting.com/beveledrt

DATE TYPE. Ordering Example: Specify trim code and housing code to order: LN25RDT - BM- MTG214-27KS LSP55-120V - DIML2 - CB27 - BOFC COLOR

SliverLED Round Downlight, 1 Regress SR11

SliverLED Round Adjustable, Wet Location SR21W

Field changeable between Trimmed / Trimless / Millwork

BeveLED Cylinder LBRP6 Surface

Field changeable between Trimmed / Trimless / Millwork

PROJECT DATE LENS. S Solite (provided standard) F Frosted. S Solite (provided standard) F Frosted HOUSING TYPE REFLECTOR

ARMSTRONG INTERSECTION DOWNLIGHTING KIT

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

BeveLED Cylinder LBRP6 Pendant

USAI. BeveLED Mini Refi t Dimming Compatibility. Lighting River Road New Windsor, NY

True Zero Conceal - Z3SA-C 3 Square Adjustable

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

Field Convertible from Trimless or Millwork to Trimmed. Trimmed - B3SCF Trimless - B3SCL Millwork - B3SCM

Classic White - 20W 2700K 3000K 3500K 4000K 2700K 3000K 3500K 4000K

*Based on 3000K, 80+ CR. Performance varies for each specifi c beamspread and color temperature. See IES fi les for exact values at usailighting.

PROJECT DATE FLANGE FINISH

Deep Regress - B4RC usailighting.com/b4rc LED COLOR CHOICES. Classic White

BeveLED Mini Trimless Acoustical - B3RDP

BeveLED Mini - B3SD 3 Square Downlight

Universal and Field Convertible - Trim Trimless Millwork. Downlight - B4SD usailighting.com/b4sd LED COLOR CHOICES. Classic White

BeveLED Mini - B3RD 3 Round Downlight

BeveLED Mini - B3RA 3 Round Adjustable

Exterior LED Cylinder Lighting To The Next Level. FCC900 Series. delivering up to 5000 LUMENS! Specification Sheet

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Exterior LED Cylinder Lighting To The Next Level. FCCSQ400 Series. delivering up to 3500 LUMENS! Specification Sheet

Nova NFTV (0-10V)* 100%-10% 1-30 ** 1-30* Nova T NTFTV (0-10V)* 100%-10% 1-30 ** 1-30* Lutron ZT. Diva DVTV (0-10V)* 100%-10% 1-30 ** 1-30* Standard

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

IHOL-6DR / IRD600 6 Gravity LED Downlight

Micro Wall Wash Trimless - MWL

IHOL-4DR / IRD400 4 Gravity LED Downlight

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

Classix 6" 6" Round Adjustable C3

Evoke Round Adjustable C3

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Classix 6" 6" Round Adjustable C3M

Evoke Square Downlight

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Grüv Flare Regressed. Recessed Linear LED

Essenza. Square Downlights

Essenza. Round Downlights

Evoke Square Adjustable HP

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Adjustable C3

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Evoke Square Downlight

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

Hornet HP. Semi-Recessed 4-Light Square Multiple

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

RFP Grand Entry Canopies Addendum 002 Issued July 16, 2013

Evoke Square Adjustable C3M

Evoke Square Adjustable HP

Performance Chart Electrical Data

Hornet HP. Round Glass Downlight

Performance Chart Electrical Data

Transcription:

Beve 5.0 MAX OUTPUT ADJUSTABLE 40 MAX OUTPUT PROJECT INFORMATION PROJECT 6231 DATE TYPE 1" Regress Beve 5.0 Max Output Recessed Adjustable- The Beve 5.0 provides maximum delivered lumens and optical performance through the optimization of thermal,optical and science in a 6 aperture. DELIVERED PERFORMANCE Beve5.0 5.0 40 Watts 60 Watts 80 Watts Max Output - Downlight Color Rendering 80+ 80+ 80+ Lumens per Watt 90 83 74 Source Lumens 3900 5400 6650 Delivered Lumens 3550 4900 6025 Center Beam Candle Power (10º) 42100 58200 72000 Color Consistency 2 Step MacAdam Ellipse Performance based on: 3000K CCT MULTIPLIER 2700K 3000K 3500K 4000K 80+ 80+ 80+ 80+ Color Rendering Index CRI CRI CRI CRI Multiplier for Lumen Output 0.91 1.00 1.00 1.09 HOW TO SPECIFY Ordering Example: Specify trim code and housing code to order: Example : 6231 - B1 - N - 10 - LRTA6-8480 - C2-27KS - 20 - NC1-277V - DIML2 - CB27 TRIM ORDERING INFORMATION TRIM 6231 6231 6 Round Adjustable LRTA6 8440 40W, 3550 lumens 8460 60W, 4900 lumens 8480 80W, 6025 lumens OPTION W Wet location 1 1 Wet location, use with B1 trims only. COLOR HOUSING ORDERING INFORMATION HOUSING ENGINE CODE WATTAGE CODE LRTA6 C2 BEVEL STYLE B1 1 Regress Bevel, Painted Die Cast Matches Flange Finish AB1 1 Regress Bevel, Black Anodized AC1 1 Regress Bevel, Clear Matte Anodized OPTIONAL LENS 2 FLANGE FINISH S Solite N No Glass (provided standard) F Frosted C Clear 2 2 Clear lens provided standard with wet location C2NC1 27KS 2700K, 80+ CRI 10 10 beam 30KS 3000K, 80+ CRI 20 20 beam New Construction 1-1/8 Maximum 35KS 3500K, 80+ CRI Ceiling Thickness 40KS 4000K, 80+ CRI Please consult factory for other CCT s not shown here 2 Step MacAdam ellipse is standard for all * Note: For other beam spread options, see "Accessories" 01 Clear Matte (AC Bevel only) 02 Black Anodized (AB Bevel only) 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) 120V 277V 120V For use with 120V or 277V DIML2 0-10V dim, 10% (provided standard) DIML3 Lutron Hi-Lume 1% 2-wire, 120V only DIML4 Lutron Hi-Lume 1% 3-wire/ECO DIML6A Eldo 0-10V, 0.1%, logarithmic / Lutron controls DIML6B Eldo 0-10V 0.1%, linear controls DIML6E Eldo 0-10V, 1%, logarithmic/lutron controls DIML6F Eldo 0-10V, 1%, linear controls DIML7 Eldo DALI, 0.1% DIML8 Eldo DMX, 0.1% 3 For use with 120V only DIML3 Lutron A 2-wire, 1% 120V only 3 N/A with 80W Bevel Finish 1" Regress Flange Finish DIMMING REFLECTOR* HOUSING TYPE VOLTAGE OPTIONS ACCESSORIES NC1 1" Regress 4-7/8 Ø 6 Ø 7 Ø CB27 27" C-Channel Bars CB52 52" C-Channel Bars EML Emergency battery 4 EMLW Emergency battery, wet location 4 4 Above ceiling access required Optional Lens OPTICAL ACCESSORIES (Order separately) AL10J Refer to optical AL15J accessories AL20J matrix on next page for AL30J resulting AL40J beamspreads AS55J when accessory AL80J lens is combined with 10 and 20 AS61J optics BOFJ Borosilicate Frosted SOFJ Solite Frosted PRFJ Prismatic Prosted HEXJ Hex Cell Louver 1/8 Clearly specify quantity in your order 2014., LLC. Revised 07/20/2016

Beve 5.0 TRIM INFORMATION 1" Regress 4-7/8 Ø 6 Ø 7 Ø HOUSING INFORMATION New Construction Housing - NC1 5.0 MAX OUTPUT ADJUSTABLE 40 Optical Accessories Matrix if you want 6231 and you have. 10 20 15 beam AL10J N/A 20 beam AL15J N/A 25 beam AL30J AL15J 30 beam N/A AL20J 35 beam N/A AL30J 40 beam N/A AL40J 45 beam N/A AL55J 55 beam N/A AL80J 20x55 beam AS61J N/A 40x60 beam N/A AS61J size J size J 9-3/8 1-1/8 Maximum Ceiling Thickness 16-5/8 19-1/4 Shown w/ EM 8-3/8 20-1/8 SPECIFICATIONS TRIM: 6" round aperture with a 1" regressed bevel and 1/2" flange, retained by three mounting clips. Die cast aluminum bevel is self-flanged and is available in white, statuary bronze, black, and metalized grey finishes. Also available in black anodized or clear matte anodized bevel, with self finish or with contrasting painted flange. Custom color flanges available (provide RAL#). TRIM LENS: Trim is not shipped with an integral lens unless selected as an option. Solite or frosted lens available as an option. Wet location is provided with a clear lens. REFLECTOR: Interchangeable precision injection molded polycarbonate optic optimized for 10 or 20 beam distribution. ADJUSTMENT: True hot aiming with center beam optics is adjustable, with a completely tool-less mechanism. 0-40 lockable vertical tilt with 362 lockable rotation. FIELD REPLACEABLE LIGHT ENGINE: Available with a 40W, 60W or 80W (up to 6025 delivered lumens). Engine is field replaceable through the aperture without tools. COLOR: Beve is available in 4 color temperatures (2700K, 3000K, 3500K, 4000K). All color options are tightly binned for fixture-to-fixture color consistency within a 2-Step MacAdam Ellipse. 80+ color rendering index provided standard. RATED LIFE: Based on IESNA LM80-2008 50,000 hours at 70% lumen maintenance (L70). THERMAL MANAGEMENT: Proprietary high performance aluminum die cast heatsink for maximum life. Ambient temperatures at fixture location should not exceed 40 C during normal operation. FIELD REPLACEABLE : 0-10V, 100%-10% solid state electronic constant current DIML2 dimming driver with a high power factor is provided standard and sources current as follows: 40W: sources 2mA per fixture 60W: sources 4mA per fixture 80W: sources 4mA per fixture Specify 120V or 277V. Driver complies with IEEE C62.41 surge protection. DIMMING OPTIONS: Multiple dimming drivers available. See compatibility chart attached. Some on-time delay may be experienced depending on dimming driver and control system used. Note: DIML6A and DIML6E logarithmic control are intended for use with Lutron control systems; DIML6B and 6F linear control are intended for use with non- Lutron controls. DIML6 dimming driver sources 2mA for 40W and 60W units, and 4mA for 80W units. EMERGENCY: Emergency lighting battery pack with remote test switch requires above ceiling access, provides 190mA for 90 minutes. EMLW wet location option is available with B1 trim only and requires remote test switch and above ceiling access as well. MOUNTING: Butterfly brackets and adjustable nailer bars with integral nails provided. Nailer bars are extendible from 14" to 24" centers. HOUSING: Fabricated of 20 ga. galvanized steel with thru wire J-box, 4 in 4 out at min. 90 C, #12 AWG thru branch circuit wiring. MAXIMUM CEILING THICKNESS: As per drawings above. ACCESSORY HOLDER: Snap in accessory holder shipped with fixture. Accepts 2 accessories maximum, size J. CEILING CUT OUT: 6-3/8"Ø LISTINGS: Dry/Damp. Wet location option available with B1 trim only. NRTL/CSA-US tested to UL standards. IBEW union made. WARRANTY: 5 years Not for use in corrosive environment. Use of pressure washer voids warranty. Serviceable from above. For interior use only. PHOTOMETRICS: Consult factory or website for IES files. Tested in accordance with IESNA LM79-2008. 2014., LLC. Revised 07/20/2016

Beve 5.0 MAX OUTPUT ADJUSTABLE 40 6231 DELIVERED PERFORMANCE 6231 / 6331 40W 30KS 10 6231 / 6331 40W 30KS 20 2014., LLC. Revised 07/20/2016

Beve 5.0 MAX OUTPUT ADJUSTABLE 40 6231 DELIVERED PERFORMANCE 6231 / 6331 60W 30KS 10 6231 / 6331 60W 30KS 20 2014., LLC. Revised 07/20/2016

Beve 5.0 MAX OUTPUT ADJUSTABLE 40 6231 DELIVERED PERFORMANCE 6231 / 6331 80W 30KS 10 6231 / 6331 80W 30KS 20 2014., LLC. Revised 07/20/2016

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D2 / DIML2 Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D2 / DIML2 : 0-10V Dimming Driver Wiring (Dims down to 10%) D2 / DIML2 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V / 277V Use source current per Crestron ilux dimmer expansion module CLS-EXP-DIMFLV 100% - 10% fixture specification Crestron DIN Rail dimmer DIN-4DIMFLV4 100% - 10% sheet to determine Crestron DIN Rail analog output module DIN-A08 100% - 10% number of fixtures per Crestron 8 Channel dimmer module GLX-DIMFLV8 100% - 10% dimmer. Max number Crestron 8 Channel dimmer module GLXP-DIMFLV8 100% - 10% of fixtures is limited by Leviton IllumaTech dimmer IP710-DLX 100% - 10% dimmer load rating. Lightolier (Philips) Vega V2000FAMU 100% - 10% Lutron Diva DVTV-XX 100% - 10% * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIMMER: 0-10V D2 / DIML2 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. CLASS 2 CONTROL WIRES RELAY DIMMER: 0-10V w/ POWER SWITCHING D2 / DIML2 0-10V DIMMING (NO RELAY) 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- NOTE: If switched, non-dimming operation is desired, cap off purple and gray wires individually at installation. Do NOT cap purple and gray wires together. GROUND 2016., LLC. I2-264-2 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D3 / DIML3 Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D3 / DIML3 : Lutron Hi-Lume A-Series 2 Wire Fwd Phase (with neutral) / Dimming Driver Wiring (Dims down to 1%) 120V D3 / DIML3 Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Dimmer* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet ELV10 100% - 1% 1 26 1 13 ETC Unison DRd Cabinet ELV10 100% - 1% 1 26 1 13 Lutron Maestro Wireless 600W dimmer MRF2-6ND-120-100% - 1% 1 8 1 4 Lutron Maestro Wireless 1000W dimmer MRF2-10ND-120-100% - 1% 1 13 1 6 Lutron HomeWorks QS adaptive dimmer HQRD-6NA- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 600W dimmer HQRD-6ND- 100% - 1% 1 8 1 4 Lutron HomeWorks QS 1000 W dimmer HQRD-10ND- 100% - 1% 1 13 1 6 Lutron Caseta Wireless Pro 1000W dimmer PD-10NXD- 100% - 1% 1 13 1 6 Lutron Stanza dimmer SZ-6ND- 100% - 1% 1 8 1 4 Lutron RadioRA 2 adaptive dimmer RRD-6NA- 100% - 1% 1 8 1 4 Lutron RadioRA 2 1000 W dimmer RRD-10ND- 100% - 1% 1 6 1 3 Lutron myroom DIN power module MQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks QS wallbox power module HQRJ-WPM-6D-120-100% - 1% 1 26 1 13 Lutron Homeworks DIN power module LQSE-4A1-D 100% - 1% 1 6 1 3 Lutron HomeWorks wallbox power module HWI-WPM-6D-120 100% - 1% 1 26 1 13 Lutron GRAFIK Eye QS control unit QSGR-, QSGRJ- 100% - 1% 1 26 1 13 Lutron GRAFIK Eye 3000 control unit GRX-3100-, GRX-3500-100% - 1% 1 26 1 13 Lutron RPM-4U module HW-RPM-4U-120, LP-RPM-4U-120 100% - 1% 1 26 1 13 Lutron RPM-4A module HW-RPM-4A-120, LP-RPM-4A-120 100% - 1% 1 26 1 13 Lutron GP dimming panels Various 100% - 1% 1 26 1 13 Lutron Ariadni CL 250W dimmer AYCL-253P- 100%-1% 1 8 1 4 Lutron Diva CL 250W dimmer DVCL-253P-, DVSCCL-253P- 100%-1% 1 8 1 4 Lutron Grafik T CL or RF CL dimmer GT-250M-, GTJ-250M- 100%-1% 1 8 1 4 Lutron Nova T CL 250W dimmer NTCL-250-100%-1% 1 10 1 5 * NOTE: Refer to dimmer manufacturer's documentation for installation instructions and circuit details. D3 / DIML3 2 WIRE PHASE DIMMING DIMMER: 2 WIRE PHASE SWITCHED HOT V- GROUND ONLY FOR SWITCHES WITH 2016., LLC. I2-264-3 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D4 / DIML4 Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) D4 / DIML4 3-Wire Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V Only 39W and Less 40W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 1 53 1 26 Lutron Nova T NTF-10-100% 1% 1 41 1 20 Lutron Nova T NTF-103P- 100% 1% 1 20 1 10 Lutron Nova NF-10-100% 1% 1 41 1 20 Lutron Nova NF-103P- 100% 1% 1 20 1 10 Lutron Vareo VF-10-100% 1% 1 20 1 10 Lutron Skylark SF-10P-, SF-103P- 100% 1% 1 20 1 10 Lutron Diva DVF-103P-, DVSCF-103P- 100% 1% 1 20 1 10 Lutron Ariadni AYF-103P- 100% 1% 1 20 1 10 Lutron Vierti VTF-6A- 100% 1% 1 15 1 7 Lutron Maestro MAF-6AM-, MSCF-6AM- 100% 1% 1 15 1 7 Lutron Maestro Wireless MRF2-F6AN-DV- 100% 1% 1 15 1 7 Lutron RadioRA 2 RRD-F6AN-DV- 100% 1% 1 15 1 7 Lutron HomeWorks QS HQRD-F6AN-DV 100% 1% 1 15 1 7 Lutron Interfaces PHPM-3F-120, PHPM-3F-DV 100% 1% 1 41 1 20 Lutron GP Dimming Panels Various 100% 1% 1 41 1 20 277V Only 40W and Less 41W - 80W ETC Sensor+ Cabinet D20 Dimming module 100% - 1% 1 53 1 26 ETC Unison DRd Cabinet D20F Dimming module 100% - 1% 1 53 1 26 Lutron Nova T NTF-10-277- 100% 1% 1 44 1 22 Lutron Nova T NTF-103P-277-100% 1% 1 33 1 16 Lutron Nova NF-10-277- 100% 1% 1 44 1 22 Lutron Nova NF-103P-277-100% 1% 1 33 1 16 Lutron Skylark SF-12P-277-, SF-12P-277-3 100% 1% 1 33 1 16 Lutron Diva DVF-103P-277-, DVSCF-103P-277-100% 1% 1 33 1 16 Lutron Ariadni AYF-103P-277-100% 1% 1 44 1 22 Lutron Vierti VTF-6A- 100% 1% 1 33 1 16 Lutron Maestro MAF-6AM-277-, MSCF-6AM-277-100% 1% 1 20 1 10 Lutron Maestro Wireless MRF2-F6AN-DV- 100% 1% 1 33 1 16 Lutron RadioRA 2 RRD-F6AN-DV- 100% 1% 1 33 1 16 Lutron HomeWorks QS HQRD-F6AN-DV 100% 1% 1 33 1 16 Lutron Interfaces PHPM-3F-DV 100% 1% 1 88 1 44 Lutron GP Dimming Panels Various 100% 1% 1 88 1 44 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. DIML4 wiring diagrams continued on next page 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D4 / DIML4 Continued Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D4 / DIML4 : Lutron Hi-Lume A-Series Driver with 3-Wire FL Control / Dimming Driver Wiring (Dims down to 1%) GROUND DIMMER: 3 WIRE PHASE DIMMED HOT SWITCHED HOT D4 / DIML4 3 WIRE PHASE DIMMING CAP UNUSED ECOSYS WIRES PURPLE GRAY PURPLE ORANGE V- D4 / DIML4 : Lutron Hi-Lume A-Series Driver with EcoSystem Control / Dimming Driver Wiring (Dims down to D4 / DIML4 EcoSystem Dimmer Compatibility Chart Dimmed Light Qty Fixtures Per Control* Manufacturer Product Part Number Output Range Fixture Wattage 120V / 277V 39W and Less 40W - 80W Lutron PowPak dimming module RMJ-ECO32-DV-B 100% 1% 1 32 1 16 Lutron Energi Savr Node QSN-1ECO-S, QSN-2ECO-S 100% 1% 1 64 1 32 Lutron GRAFIK Eye QS (120V ONLY) QSGRJ-_E, QSGR-_E 100% 1% 1 64 1 32 Lutron Quantum Various 100% 1% 1 64 1 32 * NOTE: Number of fixtures may be higher if wattage is less than maximum values shown. Refer to dimmer manufacturer's documentation for installation instructions and circuit details. E2 E1 D4 / DIML4 EcoSystem CONTROLS ECOSYS BUS E2 E1 WALL CONTROL CAP UN-USED ORANGE WIRE PURPLE GRAY PURPLE ORANGE V- 2016., LLC. I2-264-4 Revised 03/22/2017

DIMMING COMPATIBILITY D6A / DIML6A and D6E / DIML6E D6B / DIML6B and D6F / DIML6F D6A / DIML6A and D6E / DIML6E Dimming Compatibility Table D6A / DIML6A and D6E / DIML6E are linearly programmed dimming drivers for use with logarithmic-style dimming controls (e.g., Lutron and others listed in the table below) D6A / DIML6A = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6E / DIML6E = Eldo ECOdrive 0-10V control dims from 100% to 1% D6A / DIML6A and D6E / DIML6E Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6A 6E Refer to manufacturer's Lutron Diva DVTV/NFTV with PP-20 99% - 0.1% 1% dimmer load rating for Lutron Nova T NTFTV with PP-20 99% - 0.1% 1% maximum and minimum Lutron Energi Savr Node QSN-4T16-S 100% - 0.1% 1% fixture quantities per Lutron GP Dimming Panels TVM2 Module 99% - 0.1% 1% dimmer. Lutron Interfaces GRX-TVI w/ GRX3503 100% - 0.1% 1% Enlighted compatible. Sensor Switch nio nio EZ 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% D6B / DIML6B and D6F / DIML6F Dimming Compatibility Table D6B / DIML6B and D6F / DIML6F are logarithmic-programmed dimming drivers for use with linear-style dimming controls (e.g., Crestron, non-lutron and others listed below) D6B / DIML6B = Eldo SOLOdrive 0-10V control dims from 100% to 0.1% D6F / DIML6F = Eldo ECOdrive 0-10V control dims from 100% to 1% D6B / DIML6B and D6F / DIML6F Dimmer Compatibility Chart Dimmed Light Qty Fixtures Manufacturer Product Part Number Output Range Per Dimmer* 120V & 277V DIML6B 6F Bush-Jaeger Electronic potentiometer 2112U-101 100% - 0.1% 1% Jung Electronic potentiometer 240-10 100% - 0.1% 1% Leviton Iluma Tech dimmer IP710-DLX 100% - 0.1% 1% Lightolier (Philips) Momentum (120V ONLY) ZP600FAM120 100% - 0.1% 1% Merten Electronic potentiometer 5729 100% - 0.1% 1% Pass & Seymour Titan CD4FB-W 100% - 0.1% 1% Watt Stopper Miro DCLV1 100% - 0.1% 1% Synergy Wallbox Dimmers ISD BC 100% - 0.1% 1% ABB i-bus SD/S 2.16.1 100% - 0.1% 1% Crestron Modules GLX-DIMFLV8, GLXP-DIMFLV8 100% - 0.1% 1% Crestron Green Light GLPAC-DIMFLV4-, GLPAC-DIMFLV8-100% - 0.1% 1% Crestron Green Light Power Pack GLPP-DIMFLVEX-PM, GLPP-1DIMFLV2EX-PM, GLPP-1DIMFLV3EX-PM 100% - 0.1% 1% Crestron DIN Rail Analog Output Module DIN-A08 100% - 0.1% 1% Crestron DIN Rail 0-10V Fluorescent Dimmer DIN-4DIMFLV4 100% - 0.1% 1% Crestron ilux 0-10V Dimmer Expansion Module CLS-EXP-DIMFLV 100% - 0.1% 1% enlighted Control Unit CU-3E-1R 100% - 0.1% 1% Refer to manufacturer's dimmer load rating for maximum and minimum fixture quantities per dimmer. Enlighted compatible. DIMMING WIRING SCHEMES: Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D6 / DIML6 D6 / DIML6 0-10V DIMMING W/RELAY TO SWITCH POWER 0-10V DIMMING (NO RELAY) CLASS 2 CONTROL WIRES DIMMER: 0-10V RELAY 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- GROUND DIMMER: 0-10V w/ POWER SWITCHING 0-10V (-) 0-10V (+) SWITCHED HOT GRAY PURPLE V- DIMMER: 0-10V w/ POWER SWITCHING DIML6A, 6B 0-10V DIMMING (NO RELAY) 2016., LLC. I2-264-6 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D7 / DIML7 and D7E Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D7 / DIML7 and D7E Dimming Driver Wiring D7 / DIML7 and D7E are linearly programmed dimming drivers. D7 / DIML7 = Eldo SOLOdrive DALI control dims from 100% to 0.1% D7E = Eldo ECOdrive DALI control dims from 100% to 1% D7 / DIML7 / D7E DALI CONTROLS DALI BUS DA DA WALL CONTROL ORANGE (-) ORANGE/ (+) V- 2016., LLC. I2-264-7 Revised 08/14/2017

DIMMING WIRING SCHEMES: DIMMING COMPATIBILITY D8 / DIML8 and D8E Wiring diagrams are examples of typical installations intended to illustrate the number of wires that must be run to fixture. These diagrams are not intended to specify all equipment necessary for a given dimming circuit. Refer to specific dimmer manufacturer's documentation for details. D8 / DIML8 and D8E Dimming Driver Wiring D8 / DIML8 and D8E are linearly programmed dimming drivers. D8 / DIML8 = Eldo POWERdrive DMX control dims from 100% to 0.1% D8E = Eldo POWERdrive DMX control dims from 100% to 1% DMX BUS - XLR CABLE OR SHIELDED DATA CABLE The data cable used must meet the following requirements: type: shielded, 2-conductor twisted pair maximum capacitance between conductors: 30 pf/ft maximum capacitance between conductor and shield: 55 pf/ft maximum resistance: 0.02 ohms/ft normal impedance: 100-140 ohms conductive core: 24 AWG is recommended If 3-wire data cables are preferred, we suggest a Belden 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Do not use standard microphone cables: they cannot transmit DMX512 data reliably over long distances. NOTE: DMX link termination device (by others) should be used on last fixture in line on a circuit to avoid signal loss. D8 / DIML8 / D8E DMX CONTROLS DMX BUS - XLR CABLE OR SHIELDED DATA CABLE SHIELD DMX (-) DMX (+) 5 PIN XLR JACKS STANDARD 8 BIT DMX 512 CONTROLLER RED BARE V- 2016., LLC. I2-264-8 Revised 08/14/2017