SAVE. Features. Excellent drying laundry function. Powerful dehumidifying capability. Quiet operation

Similar documents
DEHUMIDIFIER USER S MANUAL CFO-12E CFO-20E

SUKI. Dehumidifier WDH-928DB -20R. User s Manual

This dehumidifier is both compact and lightweight. The casters on the bottom of the unit make it easy to move from room to room.

PORTABLE DEHUMIDIFIER

DUE-1237 DEHUMIDIFIER Owner s Manual

12L Dehumidifier Model: HG00923

Models GDNM16A5BK4AA GDNM20A5BK4AA GDNM24A5BK4AA DEHUMIDIFIER OPERATING INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

USER MANUAL. Portable Air Conditioner and Heater With Heat Pump Technology PAC18. Please read this manual carefully prior to operating the product.

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW CLASSIC

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

20L/D DEHUMIDIFIER Model Number: IG9800

12L DEHUMIDIFIER OPERATING INSTRUCTIONS

8L DEHUMIDIFIER OPERATING INSTRUCTIONS

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

USERS MANUAL. Desiccant Dehumidifier. Model: ECO DD322FW SIMPLE. Read This Manual

MeacoDry ABC Range Dehumidifiers

PAC12H. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

PAC12J. 12,000btu Cool & Heat Portable Air Conditioner. Please read this manual carefully prior to operating the product.

ODE20: 20 LITRE DEHUIMIDIFIER

Operation Manual Portable Room Air Conditioner Models: RPC26WA / RPC35WA / RPC41WA

Dehumidifier Owner s Manual Read and save these instructions before use

DEHUMIDIFIER INSTRUCTION MANUAL. Table of Contents. English. Italiano. Svenska. Features Powerful Dehumidifying Drying inside Easy Dehumidifying

Dehumidifier. Instruction Manual. Model DH-320/A

DEHUMIDIFIER USER MANUAL 11 PINT FOR MODEL: 3PAD11 COMFORT...BUILT TO LAST

Portable Air Conditioner, Dehumidifier,Heater and Fan utilizing Heat Pump Technology

General Care and Safety Guide

DEHUMIDIFIER OWNER S MANUAL. Read this manual carefully before operating the appliance and retain it for future reference.

PORTABLE AIR CONDITIONER

USER MANUAL. Safety Precautions. Unit Specifications and Features. Operating Instructions. Installation Instructions.

GDDEM10 DEHUMIDIFIER

SH3020 USER INSTRUCTIONS

95-Pint Dehumidifier with Built-in Pump USER GUIDE IVALDH95PWWP

2.9kW Portable Air Conditioner

15,000 BTU Portable Air Conditioner

Fundamental safety warnings

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

USER INSTRUCTIONS FOR 0.25 LITRE MINI DEHUMIDIFIER - MODEL NO. DHMD025

2.9kW Portable Air Conditioner

Progress plus Instruction manual

PORTABLE AIR CONDITIONER

GMSG OWNER S MANUAL SPLIT-SYSTEM ROOM AIR CONDITIONER CONTENTS

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C120 TD-C160

30-pint Dehumidifier User Guide

AD-250. Dehumidifier OWNERS MANUAL. Read and save these instructions.

Mobile Air Conditioner Instruction Manual Model TC-N9KM

OPERATING INSTRUCTIONS

Meaco 10L small home dehumidifier Instructional Manual

Utopian Split A/C. Thank you for purchasing this quality Split A/C system!

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For model WA-7500M

OPERATING INSTRUCTIONS

DEHUMIDIFIER USER MANUAL 95 PINT FOR MODEL: 3PAD95. Quick Start Tips on Page 1 COMFORT...BUILT TO LAST

IMPORTANT SAFETY INSTRUCTIONS

Dehumidifier/Dryer. Model: EDV Please read the instruction manual before operating. Keep in a safe place for future reference

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Reverse Cycle Portable Air Conditioner with Dehumidifier

Portable Dehumidifier with Internal Pump

Inverter Split-type Room Air Conditioner

Trotec PAC FT 2600 Portable air conditioner

COMPACT PORTABLE AIR CONDITIONER USER MANUAL

20L Dehumidifier. Model Number: LDH V AC 50/60Hz 440W

DESICCANT DEHUMIDIFIER

USER MANUAL SILENT16 PORTABLE AIR CONDITIONER

COMPRESSOR DIGITAL DEHUMIDIFIER

COMPRESSOR TYPE DEHUMIDIFIER DÉSHUMIDIFICATEUR D AIR LUFTENTFEUCHTER LUCHTONTVOCHTIGER TD-C100

DEHUM3 INSTRUCTION MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Premium Low Energy Compressor Dehumidifier with Digital Humidistat CD16LE 16 litres per day USER MANUAL

Model No. GB-PAC-08E4. 8,000 BTU Portable Air Conditioner Operating Instructions

Operating Instructions

SPLIT - TYPE ROOM AIR CONDITIONER

Air always contains a certain amount of water in the form of vapour. This determines the

compact ceramic heater

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

Portable Dehumidifier

DEHUMIDIFIER MODELS: SD-30E / SD-40E / SD-65E INSTRUCTION MANUAL

20L Electronic Dehumidifier

Split Portable Air Conditioner

10L Dehumidifier. Model Number: LDH V AC 50/60Hz 290W

Dehumidifier. User Manual

3 In 1 AIR CONDITIONER with REMOTE CONTROL MODEL NO: CA9000 PART No: OPERATION & MAINTENANCE INSTRUCTIONS

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

5) Do not start or stop the unit by inserting or pulling out the power plug.

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

ARTICA. 8000Btu. Room Air Conditioners Portable Range

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

Model DAC12004RC. Please read this manual carefully before use and keep it for future reference.

ROOM AIR CONDITIONER. Read This Manual. Before using your air conditioner, please read this manual carefully and keep it for future reference.

12,000 BTU Evaporative Portable Air Conditioner

Air Conditioner PORTABLE. Instruction Manual. Your Guarantee. Portable Air Conditioner / Heater. For models WA-1010E, WA-1010H, WA-1010M

INSTRUCTIONS Français 2 Nederlands 15 English 28 Italien

USER MANUAL SILENT12 PORTABLE AIR CONDITIONER

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

User Manual. Chest Freezer ZFC26500WA

DEHUMIDIFIER MODELS: SD-31E / SD-41E / SD-61E / SD-71E INSTRUCTION MANUAL

Portable Air Conditioner

XC Portable Air Conditioning

AC-12200E Portable Air Conditioner

Operating Instructions Air Conditioner

Owner s Manual CMC100 Dehumidifier

Transcription:

Features Powerful dehumidifying capability The dehumidifier powerfully removes excess moisture from the air creating a drier,healthier home environment. Excellent drying laundry function The dehumidifier dries laundry quickly. This can prevent laundry and furniture from becoming damp and musty in a rainy season. Quiet operation For overnight operation,the QUIET mode may be selected. Drainage tank with a large capacity Large 6 litre capacity water tank means the dehumidifier requires emptying less often. Using refrigerant for protecting environment The dehumidifier uses no CFC refrigerant therefore protecting the environment. Modern Design The dehumidifier is compact with a streamlined appearance and modern design. The castors at the bottom allow easy mobility. Saving energy The power consumption is low. SAVE - 1 -

Specifications Model CF08M CF05M Power Supply 220 ~240V ~ 50Hz Dehumidifying Capacity Power Consumption 0.8L/h 360W 0.5L/h 200W Drainage Tank Capacity 6.0L Weight 14kg 12.5kg Dimension(height width depth) 380mm 545mm 261.5mm The dehumidification capacity is the value obtained after the dehumidifier was continuously run in the room temperature of 30 with the relative humidity 80%. The amount of dehumidification is the amount per day(24 hours). The manufacturer reserves the right to change specifications without prior notification. The work temperature is in the range 2 to 38. If the room temperature is beyond the range, the unit can not operate normally. How dehumidifying works If you pour cold water into a cup, the air around the cup is cooled, and drops of water form on the surface of the cup. The dehumidifier takes advantage of this phenomenon to remove moisture. Moist air Compressor Cooling unit Re-heating unit Dried air Drainage tank It draws in room air, cools it with a cooling unit, and changes the humidity to drops of water. The drops of water fall into a drainage tank. The dehumidified air is re-heated by a heating unit and discharged. Steps,,and are repeated to remove humidity from the room. After the air passes through the re-heating unit, its temperature will rise a little, so that the temperature of the room will rise by 2 to 4. This is normal operation. - 2 -

Description Front panel Handle Louvre Air Outlet Control Panel Refer to next page Sensor Do not obstruct! Guard Float Water Level Gauge Drainage Tank When the unit is purchased, there may be some water left in the drainage tank. This is from the dehumidifying test conducted at the factory, and does not indicate a problem. Back panel Air Filter (Back panel air inlet) do not obstruct! Refer to page 8 Cord Hook Continuous Drainage Port Refer to page 7 Cord Band (undo on operation) Power Supply Plug Castors Refer to page 7-3 -

Operation Operation panel Indicator lamp 1. (Tank full indicator lamp): It will light when the drainage tank is full or positioned incorrectly. Empty the water out of the drainage tank, and make sure the tank is positioned properly. 2. (Power indicator lamp): It will light when the unit is plugged in. 3.DEHUMIDIFY mode: Turn the control switch to. Operation is continuous,with the amount of discharged air at the middle level. 4.LAUNDRY mode: Turn the control switch to. Operation is continuous,with the amount of discharged air at the high level.this is appropriate for enhanced dehumidifying,drying clothes or other items. 5.QUIET mode: Turn the control switch to. Operation is continuous,with the amount of discharged air at the low level.this suppresses operation noise when dehumidifying ( Under the condition of high temperature and high humidity,please avoid operating the unit in QUIET mode,as this can decrease the life of the unit.) - 4 -

Operation 1.Plug the power supply plug into the outlet 230-240V AC Use single phase 220V ~ 240V AC power supply. Wipe dust off of the power supply plug and insert the plug firmly, all the way to the rubber section, if there is a dust on the plug, or the plug is not fully inserted in the outlet, electrical shock and/or fire may result. Never scratch, cut, or damage the power supply cord. Power indicator lamp lights to indicate that power is on. 2.Open the louver by hand Before operation please check and make sure the louver has been opened to ensure adequate air flow. Set louvre to desired angle (when room temperature is above 32 set louvre to vertical position to allow maximum air flow.) 3.Switch the operation mode DEHUMIDIFY mode: Turn the control switch to. Operation is continuous,with the amount of discharged air at the middle level. LAUNDRY mode: Turn the control switch to. Operation is continuous,with the amount of discharged air at the high level.this is appropriate for enhanced dehumidifying,drying clothes or other items. QUIET mode: Turn the control switch to. Operation is continuous,with the amount of discharged air at the low level.this suppresses operation noise when dehumidifying ( Under the condition of high temperature and high humidity,please avoid operating the unit in QUIET mode,as this can decrease the life of the unit.) 4.Stop operation Turn the control switch to Dehumidifying stops. Never stop the unit by unplugging the power supply cord. Be sure after 3~ 5 minutes to restart the unit again when the unit is stopped or power supply is cut. - 5 -

Operation Draining the water The drainage tank is full When the drainage tank becomes full (approx, 6 Litres), the full indicator lights to alert the user, and the unit turns off automatically. Empty the water from the tank and discard it. Drainage steps 1. Remove the drainage tank Lightly pressing on the sides of the tank with both hands, pull it gently out. Notation for drainage Do not remove the bubble packing from the float on the unit. The float on the unit will no longer be able to detect without the bubble packing when the water level is full, and water may leak from the tank. Take hold of the handle, and then remove the tank. If the drainage tank is dirty, wash it with cold or lukewarm water. Do not use detergent, scouring pads, chemically treated cloths, or other cleaning solutions as it may damage the drainage tank. Abstergent Thinner Gasoline 2. Discard the water Guard Drain water from this point When replacing the drainage tank, press the tank firmly into place with both hands. If the tank is not positioned properly, the Tank Full sensor will activate, and the dehumidifier will not operate. Check to make sure the guards are firmly attached to the tank. If they are not, the drainage tank will be harder to remove. 3. Place the drainage tank back in it s compartment. If the drainage tank is removed while the unit is in operation, or immediately after operation has stopped, water which is still in the cooling unit may drip out on the base plate. Wait at least 30 minutes before removing the drainage tank.(if water has dripped, wipe it up.) - 6 -

Operation Draining the water Continuous drainage of water The unit has an optional continuous drainage port. Water can be continually drained by connecting a rubber hose (15mm I.D), to this drainage port.when setting up the dehumidifier for continuous drainage, always turn the unit off and unplug the supply plug. 1. Disconnect the drainage tank and open the continuous drainage port. Use sidecutters or similar tool to cut away the continuous drainage port in the side of the main unit. 2. Push the hose into the continuous drainage port Pass a rubber hose (15mm I.D) through the continuous drainage port, and press it firmly into the drainage port in the main unit, making sure water does not leak. The height of drain piping should always be lower than the height of the drainage port. Make sure there are no kinks or obstructions in the rubber hose which may prevent the water draining out. 3.Return the drainage tank to its original position Check the hose periodically to make sure it is still connected and has not been obstructed. Moving the dehumidifier (using castors) 1.Drain the water. 2.Lift up the handle. 3.Move the unit. Ensure the dehumidifier has adequate clearance between the unit and nearby walls as shown below. At least 50 cm At least 20 cm At least 20 cm At least 20 cm Note: At least 20 cm 1.If the floor is made of a material that scratches easily, or if the floor is uneven, lift up the unit and move it. Also avoid rolling the unit on castors if the floor has shagpile carpet. 2.Tilt it within range of 20 to 30 degrees, as a rule (if you tip it too far, you may scratch the floor or water may leak.) 3.Be careful that the power supply cord doesn't get pinched under the unit. - 7 -

Maintenance Caring for the dehumidifier Cleaning the Unit Wipe it with a soft cloth Use a soft,clean cloth to wipe the surface. (Do not use volatile chemicals detergents,chemically treated cloths or other cleaning solutions.these could possibly damage the unit.) Cleaning the air filter The air filter should be cleaned approximately once every two weeks. weeks. 1.Remove the air filter Press downward on the tabs on the air filter to remove it. 2.Clean the air filter Run a vacuum cleaner lightly over the surface of the air filter to remove dirt. If the air filter is very dirty, wash it with warm water and a neutral cleaning solvent and dry it throughly. 3.Attach the air filter Insert the lower tabs of the air filter into the main unit and press the air filter until you hear the tabs click into place. - 8 -

Maintenance Storing the dehumidifier When the unit is not to be used for a long period of time 1. Fold up the power supply cord. 2. Discard any water left in the drainage tank and wipe away any remaining drops with a cloth. 3. Clean the air filter. 4. Store the unit Package the unit to keep it free of dust, and keep it upright and store in a cool, dry place. Important Safeguards Please note the following safety precautions when using the unit: 1.When the dehumidifier is used in the laundry,ensure there is adequate clearnce between the clothes and the unit as described on page 7,and prevent water dripping on the unit. 2.Before cleaning the unit or when it is not in use for a long period of time, unplug the power supply cord. 3.Do not use the dehumidifier in the immediate surroundings of a bath, shower, or swimming pool. 4.Do not place the unit close to a heater, or any appliance which will have a high temperature. 5.Do not place any objects into the Air Inlet or Outlet. 6.Do not sit or stand on the unit. 7.Discard water that has collected in the tank regularly. 8.Do not place the dehumidifier in an enclosed area i e closets, which will prevent air circulation. 9.Do not use the dehumidifier for any purpose other than for which it was originally intended. 10.Install the external drain piping on a downhill gradient to ensure that condensed water can be drained continuously. 11.If the supply cord is damaged, it must be replaced by the manufacture or its service agent or a similarly qualified person in order to avoid a hazard. 12.The appliance is not intended for use by young children and the infirm without supervision. 13.Young children should be supervised to ensure they do not play with the appliance. - 9 -

Maintenance Troubleshooting If a condition listed below occurs, please check the following items before seeking advice. Condition Cause What to do Has the power supply cord been disconnected? Plug the power supply cord into the outlet. Refer to page 5 The unit does not operate. Is the Full light blinking?(the tank is full or incorrectly positioned.) Is the temperature of the room above 38 or below 2. Discard the water in the drainage tank, and then reposition the tank. Refer to page 6. The protection device has activated. Please wait for the room temperature to be with in these limits. The dehumidifying function does not work Is the air filter clogged? Is the air inlet or outlet obstructed? Clean the air filter as instructed under Caring for the dehumidifier. Refer to page 8. Remove what ever is obstructing the air inlet or outlet. No air is discharged Is the air filter clogged? Is the louver open? Clean the air filter as instructed under Caring for the dehumidifier. Refer to page 8. Check to see if opened Operation is noisy. Is the unit sitting on an angle or unsteady? Is the air filter clogged? Move the unit to a more stable location. Clean the air filter as instructed under Caring for the dehumidifier. Refer to page 8. After following the steps above,and the fault persists,please contact De Longhi Ltd for service: Australia: 1800 126 659 New Zealand:0508 200 300-10 -

Maintenance Troubleshooting The following symptoms do not indicate a breakdown Symptom Reason Noise level increases during use. The sound level increases when the compressor turns on. The humidity does not drop. Is the room too big for the unit? Are windows or doors opened and closed frequently? Is there any item in the room which produces steam? Very little dehumidifying takes place, or none at all. This happens if the temperature and/or humidity of the room is low. When the unit is first used, the discharged air smells musty. Because the temperature of the heat exchanger rises abruptly, an unusual or musty odor may be produced for a moment. The unit echoes. If the unit is used in a room with wood flooring or in a small room, it may echo. When the unit is turned on,or a different mode is selected a strange noise is heard from the main unit. The refrigerant may make some noise until circulation stabilizes. Fluid or a white film is left in the drainage tank. This is water or steam residue left from dehumification testing at the factory.this does not indicate a problem. The unit will only run in Hi mode, regardlless of any other mode being selected. When the temperature of the room is above 35 the protection device is activated,which will only allow the unit to run in Hi mode.when the room temperature is below 15, the compressor operates at intervals of 40 minutes on and 10 minutes off, or the automatic defrost function had been initiated and the compressor will turn off temporarily. The fan is running and the compressor does not work. If the unit is started with in 3 minutes of the unit turning off, the protectection device is activated, which will initiate a 3 minutes delay on the compressor turning on,or the automatic defrost function has activated turning the compressor off temporarily. - 11 -

Contents Structure and principle Operation Maintenance Features Specifications How dehumidifying works Description Control panel Operation Draining the water Moving the dehumidifier Caring for the dehumidifier Storing the dehumidifier Important Safeguards Troubleshooting 1 2 2 3 4 5 6 7 8 9 9 10 Before using your dehumidifier, please read this user s manual carefully, in order to ensure correct and safe use. After reading the manual, make sure it is stored in a safe place for future reference if necessary.

66126662