Alfa Laval Arctigo ID

Similar documents
Alfa Laval Arctigo IS

Alfa Laval Optigo CC. Instruction manual. Product description Product labels Unpacking & lifting Installation Maintenance Spare parts

Spare parts. Alfa Laval Arctigo IS - Industrial air coolers

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

New Industrial Dual Flow Unit Coolers

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

Air cooler BC50 Blast freezer

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

Antarctic-Unit Cooler/Air Cooler

Blue. Efficient design, optimized performance. Alfa Laval Blue Enhanced design for outdoor duty

Air product news. Mid year Refrigeration

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

Goedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers

Güntner Info GHN. Vario Cubic for all refrigerants kw. Variable aircooler for industrial refrigerationw

Air cooler VNS Agricultural

This label warns for risk of electrical shock when failing to observe.

Transformer oil coolers BETA & CETA

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

INFO. Compact DUAL. GADC Air Cooler for HFC and CO 2. Dual discharge air cooler with and without integrated condensation water pump.

Küba SG commercial

1. Description INSTRUCTION FOR BLAST COOLER TYPE COOL 250. Material

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

1. Description INSTRUCTION FOR AIR BLAST COOLER TYPE COOL 450

Main technical datas:

Hi-Pres Cooling Products Catalogue. Product Catalogue

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

BLAST FREEZING ROOMS

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

INSTALLATION AND OPERATING INSTRUCTIONS GN2. HIGH EFFICIENCY CAST IRON BOILER FOR LIQUID and/or GAS FUELS

TEC Coolers. GEA Heat Exchangers. GEA Searle

Installation and maintenance instructions for cabin units type vertical IDAC (V50)

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Technical Data Ducted Three Phase Split System Air Conditioner

Evaporators 60HZ version

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

PR / MP I Laboratory / Medicine

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

VERSO Air Handling Units

Instruction Manual, Rotary Spray Heads

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

KR Electrical Defrost Unit Coolers (PN E108318_E)

QZHW Fan Coil Unit. Key features. Specifications

SERVICE MANUAL DISHWASHERS DIVA ACCESSIBILITY DISHWASHERS

TECHNICAL MANUAL YEFB HIGH PRESSURE DUCTED UNIT

Choose the winning team. Heat transfer technology for industrial cooling and air conditioning

VERSO Air Handling Units

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Roof top SPACE RPC 450Z R407C M011

LOW PROFILE EVAPORATORS

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

Remote Air Cooled Condensers C2 Series

Planning guide. Atec.

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

lindab we simplify construction Lindab Modular air handling units Transport and assembly manual

CRN A-F-G-E-HQQE 3x400D 50 HZ

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Evaporators and Coolers for COMMERCIAL USE. ALFACUBIC MODEL (DX, Brine and NH3) INSTRUCTIONS MANUAL IM EN

technical data Fan coil unit FWB small duct unit

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

For machines with - R290 refrigerant. From UK(S/N: ), EU onward. For machines with R404a refrigerant

HEATING & COOLING COIL PRODUCTS

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

Cleaning unit for coolant. :_decftez`_>r_fr] Book No.: V2

OPERATING INSTRUCTIONS

HANDBOOK REGULATOR VALVES. Ed REGULATOR VALVES RP-ED 01/ ENG 1

Installation and operating instructions. DK energy storage and DK energy buffer

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Roof top SPACE RPC 315Z R407C MA00

AIR COOLERS FOR WIDE RANGE OF APPLICATIONS

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

.2 Section Waste Management and Disposal.

Refrigerator BRFB1920SS BRFB1900FBI BRFB1920FBI

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AIR COOLERS CONDENSERS DRY COOLERS SPECIAL PRODUCTS

DEHUMIDIFIERS FOR SWIMMING POOL. International. ET INTERNATIONAL S.r.l. Via Circonvallazione Est, 32/R Castelfranco Veneto - TREVISO - ITALY

AIR COOLERS FOR MEAT PROCESSING

High Profile Evaporator

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

CABERO PRODUCT CATALOGUE

BMI / BRI VERTICAL AGITATOR

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

General information and installation instructions for Metal Detectors

LZT High efficiency air to water heat pumps with E.V.I. compressors

Installation Instruction Aircoolers

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

VERSAFLOW VORTEX Supplementary instructions

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

kw COOLING kw HEATING

DT/DTX Series Unit Coolers (R0 E316013)

Transcription:

Alfa Laval Arctigo ID Instruction manual Product description Product labels Unpacking & lifting Installation Maintenance Spare parts ORIGINAL INSTRUCTIONS

Index 1. Important information 1.1 Disclaimer...3 1.2 Intended use...3 1.3 Where to find product information...3 2. Product description Arctigo ID 2.1 General information & application...4 2.2 Standard configuration...4 2.3 Options...5 2.4 Code description...5 3. Product labels...6 4. Unpacking and lifting...8 5. Installation 5.1 Mounting dimensions...9 5.2 Mounting bracket...10 5.3 Technical spaces...10 5.4 Drain line...10 5.5 Electrical connections...11 6. Maintenance 6.1 Fan replacement...12 6.2 Driptray & drain...12 6.3 Side covers...12 6.4 Coil defrost heater element replacement...13 6.5 Driptray defrost heater element replacement...13 7. Spare parts...14 2

1 Important information 1.1 Disclaimer This Instruction Manual applies to all Alfa Laval Arctigo ID dual discharge industrial air cooler products and is supplied in combination with the Alfa Laval Air Cooler Product Manual AHE00042. Both manuals must be carefully examined and instructions should be followed up at all times. Alfa Laval does not accept liability for any damage resulting from non-compliance to the instructions as given in the manuals and order-related documents. 1.2 Intended use Air coolers are partly completed machinery according to Machine Directive 2006/42/EC and are intended for incorporation in cooling systems. Declarations of Incorporation are available on www. alfalaval.com. Air cooler units may not be put into operation until the conformity of the complete machine or cooling system has been declared according to the following standards and directives: Pressure Equipment Directive 2014/68/EU Machine Directive 2006/42/EC Low Voltage Directive 2014/35/EU Electrical Equipment of Machines IEC 60204-1 Electro Magnetic Compatibility 2014/30/EU Any applicable local or national legislation 1.3 Where to find product information Detailed technical data for individual product models are available in order related documents, on the product sticker and in product data sheets. Comprehensive technical information for all Alfa Laval air heat exchanger products is available on-line on www.alfalaval.com. This includes: Product manuals Instruction manuals Product leaflets & brochures Product data sheets (selection software) Dimensional drawings Electrical wiring diagrams Certificates Arctigo ID Alfa Laval offers world-wide service and support in over 55 countries. In case of any questions or uncertainty please contact your local Alfa Laval representative. Contact addresses are available at www.alfalaval.com. 3

2 Product description Arctigo ID 2.1 General information and application Arctigo ID is a wide and flexible range of dual discharge industrial air coolers for both cooling and freezing applications in medium to large cold rooms. This industrial air cooler line is designed to keep fresh and frozen goods refrigerated from +20 to -35 C, with either high or low humidity content. The Alfa Laval Arctigo range offers a wide variety of cooler configurations and a long list of options, always allowing to select the best model to suit all applications in industrial cooling installations. Dedicated Arctigo ID models can be configured for sensitive applications such as agricultural storage. Refrigerants: all H(C)FC, ammonia, brine, CO 2 Capacities (SC2): 3 up to 110 kw Air volume: 4,000 up to 50,000 m 3 /h. Refrigerant application HFC Ammonia CO 2 Brine Design pressure 33 bar 27 bar 33-40-50-60 bar 10 bar 2.2 Standard configuration Finned coil: - 3 coil block modules - 3, 4, 6 or 8 tube rows deep - Tubing ø 5/8 Cu ripple fin, smooth Cu tubing for brine or smooth stainless steel. - Tube pitch 50 mm square. - Corrugated Alu-fins - Fin spacings 4, 5, 6, 7, 8, 10 and 12 mm. 1 to 5 AC or EC fans, ø 450, 500 & 630 mm, blowing through the coil. 2-Speed AC/EC fan motors 400/50-60/3 or EC 230/50-60/1. Fan motors with dynamically and statically balanced external rotors, protection grade IP54 or IP55. Integrated thermo contacts (Clickson) provide reliable protection against thermal overload. Corrosion resistant materials: coil frame and casing pre-galvanized sheet steel, epoxy coated RAL 9002. Hinged side panels and driptray, drain(s) 1½" BSP external Fitted with schräder valve on the suction connection for testing purposes. Suitable for dry expansion or pumped system. Stickers indicate fan direction and refrigerant in/out. Each heat exchanger is leak tested with dry air and finally supplied with a dry air pre-charge. Delivery in mounting position. Coolers are mounted on wooden beams. Installation can take place with use of a forklift. 4

2.3 Options Defrost systems (incl. connection box for all electric defrost systems) - Electric defrost in driptray (E1) - Electric defrost - heavy (E2) - Electric defrost - light (E4)Hotgas defrost systems - Hotgas defrost, not connected - light (HG1), heavy (HG2) - Hotgas defrost, connected - light (HG1C), heavy (HG2C) - Hot glycol defrost - light (HW1), heavy (HW2) Fan ring heater connected (FRH) Hinged fan plate (HF) Driptray insulation 13 mm styropore + cladding (I2) Adapter 90 for horizontal driptray drain connection Export packing crate Coil protection - Pre-coated aluminium (EP) - AlMg2.5 sea water resistant aluminium fins (SWR) Slip-on flanges aluminium PN16 or stainless steel PN (F) Flanges for brine models only Stainless steel casing and frame (SSC) Reheating coil (RH) Two additional tube rows with separated fins and connection tubes. Only for 3, 4 and 6 tube rows models. Switch on/off (SW) Switch for each fan. Fan motors wired to connection box (CB) Central internal connection box wired to a single external switch (CB1) On special request only: - Draw-through fans for blast freezing applications. - Top mounted fans 2.4 Code description ID B 3 5-2 8 CU - E - 50 AL - 7.0-2H-5 - FA04A - D FRH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 Alfa Laval Arctigo industrial air cooler - dual discharge 2 Air direction (B=blow through, draw through execution (D) available on special request) 3 Cooler module size (1, 2, 3) 4 Number of fans (1 to 5) 5 Coil pitch (2=square) 6 Tube rows in air direction (3, 4, 6 or 8 rows) 7 Tube material (CU=copper, SS=stainless steel) 8 Refrigerant system (E=DX, W=brine, X=CO 2, PB=pumped bottom feed, PT=pumped top feed) 9 Maximum working pressure 10 Fin material (AL=aluminium, EP=precoated aluminium, SWR=sea water resistant aluminium) 11 Fin spacing (4, 5, 6, 7, 8, 10 and 12 mm) 12 Circuiting code (2H, 1H, 1/2H... 2D, 1D, 1/2D...) 13 Fan motor code 14 Fan connection 15 Option code 5

3 Product labels 9 2 3 4 8 6 7 1 10 5 5 1. Product label Manufacturer: Month / Year: Alfa Laval S.p.A. -Italy 03 / 2016 Model: ISD12-16CU-EH33-AL10.0-1/2H-4- GSE/E2 Item ID: 3289214612 Serial no. AA 2349091 O.A. 387589/20 Unit Net Weight: 171 Kg ±5% Sn EXAMPLE Model Refer to paragraph "2.4 Code description" Item ID Serial no. Communicate these when ordering spare parts as they identify the unit O. A. Order Acknowledgement number WARNING READ INSTRUCTION MANUAL BEFORE INSTALLATIONS OPERATIONS AND MAINTENANCE TO AVOID INJURIES OR DAMAGE Service enquiries www.alfalaval.com Unit Net Weight Check before any lifting operation to ensure that proper lifting tools are used 2. Product label - coil Manufacturer: Year: Alfa Laval S.p.A. -Italy 2016 Model: O.A. 387589/20 ISD12-16CU-EH33-AL10.0-1/2H-4- GSE/E2 Item ID: 3289214612 Serial no. AA 2349091 Sn Coil PED data: I Max DN: 35 Fluid Group 2 Coil Ts: +125/-60 C Ps: 33 bar Pt: 47 bar Test Date: 03-2016 EXAMPLE WARNING READ INSTRUCTION MANUAL BEFORE INSTALLATIONS OPERATIONS AND MAINTENANCE TO AVOID INJURIES OR DAMAGE Service enquiries www.alfalaval.com Model Refer to paragraph "2.4 Code description" Item ID Serial no. Max DN Fluid Group Coil Ts Ps Pt Test date Communicate these when ordering spare parts as they identify the unit Maximum diameter of the distributor tube According to PED Range of operating temperatures for the coil Design pressure Test pressure Date on which the coil has been pressure tested in the factory 6

5.307 ATTENZIONE! CIRCUITO FRIGORIFERO PRECARICATO CON AZOTO WARNING! PRECHARGED REFRIGERANT CIRCUIT WITH NITROGEN ACHTUNG! VERLADTER KÄLTEMITTELKREISLAUF MIT STICKSTOFF ATTENTION! CIRCUIT FRIGORIFIQUE PRE-CHARGE AVEC AZOTE BHИМАНИЕ! СИСТЕМА ЗАПРАВЛНА АЗОТОМ 3. Nitrogen precharge warning Heat exchanger coils are delivered from the manufacturer with an overpressure. Check pressure on the Schrader valve. Unpressurised units are to be reported immediately to manufacturer and noted as such on the bill of delivery. 4. Fan warning and fan type code 1st code position: airflow direction B= blow-through D= draw-through Type DL 2nd code position: rotation direction L= left R= right 5. Fan direction Sticker indicates fan rotation direction. 6. Electrical warning Switch off power supply before any maintenance or installation operation. 7. Grounding Mandatory grounding for all electrical components. Spare part item no 9460088799 8. Fan motor Fan motor item number IN OUT 9. In/Out Refrigerant connections inlet and outlet 10. Eurovent Sticker is applied when the product is included in the Eurvent Certify All program. 7

4 Unpacking and lifting Always follow guidelines and instructions as given in the air cooler product manual AHE00042. Arctigo ID air coolers are delivered in mounting position, mounted on wooden beams and a wooden pallet on top. Handling and positioning can take place with use of a forklift. When more than one cooler units are delivered in a single shipment, air coolers may be stacked during transportation. Arctigo ID air coolers are to be unloaded one by one and lifted according to the following procedure: Units must be unloaded and handled only from the long side, one at a time. In order to avoid damage to the driptrays or falling of the unit, ensure that the lifting forks cover both inner support beams on the lower pallet. Place the unit on the ground and loosen the fixing materials from the top pallet. Remove the top pallet. Lift the unit into mounting position and secure following instructions given in chapter "5 Installation". Once the unit is secured in the installation position, loosen the fixing materials from the lower support pallet and remove pallet. 8

5 Installation Always follow guidelines and instructions as given in the air cooler product manual AHE00042. 5.1 Mounting dimensions cooler model Dimensions (± 5 mm) L H M M1 M2 M3 M4 M5 ID 11 1438 432 1628 800 - - - - ID 12 2238 432 1628 1600 - - - - ID 13 3038 432 1628 2400 - - - - ID 14 3838 432 1628 1600 1600 - - - ID 15 4638 432 1628 1600 800 1600 - - ID 21 1638 532 1628 1000 - - - - ID 22 2638 532 1628 2000 - - - - ID 23 3638 532 1628 3000 - - - - ID 24 4638 532 1628 2000 2000 - - - ID 25 5638 532 1628 2000 1000 2000 - - ID 31 1838 532 1875 1200 - - - - ID 32 3038 532 1875 1200 1200 - - - ID 33 4238 532 1875 1200 1200 1200 - - ID 34 5438 532 1875 1200 1200 1200 1200 - ID 35 6638 532 1875 1200 1200 1200 1200 1200 M M1 (M2, M3 etc.) H drains 1½ L Detailed drawings showing all required mounting and refrigerant connection dimensions are available for download on www.alfalaval.com. Dimensional drawings 9

5.2 Mounting bracket M10 stud (minimum) Extra wide washer ISO-7093 Lock nut 18 Use extra wide washer (ISO 7093) when mounting the unit to the ceiling. Avoid any lateral torque on the mounting brackets. 24 5.3 Technical spaces Respect the required minimum space for defrost heater replacement D D L L 5.4 Drip tray drain The drain line diameter must be at least the size of the drip tray drain diameter and should be laid with an adequate slope. For room temperatures below 0 C drain line insulation and an internal or external heating element are required to prevent freezing. A syphon must be installed on the drain line, outside the cold room Tighten drain connection by hand only. 10

5.5 Electrical connections The following data determine which connection diagram is to be selected and respected for electrical installation: Cooler model indication Fan motor type Electrical options Detailed Electrical connection diagrams are available for download on www.alfalaval.com. When in doubt always contact your local supplier or Alfa Laval representative for assistance. Electrical connections 11

6 Maintenance Always follow guidelines and instructions as given in the air cooler product manual AHE00042. Always disconnect power supply before any maintenance activities take place. 6.1 Fan replacement Always disconnect power supply before performing any maintenance activities on fans and fan motors. Unscrew fixing bolts and remove old fan. Mount new fan in identical position. Use an anti corrosion compound when remounting the fixing bolts. Restore electric connection when the new fan has been mounted. 6.2 Driptray Driptrays can be opened for inspection, cleaning and maintenance purposes. Always disconnect drain line before opening the driptray. Prior to opening, run a full defrost cycle to remove any ice in the driptray. Ensure the driptray is empty before opening. The weight of any leftover water could injure the service operator if the driptray fell open accidentally. To open tray, first loosen and remove fixing bolts and then lower the drip tray. Respect the maximum opening angle to avoid damage to the driptray hinges. 6.3 Side covers All side covers are hinged and can be opened for inspection, cleaning and maintenance purposes. To open side covers, loosen fixing bolts. 12

6.4 Coil defrost element replacement Always disconnect power supply before handling defrost heater elements. Attention: heater elements can be hot! To remove a pair of coil heater elements, open side covers on both sides. Disconnect heater element, remove fixing screws and extract elements from coil. Mount new elements in reverse order, close side covers and restore electrical connections. 6.5 Driptray defrost element replacement Always disconnect power supply before handling defrost heater elements. Attention: heater elements can be hot! To remove driptray heater elements, open driptray. Driptray defrost heaters Disconnect heater element. Bend slightly to take the fixing clips out of their slots and gently slide the heater element from under the clamps that hold it to the bottom plate. Mount new element in reverse order, close driptray and restore electrical connections. Fixing clips 13

7 Spare parts 2 7 6 5 4 3 1 8 Spare parts for Alfa Laval Arctigo ID 1 Driptray (2 x identical) 2 Side panels (5 x identical) 3 Fan unit complete 4 Fan ring heater 5 Switch on/off 6 Electrical defrost element (identical for coil and driptray) 7 Connection box 8 Stainless steel adapter 90 for horizontal driptray drain connection Spare parts can be selected and ordered in the online ebusiness tool Alfa Laval Anytime. If required please contact your local Alfa Laval representative for assistance. Alfa Laval Anytime 14

15