Installation & Maintenance Instructions

Similar documents
Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

K Series (Model A) Fan Forced Wall Heaters

Installation & Maintenance Instructions

SERIES 500. Installation & Maintenance Instructions. Ceiling Mounted Fan Forced Heater WARNING SAVE THESE INSTRUCTIONS. Recessed Mount.

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

FLCH4R Garage and Utility Electric Heater

Electric Space Heater

DH Series Portable Industrial Unit Blower Air Heaters

R Series B & T2 Model

SAVE THESE INSTRUCTIONS

CPL Series Pedestal Convection Heater

... a. Electric Baseboard Heaters IN THIS SECTION J b t S. SY-STEl\t1S, I~C_

Tab 8. Cove Heaters HARRIS AIR IN THIS SECTION S"YSTE1V1S, INC. HearinB &..-Air CondirioninB Insrallarion &..-Service

IMPORTANT SAFETY INFORMATION

INSTALLATION & OPERATING INSTRUCTIONS & PARTS MANUAL

HI Industrial Utility Heater HI Soleus Air International

OWNER S MANUAL PLEASE READ AND SAVE THESE INSTRUCTIONS WHOLE ROOM RADIATOR HEATER. Model: HO-0221 THERMOSTAT

Installation & Maintenance Instructions

40E ELECTRIC FAN HEATER

Indoor/Outdoor Electric Patio Heater Model No: HP Operating Instructions HP Soleus Air International

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

IMPORTANT INSTRUCTIONS

IMPORTANT SAFETY INFORMATION:

FAN-FORCED UTILITY HEATER

40E ELECTRIC FAN HEATER

IMPORTANT SAFETY INFORMATION:

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

HC Ceramic Tower Heater Operating Instructions HC Soleus Air International

BASEBOARD MICATHERMIC HEATER

Important: Read all instructions and warnings carefully before starting installation. INSTALLATION INSTRUCTIONS GENERAL

ELECTRIC STOVE HEATER Models: FS2213B

IMPORTANT SAFETY INFORMATION:

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

IMPORTANT SAFETY INFORMATION:

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

Instruction Leaflet. Heater with Adjustable Thermostat PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

User s Manual & Operating Instructions

OWNER S MANUAL FINLEY FIREPLACE. Product code: UPC code: Date of purchase: / /

ARWH Series Smart Series Architectural Wall Heater

IMPORTANT SAFETY INFORMATION:

IMPORTANT SAFETY INFORMATION:

ELECTRIC FLAT PANEL FIREPLACE HEATER

PRACTICAL USER S GUIDE FOR THE ELECTRIC STOVE

VERNON ELECTRIC FIREPLACE

E1.5 ELECTRIC FAN HEATER

VERNON ELECTRIC FIREPLACE

FES - Series Portable Electric Heaters. YES - Series Suspended Electric Heaters CONTENTS

Installation & Maintenance Instructions

SFH136-CN TRUSTED FOR OVER 100 YEARS. Sunbeam Heater. Instruction Leaflet PLEASE READ AND SAVE THESE IMPORTANT INSTRUCTIONS

ELECTRIC OIL FILLED RADIATOR RADIADORES ELÉCTRICOS DE ACEITE INSTRUCTIONS FOR USE SAVE THESE INSTRUCTIONS

Oil-filled Radiator NY23EC-11L User Manual

IMPORTANT SAFETY INFORMATION:

Electric Garage Heater

PRACTICAL USER S GUIDE FOR THE SUB-COMPACT STOVE MODEL NUMBER: CS1205

Concept S-2. Indoor Infrared Stove Heater. RedCore Stove Heater

With Remote Control. English

READ AND SAVE THESE INSTRUCTIONS

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

18E ELECTRIC FAN HEATER

OWNER S MANUAL CARTER FIREPLACE. Product code: UPC code: Date of purchase: / /

Quest Power Electric Heat EHS 62 Pro

Quest Power Electric Heat EHS 31 Pro

Quartz 2 in 1 Convection and Radiant Heater Model : HQ12-15M

IMPORTANT INSTRUCTIONS SAVE THESE INSTRUCTIONS INSTRUCTIONES IMPORTANTES CONSERVEZ LES PRESENTES INSTRUCTIONS

1500 Watt OIL FILLER RADIATOR INSTRUCTION MANUAL. pure indoor living MODEL BOF2001-CN

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

OPERATION MANUAL AND WARRANTY ELECTRONIC INFRARED ZONE HEATING SYSTEM

ELECTRIC FIREPLACE HEATER ASSEMBLY AND OPERATION MANUAL IMPORTANT SAFETY INSTRUCTIONS

BLT-999W-2 Item # 60757

ELECTRIC FIREPLACE OWNER S MANUAL

Installation and Maintenance Manual Please retain this manual for future reference.

PRACTICAL USER S GUIDE FOR THE contempra ef STOVE

Salamander Heater OWNER S MANUAL. Model:DR-PS KW 240V 60Hz 1P DR-PS KW 240V 60Hz 1P DR-PS KW 208V 60Hz 3P

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

Installation & Maintenance Instructions

Installation & Maintenance Instructions

36 IN. ELECTIC FIREPLACE FMI MODEL # LEF36 Mounting Base Feet and Wall Mounting Bracket Included

Owner s Manual Phoenix FireBird

ELECTRIC FIREPLACE HEATER OPERATION MANUAL

HR1-08R-21 Reflective Heater Operating Instructions. Model No. HR1-08R Soleus Air International

Dayton Electric Infrared Fireplace User Manual

USER S MANUAL BUCKET FAN SERIES BUCKET FAN WHISPER SERIES

ELECTRIC FIREPLACE HEATER MODEL EF-BLT09 OWNER S MANUAL

ADDISON Freestanding Electric Stove Models: ACSB

CERAMIC HEATER MODEL: HT-1003 READ AND SAVE THESE INSTRUCTIONS

MODEL: DFH-IQH-62-01, DFH-IQH-62-02, DFH-IQH-62-03, DFH-IQH-62-04, DFH-IQH-62-05,DFH-IQH-06

ELECTRIC FIREPLACE INSERT MODEL EF-BLT10 OWNER S MANUAL

PRACTICAL USER S GUIDE FOR THE DIMPLEX PURIFIRE ELECTRIC STOVE

OWNER S MANUAL. Wall Hanging Mode. Pedestal Mode ELECTRIC FLAT PANEL FIREPLACE HEATER. Model Number: EFW-XB60B WARNING CAUTION

MS-11 Flat Panel Reflective Heater Operating Instructions. Model No. MS Soleus Air International

1500W STOVE HEATER INSTRUCTION MANUAL. Item No: 050-HA-50090

Model: M630-44FDC CAUTION:

AH-600 Baseboard Heater

Owner s Manual Phoenix Aquadry TX 200

BIONAIRE HEATER. Instruction Leaflet. pure indoor living MODEL: BCH4130. Read instructions before operating. Retain for future reference.

Hardwired Electric Garage Heater

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

Quest PowerHeat HFC 100 Pro

Transcription:

Portable High Temperature Blower Attention: Do not operate this heater in explosive areas. Installation & Maintenance Instructions Dear Owner, Congratulations! Thank you for purchasing this new heater by Marley Engineered Products. You have made a wise investment selecting the highest quality product in the heating industry. Please carefully read the installation and maintenance instructions shown in this manual. You should enjoy years of efficient heating comfort with this product from Marley Engineered Products... the industry s leader in design, manufacturing, quality and service.... The Employees of Marley Engineered Products Specifications Table 1 Model Electrical Data (50 Hz) Dimensions (In) Volts kw Phase Amps BTU Height Width Depth SDH3043 480 30 3 37.2 102,360 38.5 26 44 SDH3093 600 30 3 30.0 102,360 38.5 26 44 SDH4843 480 48 3 58.9 163,776 38.5 30-1/4 44 SDH4893 600 48 3 47.3 163,776 38.5 30-1/4 44 SDH6043 480 60 3 73.3 204,720 38.5 30-1/4 44 SDH6093 600 60 3 58.9 204,720 38.5 30-1/4 44

WARNING - IMPORTANT SAFTY INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Read all instructions before using this heater. 2. This heater is hot when in use. To avoid burns, do not let bare skin touch hot surfaces. If provided, use handles when moving this heater. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes, and curtains at least 3 feet (0.9m) from the front of the heater and keep them away from the sides and rear. 3. Extreme caution is necessary when any heater is used by or near children or handicapped individuals and whenever the heater is left operating and unattended. 4. Always disconnect heater when not in use. 5. Do not operate any heater with a damaged cable or plug or after the heater malfunctions, has been dropped or damaged in any manner. Return heater to authorized service facility for examination, electrical or mechanical adjustments, or repair. 6. Do not use outdoors. 7. This heater is not intended for use in bathrooms, laundry areas and similar indoor locations. Never locate heater where it may fall into a bathtub or other water container. 8. Do not run cord under carpeting. Do not cover cord with throw rugs, runners or the like. Arrange cord away from traffic area and where it will not be tripped over. 9. To disconnect heater, turn thermostat off, then remove plug from outlet. 10. Connect to properly grounded outlets only.. Do not insert or allow foreign objects to enter any ventilation or exhaust opening as this may cause an electric shock, fire or damage the heater.. To prevent a possible fire, do not block air intakes or exhaust in any manner. Do not use on soft surfaces, like a bed, where opening may become blocked. 13. A heater has hot and arcing or sparking parts inside.do not use it in areas where gasoline, paint, flammable liquids are used or stored. 14. Use this heater only as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons. 15. This heater is not intended for use with an extension cord. 16. Do not use as a residential or household heater. 17. SAVE THESE INSTRUCTIONS. ELECTRIC SHOCK HAZARD. Disconnect all power before installing or servicing heater. Failure to do so could result in personal injury or property damage. must be effectively grounded in accordance with the National Electrical Code, NFPA 70. 1. Use heater only on the voltage and frequency specified on the nameplate. 2. All wiring should be done in accordance with local codes and the National Electrical Code by a qualified person. 3. Branch circuit wire for connection to heater must be at least 90 C wire. 4. The top access panel is secured by 4 screws that must be loosened to gain access. Table A WIRING Model Number Volts kw Phase Amps Min Wire Size SDH3043 480 30 3 37.2 6 Ga SDH3063 600 30 3 30.0 8 Ga SDH4843 480 48 3 58.9 4 Ga SDH4863 600 48 3 47.3 4 Ga SDH6043 480 60 3 73.3 2 Ga SDH6063 600 60 3 58.9 4 Ga 5. A ground terminal is provided near the power terminal board. The ground wire should be connected before other connections are made. 6. Refer to Table A for proper size SO grade of cable. 7. A proper strain relief must be used with SO grade cable. 8. s are factory pre-wired for 3-phase delta operation. Some units can be converted to single phase operation by changing the wiring. The appropriate wiring diagram is also located on the back of the wiring compartment cover. Cord Preparation for Portable s 1. Determine the gage and number of conductors from the tabulation below using amps and phase from the heater nameplate. It is not recommended that cord exceed 50 feet in length. s in the heat mode should not be operated in room temperatures above 130 F. Fan motor is not designed to operate in ambients below -10 F. The SDH is designed to be used with 20 diameter flexible duct. A feature of the heater is that the fan speed can be easily adjusted from 1500 to 2300rpm, (SDH heaters are shipped from the factory with the fan speed set at 1800 rpm). The maximum external static load for the blower is.38 H2O, regardless of the fan speed selected. The outlet temperature is controlled by a built-in thermostatic control; the maximum outlet temperature is a function of the kw rating and the amount of air (cfm) flowing through the heater. The addition of flexible duct will provide additional static load, resulting in a lower cfm, the lower air flow will reaise maximum outlet temperature until the static load reaches.38 H2O. Exceeding the maximum static load will result in the tripping of the overtemperature control. The performance range of the SDH units is as shown in table B. The motor and fan have variable pitch pulleys for changing the air SET-UP AND OPERATION 2 Table B T Max. T at Max. kw Fan CFM No Load Static Load Static Load 30 1800 2200 42 F.38 H2O 86 F 48 1800 2200 68 F.38 H2O 144 F 60 1800 2200 88 F.38 H2O 170 F flow and the T. Graphs 1, 2 and 3 provide the performance data for each size heater at the recommended minimum, medium and maximum fan speeds. The curves end at the point where the.38 H2O static load has been reached. The temperature rise is based on using Marley 20 diameter SDHFX20 flexible duct. The performance curves were determined by actual testing; therefore using flexible duct not supplied by Marley may vary the results. The introduction of bends in the ducting will add static load equivalent to adding 15 feet of duct length for each 90 bend and 25 feet of duct length for each 180 bend.

Temperature Rise F 100 75 50 25 Temperature Rise vs Duct Length 30 kw 1500 2200 1800 WIRING (cont d.) SDH heaters can be easily field if modified to vary the fan speed. There may be some circumstances where the use of short lengths of duct may not create sufficient pressure drop to achieve the desired temperature rise. This may also be the case of using the unit without a duct. This insufficient static pressure drop may result in high air flow, with the maximum temperature rise below the desired level, (even after the fan speed has been reduced to the minimum rpm). An accessory SDHAD, adjustable damper, is available and can be attached to the heater to produce a static load, ranging from.1 to.19 H2O which will act to reduce the amount of air flow. Temperature Rise F 0 0 25 50 75 100 5 150 175 Duct Length in Feet Temperature Rise vs Duct Length 48 kw 160 140 1500 0 100 1800 80 60 2200 40 20 0 0 25 50 75 100 5 150 175 Duct Length in Feet 200 180 160 140 0 100 80 60 40 20 Temperature Rise F Temperature Rise vs Duct Length 60 kw 1500 1800 2200 The Friction Loss Graph 4 provides the actual test data on the friction loss for the ADHAD damper attachment. The losses are stated as the equivalent length in feet of 20 duct. Equivalent Duct Length FT 90 80 70 60 50 40 30 20 10 Damper Full Open Friction Loss SDHAD Damper Damper Full Closed 0 1400 1600 1800 2000 2200 2400 Fan The SDH Dragon includes 2 thermostats. The thermostat on the air inlet end of the unit is for the minimum air temperature desired. The thermostat on the discharge end of the heater is for the maximum air temperature desired. The two thermostats are wired in series with the heating element contactor coil. The temperature range of both thermostats is 60-180 F. 0 0 25 50 75 100 5 150 175 Duct Length in Feet ACCESSORIES Front of Rear of Duct Adapter 1/4-20 Wing nut Provided with SDHAD Adjustable Damper Adjustable Damper and Duct Adaptor 3

FAN SPEED ADJUSTMENTS Changing the Pitch Diameter of the Sheaves: 1. Tools required: 5/32 allen wrench, 3/8 nut driver, 9/16 box wrench and a medium size phillips screwdriver. 2. Remove the lower belt cover by removing the (5) sheet metal screws. 3. Remove the rear grille by removing the (4) 1/4 bolts and nuts. 4. Remove the belt cover inside the blower by removing the (4) sheet metal screws. 5. Loosen the (4) bolts, (2) on each side. See Fig. 1. Figure 1 7. Loosen the set screw on the fan pulley or motor pulley. Fig. 3 shows the construction of the fan pulley, the motor pulley is the same construction. Figure 3 3/8 Bolts Fan belt tension adjusting bolts 8. Rotate the front half of the pulley clockwise until it bottoms, then rotate counter clockwise until the set screw aligns with the flat in the threaded half of the pulley. The pulley is now in position for adjustment. See Table 1 for the number of turns out. Tip: Leave allen wrench in set screw and use free hand to hold fan blade. 6. Loosen the (2) motor tension lock nuts and the fan belt tension adjusting bolts. See Fig.2 Figure 2 Lock Nuts 3/8 Bolts Fan belt tension adjusting bolts Table 1 Fan No. of turns from full closed Fan No. of turns from full closed Pulley Fan Pulley Pulley Fan Pulley 1500 3 1-1/2 1950 1-1/2 3 1600 2-1/2 1-1/2 2000 1-1/2 3-1/2 1650 2 1-1/2 2100 1-1/2 4 1725 1-1/2 1-1/2 2200 1-1/2 4-1/2 1800 1 1-1/2 2300 1 4-1/2 1850 1/2 1-1/2 9. Retighten set screw, use of thread locking compound is recommended. 10. Adjust fan belt tension, see Fig. 2. A 1/2 of belt deflection is recommended. Tighten lock nuts.. Tighten the 3/8 bolts, see Fig. 1. Rotate fan blade to make sure the fan belt does not rub. 13. Reinstall top belt cover, grille and lower belt cover. Tip: Installing the grille before installing the lower cover makes it easier to access the two lower grille bolts. 4

WIRING DIAGRAMS P4 P5 P6 T1 T2 T3 T6 T9 T4 T7 T5 T8 Inlet Thermostat Outlet Thermostat Cutout Toggle Switch Relay 4 1 Front of Attach all Wires on this Side of Contactor to Auxillary Terminals L1 Contactor 10 Terminal Box L2 L3 Blk Blk/Red or Grey Through 1" Conduit Blk Wht Transformer Control Enclosure SDH 30kW, 480V, 3PH P4 P5 P6 Through 1/2" Conduit T1 T2 T3 T6 T9 T4 T7 T5 T8 Green Pilot Light Amber Pilot Light Inlet Thermostat Outlet Thermostat Cutout Toggle Switch Relay Wht Transformer 30 Amp Fusing Contactor Blk 10 1 13 14 17 18 Front of L1 L2 L3 45 Amp Fusing Contactor 4 15 1 through 1/4" Conduit Control Enclosure One end attached to screw in terminal box and other end attached to screw on sub panel. Terminal Box SDH 48kW, 480V, 3PH Through 1/2" Conduit P4 P5 P6 T1 T2 T3 T6 T9 T4 T7 T5 T8 Green Pilot Light Amber Pilot Light Inlet Thermostat Outlet Thermostat Cutout Toggle Switch Relay L1 L2 L3 Wht Transformer 50 Amp Fusing Contactor 50 Amp Fusing Contactor Blk 4 1 20 24 1 15 1 23 Front of 2 13 17 10 14 18 22 Control Enclosure through 1/4" Conduit One end attached to screw in terminal box and other end attached to screw on sub panel. Terminal Box SDH 60kW, 480V, 3PH 5

PARTS LOCATION 19 19 Front of View Showing Element Placement and Routing of Thermostat Capillary and Mounting of Bulb Element Assembly 30kW Element Assembly 48kW Front of 19 38 (20-1/2) 37 Twist Wire View Showing Element Placement and Routing of Thermostat Capillary and Mounting of Bulb (30-1/4) Element Assembly 60kW Front View with Grille Removed (All Sizes) (44) 32 21 18 23 21 Back of Fan Pulley 77 79 20 80 81 (38-1/2) 78 Pulley Side View Detail Showing Pulley and Belt Installation 36 84 45 16 Side View shown with and Control Terminal Box Covers Removed All Sizes 6

MAINTENANCE ELECTRIC SHOCK HAZARD. Disconnect heater from power supply before servicing and/or inspecting the heater; failure to do so may result in electrical shock. Replace or repair damaged cords or plugs immediately. Check tightness of all electrical connections prior to energizing heater. Blow out or vacuum away any dirt or debris that may have accumulated around the control enclosure fan motor or heating elements. RENEWAL PARTS IDENTIFICATION Element () Element () (16) Contactor (20) Transformer (21) Fuse Block (80) Fuse (81) Term. Block (84) Model No. Volts kw Phase Part No. Part No. Part No. Part No. Part No. Part No. Part No. Part No. SDH3043 480 30 3 8-304793-0(3) 8-304793-013(3) 193-1843-232 072-304551-008 315-304252-001 N/A N/A N/A* SDH3093 600 30 3 8-304793-0(3) 8-304793-014(3) 193-1843-233 072-304551-008 315-304252-003 N/A N/A N/A* SDH4843 480 48 3 8-304793-0(3) 8-304793-013(6) 193-1843-232 072-304551-008(2) 315-304252-001 9-025643-001 8-026510-005(3) 303-047468-004 SDH4893 600 48 3 8-304793-0(3) 8-304793-014(6) 193-1843-233 072-304551-008(2) 315-304252-003 9-025643-001 8-026510-005(3) 303-047468-004 SDH6043 480 60 3 8-304793-0(6) 8-304793-013(6) 193-1843-232 072-304551-008(2) 315-304252-001 9-025643-001(2) 8-026510-006(6) 303-047468-004 SDH6093 600 60 3 8-304793-0(6) 8-304793-014(6) 193-1843-233 072-304551-008(2) 315-304252-003 9-025643-001(2) 8-026510-006(6) 303-047468-004 * Wired directly to contactor. All units contain two sets of elements. The ratings of the elements on the discharge end have a lower wattage than the elements on the inlet end of heater. The ends of the elements are color coded, the lower wattage are color coded yellow and the higher wattage are color coded blue. a. Lower wattage elements, discharge end, yellow coded b. Higher wattage elements, fan end, blue coded PARTS COMMON TO ALL UNITS Item Description Part No. 18 Temperature Control 300-019560-002 19 Hi-Limit Cut-out 300-049200-004 23 Toggle Switch 292-0463-001 32 Blower Assembly 021-304823-009 33 Inlet & Outlet Grille 134-304780-002(2) 36 Caster / Locking 375-2535-007 37 Handle - Right Side 139-304779-003 38 Handle - Left Side 139-304779-004 45 Semipneumatic Wheel 333-557518-004(2) 77 Pulley Var. Pitch 7/8 225-305091-004 78 Pulley Var. Pitch 5/8 225-305091-003 79 Pulley Belt 017-049702-009 86 Pilot Light - Green 213-2066-043 87 Pilot Light - Amber 213-2066-042 94 Thermostat Knob 169-017949-004 95 Thermostat Label 220-0192-010 7

LIMITED WARRANTY All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation. The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the products. How to order repair parts: In order to obtain any needed repair or replacement parts, warranty service or technical information, please contact the Marley Engineered Products Service Center toll-free by calling 1-800-642-HEAT. When ordering replacement parts, always give the information listed as follows: 1. The Part Number 2. The Model Number 3. The Part Description 4. Date of Manufacture ECR 36513 3/05 470 Beauty Spot Rd. East Bennettsville, SC 295 USA 5200-2691-000 161-3048-003