OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

Similar documents
OWNERS MANUAL MODEL CC500

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

Technical Datasheet. FHG-S Models 28, and 45. Benefits at a Glance: State Route 22 Salem, NY 12865

Econoburn Technical Datasheet

NY Thermal Inc. WF-200 Wood Fired Boiler

WF200 Wood Fired Boiler

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

SCOTTY WOOD FURNACE Model DB-102 OWNER S MANUAL IMPORTANT

TW2000 WOOD-FIRED BOILER OWNER S MANUAL IMPORTANT

Installation, Operation and Service Manual

Owner s Manual for. PennStoker

Installation, Operation and Service Manual

Multi-Heat. Multi-Heat Datasheet Version Tarm Biomass 4 Britton Lane Lyme, NH 03768

BC Series II OIL-FIRED CAST IRON BOILER INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR US AND CANADIAN SALES

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

Hitzer Energy Master II Stoker Furnace Model 710 Owner s Manual Installation and Operation

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

Mighty Venter Power Vent System

DOMESTIC WATER HEATER OIL FIRED

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

STARFIRE IV SERIES 4 WATER OIL FIRED CAST IRON BOILER

Columbia Boiler Company

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

CHIMNEY INSTALLATION. Technical Bulletin #1

Pellet Vent INSTALLATION INSTRUCTIONS

qüé=`üáãåéó An effective chimney is an important part of any successful wood-burning system.

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

HEATING WITH WOOD Wood Boiler Planning Guide. Boiler Planning Plumbing Layouts Thermal Storage Clearances Wiring.

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

A hydronic system controls comfort by delivering heated or cooled fluid to the conditioned space through pipes.

Installation, Operation and Service Manual

INTRODUCTION THIS MANUAL INCLUDES IMPORTANT SAFETY INFORMATION

DIVISION FINNED WATER-TUBE WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

SOLO PLUS. Installation and Operations Manual. Models 30, 40, and 60. Wood-fired central heating boiler

CMO32 CMO50 DOMESTIC WATER HEATER OIL-FIRED. Models: CMO32 CMO50

GAS FIRED BOILERS FOR FORCED HOT WATER VENTING ADDENDUM. ECR International Ltd. - Olsen Division P.O. Box 900 Wallaceburg, Ont.

User s Information Manual

SUPER JACK/ BIG JACK OWNER S MANUAL. Model No. s BJ90 - SJ125. Assembly Installation Operation Repair Parts SUPER JACK SJ125 BIG JACK BJ90

HEATING WITH WOOD Wood Boiler Planning Guide. Boiler Planning Plumbing Layouts Thermal Storage Clearances Wiring.

DIVISION FINNED WATER-TUBE WATER HEATERS

tççç= ÜÉ~íáåÖ çéíáçåë

WATER-TUBE POOL HEATERS

INSTALLER'S GUIDE MASONRY CHIMNEY VENT KIT WARNING: BAYVENT800B 18- CH23D2-05

Bonus Plus. Installation and Operations Manual. Model 30. Wood-fired central heating boiler

CHAPTER 8 CHIMNEYS AND VENTS

Crown Boiler Company

SOLID FUEL WARM AIR FURNACE

WATER-TUBE POOL HEATERS

OWNER S MANUAL. DS Greenhouse Blast GH450. Do Not Discard This Manual. High Efficiency Wood or Coal Green House Furnace. Model:

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

FINNED WATER-TUBE POOL HEATERS

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

HOMEOWNER'S GUIDE FOR YOUR CONTEMPO FIREPLACE TABLE OF CONTENTS

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

CHAPTER 8 CHIMNEYS AND VENTS

INSTALLATION INSTRUCTIONS

SOLO PLUS. Installation and Operations Manual. Models 30, 40, and 60. Wood-fired central heating boiler

HVAC Equipment Access Equipment Location

INSTALLATION INSTRUCTIONS

Models TRB4075 TRB4095 TRB4110 TRB5100 TRB5115 TRB5135 TRB6130 TRB6145 TRB6165 TRB7165 TRB7180 TRB7190

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.)

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

DIVISION FINNED WATER-TUBE BOILERS

ZG Shown READ ALL INSTRUCTIONS IN THIS MANUAL AND RETAIN FOR FUTURE REFERENCE WARNING

SCS SCS

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

ERGOMAX 7 INSTALLATION

Technical Data Manual Model Nos. and pricing: see Price List

CHIMNEYS AND VENTS CHAPTER 8

WARNING FIRE OR EXPLOSION HAZARD.

USER'S INFORMATION MANUAL

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60. Benefits at a Glance:

Installation Instructions

User s Information Manual Galaxy GG/GX Series, Sentry S/SX Series and Sentinel SE Series Gas Boilers with Continuous Burning Pilot

RS Chimney Fan for Solid Fuel Applications

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

Technical Datasheet. P4 Pellet Boiler Models 8/15, 20/25, 32/38, 48/60, 80/100. Benefits at a Glance:

COMBUSTION APPLIANCE SAFETY INSPECTION FOR VENTED APPLIANCES*

Boiler Manual Installation and Operation Instructions

MODEL VC120 SOLID FUEL FURNACE. For use as an add-on to electric, gas, or oil furnaces or an independent wood furnace when equipped with a blower.

SCOTTY SS WOOD FURNACE Model DB-202A OWNER S MANUAL IMPORTANT

Installation & Maintenance Instructions

Boiler Manual. Finned Copper Tube Gas Boilers (MB) & Water Heaters (MW) Installation and Operation Instructions. HeatNet Control Manual

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

P.O. Box , Dallas, TX USER'S INFORMATION MANUAL Single-Stage Warm Air Gas Furnaces

St. Croix Greenfield Installation Manual

RS Chimney Fan For Gas & Oil Applications. Installation & Operating Manual USA CAN

INSTALLATION OPERATION AND SERVICE MANUAL

Model 1200G. SOLID FUEL WARM AIR FURNACE Owners Manual

Commercial Water Heaters. Genesis. Water Heater Design Guide

High Efficiency 3-Pass Oil Fired Hot Water Boiler

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

DIVISION FINNED WATER-TUBE BOILERS

Transcription:

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: UL 391 CAN/CSA B366.1 Unit Serial # Purchased From Company Address Name of Installer Installer Telephone # Date Installed IMPORTANT This manual must be given to the homeowner. Please read the warranty and return the warranty card to initiate coverage. We Strongly Recommend The Use Of A Carbon Monoxide Detector When Using Any Product That Consumes Fossil Fuels. THIS BOILER IS TO BE INSTALLED AS AN ADD ON UNIT TO A PRIMARY HEATING BOILER ONLY. IT IS INTENDED TO BE INSTALLED ONLY WITHIN THE BUILDING THAT IT IS HEATING. It is the responsibility of the person or company installing this boiler to verify before the installation that the boiler certifications shown on this page meet or exceed all local, state and regulatory requirements for installation and use of this boiler. Failure to do so voids all claims and warranties. Mar. 2010 Aussi disponible en Francais.

KEEP THIS MANUAL FOR FUTURE REFERENCE. Follow all instructions carefully for installation, maintenance & operation of the DO110 & DO180 boilers. CAUTION DO NOT TAMPER WITH THE UNIT OR CONTROLS - CALL A QUALIFIED SERVICE TECHNICIAN. DO NOT LEAVE COMBUSTIBLE MATERIAL AROUND THE UNIT. DO NOT stack items on or around the unit - check required clearances on page 2. DO NOT start a fire in the boiler until all installation requirements are complete and the operating instructions are understood. DO NOT use automatic stoking or sawdust fueling with this unit. DO NOT BURN GARBAGE, PAPER (except to start fire), FLAMMABLE LIQUIDS, DRIFTWOOD, TREATED WOOD (CREOSOTE, PRESERVATIVES, PAINT, STAIN, ETC.) IN YOUR BOILER. DAMAGE WILL RESULT AND VOID YOUR WARRANTY. DO NOT allow anyone that is unfamiliar with the boiler, to attend it. DO NOT load wood above the smoke flap inside the door, over-firing may result. DO NOT adjust the draft regulator above -.05 W.C., if this setting is exceeded it could cause the fire to burn out of control. DO know the location of the emergency disconnect switch for the unit. DO contact a qualified service technician before remodeling, for annual service/maintenance, before extended periods of shutdown and before start-up. ~PRE INSTALLATION CONSIDERATIONS~ FUEL Burn only clean, untreated hardwood and softwood. For the best performance, we recommend using seasoned (below 25% moisture) hardwood. Store the wood in neat, well supported piles, at least 4 from the boiler loading door. BOILER In the firebox install ash or sand to within 1 ½" of the bottom door frame or burn softwood at first, which creates ash quickly. This will improve the air flow through the wood. The boiler must be installed by a qualified technician currently active in the heating trade. The installation should meet or exceed all local and national codes having jurisdiction, including C.S.A. B365, the Installation Code for Solid Fuel Burning Appliances & Equipment. The boiler has been thoroughly tested with modern baseboard radiation. UNDERFLOOR & CAST IRON RADIATORS Special consideration must be taken when connecting the boiler to under floor systems without oxygen barrier pipe or when hooked to cast iron radiators, to prevent thermal shock or excess temperature water from entering under floor heating loops. Please consult with your system designer. CHIMNEY SYSTEM The specification of the chimney to be used complies with the requirement that, other than solid-fuel/oil combinations and add-ons, wood burning appliances shall not be connected to a venting system serving an appliance vented by another type of fuel. Connect the furnace to an approved solid fuel factory-built chimney (CANADA-CAN/ULC S629 standard for 650 chimney, UNITED STATES-UL103 Chimneys for Residential Type and Building Heating Appliances, Factory Built) or a safe, clean, sound condition, masonry chimney equipped with an approved liner (CANADA-CAN/ULC-S635-M90 Standard for Lining Systems for existing masonry or Factory Built Chimneys and Vents, UNITED STATES-UL1777 Chimney Liners)(e.g., stainless steel, clay, etc.) The chimney must be capable of maintaining a negative updraft at all times and in all conditions. Carefully inspect the chimney for safety before making a connection. Locate the boiler as close to the chimney as possible. DO NOT pass the smoke pipe through the ceiling, wall or floor to reach the chimney. Installation of this equipment shall be in accordance with regulations of authorities having jurisdiction and (in Canada) CSA Standard B139 "Installation Code for Oil Burning Equipment" and CSA B365 Installation Code for Solid Fuel Burning Appliances and Equipment,(in United States) UL 391 Solid Fuel and Combination Fuel Central and Supplementary Furnaces. -2-

ELECTRICAL Ensure the boiler disconnect switch is installed within easy reach. Ensure wiring cables are protected from hot surfaces. DO NOT install wiring cables or controls where it is possible for water to drip on them. The electrical installation must conform to all local and national codes standards as their jurisdiction may apply. When connecting to an oil fired boiler, the wiring should conform to our drawing on page 6. PLUMBING A 10 gallon or larger expansion tank is required for this system. The circulator pump shall have a minimum capacity of 7.5 imperial GPM flow rate. A safety power failure loop or dump zone and piping shall conform to the enclosed drawing on page 4 and also to local and national codes having authority. EQUIPMENT (all controls may not be supplied for your system) The following is the minimum parts that are provided with the boiler: 1 - Triple Aquastat 1 - Single Aquastat 1 - Interlock Relay 2-24 Volt Transformers 1 - J Box & Cover 1 - Damper Motor & Chain 2 - Wells (for aquastats) 1-30 PSI Pressure Relief Valve 1 - Zone Valve (normally open) 1 - ½ N.P. Drain Valve 1 - Tridicator (pressure & temperature gauge) INSTALLATION INSTRUCTIONS CLEARANCES Observe the minimum clearances to combustible materials. Front --- 48 Smoke pipe 18 Rear ---- 24 Side 1 --------- 24 Above --- 48 Side 2 ---------- 6 The boiler may be placed on a combustible floor by using 9/32 noncombustible cover, extending 18 in front, 18" at the rear & 6 on each side. ELECTRICAL Wood Boiler Triple Aquastat Settings: Oil Boiler Aquastat Settings: High Setting 200 F High Setting 170 to 180 F. Low Setting 180 F Low Setting 150 to 160 F. Wood Boiler Single Aquastat Setting 170 F. When the wood boiler is not in use, and a coil in the oil boiler supplies the domestic hot water, change the oil boiler aquastat to High 200 and Low 180 (this is to ensure an adequate supply of domestic hot water). The electrical connections to the oil fired boiler should conform to our drawing on page 6. COMBUSTION AIR To achieve satisfactory combustion, an adequate supply of fresh air is required. In confined areas, a grilled opening shall be provided. The minimum total area of openings is 1 square foot per gallon of oil burnt per hour. With combination units this area should be doubled. Where fans are used in the fuel storage area, they should be installed so as not to create negative pressures in the room where the boiler(s) are installed.

Adjustments of damper motor and chain: Damper chain should be adjusted when the damper door is in the down position. In this position the chain should be adjusted so there is a small amount of slack. The amount of lift or opening of the damper door is adjusted by moving the two pinch nuts on the stove bolt thread closer or further away from the lift strap. After proper adjustment of the draft chain and damper door the thermostat and limit controls will keep the fire within safe limits. CAUTION: This setting should not be altered for increased firing for any reason. INSTALLATION INSTRUCTIONS (cont d) CHIMNEY SYSTEM The chimney inner size should be the equivalent to 7 round min. or 8" round max. The wood boiler pipe and the oil boiler pipe should enter the chimney separately. If more than one opening is in the chimney, install oil on top and wood on the bottom. A minimum of 4 of masonry (vertically) shall be left between each opening. The smoke pipe should be blue or black steel, 24 ga. or heavier. Use as few turns as possible between the boiler and the chimney, each 90 elbow adds 10' of restriction and a 45 elbow adds 5' of restriction. The draft regulator set at -.05 W.C. maximum. Install the regulator a minimum of 18 and a maximum of 24 from the boiler breech. Maintain a minimum of ½ rise per foot of pipe from the boiler to the chimney. DO NOT run the pipe downhill from the boiler to the chimney. Confirm that the installation clearances are met or exceeded. All pipe joints should fit relatively gas tight, as on low fires, carbon monoxide is formed. Secure all smoke pipe joints with three sheet metal screws. NORMAL OPERATION The oil burner will start if the system temperature is below the settings on the oil boiler aquastat. The damper motor will open the damper when the temperature of the wood boiler falls below 170 F. The thermostats operate the n.c. zone valves. When any n.c. zone valve is open or when the thermostat calls for heat, the circulator starts. Should the temperature reach the high limit (200 F), the damper motor will close the damper and the circulator starts (if the normally open zone valve end switch wires are connected). The oil burner will not run if the high limit is reached.

PLUMBING The piping shall conform to the enclosed drawing below and also to local and national codes having authority. The dump zone should be your existing largest zone (that has all piping above the boiler.-eg. Living room or master bedroom). With a home built on slab or heating with an under floor radiant system, a separate zone should be added above the boiler. This zone would be of adequate size to dissipate at least 10,000 btu/hr on the DO110 & 15,000 btu/hr on the DO180. The piping must be a minimum of 3/4" (18mm) diameter & able to withstand a minimum temperature of 225 F (107 C). This loop shall be such that it can only be made inoperative by a deliberate manual action. Please ensure that the pressure relief valve and the boiler drain valve are piped to a safe drain (water discharging from either could be extremely hot and dangerous). All piping will be such that excessive pressure will not be developed in any portion of the boiler or system. DO110 & DO180 WOOD-FIRED BOILERS PARALLEL PIPING

CARE OF THE BOILER WHEN NOT IN USE When the boiler is going to be out of service for an extended period of time, carefully and thoroughly clean the smoke pipe, chimney, firebox and any part which has been in contact with hot gases. This is extremely important as rusting and corrosion occur when the boiler is idle. REPLACING THE HOT WATER COIL The rear casing panel of your boiler must be removed to gain access to the hot water coil mounting plate. It is necessary to remove the smoke pipe before removing the rear panel. (ENSURE THAT NO FIRE IS PRESENT AND POWER DISCONNECTS ARE OFF BEFORE REMOVING SMOKE PIPE). The water must be drained from the boiler before removing coil mounting plate, ensure the water supply to the coil is off before removing. CLEANING AND SERVICING It is necessary to remove ash and occasionally brush the inner surfaces with a wire brush and check the smoke pipe for ash or creosote as necessary. Leave 2" of ash in the wood firebox when cleaning, to aid in combustion. IMPORTANT: Fire can be caused by improper storage of ashes containing dormant hot coals. Store ashes in a tightly covered metal container. DO NOT place other waste in this container. VERY IMPORTANT: Replace all damaged or worn gaskets before reassembling. Fire door gaskets and seals must be maintained in good condition for safe operation. SPECIAL PROCEDURES ELECTRICAL POWER FAILURE PLEASE NOTE: Consult with your installer at the time of installation, to verify how to operate your system without electricity. 1. Maintain ½ the normal fire load. 2. The damper door must be manually operated. DO NOT prop or tie open. 3. Be careful when firing the boiler at this point. In a no power situation, extreme care must be used until a safe firing rate is known for your system. Remember you are now on thermal circulation only. It may be necessary to manually open zone valves (if used). Each system is different. NOTE: If you have an underfloor radiant system, you likely cannot use the wood boiler without electricity. EXTREME WOOD FIRE (Due to improper operation) 1. Disconnect the damper chain to prevent the damper door from opening. 2. Block the over-fire draft slot in the door. 3. Increase all thermostats to maximum. 4. Excessive heat may cause safety relief valve to open. (Ensure it is piped to a safe drain.) 5. DO NOT shut power off. FLUE FIRE 1. Call the Fire Department. 2. Shut off the main power switch to the boiler. 3. Diminish the fire in the boiler by closing all combustion air openings. 4. DO NOT remove the flue pipes until the fire is completely out. 5. Prepare to evacuate the house. 6. Have the chimney inspected and repair the flue if necessary before using it again.

Yellow Orange

A division of W.R BENJAMIN PRODUCTS LIMITED P.O. Box 2079, Springhill, Nova Scotia Canada B0M 1X0 Phone: (902) 597-3796 Fax: (902) 597-3797 E-mail: info@benjaminheating.com Web site: www.benjaminheating.com