Water is supplied from the discharge of the Circulating Water System to a Distribution Basin, from which the Cooling Tower Pumps take a suction.

Similar documents
CHAPTER 5 CONDENSER AND EVAPORATIVE COOLING TOWER

Layout. Guidelines11. Chapter 11: Layout Introduction

Presenters. Brett Alexander. Mihir Kalyani. Troy Reineck

DISTRIBUTION SYSTEMS. Water Piping and Pumps

How Much Energy is Really Being Wasted?

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

Secondary Systems: Condensate/Feedwater Cycle

EqUIPMENT LAYOUT MANUAL

Cold Weather Operation Of Cooling Towers

Chapter 14, Problem 27.

Open Cooling Tower. Equipment Layout Guide

Equipment Layout Manual. For Cooling Towers, Evaporative Condensers & Closed Circuit Coolers

Davis Besse NPP Construction

Low Profile Layout Guidelines

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

Series V Layout Guidelines

Closed Circuit Cooling Towers

HYBRID ADIABATIC Cooling System

Alfa Laval Wet Surface Air Coolers (WSAC ) FAQs

Greenhouse Temperature Management

Water in the air experiment discussion - Where did the water on the outside of the cups come from? How do you know?

MH fluid cooler HYBRID DESIGN. HIGHER PERFORMANCE.

DRAFT ECODESIGN REGULATION FOR ENER LOT21 PRODUCTS

MH Fluid Cooler HYBRID DESIGN. HIGHER PERFORMANCE.

VAF FILTRATION SYSTEMS V-SERIES AUTOMATIC SCREEN FILTERS

Water Piping and Pumps

What is Cooling S.Sen

Lenntech. Tel Fax

S.A. Klein and G.F. Nellis Cambridge University Press, 2011

HVAC (Heating, Ventilating, and Air Conditioning)

INTRODUCTION TO GREEN INFRASTRUCTURE HOW WE CAN PROTECT OUR COMMUNITIES AND OUR WATERS Maywood Public Library Bergen County, New Jersey

CONTENTS. B. System Design and Performance Requirements

Figure 17-1 Residential air conditioner (Image courtesy of Bryant Heating & Cooling Systems)

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Solid and Liquid Pollutants

CONTROL NARRATIVE. Ammonia Tank Farm Aqueous Ammonia Truck Unloading, Storage Tanks, Forwarding, Vaporizer & Dilution Air Package

HOW IT RELATES TO PERFORMANCE IN REFRIGERATED COMPRESSED AIR DRYERS

UNIT 6 STEAM CONDENSERS

Energy Efficient Corn Drying. Kenneth Hellevang, Ph.D., P.E. Professor & Extension Engineer

Division III Process Gas Treatment Equipment

Chiller Plant Design. Julian R. de Bullet President debullet Consulting

Cooling Tower Designs

Lab 1b Cooling Tower Performance and Sensors for Thermal-Fluid Systems

TECHNICAL BULLETIN SELECTING A COMPRESSED AIR DRYER INTRODUCTION

Operation & Maintenance of Cooling Tower

1998 Expedition/Navigator Workshop Manual

Thermodynamics II Chapter 6 Mixtures & Psychrometry

TASKS REGARDING COMBUSTION AIR

ANALYSIS AND DESIGN OF COOLING TOWER

Nuclear Plant Efficiently Removes Calcium Carbonate From Condenser Tubes

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Energy-Efficiency Measures List

Grain Dryer Exhaust Air Recycling System

Reducing Energy Use in Grain Dryers

Incident Summary #II (#8165) (FINAL)

Brown Hills College of Engineering & Technology

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Energedry Eliminator. Operations Manual. Electric Heat Drying System. K & J Representatives, LLC Fax

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

SPRAY ADIABATIC SYSTEM HYBRID SPRAY SYSTEM (H.S.S.) - OPEN CIRCUIT. Compliant with VDI 2047 Part 2 +30% LOW. Under approval.

BECAUSE TEMPERATURE MATTERS: MAINTAINING COOLING TOWERS

R4 Ventures LLC White Paper. Introduction

Public Information Meeting on Aquatic Plant Management: Lakes Mendota, Monona, Wingra, Waubesa, and Kegonsa. October 2 and 9, :00-8:30 p.m.

June Copyright Climatec

MODULE 6 HUMIDIFICATION AND AIR CONDITIONING

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

RC3-LCD remote control

HVAC Design Cooling Towers

Sustainable Stormwater Management through Green Infrastructure. Jersey City Public School #5

QuadraFlow Cooling Tower

HISTORICAL ECOLOGY OF THE DELTA Emerging Concepts about a Spatially Complex and Temporally Dynamic System

/ Aquatower Fiberglass Cooling Tower /

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

A Primer for Air Dryer Selection

Chapter 11. Design of Other BOP

TEACHER BACKGROUND INFORMATION Water Cycle

CHAPTER 3 BASIC STEAM CYCLE

Case Study: Preventing Reactor Feed-water 1X Vibration by the Addition of Axial Clearance in the Rotating Assembly

CHP-turbine room. CHP can capture almost EXTRACTED STEAM 20 PSI HIGH-PRESSURE STEAM 1250 PSI HEAT EXCHANGER HOT WATER SUPPLY F

InterSeptor Centrifugal Separators Operating & Maintenance Manual

Tray ST5. Tray Type Deaerator Pressurized.005 cc/liter. industrialsteam.com

Application Bulletin AB170628: Maximizing flow center pump longevity for Geothermal Systems

Privately held company

Pine Flat Lake Master Plan Update FACT SHEET September 2014

Aspects of Fire Regulations and Standards in the Atrium

How about Savings in Time, Money, Energy and Longer Life?

2002 Dodge Caravan SE

DOUBLE AND SINGLE ENTRY DRUM SCREEN ADVANCED WATER SCREENING TECHNOLOGY

Automotive Air Conditioning systems

The Innsbrook Direct-Vent & Vent-Free Fireplace Insert Systems

PERFECT HEATING, COOLING, AND VENTILATION

PRE INSTALLATION PROCEDURES

Beneficial Use of Landfill Gas for Leachate Evaporation and Power Generation

Introduction to Industrial Mechanical Components Course# ME810

Have you downloaded the groovy show App? Search in the Apple App store or the Google Play Store for Everything Under the Sun

Rouge River Gateway Master Plan Update: 2011

GLOBAL PROPERTY INSPECTIONS TECHNICAL BULLETIN August 1, 2002

Please refer to the drawing and notes for each particular plan view. Site Plan S1-1 Site Drawing. Electrical E1-1 Main Electrical Drawing

NOVALYNX CORPORATION MODEL A & A SLING PSYCHROMETER INSTRUCTION MANUAL

Transcription:

Cooling Towers Functions Cooling Towers have one function: Remove heat from the water discharged from the condenser so that the water can be discharged to the river or recirculated and reused. Some power plants, usually located on lakes or rivers, use cooling towers as a method of cooling the circulating water (the third non-radioactive cycle) that has been heated in the condenser. During colder months and fish non-spawning periods, the discharge from the condenser may be directed to the river. Recirculation of the water back to the inlet to the condenser occurs during certain fish sensitive times of the year (e.g. spring, summer, fall) so that only a limited amount of water from the plant condenser may be discharged to the lake or river. It is important to note that the heat transferred in a condenser may heat the circulating water as much as 40 degrees Fahrenheit (F). In some cases, power plants may have restrictions that prevent discharging water to the river at more than 90 degrees F. In other cases, they may have limits of no more than 5 degrees F difference between intake and discharge (averaged over a 24 hour period). When Cooling Towers are used, plant efficiency usually drops. One reason is that the Cooling Tower pumps (and fans, if used) consume a lot of power. Major Components Cooling Tower(Supply) Basin Water is supplied from the discharge of the Circulating Water System to a Distribution Basin, from which the Cooling Tower Pumps take a suction. Cooling Tower Pumps These large pumps supply water at over 100,000 gallons per minute to one or more Cooling Towers. Each pump is usually over 15 feet deep. The motor assembly may be 8 to 10 feet high. The total electrical demand of all the Cooling Tower pumps may be as much as 5% of the electrical output of the station. Cooling Towers There are 2 types of towers - mechanical draft and natural draft

Mechanical Draft Towers Mechanical draft Cooling Towers have long piping runs that spray the water downward. Large fans pull air across the dropping water to remove the heat. As the water drops downward onto the "fill" or slats in the cooling tower, the drops break up into a finer spray. On colder days, tall plumes of condensation can be seen. On warmer days, only small condensation plumes will be seen. Courtesy NSP Natural Draft Towers

This photo shows a single natural draft cooling tower as used at a European plant. Natural draft towers are typically about 400 ft (120 m) high, depending on the differential pressure between the cold outside air and the hot humid air on the inside of the tower as the driving force. No fans are used. Whether the natural or mechanical draft towers are used depends on climatic and operating requirement conditions. Courtesy KKN - Liebstadt NPP Simplified Diagrams The diagrams below illustrate the arrangement of components within the system and the major flow paths. Forced - or Natural Draft Cooling Tower

The green flow paths show how the water is taken from a river (yellow) to an intake supply basin (green) that the Circ Water Pumps take a suction from. The water is then pumped to the Condenser where the water is heated. The water is then sent to an exit distribution basin where the water then can be returned to the river and/or pumped by the Cooling Tower Pumps to the Cooling Towers then the water returned to the intake supply basin where the water can be reused. Natural Draft Cooling Tower

The green flow paths show how the warm water leaves the plant proper, is pumped to the natural draft cooling tower and is distributed. The cooled water, including makeup from the lake to account for evaporation losses to the atmosphere, is returned to the condenser. Courtesy CP&L Copyright 1996-2008. The Virtual Nuclear Tourist. All rights reserved. Revised: November 3, 2008.