AQUASNAP JUNIOR 30RHV

Similar documents
30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30HXC Nominal cooling capacity kw

3 0 H X C A - H P 2

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

30RB /30RQ

30RB /30RQ

50VZ (40PZ/38VZ) Vertical Air-Cooled Split-System Cooling Units. Nominal cooling capacity kw

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

High COP. Water-Cooled Screw Chiller

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30RB A /30RQ

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

Modular Air Cooled Scroll Chillers

30HX GLOBAL CHILLER LIQUID CHILLER IN HARMONY WITH THE ENVIRONMENT

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

AQUASNAP 30RA / 30RH

Condensing Units CUS 15-60

30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

50YZ 40BZ/38BZ Nominal cooling capacity kw Nominal heating capacity kw

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

30RB /30RQ

Neosys Product catalogue

30RB/RQ 039S-160S Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

condenciat cl Condensing units Outdoor condensing unit Variable speed propeller fan Use Description for direct expansion applications

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

30RBM/30RBP AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE PRODUCT SELECTION DATA

30KAV Variable Speed Air-cooled Screw Chiller

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

LSA LSA A + Air cooled water chillers with axial fans VERSIONS ACCESSORIES

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

Air Cooled Scroll Chiller

Air cooled industrial chillers

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

Компрессорно-конденсаторные агрегаты. Chiller. AQH DCI 20 to 30. Air Cooled Water Inverter Heat Pump Engineering Data Manual. 20 to 30 kw.

Product Data. Features/Benefits. 50TJ S Side Discharge Single-Package Rooftop Units 50/60 Hz 15 to 30 Nominal Tons

HT V2 HT Split

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

LZT High efficiency air to water heat pumps with E.V.I. compressors

LDK LDK. Air to water chillers and heat pumps VERSIONS ACCESSORIES

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

30RBS /30RQS Air-Cooled Liquid Chillers, Reversible Air-to-Water Heat Pumps. product selection data

Galletti Water chillers and heat pumps catalogue

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Motor-driven condensing units MTE MTE R-410A

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

MPE 4-76 kw. Outdoor monobloc unit. Air chillers and heat pumps MPE PLUS. Efficiency under all operating conditions. 152 galletti.

ROOFTOP PACKAGED AIR CONDITIONERS

Transcription:

High-Efficiency Air-To-Water Heat Pumps Carrier is participating in the Eurovent Certification Programme. Products are as listed in the Eurovent Directory of Certified Products. AQUASNAP JUNIOR 3RHV 6-11 Fan coil application Nominal cooling capacity 4.4-8.5 kw Nominal heating capacity 6.-.2 kw Floor heating application Nominal cooling capacity 6.1-11.8 kw Nominal heating capacity 6.2-.9 kw These heat pumps have been designed for space heating and cooling and are suitable for both fan coil and floor heating applications. 3RHV heat pumps feature the latest technological innovations, incorporating scroll compressors and operating on the ozone-friendly refrigerant HFC-4A. An electronic, microprocessor-based auto-adaptive control system ensures intelligent control of the compressor start-up sequence, permitting operation at low system water volumes. Features Refrigerant R-4A is a blend of R-32 and R-125, ensures superior performances to those achieved with R-47C and offers an economical solution to environmental protection problems. It has no effect on the ozone layer. The components of these units are specifically designed for R-4A refrigerant, and all units have been submitted to the necessary laboratory tests to ensure perfect operation. The unit incorporates one or two two-speed axial fans with horizontal air discharge. The advanced design allows exceptionally low-noise operation. At part load conditions or at low outdoor temperatures the fan speed is automatically reduced by 5%, for even quieter operation. The control system also permits programming operation at reduced speed for a preset time period. 3RHV sizes 8 and 11 are equipped with a soft starter device to limit the starting current. The Pro-Dialog Junior operator interface integrated into the front panel permits easy user control of the main unit functions: start/stop, temperature selection, alarm code display. The compact dimensions and reduced weight of these units facilitate installation, even in very restricted spaces. The use of galvanised steel panels guarantees increased resistance to atmospheric conditions. These components have exceeded the stringent salt-spray corrosion resistance tests according to ASTM 117, with over 5 hours exposure to aggressive environments. The panels are removable for improved service and easier access to the internal components. The condenser coils are made of copper tubes, mechanically expanded into aluminium fins, with an increased heat exchange surface. The refrigerant-to-water heat exchangers are plate heat exchangers, ensuring optimum heat transfer at reduced dimensions. The plates are made of welded stainless steel. This heat exchanger type requires less refrigerant than traditional heat exchangers of the same capacity.

Scroll compressors run very quietly and vibration-free. They are known for their durability and reliability. The motors are fully cooled by suction gas and permit up to 12 starts per hour. These compressors are especially designed for operation with R-4A. Microprocessor-controlled automatic outdoor heat exchanger defrost cycles allow the unit to operate with high efficiency at low outdoor temperatures. PRO-DIALOG control system PRO-DIALOG is an advanced numeric control system that combines complex intelligence with great operating simplicity. PRO-DIALOG constantly monitors all machine parameters and safety devices, and precisely manages the operation of compressor and fans for optimum energy efficiency. It also controls the operation of the external water pump. A powerful control system The PID control algorithm with permanent compensation for the difference between entering and leaving water temperature anticipates load variations, and ensures intelligent leaving water temperature control. Dual set point: two different supply water temperature set points can be manually programmed or selected, according to the thermal load expected during the course of the day in the zones to be air conditioned. This always ensures maximum comfort at minimum energy consumption. PRO-DIALOG control is auto-adaptive for improved heat pump protection. Compressor cycling is automatically adapted to the characteristics of the application according to the inertia of the water loop and prevents dangerous compressor short cycling. Note: The hydronic module is not provided: the expansion tank, safety valve and water pump must be installed on site. Physical data 3RHV 6 8 11 Fan coil application Nominal cooling capacity* kw 4.4 6.1 8.4 Nominal heating capacity** kw 6. 8.5.2 Floor heating application Nominal cooling capacity*** kw 6.1 8.6 11.8 Nominal heating capacity**** kw 6.2 8.35.9 Operating weight kg 85 88 112 Refrigerant type R-4A R-4A R-4A Compressor One scroll compressor Refrigerant-to-water heat exchanger Net water volume l.85.94 1.22 Max. water-side operating pressure kpa 3 3 3 Hydraulic circuit Water pressure drop* kpa 17 Water inlet/outlet connections in 1 1 1 Fans Number of fans/diameter mm 1/37 1/37 2/37 No. of blades 4 4 4 Fan speed r/s 17.5. 17.5 Sound pressure level db(a) 41 44 44 Sound power level db(a) 69 72 72 * Based on: evaporator entering/leaving water temperature 12 C/7 C, condenser entering air temperature of 35 C. ** Based on: condenser entering/leaving water temperature 4 C/45 C, evaporator entering air temperature of 7 C db/6 C wb. *** Based on: evaporator entering/leaving water temperature 23 C/18 C, condenser entering air temperature of 35 C. **** Based on: condenser entering/leaving water temperature 3 C/35 C, evaporator entering air temperature of 7 C db/6 C wb. Sound pressure level is measured at m distance. Electrical data 3RHV 6 8 11-7 11-9 Power supply V-ph-Hz 23-1-5 23-1-5 23-1-5 4-3-5 Voltage range V 7-253 7-253 7-253 36-44 Fan coil application Power input, cooling* kw 2. 2.77 3.36 3.36 Power input, heating** kw 2.4 3.15 3.52 3.52 Floor heating application Power input, cooling*** kw 2.3 2.91 3.48 3.48 Power input, heating**** kw 1.77 2.49 3.3 3.3 Maximum power input kw 2.9 3.53 4.7 4. Locked rotor current A 58 82 97 48 Max. starting current A 58 57 72 48 Full load current kw 16 19 23 Fan motor (23-1-5) Current drawn A.82 1. 1.64 1.64 Compressor crankcase heater (23-1-5) Current drawn A.11.11.11.11 * Based on: evaporator entering/leaving water temperature 12 C/7 C, condenser entering air temperature of 35 C. ** Based on: condenser entering/leaving water temperature 4 C/45 C, evaporator entering air temperature of 7 C db/6 C wb. *** Based on: evaporator entering/leaving water temperature 23 C/18 C, condenser entering air temperature of 35 C. **** Based on: condenser entering/leaving water temperature 3 C/35 C, evaporator entering air temperature of 7 C db/6 C wb. Maximum unit power input at maximum operating conditions and worst power supply volt

Cooling capacities 3RHV Condenser entering air temperature, C LWT 25 3 35 4 45 CAP UNIT COOL CAP UNIT COOL CAP UNIT COOL CAP UNIT COOL CAP UNIT COOL C kw kw l/s kw kw l/s kw kw l/s kw kw l/s kw kw l/s 6 5 4.9 1.65.23 4.58 1.78.22 4.9 1.99. 3.71 2.12.18 3.28 2.33.16 8 7.67 2..37 6.77 2.37.32 5.65 2.74.27 4.67 3..22 3.63 3.37.17 11.1 2.28.48 9.5 2.75.43 7.78 3.34.37 6.7 3.79.32 5.55 4.4.27 6 6 5.5 1.66.24 4.73 1.79.23 4.25 2.. 3.86 2.13.18 3.44 2.34.16 8 7.89 2.12.38 6.99 2.39.33 5.87 2.76.28 4.89 3.2.23 3.85 3.39.18 11.32 2.28.49 9.36 2.76.45 8.9 3.35.39 7.1 3.81.33 5.86 4.41.28 6 7 5. 1.66.25 4.88 1.79.23 4.4 2..21 4.2 2.13.19 3.6 2.34.17 8 8.12 2.13.39 7.22 2.4.34 6. 2.77.29 5.12 3.3.24 4.8 3.4.19 11.63 2.29.51 9.67 2.77.46 8.4 3.36.4 7.32 3.82.35 6.17 4.43.29 6 8 5.35 1.66.26 5.3 1.79.24 4.55 2..22 4.18 2.13. 3.76 2.34.18 8 8.35 2.14.4 7.45 2.41.36 6.33 2.78.3 5.35 3.4.26 4.31 3.41.21 11.94 2.3.52 9.98 2.78.48 8.71 3.37.42 7.63 3.83.36 6.48 4.45.31 6 9 5.5 1.67.26 5.18 1.8.25 4.71 2.1.22 4.33 2.14.21 3.92 2.35.19 8 8.5 2.16.41 7.67 2.43.37 6.55 2.8.31 5.57 3.6.27 4.53 3.43.22 11 11.9 2.3.53.29 2.79.49 9.2 3.38.43 7.94 3.85.38 6.79 4.46.32 6 5.65 1.67.27 5.33 1.8.25 4.86 2.1.23 4.49 2.14.21 4.7 2.35.19 8 8.65 2.17.41 7.9 2.44.38 6.78 2.81.32 5.8 3.7.28 4.76 3.44.23 11 11.24 2.31.54.6 2.8.51 9.33 3.39.45 8.25 3.86.39 7. 4.48.34 6 18 6.85 1.69.33 6.55 1.82.31 6. 2.3.29 5.74 2.16.27 - - - 8.62 2.27.51 9.72 2.54.46 8.6 2.91.41 7.62 3.17.36 - - - 11 14.4 2.36.67 13.8 2.87.62 11.81 3.48.56.73 3.97.51 - - - Values for size 11 are for single and three-phase units Full load correction factors for Eurovent laboratory test: Net cooling capacity 1. Legend: Energy efficiency ratio 1. LWT Leaving water temperature Evaporator pressure drop 1. CAP kw Net cooling capacity UNIT kw Unit power input (compressors, fans, control circuit) Application data: COOL l/s Evaporator water flow rate Refrigerant: R-4A Evaporator temperature rise: 5 K Capacity based on standard EUROVENT conditions Evaporator fluid: chilled water Fouling factor:.44 m 2 K/W Heating capacities 3RHV Entering air temperature, C - -7 7 LWT CAP CAP UNIT COND CAP CAP UNIT COND CAP CAP UNIT COND CAP CAP UNIT COND CAP CAP UNIT COND integr. inst. integr. inst. integr. inst. integr. inst. integr. inst. C kw kw kw l/s kw kw kw l/s kw kw kw l/s kw kw kw l/s kw kw kw l/s 6 3 2.55 2.93 1.6.12 3.48 4.14 1.57.17 4.66 5.39 1.52.22 6.3 6.3 1.46.3 6.91 6.91 1.43.33 8 3.5 4.3 2..17 4.38 5.21 2.4.21 6.14 7. 2.11.29 8.5 8.5 2.16.41 9.38 9.38 2..45 11 4.67 5.37 2.53.22 5.83 6.93 2.58.28 8.14 9.42 2.69.39 11.25 11.25 2.79.54 12.41 12.41 2.83.59 6 35 2.54 2.92 1.69.12 3.4 4.5 1.7.16 4.55 5.28 1.73.22 6. 6. 1.77.3 6.8 6.8 1.78.32 8 3.42 3.93 2.6.16 4.29 5.11 2.14. 5.99 6.95 2.31.29 8.35 8.35 2.49.4 9.22 9.22 2.57.44 11 4.59 5.28 2.81.22 5.7 6.78 2.85.27 7.87 9.13 2.93.38.9.9 3.3.52 12.1 12.1 3.7.57 6 4 2.54 2.92 1.79.12 3.33 3.82 1.84.16 4.45 5.11 1.95.21 6. 6. 2.9.29 6.7 6.7 2.14.32 8 3.34 3.83 2.12.16 4. 4.83 2.25. 5.85 6.72 2.51.28 8. 8. 2.82.39 9.6 9.6 2.95.43 11 4.51 5.18 3.9.22 5.58 6.41 3.13.27 7.61 8.75 3.17.36.55.55 3.28.5 11.62 11.62 3.31.55 6 45 - - - - 3.25 3.67 1.97.16 4.34 4.9 2.16.21 6. 6. 2.4.29 6.59 6.59 2.49.31 8 - - - - 4.11 4.64 2.35. 5.7 6.44 2.71.27 8.5 8.5 3.15.38 8.9 8.9 3.32.43 11 - - - - 5.45 6.16 3.4.26 7.34 8.29 3.41.35.. 3.52.49 11.22 11.22 3.55.54 6 5 - - - - - - - - 4.24 4.67 2.38. 5.9 5.9 2.72.28 6.49 6.49 2.85.31 8 - - - - - - - - 5.56 6.12 2.91.27 7.9 7.9 3.48.38 8.74 8.74 3.7.42 11 - - - - - - - - 7.8 7.8 3.65.34 9.85 9.85 3.77.47.83.83 3.79.52 Values for size 11 are for single and three-phase units Full load correction factors for Eurovent laboratory test: Net heating capacity 1. Legend: Energy efficiency ratio 1. LWT Leaving water temperature Condenser pressure drop 1. CAP Integ. kw Integrated heating capacity CAP Inst. kw Instantaneous heating capacity Application data: Unit kw Unit power input, (compressors, fans, control circuit) Refrigerant: R-4A Cond l/s Condenser water flow rate Condenser temperature rise: 5 K Condenser fluid: hot water Capacity based on standard EUROVENT conditions Fouling factor:.44 m 2 K/W

Dimensions A Power connection 3RHV 6 8 11 A mm 8 8 8 B mm 83 83 1264 C mm 3 3 3 Power connection D mm 58 58 58 A E mm 146 146 146 F mm 33 33 33 G mm 97 97 97 B H mm 157 157 157 Weight kg 85 88 112 B H G H G E D E E D E C F C F 3RHV 6-8 3RHV 11 Operating limits Operating range - cooling Start-up leaving water temperature 35 C maximum Operating range - heating Start-up leaving water temperature 3 C minimum 55 18 5 Leaving water temperature, C 16 14 12 8 6 4 2 Leaving water temperature, C 45 4 35 3 25 15 5-15 - -5 5 15 25 3 35 4 45 5-15 -12-9 -6-3 3 6 9 12 15 18 21 24 Outdoor air temperature, C Outdoor air temperature, C Water connections Air purge Unit water outlet ø 1" gas female Unit water inlet ø 1" gas female Drain

Clearances A D B C E A E D F F 3RHV 6-11 A mm B mm 25 C mm 5 D mm E mm 67 F mm 4 System water flow rate/volume 3RHV 6 8 11 Nominal water flow rate l/s.29.38.51 Minimum system water volume l 22 27 32 Sound power levels (db) 3RHV 125 Hz 25 Hz 5 Hz Hz Hz 4 Hz 8 Hz db(a) 6 75 68 66 65 6 55 48 69 8 77 71 7 68 63 57 54 72 11 78 72 69 67 63 59 53 72

Water pressure drop 3RHV 6 3 12 C Water pressure drop kpa 25 15 3 C 5,1,15,2,25,3,35 Water flow rate l/s 3RHV 8 3 12 C Water pressure drop kpa 25 15 3 C 5,1,15,2,25,3,35,4,45,5,55 Water flow rate l/s 4 3RHV 11 Water pressure drop kpa 35 3 25 15 12 C 3 C 5,15,25,35,45,55,65,75 Water flow rate l/s

Order No. 13448-, 6.5. Supersedes order No.: New. Manufacturer reserves the right to change any product specifications without notice. Manufactured by: Carrier Villasanta, Italy. Printed on Totally Chlorine Free Paper. Printed in the Netherlands.