AUDAX Air-water heat pumps reversible with inverter single and three-phase

Similar documents
HEAT PUMPS AUDAX TOP ErP AND INTEGRATED SYSTEMS

Advance Split

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Blue Box Epsilon Echos +

SPECIFICATIONS - NIKE

CRIMSON & CRIMSON MAX

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

HEAT PUMPS MAGIS PRO ErP

VICTRIX Superior kw Export VICTRIX Superior kw X Export

AIR COOLED HEAT PUMP FOR OUTDOOR INSTALLATION FROM 4,2 TO 35,1 kw

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

HEAT PUMPS MAGIS COMBO

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Service Manual. Chiller unit MQH R 410A. Release Date Rev Review Date november

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

1 VICTRIX ZEUS Superior kw I features

SOLUTIONS DE TRAITEMENT HEATING SOLUTIONS. Comfort Module 5-20 kw. Choose the easy heating solution!

PHRIE / PHIE InvERTER monoblock air To water HEaT PumP medium TEmPERaTuRE

Geolo THE GROUND SOURCE HEAT PUMP PLUSES

LCP kw. Outdoor monobloc air-water unit. Total heat recovery multi-purpose units LCP PLUS

LZA High efficiency air to water heat pumps with HP compressor

NIKE Star 24 3 E. Instantaneous wall-hung with open chamber boilers. NIKE Star 24 3 E

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

ENERGY LIGHT USER S GUIDE ENERGY LIGHT USER S GUIDE

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Technical Manual. Multi Split Trio Quattro DCI REFRIGERANT R410A HEAT PUMP

AVIO kw Export 1 FEATURES. Wall-mounted with storage tank

REMOTE CONTROL FOR CHILLER MYCHILLER

History List. Version Date Update Information New EHS SPLIT TDB Released. (Modify the Spec Note)

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

LZT High efficiency air to water heat pumps with E.V.I. compressors

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

SyScroll 40 to 75 Air NEW

Galletti Water chillers and heat pumps catalogue

A Evaporator B Fan C Terminal box D Hermetically sealed, output regulated digital scroll compressor E Condenser

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

HT V2 HT Split

PAC BT LOW TEMPERATURE HEAT PUMP

RMA AIR-WATER CHILLERS AND HEAT PUMPS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

PAC BT LOW TEMPERATURE HEAT PUMP WITH DHW TANK INCLUDED

PRODUCT RANGE HEAT PUMPS 2012

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

BLUEWAY DC INVERTER AIR TO WATER HEAT PUMP

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

BWL air heat pumps BWS brine heat pumps

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQUAHEAT ADVANCE SPLIT

80HMA. Comfort Module Range for Monobloc Heat Pumps. Compact comfort module. DHW management possibility. Multi zone option control.

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Construction details: Structure and base in hot dip galvanised sheet steel with epoxy pain finish (RAL 9002)

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

MPI DC 8-29 kw. Outdoor monobloc unit with BLDC compressor. Air chillers and heat pumps MPI DC PLUS

MULTIPLO PF Multifunction chillers for indoor installation. Cooling Capacity: kw Heating Capacity: kw

Engineering Data Manual

AIR TO WATER HEAT PUMPS. Hot water and comfortable ambient temperature all year round

WZH Ground source heat pumps

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

AIR COOLED FREE-COOLING CHILLERS WITH SCROLL COMPRESSORS AND AXIAL FANS

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

AWR MTD2 XE. Versions

Next P kw COOLING 5 93 kw HEATING. technicalcatalogue. Heat pump air conditioners with upflow air delivery T_NXTP_0411_GB

SATK wall-mounted Heat Interface Unit (HIU) Instantaneous domestic hot water production

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

LZT High efficiency air to water heat pumps with E.V.I. compressors

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

Do you want a versatile solution

Technical description. Atec.

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

Conditioning your ambient, maximising your comfort.

80HMA. Comfort Module Range for Monobloc Heat Pumps. Nominal heating capacity 4-20 kw Nominal cooling capacity 4-20 kw. Features

Control Application. Supplement - ACVMax

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 365 kw. Scroll Compressors SCAEY-FC DE 98

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Air Cooled Chillers & Heat Pumps WinPACK HE-A

LEP kw. Indoor monobloc water-water unit. Total heat recovery multi-purpose units LEP PLUS

AGEO CALEO. Water-to-water high temperature heat pumps USE RANGE DESCRIPTION. Designed to replace a conventional boiler and produce domestic hot water

GUIDE SPECIFICATIONS AQUARIUS ii

ACCUMULATION OF EUROPEAN CLASS

HYDRONIC RESIDENTIAL

Heat Pump Technology. Air Source, Water Source and Ground Source. Optimised heat pumps for residential and commercial applications

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

Transcription:

Air-water heat pumps reversible with inverter single and three-phase

16/18 AUDAX kw Three-phase reversible air/water Heat Pumps with inverter technology are the Immergas products for air conditioning, named "AUDAX 16 kw" and "AUDAX 18 kw". Designed especially for the production and distribution of heat and cold. They can function independently or coupled with other generators/systems. These machines can also be coupled to a remote storage tank unit for the production of DHW. Using the relevant system manager kit, it is always possible to make use of the most convenient energy source, alternating heat pump functioning of the boiler and also the solar heat system. The inverter technology and the features of these machines allow to attain high performance thus consenting to benefits from tax relief in compliance of the provisions of the M.D. 19/02/2007 and s.m.s. 1 AUDAX 16 and 18 kw are ideal for air conditioning large homes, offices, shops and pre-existing or new buildings. They have system side plate heat exchanger + circulation pump as per standard. A range of hydraulic, electrical and electronic kits are available, which allow flexible use in all circumstances. 3 AUDAX 16-18 kw FEATURES 16 kw and 18 kw three-phase inverter air/water heat pumps for winter and summer air conditioning. The galvanised steel structure makes the machines particularly suitable for outdoor installation. Components: - Inverter "scroll" rotational compressor; - R410A refrigerant gas; - External unit air/gas heat exchanger treated with Blue fin system: it makes it easier for the dew drops to slide off and reduces corrosion (for example when there is salt water); - Fan with variable speed managed by the electronic control board; - Steel plate water/gas eat exchanger with anti-freeze electric resistance (70 W) supplied as per standard; - Bi-flow electronic throttle valve; - 4-way inversion valve (reversible functioning with Heat Pump cycle or Cooling cycle); - IPX4 electrical insulation rating; - Possibility of outdoor installation in open places; - System 3 speed pump; - 5 litre expansion vessel; - 3 bar safety valve; - System manometer; - 7 probes: 4 sensors on the cooling circuit + external probe + inlet and outlet water temperature detection via 2 probes; - Regulation of the functioning parameters using keys with display of functioning status by means of a 3-digit display; - Self diagnostics with error codes shown on display; - Proportional control logic (linked to instant t) and integral logic control (linked to temperature variation time). System solutions: - "Stand alone" system with AUDAX and integrative resistance; - Can be coupled to separate storage tank for DHW; - Can be coupled to the solar heat system; - Can be coupled to boiler via the System Manager; - Can be coupled to boiler and the solar heat system via the System Manager. is available in the model: AUDAX 16 kw code 3.022095 AUDAX 18 kw code 3.022096 EC Declaration Of Conformity. NOTA BENE: 1 the M.D. 6 August 2009 establishes - for 55% tax relief - what the energy performance of an 35 kw air/water heat must be: COP 4.1 EER 3.8; if supplied with speed changer (inverter) these values decrease by 5%. For correct functioning of the AUDAX, free spaces must be left on top of and on all four sides of the machine itself, as indicated in the installation book accompanying the product. The instructions for correct installation must also be followed. 4

4 INTELLIGENT INTEGRATED SYSTEMS; NEW CONCEPT, HYBRID SYSTEMS FOR AIR CONDITIONING AND DHW PRODUCTION 4.1 INTEGRATED SYSTEMS AND HEAT REGULATION Comprised of a boiler solar heating heat pump and possibly photovoltaic etc, they are the natural evolution of air-conditioning systems: with very high seasonal yields, low energy consumption and reduced pollutant emissions. They are engineering solutions that can be perfectly integrated with each other, which allow to attain maximum benefit from the various energy production systems on the basis of the respective efficiency parameters. For correct functioning of the entire system, Immergas proposes an "intelligent" System Manager, able to: - always make use of the most convenient heat source; - keep the system performance high in every circumstance; - control and command the entire system with a unique "brain" (i.e. the System Manager). Basically, the System Manager is a supervisor that can control the entire system. Amongst other things, the following main operations are necessary: - to acquire the external temperature (from the external probe, inserted as per standard on the heat pump); - to set the functioning climatic curve to determine the system flow temperature; - configure the fuel cost (e.g. methane); - configure the electric energy cost. The point of economic balance between the condensing boiler and the heat pump is a COP value between 2.3 and 2.5 approximately (approximate value referred to methane); this value changes based on the cost of electrical power and gas, in the location where the system is installed. 5

With an external T. that fulfils the min COP for economical convenience, the heat pump starts up, and the operating conditions/performance will constantly be monitored. On the contrary, if the environmental conditions are such that the AUDAX coefficient of performance tends towards values that are lower than the min COP for economical convenience, the System Manager turns the boiler on (or the integrative resistance), and not the heat pump. Every time AUDAX is operating, the Manager enables an additional control, which checks the time it takes for the system to reaching full operation: when a maximum time has been exceeded (settable), the boiler or the integrative electric resistance is activated in order to reach the T.flow with heat pump. In all cases where radiant panels are also included for summer cooling, alongside dehumidifiers (see previous picture), the System Manager will also monitor the dew point through the installation of temperature/humidity probe kits set up in the room. Thanks to this intelligent function the System Manager can increase the flow temperature to the radiant panels by about 1-2 C (up to a max T. of 20 C - maximum limit of the heat pump), avoiding the phenomenon of condensation on the surface of the structure. This function can only be activated when there is a "Zone control" or "Temperature/ humidity sensor". In some cases, for example, the System Manager can turn the heat pump off if the flow temperature to the radiant panels is not sufficiently corrected. If on the other hand, there is a high temperature zone in the system, in addition to the low temperature one, it will be served exclusively by the boiler through an accordingly configured dedicated expansion connected to the System Manager. In general, the boiler and heat pump do not operate at the same time (except when a high temperature zone is active). Functioning in domestic hot water mode: if the temperature set for the dhw is < 50 C the heat pump will come on (always carrying out the afore-mentioned convenience check); if it is > 50 C, on the other hand, the boiler will come on;- if there is no boiler but there is an integrative electrical resistance on the storage tank, the water is brought to 50 C using the heat pump, after which time AUDAX is disabled leaving the resistance to integrate up to the pre-set value. In systems where there is a boiler or an integrative electrical resistance on the storage tank, in addition to the heat pump, it is also possible to enable the anti-legionella function. 6

7 AUDAX 16/18 kw DIMENSIONS, CONNECTIONS AND MINIMUM INSTALLATION DISTANCES Air vent valve System water outlet 1 1160 A 105.5 185 725 429.5 1382 1241 Main switch Detail A Manometer 401 368 323 System water inlet 1 Electric power supply + auxiliaries 1201 1241 HP service valve LP service valve System water drain valve rear PdC 200 500 top PdC left side 250 right side 500 800 front PdC 9

10 AUDAX 16/18 kw MAIN COMPONENTS 14

KEY: 1 - Rear protective grid 2 - Front left casing 3 - Left side with protective grid 4 - Fan grid 5 - Front casing handle 6 - Front right casing 7 - Ф552 fan 8 - DC 77W 750rpm fan motor 9 - Fan motor support plate 10 - Base plate 11 - High pressure switch 12-4-way valve SHF-20A-46-00 13-4-way valve coil 14 - Compressor unit 15 - Separation plate 16 - Pump/MHI202EM 17 - Pump connector 18-1½" G sealing pad 19 - Liquid separator 20 - Liquid separator support plate 21 - Liquid receiver 22 - Filter 23 - Electronic expansion valve/d24fks 24 - Electronic expansion valve coil 25 - WATER/GAS plate exchanger 26 - Right support plate/phe 27-3 bar safety valve 28 - System pressure point 29 - Right casing side 30 - Gas pressure point/r410a 31 - Right sides connections plate 32 - Manometer 33 - Main switch 34 - Differential water pressure switch WFS1000 8AAF 35 - ¼" SAE probe connector 36 - Cable tie 37-4-pole terminal board 38 - HYDI board 39 - EI/T10EI16A-85 transformer 40 - Display board 41 - Circuit boards support plate 42 - PFC board with communication port /IL- PFCA 43 - Phase protector 44 - Filter board 45 - Condenser board 46 - Board cover plate 47 - Inductance 48 - Compressor inverter board 49 - Heat dissipator 50 - ODU board 51 - Top cover 52 - Brio 5F expansion vessel 53 - Finned coil 54 - Coil fastening plate 55 - NSK-BC high pressure sensor 56 - NSK-S489 high pressure sensor cabling 57 - OAT temperature probe/red 58 - OMT temperature probe/white 59 - OCT temperature probe/blue 60 - IRT temperature probe/black 61 - System return temperature probe (EWT)/ white 62 - System flow temperature probe (LWT)/red 63 - CTT temperature probe 64 - Plate exchanger anti-freeze resistance cabling (E8ECRS018 L=3m) 65 - Cabling 15

12 AUDAX 10/16/18 kw COOLING-HYDRAULIC CIRCUITS DIAGRAM FLOW RETURN KEY: 1 - Compressor 2-4-way valve 3 - Finned coil + fan 4 - Filter 5 - Electronic expansion vessel 6 - Electronic pressure sensor 7 - Water receiver 8 - Plate heat exchanger with resistance electric anti-freeze as per standard 9 - Water tank 10 - Pump 11 - Air vent valve 12-3 bar safety valve 13 - Manometer 14 - Drain valve 15 - Expansion vessel 16 - Differential pressure switch 17 - Low pressure sensor 18 - High pressure sensor 19 - System return water temperature 20 - Compressor outlet temperature 21 - Cooling fluid temperature at half way on finned coil 22 - Installation room temperature 23 - Condens./evap. temperature 24 - Liquid/vapour phase temperature 25 - System flow water temperature 17

16 AUDAX 16 kw TECHNICAL DATA Central heating circuit Power in CH mode with water set at 35 C (1) kw 15.7 Power in CH mode with water set at 45 C (2) kw 15.9 CH mode COP with water set at 35 C (1) 4.15 CH mode COP with water set at 45 C (2) 3.20 Min/max heat power with water set at 35 C (1) kw 5.46 / 17.67 Min/max heat power with water set at 45 C (2) kw 5.60 / 16.40 Electric power absorbed at 35 C/45 C W 3780 / 4980 Flow temperature range C 24 / 55 Cooling circuit Power in cooling mode with water set at 18 C (1) kw 16.5 Power in cooling mode with water set at 7 C (2) kw 15.5 Cooling mode EER with water set at 18 C (1) 3.95 Cooling mode EER with water set at 7 C (2) 2.55 Min/max cooling capacity with water set at 18 C (1) kw 10.86 / 17.52 Min/max cooling capacity with water set at 7 C (2) kw 7.70 / 12.97 Electric power absorbed at 18 C/7 C W 4180 / 6100 Flow temperature range C 5 / 20 General data System max. working pressure bar 3 Total head available at system (with 3.000 l/h flow rate) kpa (m H 2 O) 123.0 (12.9) Expansion vessel capacity l 5 Sound power level db(a) 71 Appliance electric protection rating IP X4 Electric power supply V - Hz 380-50 Maximum power absorbed W 6500 Nominal current absorbed (CH/cooling) A 6.1 / 5.6 Maximum absorbed current from the P.C.B. A 15 Fuse inserted A 20 Refrigerant fluid load (R410A) g 3200 Heat pump weight kg 202 THE REPORTED DATA REFERS TO THE FOLLOWING CONDITIONS: Sound pressure level measured in free field at 1 m from the machine, in compliance with UNI EN ISO 3746/97 ROOM HEATING PHASE ( C) COOLING PHASE ( C) Water TEMP. (F/R) (1) - AIR (db/wb) 35/30-7/6 18/23-35/24 Water TEMP. (F/R) (2) - AIR (db/wb) 45/40-7/6 7/12-35/24 30

16.1 VARIATION OF THE AUDAX 16 POWER IN HEATING kw AUDAX 16 kw: variation of the power output based on the varying external T. and system flow T. Thermal power output in W 26000 24000 22000 20000 18000 16000 14000 12000 10000 8000 6000 4000 2000 35 C 45 C 55 C 35 C 45 C 55 C 0-15 -13-11 -9-7 -5-3 -1 0 1 3 5 7 9 11 13 15 17 19 External temp. in C 40Hz 80Hz AUDAX 16 kw: variation of the absorbed Power based on the varying external T. and system flow T. 8000 Absorbed electric power in W 7500 55 C 7000 6500 45 C 6000 5500 5000 35 C 4500 4000 55 C 3500 3000 45 C 2500 35 C 2000 1500 1000 500 0-15 -13-11 -9-7 -5-3 -1 0 1 3 5 7 9 11 13 15 17 19 External temp. in C 40Hz 80Hz 31

16.2 VARIATION OF THE AUDAX 16 POWER IN COOLING kw 20000 AUDAX 16 kw: variation of the power output based on the varying external T. and system flow T. 18 C 18000 16000 7 C Thermal power output in W 14000 12000 10000 8000 6000 18 C 7 C 4000 2000 0 20/15 25/20 External temp. in C 30/24 35/24 40Hz 80Hz 6000 AUDAX 16 kw: variation of the absorbed Power based on the varying external T. and system flow T. 5500 5000 4500 18 C Absorbed electric power in W 4000 3500 3000 2500 2000 1500 7 C 18 C 7 C 1000 500 0 20/15 25/20 External temp. in C 30/24 35/24 40Hz 80Hz 32

16.3 AUDAX 16 kw CIRCULATION PUMP AUDAX 16 kw is equipped with an incorporated circulation pump. The pump, which is already equipped with a condenser, is connected to the AUDAX supplies in single phase (230 V - 50 Hz). TECHNICAL NOTE: In the presence of systems with fan coils (without water side control probe), it is recommended to check the water content in the system, making sure it is not lower than 250 litres. 16.4 PUMP HEAD/FLOW RATE GRAPHICS 240,0 220,0 200,0 180,0 160,0 Head (kpa) 140,0 120,0 100,0 80,0 A 60,0 40,0 20,0 0,0 0 1000 2000 3000 4000 5000 Flow rate l/h A = Flow rate/head curve available to the system with zone pump at 3 rd speed 33

A B AUDAX 20 AUDAX 16/18 kw CIRCUIT BOARD The AUDAX 16 kw and 18 kw heat pumps are designed to function correctly also without external manager. They must only be set, using the "HMI" panel, to work appropriately in the specific system. KEY: PS - Pressure sensor ET - Return temperature LT - Flow temperature IRT - Liquid phase temperature FM - Heating/Cooling selection (optional) NM - DHW or low consumption mode selection (optional) FS - Differential pressure switch SB - On/Off selector (optional) E - Pump HMI - Operator panel HST - P.C.B. temperature CTT - Compressor discharge temperature OCT - Evaporation temperature OAT - External temperature OMT - Coil temperature EEV - Electronic valve OFAN UP - Upper fan OFAN DOWN - Lower fan QS - Main switch COMP - Compressor RV - Reversing valve HPS - High pressure switch LPS - Low pressure switch FAN UP FAN DOWN OFAN UP OFAN DOWN F201 T3.15A 250V ODU OCT OMT Esc Up Down OAT CTT Sel DRIVER EEV Esc HMI Up Down Sel FILTER HYDI PS ET LT IRT AntiFreeze SETTINGS 1 2 3 4 Mode ON OFF OFF OFF MODBUS OFF ON OFF OFF 0-10 V ON ON OFF OFF Fixed stp. OFF OFF ON OFF CRT 1 2 3 4 ON DIP ON P11 PS P4 EWT P1 LWT P3 IRT E MODBUS GND +5V FM NM FS SB cables with a section between 0.5 and 1.5 mm2 QS cables with a min. section of 4 mm2 Power supply 380 Vac 50Hz 40

21 PRELIMINARY CONTROL PANEL SETTINGS User Interface (HMI) Once the machine has been electrically powered, the screen displays the software version 3 consecutive times, and then goes into stand-by mode (SB). Using the UP/DOWN buttons it is possible to scroll through the 3 main menus: - DIAGNOSTICS (dia): this displays the current alarms/alarm log of the board hydraulics (HYDI) and inverter board (ODU) - SETUP (StP): this allows you to set the parameters of the machine - STATUS (Stt): this displays the status of the (HYDI) and (ODU) boards The "STATO (STATUS)" menu and its submenus, once they have been selected, automatically go back to the main menu after no keys have been pressed for 60 consecutive minutes. The other menus go back to the main menu after 10 min. When numerical and alphanumerical characters are shown at the same time, they are separated by a period. Example of the AUDAX menu: 1 st level 2 nd level 3 rd level Description Default SETTINGS (STP) CAP 0-4 dl A, B, C, D LoT 0, 1 Set machine capacities 3 AUDAX 6 4 AUDAX 8/10/16/18 Set machine model A AUDAX 6/8/10/16/18 If the machine is configured to be managed by an external 0-10 V signal (switch setting) the LoT parameter specifies the meaning of the external signal. 0 Power management 1 Flow temperature management SPC 5-20 Set cooling water flow set-point 7 0 A 0 SPH 24-55 Set heating water flow set-point 45 Set operating mode ode Sb, H, C Sb Stand-by H Heating Mode C Cooling Mode Sb SETTINGS (STP) FCD 0, 1 br 1.2, 9.6 Add 0 247 Set machine control mode 0 Control through User Interface HMI 1 Control through contacts on HYDI board Set data transfer speed 1. 1.2 Connection with chrono-thermostat (1200 bit/s) 9.6 Connection with chrono-thermostat (9600 bit/s) Set Modbus address Set at 1 by default (do not change) 0 9.6 1 nod 0, 1 Enable Night Mode or Domestic Water 0 Enable Night Mode 1 Enable boiler operation (Domestic Water) 0 41

26 EXPANSION BOARD FOR ZONE MANAGEMENT (CODE 3.021547) This component must be powered at 24 Vac and is mainly used for system zone management; in particular n 1 expansion kit must be used for each zone. The expansion kit manages pump, mixing valve and the dehumidifier of the same zone, acquiring the room request (temperature and humidity) for a determined zone. The following can be connected to this kit: - the room temperature - humidity sensor; - an ON-OFF type request contact. Installation takes place on a DIN guide for electric components from control board. This board is envisioned as per standard in the 2 kits for zone systems (see page 46 and 47). 27 ZONE CONTROL (CODE 3.021523) It is an electronic device with display, for the regulation of temperature and relative humidity in the rooms. Connection with the system manager kit is envisioned via the RS485 plan network. Programming relative to room heat adjustment stays under the control of the System Manager kit. The distance of the assembly holes is studies in order to fix the device to a recess box in compliance with IEC Standards. It can be fixed to the wall using the plugs supplied. The kit must be powered at 24 Vac. 28 ROOM TEMPERATURE-HUMIDITY SENSOR (CODE 3.021524) It is a room temperature and humidity probe, to be applied to the wall. Differently to the zone control kit, in this case, the settings of all room parameters take place on the System manager kit. The kit must be connected directly to the expansion board for zone management. The kit must be powered at 24 Vac. 29 THERMOSTAT FOR WEEKLY HEATING/ COOLING MANAGEMENT (CODE 3.021521) It is a temperature controller with user interface with keys + LCD. The ON-OFF type device, which is connected directly to AUDAX, cannot be used with the System manager kit: - it is connected using 4 wires (2 supply and 2 communication); - 1 h programming step; - it allows you to set the heating/cooling flow temp, working as remote; - it allows you to choose hot or cold operation. 45

During the useful life of the products, performance is affected by external factors, e.g. the hardness of the DHW, atmospheric agents, deposits in the system and so on. The data declared refer to new products that are correctly installed and used with respect to the Standards in force. N.B.: correct periodical maintenance is highly recommended. NOTE: Depending on the specific design and installation conditions, the diagrams and drawings provided in this documentation can require further integration or modifications, according to that envisioned by the Standards and technical regulations in force and applicable (as an example, Collection R - edition 2009 is stated). It is the professional's responsibility to identify the provisions applicable, to evaluate the compatibility with these case by case and the necessity of any changes to drawings and elaborations. Immergas reserves the right to make any modifications to its models, which are believed useful for the development of the product, without forewarning. Code S.0152 rev. 001-05/2012 - Technical Marketing Management To request further specific details, professionals in the sector can use the following e-mail: Design, manufacture and after-sales assistance of gas boilers, gas water heaters and relative accessories