ML 1 80 UH 070 X E 36 B

Similar documents
ML180UH. MERIT SERIES Upflow / Horizontal. AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons ML 1 80 UH 070 X P 36 B

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

MERIT SERIES Upflow / Horizontal

MERIT SERIES Up Flow / Horizontal

AFUE - 80% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling to 5 Tons GAS FURNACES ML180UHE

ELITE SERIES Upflow / Horizontal - Two-Stage Heat

ELITE SERIES Downflow - High Efficiency Blower Motor

MERIT SERIES Downflow

ML180UHT (ce) MERIT SERIES Upflow / Horizontal 50HZ. Net Input to 34.8 kw Nominal Add-on Cooling to 17.

ML 1 93 UH 070 x P 36 B

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

MERIT SERIES Upflow / Horizontal

G61MP. ELITE Series Multi-Position - Two-Stage Heat. AFUE - Up to 95% Input - 44,000 to 132,000 Btuh Nominal Add-on Cooling - 2.

MERIT SERIES Upflow / Horizontal

G61MP. ELITE SERIES Multi Position Two Stage Heat G A S F U R N A C E S. AFUE 94.1% Input 44,000 to 132,000 Btuh Nominal Add on Cooling 2.

MERIT SERIES Upflow / Horizontal

MERIT SERIES Downflow

ELITE SERIES Upflow / Horizontal - High Efficiency Blower Motor

8+* Bulletin No November 1997

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

Heavy Duty Transformer. Low Voltage Circuit Breaker. Visit us at For the latest technical information,

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

13 GEP A L P - 1 A

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

MERIT SERIES Downflow

DuralokPlus Aluminized Steel Heat Exchanger G 32 V

RGE 13 A T - 1 A

G34M Bulletin #69/ August 2003

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

G60UH(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

G60UHV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

DAVE LENNOX SIGNATURE COLLECTION Upflow / Horizontal - Variable Capacity - Variable Speed Blower

SLP98UHV WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

WATER HEATERS / BOILERS GSB8-E. Gas-Fired Steam Boiler PRODUCT SPECIFICATIONS. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB E

AFUE 95% Heating Input 50,000 to 200,000 Btuh

TECHNICAL SPECIFICATIONS

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

FG7T (C and L Series)

TECHNICAL SPECIFICATIONS

GSB8. CONSERVATOR Gas-Fired Steam Boiler. AFUE up to 82.7% Heating Input 75,000 to 299,000 Btuh GSB S MODEL NUMBER IDENTIFICATION FEATURES

GSR21Q PULSE21 SERIES

TECHNICAL SPECIFICATIONS

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

GSR21Q GAS FURNACES EXISTING NEG EXISTING NEG ENGINEERING DATA HORIZONTAL POSITION. Typical Applications DOWN-FLO POSITION

G51MP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

MERIT Series R-410A - Upflow / Horizontal

G60DFV(X) WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

LF24. UNIT HEATERS Horizontal - 60 HZ. Thermal Efficiency - up to 80.5% Input - 100,000 to 390,000 Btuh LF A MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

KG6TE Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

EL195UH WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. EL195UH SERIES UNITS

XC80 TUD2B060ACV32A TUD2B080ACV32A TUD2C080ACV42A TUD2B100ACV32A TUD2C100ACV52A TUD2D120ACV52A TUD2D140ACV52A

Product Data. CBLAAA LOW-BOY OIL FURNACE INPUT RATES: 70,000 thru 154,000 BTUH SERIES 140

80% Variable Speed, Two Stage Heating Furnace. Cooling Capacity CFM in. w.c. (125 Pa)

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

G6RC Series TECHNICAL SPECIFICATIONS

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

Upflow/Downflow Horizontal Right or Left Gas-Fired Furnace

Corp L12 Revised G24M SERIES UNITS

Product Data. 95% AFUE Single Stage Furnace Upflow / Downflow / Horizontal. ama ! WARNING

TECHNICAL GUIDE MODELS: P*DH GAS-FIRED CONDENSING / HIGH EFFICIENCY DOWNFLOW / HORIZONTAL FURNACES 91 AFUE DESCRIPTION WARRANTY FEATURES

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Downflow/Horizontal Right Induced Draft Gas Furnace

AFUE up to 85.2% Heating Input 105,000 to 245,000 Btuh

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

G41UF WARNING. Service Literature G41UF SERIES UNITS. Table of Contents

MERIT SERIES Up Flow / Horizontal

Upflow/Horizontal Condensing, Gas-Fired Furnace

FORM NO. G REV. 2 Supersedes Form No. G Rev. 1 GAS FURNACES

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

RG7D 1-Stage Heat Series

VNE GAS FURNACE 2- STAGE VARIABLE SPEED UPFLOW/HORIZONTAL

TZ95MSX SERIES Model with Input Rates from 40 to 115 kbtu [11.72 to kw] (All Models 95% A.F.U.E. )

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

GAS FURNACES SUPER QUIET 80 TWO STAGE 80% A.F.U.E. DOWNFLOW GAS FURNACES

F8AUH Gas Furnaces Up-Flow/Horizontal

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

GAS FURNACES SILHOUETTE II PLUS 2 LXE TWO STAGE 80% A.F.U.E. UPFLOW/HORIZONTAL GAS FURNACES

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

GAS FURNACES. Communicating Furnace Thermostat. FORM NO. G Supersedes Form No. G RHC-TST550CMMS MID HIGH

ELITE SERIES Downflow - Two-Stage Heating - Variable Speed Blower

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

Transcription:

PRODUCT SPECIFICTIONS GS FURNCES ML80UHE MERIT SERIES Upflow / Horizontal - High Efficiency Blower Motor Bulletin No. 2063 ugust 202 Supersedes January 202 FUE - 80% Input - 44,000 to 32,000 Btuh Nominal dd-on Cooling -.5 to 5 Tons MODEL NUMBER IDENTIFICTION ML 80 UH 070 X E 36 B Unit Type ML = Merit Series Stages = Single-Stage FUE 80 = 80% Configuration UH = Upflow/Horizontal Nominal Gas Heat Input 045 = 44,000 Btuh 070 = 66,000 Btuh 090 = 88,000 Btuh 0 = 0,000 Btuh 35 = 32,000 Btuh Cabinet Width = 4-/2 in. B = 7-/2 in. C = 2 in. D = 24-/2 in. Nominal dd-on Cooling Capacity 36 =.5-3 tons 48 = 2.5-4 tons 60 = 3-5 tons Blower E = High Efficiency Constant Torque Blower Motor Low NO x = Units meet California Nitrogen Oxides standards Indoor coils with the same letter designation will physically match the furnace.

FETURES J Contents Blower Data..................... 3 Dimensions - Furnace/Coil Combined Dimensions. 2 B Dimensions - Horizontal Position........... 0 F Dimensions - Upflow Position............. 9 Features........................ 2 Gas Heat ccessories................. 8 High ltitude Derate.................. 8 Installation Clearances................. 7 G D L E C Model Number Identification.............. Optional ccessories.................. 8 Optional ccessory Dimensions........... Specifications..................... 7 K I H NOTE - ML80UHE FURNCES RE NOT VILBLE IN CND! WRRNTY Duralok luminized Steel Heat Exchanger - Limited twenty year warranty in residential applications, ten years in non-residential applications. ll other covered components - Limited five year warranty in residential applications, one year in nonresidential applications. Refer to Lennox Equipment Limited Warranty certificate included with equipment for details. PPROVLS Units are Certified by HRI. Units tested and rated according to US DOE test procedures and FTC labeling regulations. X models approved by the California Energy Commission and meet California Seasonal Efficiency requirements and California Nitrogen Oxides (NOx) Standards. ISO 900 Registered Manufacturing Quality System. Blower data from unit tests conducted in Lennox Laboratory air test chamber. ML80UHE / Page 2 PPLICTIONS Input capacities of 44,000, 66,000, 88,000, 0,000 and 32,000 Btuh. Energy efficiency (FUE) of 80%. Compact cabinet for upflow, horizontal-left or horizontalright applications. Utility room, alcove, closet, crawl space, basement or attic installation. Lennox add-on indoor coils, high-efficiency air cleaners and humidifiers can easily be added to furnace. Shipped factory assembled with all controls installed and wired. Ready for installation in upflow or horizontal right-hand position without any modifications. Horizontal left-hand position requires repositioning of pressure switch. Removable bottom seal panel shipped in place for side return air is easily removed for bottom/end return air applications. Each unit factory test operated to ensure proper operation. NOTE - FURNCES CNNOT BE TWINNED!

B C D E F FETURES HETING SYSTEM Lennox Duralok Heat Exchanger ssembly Heavy gauge aluminized steel heat exchanger. Crimped seam clamshell type design. Designed for normal expansion and contraction. Inshot Burners Minimum resistance to air flow. Heat exchanger has been laboratory life cycle tested in excess of industry standards. Compact size of heat exchanger permits low overall design of furnace cabinet. luminized steel inshot burners provide efficient, trouble-free operation. Burner venturi mixes air and gas in correct proportion for proper combustion. Burner assembly is removable from the unit as a single component for ease of service. SureLight Hot Surface Ignitor Tough, reliable, long-life, trouble-free performance. Silicon nitride ignitor. Cemented to steatite block for protection against current leakage. Ignition leads are constructed of nickel plated copper and are enclosed in high temperature Teflon insulation for dependable operation. Gas Control Valve 24 volt redundant combination gas control valve combines manual shut off switch (On-Off), automatic electric valve (dual) and gas pressure regulation into a compact combination control. Combustion ir Inducer Shaded pole heavy duty blower prepurges heat exchanger and safely vents flue products. Pressure switch proves blower operation before allowing gas valve to open. Operates only during heating cycle. Direct access allows inducer assembly to be rotated 90 clockwise or counterclockwise to facilitate easy vent attachment from either side of the cabinet in upflow applications and from the top in horizontal applications. G H Flame Rollout Switches (2) Manual reset switches are factory installed on burner box. Switches provides protection from abnormal operating conditions. Limit Control utomatic reset, primary limit is accurately located on vestibule panel on all units. OPTIONS High ltitude Pressure Switch Kit Required on most units for proper unit operation at altitudes from 4,50 to 7500 ft. Natural Gas to LPG/Propane Conversion Kit Required for field changeover from natural gas to LPG/ Propane. LPG/Propane to Natural Gas Conversion Kit Required for field changeover from LPG/Propane to natural gas. Vent daptor (Upflow pplications Only) llows venting through a masonry chimney without the need of a flue liner. Manual reset temperature sensor protects against abnormal operating conditions. Sensor wiring may be routed from either side of adaptor. Minimum winter design temperatures: 0 F when used with interior masonry chimneys. +5 F when used with exterior masonry chimneys. Refer to Winter Design Temperatures Map on page 6 for application information. lso refer to the installation instructions for detailed information. BLOWER Direct drive blower. Statically and dynamically balanced. Resiliently mounted. Blower assembly easily removed for servicing. DC Brushless Motor High Efficiency Constant Torque. ECM (Electronically Commutated Motor). 6 in. (52 mm) 7 in. (78 mm) Motor is programmed to provide constant torque at each of the selectable speeds. Motor is controlled by the Integrated Furnace Control. Blower speeds are easily changed on the integrated furnace control. See blower performance tables. ML80UHE / Page 3

FETURES I CONTROLS SureLight Integrated Furnace Control Control contains all necessary controls and relays to operate furnace. Combustion air inducer is operated by the integrated furnace control. Prior to ignition, a pre-purge cycle for 5 seconds is initiated. fter the main burners are turned off, a post-purge cycle for 5 seconds is run. Flame sensor assures safe and reliable operation. Should loss of flame occur the integrated furnace control will initiate 4 re-attempts at ignition before locking out unit operation for 60 minutes. Watchguard type circuit automatically resets ignition controls after one hour of continuous thermostat demand after unit lockout, eliminating nuisance calls for service. Fan control consists of adjustable blower timed-off delay (60, 90, 20, 80 seconds - factory setting 90 seconds) and fixed blower timed-on delay (30 seconds - heating, 2 seconds - cooling). For air-conditioning applications, blower is automatically energized on thermostat demand for cooling. Control has low speed continuous blower speed setting for humidifier or air cleaner operation. Two accessory terminals furnished for additional power supply requirements for 20 volt (less than amp) power humidifiers and powered air cleaners. One additional terminal is furnished for power supply requirements for 24V (less than 0.5 amp) low voltage accessories. Ignition control has single red LED to indicate status and as an aid in troubleshooting. Last five codes are stored in non-volatile memory (accessible by recall button on control) for servicing. 24 Volt Transformer Furnished and factory installed on outside of control box. 40V transformer has fuse wired in series. Field Wiring Make-up Box Furnished for line voltage wiring. Factory installed internally on left side of furnace. Box may be installed on right side of furnace. OPTIONS Blower Relay Kit (For Use With Two-Stage Outdoor Units) llows furnace blower speed changes when matched with two-stage air conditioners or heat pumps. Thermostat Thermostat (programmable/non-programmable) is not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book for selection. Night Service Kit Contains most commonly used service parts: Furnace Control Ignitor Flame sensor Gas valve Transformer Universal Service Kit - Switches Kit contains: Primary limits (for each model) Pressure switches (for each model) Flame rollout switches (for each model) FILTER (NOT FURNISHED) Filter and provisions for external mounting must be field provided. OPTIONS ir Filter and Rack Kit for Horizontal Return ir (End) pplications Washable or vacuum cleanable polyurethane frame type filter and external end return air rack available for field installation. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. See dimension drawing. ir Filter and Rack Kit for Upflow Side Return ir pplications - Not for use with Return ir Base Washable or vacuum cleanable polyurethane frame type filter and external side return air rack available for field installation. vailable in single and ten pack kits. Rack has filter door for easy filter servicing. Flanges on rack allow easy duct connection. Field installs on either side of unit cabinet. See dimension drawing. ML80UHE / Page 4

FETURES J K L CBINET Low-profile, narrow width cabinet allows easy installation. Heavy-gauge, cold rolled steel construction. Pre-painted cabinet finish. Flue outlet on top of cabinet for upflow applications, can be relocated to either side of cabinet for horizontal applications. Flanges provided on supply air opening for ease of plenum connection or alignment with indoor coil. Insulated cabinet with foil faced insulation on sides and back of heating compartment. Sealed blower compartment. Inner blower compartment access panel seals blower compartment from air leakage. Complete service access. Safety interlock switch automatically shuts off power to unit when blower compartment access panel is removed. Gas piping and electrical inlets are provided in both sides of cabinet. Return ir Entry: For bottom/end return-air entry for upflow/horizontal applications, remove furnished bottom seal panel from cabinet. For side return-air entry (upflow applications only), corners are marked on either side of cabinet for return air cut-outs. See dimension drawings. NOTE - 60C and 60D size units that require air volumes over 800 cfm must have one of the following:. Single side return air with transition, to accommodate 20 x 25 x in. cleanable air filter. Required to maintain proper air velocity. 2. Single side return air with Optional Return ir Base 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. Coil Match-up ll furnaces exactly match C33 and CX34 cased upflow indoor coils and CH33 horizontal indoor coils with same letter designation in model number. No adaptor required. Engaging holes furnished on cabinet for alignment. C33 uncased coils match furnaces without any overhang but require an optional adaptor base or field fabricated transition to match furnace opening. See C33 coil bulletin for additional information. OPTIONS Horizontal Suspension Kit Provides suspension of unit and indoor coil in horizontal applications. llows complete service access. Consists of corner mounted hanging brackets with vibration isolators, return air end support rail and hardware for assembly. Metal hanging straps must be field provided. Return ir Base field fabricated transition or Return ir Base is required when using an IQ product higher than 4-3/6 in. installed next to the unit and serviced from the front. IQ products higher than 20 in. require a field fabricated transition. Base must be used for 60C and 60D models with air volumes over 800 cfm in upflow applications when only one side return is required. Cabinet is shipped flat for easy field assembly and is pre-painted steel to match the furnace. See Dimension Drawing. ML80UHE / Page 5

99% WINTER DESIGN TEMPERTURES FOR THE CONTIGUOUS UNITED STTES 5 o F 0 o F 7 o F 27 o F 0 o F 5 o F 37 o F 0 o F 7 o F 27 o F 37 o F This map is a necessarily generalized guide to temperatures in the contiguous Unites States. Temperatures shown for areas such as mountainous regions and large urban centers may not be accurate. The data used to develop this map was taken from the 993 SHRE Fundamentals Handbook (Chapter 24, Table : Climate Conditions for the United States). Reprinted with permission from NFP 54: National Fuel Gas Code 999, National Fire Protection ssociation, Quincy, M 02269. This reprinted material is not the complete and official position of the National Fire Protection ssociation on the referenced subject, which is represented only by the standard in its entirety. ML80UHE / Page 6

SPECIFICTIONS Gas Model No. ML80UH045E36 ML80UH070E36B ML80UH090E48B Heating Model No. - Low Nox ML80UH045XE36 ML80UH070XE36B ML80UH090XE48B Performance FUE 80% 80% 80% Input - Btuh 44,000 66,000 88,000 Output - Btuh 36,000 53,000 72,000 Temperature rise range - F 5-45 40-70 35-65 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 High Static - in. w.g. 0.50 0.50 0.50 Connections Flue connection - in. round 4 4 4 in. Gas pipe size IPS /2 /2 /2 Indoor Blower Electrical Data Wheel nom. dia. x width - in. 0 x 8 0 x 0 0 x 0 Motor Type DC Brushless DC Brushless DC Brushless Motor output - hp /2 /2 3/4 Tons of add-on cooling.5-3.5-3 2.5-4 ir Volume Range - cfm 350-380 395-45 750-785 Voltage 20 volts - 60 hertz - phase Blower motor full load amps 6.8 6.8 8.4 Maximum overcurrent protection 5 5 5 Shipping Data lbs. - package 27 42 SPECIFICTIONS Gas Model No. ML80UH090E60C ML80UH0E60C ML80UH35E60D Heating Model No. - Low Nox - - - ML80UH0XE60C - - - Performance FUE 80% 80% 80% Input - Btuh 88,000 0,000 32,000 Output - Btuh 72,000 90,000 07,000 Temperature rise range - F 30-60 35-65 30-60 Gas Manifold Pressure (in. w.g.) Nat. Gas / LPG/Propane 3.5 / 0.0 3.5 / 0.0 3.5 / 0.0 High Static - in. w.g. 0.50 0.50 0.50 Connections Flue connection - in. round 4 4 4 in. Gas pipe size IPS /2 /2 /2 Indoor Blower Electrical Data Wheel nom. dia. x width - in. -/2 x 0 -/2 x 0 x Motor Type DC Brushless DC Brushless DC Brushless Motor output - hp Tons of add-on cooling 3-5 3-5 3.5-5 ir Volume Range - cfm 990-2290 920-235 40-2495 Voltage 20 volts - 60 hertz - phase Blower motor full load amps 0.9 0.9 0.9 Maximum overcurrent protection 5 5 5 Shipping Data lbs. - package 52 60 78 NOTE - Filters and provisions for mounting are not furnished and must be field provided. nnual Fuel Utilization Efficiency based on DOE test procedures and according to FTC labeling regulations. Isolated combustion system rating for non-weatherized furnaces. INSTLLTION CLERNCES - INCHES (MM) UPFLOW POSITION Vent Type Type B Type C Sides 0 (0) 0 (0) Rear 0 (0) 0 (0) Top (25) (25) Front 2-/4 (57) 2-/4 (57) Front (service/alcove) 24 (60) 24 (60) Floor Combustible Combustible Flue (25) 6 (52) NOTE ir for combustion must conform to the methods outlined in the National Fuel Gas Code (NFP 54/NSI-Z223.). NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFP 54/NSI-Z223.) or applicable provisions of local building codes. Left side requires 4 in. if single wall vent is used on 4-/2 in. cabinets, 2 in. on 7-/2 in. cabinets. HORIZONTL POSITION Vent Type Type B Type C End 2 2 Rear 0 (0) 0 (0) Top 0 (0) 0 (0) Front 2-/4 (57) 2-/4 (57) Front (service) 24 (60) 24 (60) Floor Combustible Combustible Flue (25) 6 (52) NOTE ir for combustion must conform to the methods outlined in the National Fuel Gas Code (NFP 54/NSI-Z223.). NOTE In the U.S. flue sizing must conform to the methods outlined in the current National Fuel Gas Code (NFP 54/NSI-Z223.) or applicable provisions of local building codes. Line contact installation permissible between jacket top or sides and building joists. ML80UHE / Page 7

OPTIONL CCESSORIES - ORDER SEPRTELY NOTE - FURNCES CNNOT BE TWINNED! CBINET CCESSORIES Width Models B Width Models C Width Models D Width Models Horizontal Suspension Kit - Horizontal only 5W0 5W0 5W0 5W0 Return ir Base - Upflow only 65W75 50W98 50W99 5W00 CONTROLS Blower Relay Kit (for two-stage outdoor units) 85W66 85W66 85W66 85W66 FILTERS ir Filter and Rack Kit Horizontal (end) 87L95 87L96 87L97 87L98 SERVICE KITs Size of filter - in. 4 x 25 x 8 x 25 x 20 x 25 x 25 x 25 x Side Return Single 44J22 44J22 44J22 44J22 Ten Pack 66K63 66K63 66K63 66K63 Size of filter - in. 6 x 25 x 6 x 25 x 6 x 25 x 6 x 25 x Night Service Kit 84W47 84W47 84W47 84W47 Universal Service Kit - Switches 89W9 89W9 89W9 89W9 VENTING Vent daptor 6 in. conn. size upflow applications only 8M79 8M79 8M79 8M79 Cleanable polyurethane, frame-type filter. GS HET CCESSORIES Input High ltitude Pressure Switch Kit Natural Gas to LPG/Propane Kit LPG/Propane to Natural Gas Kit Natural Gas High ltitude Orifice Kit 0-4500 ft. 450-7500 ft. 750-0,000 ft. 0-7500 ft. 750-0,000 ft. 0-7500 ft. 750-0,000 ft. 045 No Change 80W52 80W5 70W89 76W5 73W8 73W37 070 No Change 80W52 80W5 70W89 76W5 73W8 73W37 090 No Change 80W52 80W5 70W89 76W5 73W8 73W37 0 No Change 80W52 80W52 70W89 76W5 73W8 73W37 35 No Change 80W52 80W5 70W89 76W5 73W8 73W37 HIGH LTITUDE DERTE NOTE - Units may be installed at altitudes up to 2000 ft. above sea level without any modifications. t altitudes above 2000 ft. units must be derated to match information in the shaded areas shown below. NOTE - This is the only permissible derate for these units. Gas Manifold Pressure (Outlet) in. w.g. Line Pressure - in. w.g. Input 0-2000 Feet 200-4500 Feet 450-7500 Feet 750-0,000 ft. Minimum Natural Gas LPG/ Propane Natural Gas LPG/ Propane Natural Gas LPG/ Propane Natural Gas LPG/ Propane Natural Gas LPG/ Propane Maximum 045 3.5 0 3.2 0 3 0 3.5 0 4.5 3 070 3.5 0 3.2 0 2.8 0 3.5 0 4.5 3 090 3.5 0 3.2 0 2.7 9.6 3.5 0 4.5 3 0 3.5 0 3.5 0 3 9.6 3.5 0 4.5 3 35 3.5 0 3.5 0 2.9 9.6 3.5 0 4.5 3 Natural Gas High ltitude Orifice Kit required. ML80UHE / Page 8

DIMENSIONS - INCHES (MM) - UPFLOW POSITION NOTE - 60C and 60D size units that require second stage air volumes over 800 cfm (850 L/s) must have one of the following:. Single side return air with transition, to accommodate 20 x 25 x in. (508 x 635 x 25 mm) cleanable air filter. Required to maintain proper air velocity. 2. Single side return air with optional Return ir Base 3. Bottom return air. 4. Return air from both sides. 5. Bottom and one side return air. See Blower Performance Tables for additional information. D FLUE OUTLET (Top) 3-/8 (79) SUPPLY IR OPENING 2 Flue outlet may be horizontal but furnace must be vented vertically 3 Optional External Side Return ir Filter Kit is not for use with the optional Return ir Base. 3 OPTIONL EXTERNL SIDE RETURN IR FILTER KIT (Either Side) 23-3/4 (603) 25 (635) TOP VIEW B 9/6 (4) 3/4(9) Front Panel 3 (76) Right 6-3/4 (7) Left 3-/4 (83) 27-3/4 (705) 9-7/6 (494) 9/6 (4) 3 OPTIONL EXTERNL SIDE RETURN IR FILTER KIT (Either Side) 33 (838) 9-/8 (232) Right 8-5/8 (29) Left 5-3/8 (37) Right 2-3/6 (56) Left 2 FLUE OUTLET (Either Side) ELECTRICL INLET (Either Side) GS PIPING INLET (Either Side) 4-3/4 (375) 6 (406) ELECTRICL INLET (Either Side) 23 (584) Side Return ir Opening (Either Side) 4 (356) -/2 (38) -5/6 (49) 3/4 (9) C Bottom Return ir Opening 3/4 (9) 5/8 (6) 3-/4 (83) 23-/2 (597) Bottom Return ir Opening FRONT VIEW SIDE VIEW Model No. B C D in. mm in. mm in. mm in. mm ML80UH045E36 4-/2 368 3-3/8 340 3 330 4-3/4 2 ML80UH070E36B ML80UH090E48B ML80UH090E60C ML80UH0E60C 7-/2 446 6-3/8 46 6 406 6-/4 59 2 533 9-7/8 504 9-/2 495 8 203 ML80UH35E60D 24-/2 622 23-3/8 594 23 584 9-3/4 248 ML80UHE / Page 9

DIMENSIONS - INCHES (MM) - HORIZONTL POSITION Flue outlet may be from end but furnace must be vented vertically 9-/8 (232) Top 8-5/8 (29) Bottom FLUE OUTLET (Top) 3 (76) LEFT-HND IR DISCHRGE GS PIPING INLET (Top or Bottom) IR FLOW ELECTRICL INLET (Top or Bottom) 3/4 (9) Front Panel 27-3/4 (705) 9/6 (4) FLUE OUTLET (End) 6-3/4 (7) TOP VIEW 33 (838) 5-3/8 (37) Top 2-3/6 (56) Bottom 3/4 (9) 27-3/4 (705) 9/6 (4) 9-7/6 (494) SUPPLY IR OPENING B D IR FLOW 4-/4 (08) C 23-/2 (597) RETURN IR OPENING END VIEW 3-/8 (79) FRONT VIEW RIGHT-HND IR DISCHRGE END VIEW ELECTRICL INLET (Top or Bottom) IR FLOW GS PIPING INLET (Top or Bottom) 6-3/4 (7) Flue outlet may be horizontal but furnace must be vented vertically FLUE OUTLET (Top) 3/4 (9) Front Panel 3 (76) 27-3/4 (705) 2-3/6 (56) Top 5-3/8 (37) Bottom TOP VIEW 33 (838) 8-5/8 (29) Top 9-/8 (232) Bottom FLUE OUTLET (End) 27-3/4 3-/8 (705) (79) 23-/2 (597) RETURN IR OPENING C 4-/4 (08) IR FLOW D 9-7/6 (494) SUPPLY IR OPENING B 9/6 (4) END VIEW 3/4 (9) FRONT VIEW END VIEW 9/6 (4) Model No. B C D in. mm in. mm in. mm in. mm ML80UH045E36 4-/2 368 3-3/8 340 3 330 4-3/4 2 ML80UH070E36B ML80UH090E48B 7-/2 446 6-3/8 46 6 406 6-/4 59 ML80UH090E60C ML80UH0E60C 2 533 9-7/8 504 9-/2 495 8 203 ML80UH35E60D 24-/2 622 23-3/8 594 23 584 9-3/4 248 ML80UHE / Page 0

OPTIONL CCESSORY DIMENSIONS - INCHES (MM) HORIZONTL (END) FILTER KIT 5/8 (6) 24 3/4 (629) -/4 (32) 5/8 (6) B RETURN IR OPENING 23 /2 (597) 5/8 (6) IR FLOW Furnace Cabinet Width Catalog Number B in. mm in. mm 87L95 4 356 2-3/4 324 B 87L96 8 457 6-3/4 425 C 87L97 2 533 8-3/4 476 D 87L98 25 635 23-3/4 603 5/8 (6) SIDE VIEW IR FILTER (Furnished) FRONT VIEW Optional Return ir Base (Upflow pplications Only - For use with, B, C and D cabinets) FURNCE FRONT IR FLOW INDOOR IR QULITY CBINET (PCO, Filter Cabinet, etc.) IF BSE IS USED WITHOUT IQ CBINET, SINGLE RETURN IR PLENUM MUST COVER BOTH UNIT ND RETURN IR BSE OPENINGS 3-/4 (83) 7-/4 (84) 23 (584) Overall (Maximum) Unit side return air Opening 5-5/8 (43) Minimum (279) 2 Maximum 4 (356) SIDE RETURN IR OPENINGS (Either Side) 22-7/6 (570) Overall (Maximum) 4-/2 (368) Width (65W75) 7-/2 (446) B Width (50W98) 2 (533) C Width (50W99) 24-/2 (622) D Width (5W00) OPTIONL RETURN IR BSE 26-7/8 (683) 23 (584) SIDE VIEW 3/4 (9) NOTE- Optional Side Return ir Filter Kits are not for use with Optional Return ir Base. Both the unit return air opening and the base return air opening must be covered by a single plenum or IQ cabinet. Minimum unit side return air opening dimensions for units requiring 800 cfm or more of air (W x H): 23 x in. (584 x 279 mm). The opening can be cut as needed to accommodate plenum or IQ cabinet while maintaining dimensions shown. Side return air openings must be cut in the field. There are cutting guides stenciled on the cabinet for the side return air opening. The size of the opening must not extend beyond the markings on the furnace cabinet. 2 To minimize pressure drop, the largest opening height possible, up to 4 in. (356 mm), is preferred. ML80UHE / Page

DIMENSIONS - INCHES (MM) - FURNCE/COIL COMBINED DIMENSIONS 33 (838) B UPFLOW POSITION Uncased Cased Model No (CX34 - cased only) B B CX34 C33 in. mm in. mm in. mm in. mm - - - C33-8 2-/2 38 45-/2 56 9-3/4 248 42-3/4 086 CX34-9-6F C33-9 6-/2 49 49-/2 257 9-3/4 248 42-3/4 086 - - - C33-24 6-/2 49 49-/2 257 4 356 47 94 CX34-8/24-6F CX34-8/24B-6F C33-24B CX34-8/24C-6F C33-24C 6-/2 49 49-/2 257 3-7/8 352 46-7/8 9 CX34-25-6F C33-25 8-/2 470 5-/2 308 6-/4 43 49-/4 25 CX34-25B-6F C33-25B 8-/2 470 5-/2 308 5-7/8 403 48-7/8 24 CX34-30B-6F C33-30B CX34-30C-6F C33-30C 20-/2 52 53-/2 359 7-3/4 45 50-3/4 289 CX34-30-6F C33-30 20-/2 52 53-/2 359 8 457 5 295 CX34-3-6F C33-3 22-/2 572 55-/2 40 2-/4 540 54-/4 378 CX34-3B-6F C33-3B 22-/2 572 55-/2 40 20-/4 54 53-/4 353 CX34-36-6F C33-36 24-/2 622 57-/2 46 22-/8 562 55-/8 400 CX34-36B-6F C33-36B 24-/2 622 57-/2 46 2-7/8 556 54-7/8 394 CX34-36C-6F C33-36C 24-/2 622 57-/2 46 2-/4 540 54-/4 378 CX34-38-6F C33-38 24-/2 622 57-/2 46 22-/4 565 55-/4 403 CX34-38B-6F C33-38B 24-/2 622 57-/2 46 22 559 55 397 CX34-42B-6F C33-42B 24-/2 622 57-/2 46 2-7/8 556 54-7/8 394 CX34-43B-6F C33-43B 27-/2 699 60-/2 537 26-/4 667 59-/4 505 CX34-43C-6F C33-43C 27-/2 699 60-/2 537 25-3/4 654 58-3/4 492 - - - C33-44C 24-/2 622 57-/2 46 2-/2 546 54-/2 384 CX34-44/48B-6F C33-48B 24-/2 622 57-/2 46 22-/8 562 55-/8 400 CX34-44/48C-6F C33-48C 24-/2 622 57-/2 46 2-/2 546 54-/2 384 CX34-49C-6F C33-49C 29-/2 749 62-/2 588 28-/2 724 6-/2 562 CX34-50/60C-6F C33-50/60C 27-/2 699 60-/2 537 24-3/4 629 57-3/4 467 CX34-60D-6F C33-60D 25-/2 648 58-/2 486 24-3/4 629 57-3/4 467 CX34-62C-6F C33-62C 3-/2 800 64-/2 638 30-5/8 778 63-5/8 66 CX34-62D-6F C33-62D 29-/2 749 62-/2 588 28-3/4 730 6-3/4 568 B 33 (838) HORIZONTL POSITION Model Number B in. mm in. mm CH33-8-2F 2-/2 546 54-/2 384 CH33-24/30-2F CH33-36-2F CH33-36B-2F CH33-36C-2F CH33-44/48B-2F CH33-50/60C-2F CH33-42B-2F CH33-48C-2F CH33-60D-2F 26-/2 673 59-/2 5 CH33-62D-2F 3-/2 800 64-/2 638 ML80UHE / Page 2

BLOWER DT ML80UH045E36 PERFORMNCE (Less Filter) External Static Pressure in. w.g. ir Volume / Watts at Various Blower Speeds High Medium-High Medium Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 380 265 55 65 995 20 975 5 945 05 0.0 345 270 20 75 950 20 880 05 865 00 0.20 320 285 080 90 900 25 805 05 700 85 0.30 290 295 055 200 875 35 750 0 640 90 0.40 265 30 00 205 825 45 70 20 595 95 0.50 230 35 990 25 790 55 660 25 535 00 0.60 90 330 945 230 750 65 630 35 500 0 0.70 65 340 95 235 705 70 570 40 435 5 0.80 30 350 880 245 670 80 535 50 380 20 ML80UH070E36B PERFORMNCE (Less Filter) External Static Pressure in. w.g. ir Volume / Watts at Various Blower Speeds High Medium-High Medium Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 45 265 330 70 25 35 75 25 075 85 0.0 45 280 295 70 45 45 30 30 955 95 0.20 355 290 225 85 0 50 080 40 885 00 0.30 330 300 90 200 060 60 035 55 825 0 0.40 290 30 55 205 05 75 970 60 770 20 0.50 245 325 5 25 980 80 930 70 695 25 0.60 225 335 045 230 920 90 865 80 625 35 0.70 90 350 000 235 855 205 790 90 540 40 0.80 60 365 925 245 790 205 735 200 445 45 ML80UH090E48B PERFORMNCE (Less Filter) External Static Pressure in. w.g. ir Volume / Watts at Various Blower Speeds High Medium-High Medium Medium-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 785 380 570 270 440 220 395 90 90 20 0.0 755 395 535 275 420 230 350 205 40 30 0.20 730 45 505 290 380 245 30 25 0 45 0.30 690 435 460 305 345 260 275 230 065 55 0.40 645 440 435 320 30 270 240 240 00 65 0.50 65 455 395 335 265 285 80 255 955 80 0.60 590 470 350 350 20 290 50 265 95 85 0.70 545 475 300 360 75 305 095 275 860 200 0.80 N/ N/ 270 370 40 30 040 285 820 20 ML80UHE / Page 3

BLOWER DT ML80UH090E60C PERFORMNCE (Less Filter) ir Volume / Watts at Different Blower Speeds Bottom Return ir, Side Return ir with Optional Return ir Base, Return ir from Both Sides or Return ir from Bottom and One Side. External Static Pressure in. w.g. Single Side Return ir ir volumes in bold require field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2255 640 940 420 750 30 580 230 485 85 2290 655 980 425 775 30 605 235 495 95 0.0 2200 655 90 440 705 35 535 240 385 90 2250 675 945 445 730 320 555 245 400 90 0.20 250 675 865 450 655 340 490 260 340 205 220 695 885 465 680 340 50 265 350 205 0.30 225 695 835 475 635 355 450 275 285 25 265 75 850 475 645 355 470 275 285 25 0.40 2090 75 800 495 585 370 405 285 235 230 235 720 80 490 595 370 40 290 225 230 0.50 2060 735 760 50 545 385 370 305 200 245 2070 735 765 55 545 390 370 305 80 245 0.60 2020 750 725 525 55 405 320 320 45 255 2030 760 75 530 495 405 325 320 40 255 0.70 980 765 680 540 465 420 265 330 05 270 990 775 685 540 450 425 265 330 095 270 0.80 935 785 635 560 420 435 225 350 055 285 950 795 645 560 45 435 225 345 040 285 ML80UH0E60C PERFORMNCE (Less Filter) ir Volume / Watts at Different Blower Speeds Bottom Return ir, Side Return ir with Optional Return ir Base, Return ir from Both Sides or Return ir from Bottom and One Side. External Static Pressure in. w.g. Single Side Return ir ir volumes in bold require field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2230 635 945 430 75 295 555 230 470 85 235 645 990 45 780 300 60 230 50 200 0.0 280 655 905 445 690 305 50 240 340 75 2260 655 945 425 740 35 550 240 400 85 0.20 235 680 865 465 630 330 470 260 280 90 220 680 895 450 680 335 50 255 350 200 0.30 2090 695 830 480 595 345 440 275 235 200 265 700 850 465 650 355 455 275 285 20 0.40 2050 75 785 495 550 360 385 285 75 20 230 75 830 485 585 365 395 285 230 225 0.50 2025 730 740 520 500 375 340 300 30 225 2095 730 770 500 535 385 365 300 75 235 0.60 200 750 70 535 470 390 305 320 080 240 2055 755 725 55 495 400 305 35 35 250 0.70 965 755 670 555 420 40 255 330 05 255 2000 765 675 535 465 40 255 325 080 265 0.80 905 785 635 560 380 425 25 350 975 270 965 785 640 555 400 425 20 345 025 275 ML80UH35E60D PERFORMNCE (Less Filter) ir Volume / Watts at Different Blower Speeds Bottom Return ir, Side Return ir with Optional Return ir Base, Return ir from Both Sides or Return ir from Bottom and One Side. External Static Pressure in. w.g. Single Side Return ir ir volumes in bold require field fabricated transition to accommodate 20 x 25 x in. air filter in order to maintain proper air velocity. High Med-High Medium Med-Low Low High Med-High Medium Med-Low Low cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts cfm Watts 0.00 2495 755 2295 590 2045 435 845 35 650 230 2365 725 2295 575 2005 40 820 300 635 235 0.0 2440 780 2220 620 205 445 820 330 65 245 2350 745 220 595 2000 435 745 320 530 230 0.20 2390 790 275 640 935 470 735 350 550 255 2330 775 275 625 945 455 730 330 490 250 0.30 2360 805 240 655 895 490 720 370 485 275 2245 785 235 645 895 475 655 355 425 265 0.40 2285 835 225 675 850 50 660 380 455 290 225 80 2085 660 840 495 600 375 385 285 0.50 2240 860 2060 690 85 535 60 400 45 30 275 825 2045 680 85 505 590 390 340 290 0.60 2225 865 205 75 785 550 535 420 330 320 225 845 995 700 765 530 525 405 300 30 0.70 260 895 955 735 755 570 500 440 265 340 2095 865 950 70 700 545 485 420 260 325 0.80 205 905 925 750 75 580 435 450 25 345 2065 880 890 725 680 565 45 445 205 345 ML80UHE / Page 4

REVISIONS Sections Heating System Optional ccessories Description of Change Removed secondary limit dded Universal Service Kit - Switches Updated Night Service Kit Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 202 Lennox Industries, Inc.