Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics

Similar documents
High Throughput Large Area Silicon Drift Detectors

XGLAB. X and Gamma Ray Electronics. Looking for new frontiers...

First results and developments of the multi-cell SDD for Elettra and SESAME XAFS beam lines

High Performance Silicon Drift Detectors

SILICON DRIFT DETECTORS

Today s Outline - September 12, C. Segre (IIT) PHYS Fall 2016 September 12, / 21

Status Report about the TPC Detector and Module at CEPC

Silicon Detectors Passivated Implanted Planar Silicon (PIPS ) Detectors for Industrial Applications and Physics Research OEM VAR

GAMMA RAY DETECTION PROBE MODEL SO16

TRULY HAND-HELD gamma-ray detectors with excellent

North American Technical Services

Performance of a New Type of Electrical Cooler for HPGe Detector Systems

dewar or an electrically powered cooler. The sensitive detector surfaces are thus protected from moisture and condensable contaminants.

ORTEC DSPEC LF. High-Performance Digital Signal Processor for Gamma Spectroscopy. ... in a compact package at an economical price.

Radiation Safety issues for the PF-AR in KEK

ADVANCED SILICON DETECTORS FOR ELECTRON IMAGING & COUNTING

Unattended Radiation Sensor Systems for Remote Terrestrial Applications and Nuclear Nonproliferation

W.E.T. (Water Extraction Techniques) Lab

XPIN -XT X-ray Detector Operation Manual

Commissioning of the Silicon Drift Detector of the ALICE experiment at the LHC

LARGE VOLUME HEMISPHERICAL NUCLEAR RADIATION DETECTOR CZT/500(S)

DSP EC Pro. Advanced, Digital Gamma-Ray Spectrometer for HPGe Detector Systems

Temperature dependent Components within the Pyroelectric Detector

The first applications of novel gaseous detectors for UV visualization. I. Rodionov 4, O. Zanette 1. CERN, Geneva, Switzerland

Application of gaseous detectors for full-field EDXRF imaging of works of art

IAEA-SM-367/14/01 UTILIZATION OF FLUORESCENT URANIUM X-RAYS AS VERIFICATION TOOL FOR IRRADIATED CANDU FUEL BUNDLES

MOXTEK MULTI-LAYER OPTICS AND X-RAY TECHNOLOGY

Single-sided CZT strip detectors

The LHCb Outer Tracker: Production & Ageing studies

California, Berkeley, CA ABSTRACT 1. INTRODUCTION

APPROVED by U.S. EPA As a Class III Equivalent Method Designation for the measurement of PM 2.5

A GEM-based detector for detection and imaging sparks and flames G. Volpe 1 and V. Peskov 2. Abstract

LCLS Instruments. Jerry Hastings June 20, 2008 LCLS

Mapping the metal uptake in plants from Jasper Ridge Biological Preserve using synchrotron micro-focused X-ray fluorescence spectroscopy

PIXEL DETECTOR COLLABORATION MEETING

IFIN-HH, Hadron Physics Department infrastructure for ALICE TPC upgrade

Aging measurements on triple-gem detectors operated with CF 4 based gas mixtures

Influence of New Technologies on Technical Reachback

arxiv: v1 [physics.ins-det] 10 May 2017

Injection with front ends open at the ESRF

ANALYSIS OF OTDR MEASUREMENT DATA WITH WAVELET TRANSFORM. Hüseyin ACAR *

Automatic Detection of Defects on Radiant Heaters Based on Infrared Radiation

Range Dependent Turbulence Characterization by Co-operating Coherent Doppler Lidar with Direct Detection Lidar

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Technical Manual Ionisation Chamber MUSIC80

Technical Specification PILATUS 100K Detector System

Urethral alarm probe for permanent prostate implants

Low-Power Detectors. Key Features. 818 Series. Power levels from pw to 2W. Wavelengths from 190 nm to 1800 nm. Proprietary detector optics

GEM detectors activity at the Laboratori Nazionali di Frascati of INFN

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Spectrum Detector, Inc.

CZT/NaI Hybrid Hand-Held Performance Evaluation

Instrumental technique (MCP detectors) - Kamalesh ( )

Tracking Detectors 2 silicon for HEP

Aging Analysis of Micromegas Detectors for ATLAS New Small Wheel

Status of Texas active target data manager development. S. Ahn, G.V. Rogachev, E. Koshchiy, J. Hooker, and S. Upadhiajula

CERTIFICATE of Product Conformity (QAL1 )

IR15TT-R Miniature Infrared Gas Sensor for Monitoring Carbon Dioxide and Methane up to 100% Vol.

818 Series. Low-Power Detectors ABSOLUTE SPECTRAL RESPONSIVITY (A/W)

arxiv: v1 [physics.ins-det] 2 Oct 2013

MODEL-BASED OPTIMIZATION OF AN INFRARED GAS SENSOR

Infrared Carbon Dioxide Sensor Module CM1107-Dual Beam

Optical Time-Domain Reflectometry for the Transport Spatial Filter on the OMEGA Extended Performance Laser

SILICON SENSOR ACTIVITIES AT SINTEF MINALAB. Marco Povoli, Angela Kok, Ozhan Koybasi

Pressed pellets. Liquids, Slurries. Loose powders, Rocks, Granules. Metal cuts, Solids. Fused beads. Small parts. Coatings, Foils

Maintenance and Operation for ECAL Monitoring (WBS4.3)

The new generation Teledyne NIR detectors for the SNAP/JDEM mission spectrograph.

Measurement system for detection of Radon in building

Certificate: _02 / 22 March 2013

DEVELOPMENT OF LARGE AREA PLASTIC SCINTILLATION DETECTOR FOR RADIOACTIVE CONTAMINATION MONITOR

Gaseous detectors. 1

Title: Semiconductor detectors with proximity signal

Building and Characterizing 14GHz InGaAs Fiber Coupled Photodiodes

A Novel VLSI Based Pipelined Radix-4 Single-Path Delay Commutator (R4SDC) FFT

TECHNICAL NOTE JULY Dr. Thomas Butcher Brookhaven National Laboratory Building 526, P.O. Box 5000 Upton, L. I. NY 11719

Recent Advances in Large Area Micro-channel Plates and LAPPD TM

Minimizing radiation and beam losses at the ESRF

GERDA Phase II Detectors and Acceptance Tests

IntegraTorr Sputtered Non-Evaporable Getter. We support your innovation

Radiation Safety issues for the PF-AR in KEK

Ultraviolet radiation detector to obtain the rate of particles at different heights

Optical Time Domain Reflectometry (OTDR)

Optical Return Loss Measurement by Gregory Lietaert, Product Manager

MC-PAD FP7 Marie Curie Initial Training Network on Particle Detectors. Christian J. Schmidt, 4 th NoRHDia Workshop

Mission 份有限公司 wwwom 先锋科技股份有限公司 www Working with our customers we identify, design and deliver low light detection solutions which solve customer probl

Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter

Compact Raman spectrometer system for low frequency spectroscopy

FPI Detectors Pyroelectric Detectors with Spectrometer Functionality

February 12, PHY357 Lecture 11. Experimental Methods. Accelerators. Particle Interactions. Particle Detectors. Full experiment (eg.

Portable Survey Instruments NISP-RP-01

A CONCEPT FOR CANCELLING THE LEAKAGE FIELD INSIDE THE STORED BEAM CHAMBER OF A SEPTUM MAGNET*

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Diamond Windows & MCP Detectors for Synchrotron Applications

XP95 ENGINEERING PRODUCT GUIDE

Recent Advances in Mercuric Iodide Detector Fabrication and Instrument Development*

Investigation report. Radiation resistance of fire detectors under the influence of radioactive gamma radiation

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

High Speed Large Format Photon Counting Microchannel Plate Imaging Sensors

COMPACT RADIOACTIVE AEROSOL MONITORING DEVICE FOR EARLY WARNING NETWORKS

L0 TRIGGER ELECTRONICS FOR THE SETUP IN RUN MARCH 2017

Transcription:

"Science Stays True Here" Biological and Chemical Research, Volume 2015, 338-344 Science Signpost Publishing Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics S. Barkan *, V.D. Saveliev, Y. Wang, L. Feng, E.V. Damron, Y. Tomimatsu Hitachi High-Technologies Science America, Inc. 19865 Nordhoff St., Northridge, CA 91324, USA. Received: August 15, 2015 / Accepted: September 12, 2015 / Published: November 25, 2015 Abstract: Extremely High Count-Rate Performance of Silicon Drift Detector (SDD), the Vortex, has been achieved by integrating it with new front-end ASIC electronics and using a new pulse processing technology. The use of ASIC electronics produced a very low input capacitance that also significantly improved resolution at short peakingtimes. 1. Short Risetime The Vortex SDD system [1, 2] has been modified by replacing the standard JFET input electronics with an ASIC (CUBE), developed by XGLab S.R.L., Milan, Italy, and by use of new pulse processing technologies: the Xspress3 developed by Quantum Detectors, Harwell Oxford, UK, and the FalconX developed by XIALLC, Hayward, CA, USA. With the new ASIC technology a very short signal rise time is achieved, further enhancing the existing high countrate capability of the Vortex system. The output signal from the ASIC preamplifier is a step wave with its height proportional to the energy of the incident photon (~1.5 mv per 1 kev photon energy), as shown in Fig. 1. A Vortex ASIC unit was evaluated and compared with a similar unit equipped with a JFET by Dr. Cédric Cohen [3] at the European Synchrotron Radiation Facility (ESRF). An average rise time of 22 ns was observed as shown by the signal rise time distribution in Fig. 2. Corresponding author: S. Barkan, Hitachi High-Technologies Science America, Inc. E-mail: shaul.barkan@hitachi-hitec-science.us.

Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics 339 Fig. 1. 55 Fe oscilloscope trace of preamplifier output step pulses, including noise. Height of the steps is proportional to the x-ray energy (5.9 kev). Average signal rise time is 22 ns. Fig. 2. Vortex ASIC rise time (10-90%) histogram, collected at ESRF (35000 accumulated trigers). The Cube data was collected from the Vortex with Cube ASIC electronics. The other data (Old and Old collimated) are data collected from a Vortex with JFET electronics. 2. Vortex SDD and DPP The Vortex ASIC SDD was evaluated with the two most advanced digital pulse processors (DPPs): the

340 Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics Xspress3 from Quantum Detectors and the FalconX, a product of XIA. The count rate results with the Xspress3 are presented in Fig. 3. With the Xspress3, an output count rate of 1.6 Mcps at 2 Mcps input count rate (20% DT) was achieved as presented in Fig. 3. The peak position stability of the Vortex with the Xspress3 from zero to 3 Mcps is presented in Fig. 4. Fig. 3. The Vortex SDD count rate performance with the Xspress3. Fig. 4. Mn Kα peak position vs. OCR with Xspress3. The count rate results with the FalconX are presented in Fig. 5. With the FalconX an output count rate of 1.8 Mcps at 3 Mcps input count rate (40% DT) was achieved as presented in Fig. 5. The peak position stability of the Vortex with the FalconX from zero to 3 Mcps is presented in Fig. 6. With both advanced

Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics 341 processors, the Xspress3 and the FalconX, an energy resolution of less than 200 ev was achieved with a 2 Mcps input count rate. At low count rates, the SDD resolution is 130 ev. Fig. 5. The Vortex SDD count rate performance with the FalconX. Fig. 6. Mn Kα peak position vs. OCR with FalconX. 3. Implementing Asic into Multi-Element Detectors For some synchrotron applications, a single SDD unit is not adaquate to meet the high count rate requirement. To significantly improve the high count rate performance of the Vortex single SDD, a multi-element 4-channel SDD [4], the Vortex ME-4, equiped with ASIC electronics, was developed and is already in use

342 Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics in many synchrotron facilities throughout the world. The Vortex ASIC ME-4 is shown in Fig. 7. Several different multi-channel Vortex SDDs were developed for specific synchrotron applications. All of them are equipped with the ASIC electronics described above. One of these unique designs, which is already in use at the Brookhaven National Laboratory (BNL), is the Vortex ME-3 [4], which is a focal design detector with a narrow tube to enable close access to a sample in a limited chamber space. The special design enables the collection of a spectrum with maximum efficiency from a sample located at the focal point. The Vortex ASIC ME-3 is shown in Fig. 8. Fig. 7. The Vortex ME-4, containing four 50 mm 2 SDDs, for synchrotron high count rate applications Fig. 8. The Vortex ME-3, three 50 mm 2 SDDs, focal design: focal point at 30 mm.

Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics 343 A close look of the Vortex ASIC ME-3 s front end is shown in Fig. 9. The Advantage of the ME-3 focal design is presented in Fig. 10. Fig. 9. The Vortex ME-3 front end 4. Conclusions Fig. 10. The Vortex ME-3, focal design for a sample at 30 mm from the SDD s front surface The following parameters of the detector were tested at ESRF: rise time, peak shift, energy resolution, and efficiency. The results of the tests comply with the technical specifications of the Vortex datasheet. The ASIC preamplifier rise time duration is ~20% shorter compared to the previous preamplifier version, and offers the possibility of working at 100 ns processor peaking time without energy resolution degradation. The advanced digital processors Xspress3 and FalconX enable customers to collect data at the extreme count rate of 3 Mcps with minimal shifts of peak position and minimal loss of resolution. The multi-element Vortex ME-4 and ME-3 are products which directly address synchrotron high count-rate experiments by improved efficiency, resolution, peak position stability, and reliability.

344 Extreme High Count Rate Performance with a Silicon Drift Detector and ASIC Electronics References [1]. S. Barkan, J.S. Iwanczyk, B.E. Patt, L. Feng, C.R. Tull and G. Vilkelis, VortexTM A new high performance silicon drift detector for XRD and XRF Applications. Advances in X-Ray Analysis, vol. 46, 2003, pp. 332-337. [2]. J. S. Iwanczyk, B.E. Patt, C.R. Tull, J.D. Segal, C.J. Kenney, J. Bradley, B. Hedman, and K.O. Hodgson, Large area silicon drift detectors for X-Rays- new results, IEEE Trans. Nucl. Sci., vol. 46, pp. 284-288, June 1999. [3]. C. Cohen, ESRF Report: Test of CUBE Vortex-60EX-1mm-CUBE, June 2015, personal communication. [4]. V. D. Saveliev, L. Feng, S. Barkan, J. Wang, E. V. Damron, Vortex SDD Spectrometers with Improved Counting Rate Performance, 2015 APS/CNM Users Meeting.