Fire and Gas Mapping- Updates to ISA84 TR7

Similar documents
AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

AVOID CATASTROPHIC SITUATIONS: EXPERT FIRE AND GAS CONSULTANCY OPTIMIZES SAFETY

Fire and Gas Detection and Mitigation Systems

Gas Detection in Process Industry The Practical Approach

Using CFD to Analyze Gas Detector Placement in Process Facilities

Applying Functional Safety Engineering Technique to Optimize Defensive Fire Protection Strategy

International Journal of Advance Engineering and Research Development

MSA Flame & Gas Mapping

Session Number: 3 SIL-Rated Fire (& Gas) Safety Functions Fact or Fiction?

Martin Huber 26September 2017 F&G SOLUTIONS FOR THE PROCESS INDUSTRY

Failure Rate Data, Safety System Modeling Concepts, and Fire & Gas Systems Moderator: Lori Dearman, Webinar Producer Thursday, May 16th, 2013

FUNCTIONAL SAFETY IN FIRE PROTECTION SYSTEM E-BOOK

IEC61511 Standard Overview

IEC TC31 (Explosive Atmospheres) Gas Detection as Method of Protection Jon Miller

The Role of Engineering Judgement in Fire and Gas (F&G) Mapping

Explosion Protection Engineering Principles

Safety Instrumented Systems

Practical Methods for Process Safety Management

ADIPEC 2013 Technical Conference Manuscript

Environmental Management System Environmental Contingency Program

2015 Functional Safety Training & Workshops

ELC International Inc

Is your current safety system compliant to today's safety standard?

Alarm Management Reflections

By Dr. Maurice Stewart, PE, CSP Worldwide Petroleum Training

NFPA Changes

Safety Transmitter / Logic Solver Hybrids. Standards Certification Education & Training Publishing Conferences & Exhibits

Why AC800M High Integrity is used in Burner Management System Applications?

Presenter Joe Pittman

Alarm System Performance Metrics

Safety Instrumented Systems Overview and Awareness. Workbook and Study Guide

Integrating Fire and Gas Safety with Process Control Systems:

Laser-based gas detection technology and dispersion modeling used to eliminate false alarms and improve safety performance on Terra Nova FPSO

Case Study. INTEGRATING Fire & GAS SAFETY WITH PROCESS CONTROL SYSTEMS

FLACS-Risk Unique 3D risk modelling software. FLACS-Risk: Product presentation FLUG May 2016

Tank protection example using Simatic

Assessment of the Safety Integrity of Electrical Protection Systems in the Petrochemical Industry

NFPA 85 COMPLIANCES OF BMS: A CASE STUDY OF BOILER CONTROL AT SBM OFFSHORE MALAYSIA COMPANY 1. AHMED ABOUELRISH 2 Universiti Teknologi Petronas

Kenexis Software. Effigy. 3D Fire and Gas Mapping Software

Daily Offsite; 30 days of backup available; Offsite Annual backup maintained for 5 years

InstrumentationTools.com

Emergency shutdown systems. Procedures for bypassing ESD s

Protect your people, assets and environment while ensuring operational performance.

risk management and assessment for business Lessons Learned from Real World Application of Bow-tie Method 2010 International Symposium

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

TetraTek, Inc. Regulatory. Compliance. Emergency Response. Nuclear Facility Compliance. Compliance. Fire Protection.

FIRE PROTECTION PROGRAM

Options for Developing a Compliant PLC-based BMS

Use of Dispersion Modeling Software In Ammonia Refrigeration Facility Design. By: Martin L. Timm, PE Corporate Process Safety Manager

Optimization of gas detectors

Technical Paper. Functional Safety Update IEC Edition 2 Standards Update

PRIMATECH WHITE PAPER CHANGES IN THE SECOND EDITION OF IEC 61511: A PROCESS SAFETY PERSPECTIVE

2015 Honeywell Users Group Europe, Middle East and Africa

Statue of Liberty: A Risk Analysis

F&G detection system for LNG plants

Safety in the process industry

APPLICATION BULLETIN COMBUSTION TURBINE FACILITIES. Overview

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Session Four Functional safety: the next edition of IEC Mirek Generowicz Engineering Manager, I&E Systems Pty Ltd

Integrated but separate

INVESTIGATION FINDINGS III IMPACT OF INADEQUATE VENTILATION AND DISCHARGE SYSTEMS

Performance Based Gas Detection System Design For

Functional Safety: the Next Edition of IEC 61511

Managing the Lifecycle of Independent Protection Layers

UNIVERSITY OF ROCHESTER ENVIRONMENTAL HEALTH & SAFETY

Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program

innova-ve entrepreneurial global 1

Key Topics. Steven T. Maher, PE CSP. Using HAZOP/LOPA to Create an Effective Mechanical Integrity Program. David J. Childs

Chapter 17, Initiating Devices

ANALYSIS OF HUMAN FACTORS FOR PROCESS SAFETY: APPLICATION OF LOPA-HF TO A FIRED FURNACE. Paul Baybutt Primatech Inc. and

excellence in Dependable Automation ALARM MANAGEMENT

67 th Canadian Chemical Engineering Conference EDMONTON, AB OCTOBER 22-25, 2017

COSTCO, SAN FRANCISCO A PRESCRIPTIVE AND PERFORMANCE BASED ANALYSIS OF FIRE PROTECTION SYSTEMS AND DESIGN

Evaluation on Combustion Characteristics of Finishing Materials for Exterior Walls

Bowties in process safety auditing

First Revision No. 158-NFPA [ Global Input ] Submitter Information Verification. Committee Statement

Li-ion Tamer Improved monitoring for lithium-ion battery health & safety. SUPDET ESS Design Challenge November 30 th, 2018

New requirements for IEC best practice compliance

Safety Considerations for Hydrogen Installations

FIRE HAZARD ASSESSMENT IN SUPPORTING FIRE PROTECTION SYSTEM DESIGN OF A CHEMICAL PROCESS FACILITY ABSTRACT

GAS DETECTOR LOCATION. Ø.Strøm and J.R. Bakke, GexCon AS, Norway

Branch Fire Rescue Services

rpsa FIRE PROTECTION ENGINEERS

Soot Mitigation Strategies

Today's Topics & Sustainability Themes

Addressing Challenges in HIPPS Design and Implementation

Bowties in process safety auditing

Conducting a NFPA 652 Dust Hazard Analysis (DHA): Practical Tips & Approaches

RIM SEAL SYSTEMS E-BOOK

ICHEME SYMPOSIUM SERIES NO. 144 A METHODOLOGY FOR ASSESSING AND MINIMISING THE RISKS ASSOCIATED WITH FIREWATER RUN-OFF ON OLDER MANUFACTURING PLANTS

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Fuel and Energy Research Forum

Process Safety - Market Requirements. V.P.Raman Mott MacDonald Pvt. Ltd.

SAFETY MANUAL. PointWatch Eclipse Infrared Hydrocarbon Gas Detector Safety Certified Model PIRECL

National Fire Protection Association 1 Batterymarch Park Quincy, MA USA

Saving lives with coatings

SPRINKLER PROTECTION OF COMBUSTIBLE CONCEALLED SPACES WITH LESS THAN 6 BETWEEN OPPOSITE FACES IN CAVITY.

Where Technology Shapes Solutions. Alarm management : Wasn t that problem already solved years ago?

Sustain.Ability. Alarm Management: Be Pro-active, not Re-active Honeywell Users Group Europe, Middle East and Africa. Tyron Vardy, Honeywell

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

Transcription:

Fire and Gas Mapping- Updates to ISA84 TR7 Murtaza I. Gandhi, P.E. BakerRisk BAKER ENGINEERING AND RISK CONSULTANTS, INC. 2017 Baker Engineering and Risk Consultants, Inc.

Agenda Introduction to Fire and Gas (F&G) mapping Updates to ISA84 TR7 Example for fire detector analysis Discussion on coverage types Case Study discussion Summary

Introduction to F&G mapping FGS(Fire and Gas system) is a detection and a shutdown system based on fire and gas detectors detecting a fire or a gas/toxic release Employed widespread across the process and other industries FGS often documented as safeguards for fire/gas/toxic releases FGS often intertwined with SIS (esp. in O&G service)

Why should you be interested? Your recommendations drive the sites to add more fire and gas detectors. If you know and understand the methods to do mapping, you can provide better and more detailed recommendations for your clients/sites Understand the changes that are coming in the fire and gas mapping arena can help you educate your clients/sites better and reduce insurance risks further

What is TR84.00.07? Guidance on the Evaluation of Fire, Combustible Gas and Toxic Gas System Effectiveness Also called ISA 84 Technical Report 7 Written by members of ISA 84 committee Released in January 2010, new version about to be released (in ballot right now) Non-normative Provides guidance for those implementing a performance-based FGS 5

General Concepts of TR7 Establishes a flexible lifecycle approach similar to ISA 84 SIS lifecycle Describes performance-based (PB) approaches to FGS design Provides multiple example applications Doesn t restrict traditional prescriptive FGS approaches (NFPA 72, EN 54-2.) 6

FGS Lifecycle 7

Fire Detection Philosophy Goal is to detect fire as early as practical in order to reduce the possibility of escalation, minimize impact the asset, and allow personnel to take appropriate protective actions. Successful Mitigation Alarm and Notification Evacuation Isolation of fuel source Depressurize the process Initiate fixed fire suppression Shutdown ventilation

Gas Detection Philosophy Goal is to detect credible gas releases by strategically placing detection equipment in proximity to release sources in order to minimize potential for extended duration gas release that could result in severe consequences. Successful Mitigation Alarm to evacuate personnel Automatic or operator actuated ESD Isolate fuel source and depressure De-energize electrical sources Shelter-In-Place for toxic releases

Key TR7 Definitions FGS Effectiveness = FGS Detector Coverage x FGS Availability x FGS Mitigation Effectiveness FGS Detector Coverage Geographic coverage/ Scenario coverage FGS Availability 1- Probability of Failure on Demand(PFD) FGS Mitigation Effectiveness Probability of successful hazard mitigation by 10 FGS

Performance Based FGS Detector Coverage FGS Safety Availability FGS Mitigation Effectiveness Relative Likelihood Outcome Yes 0.9 0.76 Mitigated Yes 0.99 0.85 0.1 0.08 Unmitigated Design Basis Hazard No 1 0.01 0.01 Unmitigated No 0.15 0.15 Unmitigated FGS Effectiveness 0.76

Performance Based Performance targets for FGS Detector Coverage should be quantified for all applications where any risk reduction is claimed Wherever FGS target RRF exceeds 10, FGS Safety Availability should be quantified. Wherever FGS target RRF exceeds 10, FGS Mitigation Action Effectiveness should be quantified.

Updates to ISA84 TR7 ISA84 TR7 UPDATES

2010 vs 2017 version Current (2010 version) Covers detection Development of Safety Life Cycle (SLC) Defining F&G functions Examples of performance based system Upcoming (2017 version) Covers detection and mitigation Design associated with SLC Same as 2010 Same as 2010 Coverage or effectiveness <10% = RRF<10 Adds to prescriptive method Mitigation effectiveness

Examples provided in ISA84 TR7 Annexes in the TR provide examples for fire, flammable gas and toxic detectors Current presentation to focus on one example for fire detection in the well bay

Example description Offshore oil and gas production platform Rectangular area with length of 65ft Module contains 16 wellhead assemblies

Analyzing hazard and frequency Consequence Leak from wellhead with possible jet fire Wellhead material is at 1500 psig, 100F Possible loss of $10MM Consequence adjusted with pressure (3.5) Likelihood Base likelihood of leakage (2) Adjusted likelihood based on occupancy and probability of ignition (-0.5)

Unmitigated Risk Hazard rank Grade B Required fire detection coverage = 80% Adjusted Hazard Rank Grade Fire Detection Coverage >=7 A* > 0.90 5 to <7 A 0.90 2 to <5 B 0.80 0.5 to < 2 C 0.60 <0.5 N/A No Target Coverage

Initial Design Detector 1 Detector 2

Results Detector coverage (atleast 2 detectors detect) is 24% With 2 additional detectors, coverage increased to 82%

Mitigation Effectiveness Design intent is to detect incipient fire (50 kw) and Initiate wellhead shut-in Verified by calculations of the shutdown action reliability Open deluge valves Firewater analysis performed to verify adequate supply available Adequate deluge coverage provided Start fire water pump Verified by testing periodically

Example overall summary With 4 detectors, coverage for atleast 2 detectors (2ooN) is 82%, which is higher than the target of 80% Mitigation is effective and can prevent escalation

Types of Coverage COVERAGE TYPES

Definitions (ISA84 TR7) Geographic Coverage : The fraction of the geometric area or volume of a defined monitored process area that, if a hazard were to occur in a given geographic location, would be detected considering the defined voting arrangement In other words: % of area covered Scenario Coverage : The fraction of the hazard scenarios from process equipment within a defined and monitored process area that can be detected considering the frequency and magnitude of the hazard scenarios and the defined voting arrangement In other words : % of scenarios detected

Advantages Pros/Cons of Geographic Coverage Easy to understand graphical representation of results Easily repeatable and auditable detection layout Better for smaller releases Disadvantages Doesn t account for gas migration and ignition Number of detectors required are very high Higher lifecycle cost and possible nuisance alarms/trips

Pros of Scenario Coverage Advantages Based on gas cloud and migration Limited detector requirement Can be designed for risk Most favorable for Insurance Risk perspective Reduces nuisance trips Covers area of higher risk with more detectors Quantitative approach allows for calculations in savings through reduced incidents vs lifecycle cost

Challenges with scenario coverage Depends on the number of scenarios defined What are the right number of scenarios? How to consider the different elevations? In how many directions you need to rotate the release? Depends on the fluctuations in the plume concentration Is there enough time for the sensor to detect? Models are mostly steady-state Most models don t consider transients The transient models available mostly do not explicitly model the depressurization of a complex system Models for cross-wind and up-wind are not precise Different detectors have different response times Response characteristic impacts if detection is successful Impacts the speed of the response

Case study for Scenario Coverage To answer some of the questions, we proposed to perform a series of tests Tests were performed with saturated propane for ½, ¾ and 1 releases in 5 different orientations Horizontal (predominant wind direction) West East Up Down 74 tests were performed ranging from 1 to 1.5 minutes 14 detectors were placed 60ft upto 200ft from the release point (3 different manufacturers)

Case Study Initial 5 tests were performed to calibrate the difference in response with and without weather baffles Next 5 tests were performed to calibrate detector response from different manufacturer detectors 3 detectors were placed very close to each other in the direction of the release Remaining 64 tests were conducted randomly to determine the response for various release sizes, orientation and weather conditions Tests were performed in late morning and afternoon, night and early morning to capture different wind conditions Weather data was recorded for the tests

Case study For this presentation, only ½ release will be considered. A total of 34 tests were conducted for ½ release Downwind tests : 8 Vertical (Up): 6 Crosswind (west): 5 Crosswind (east): 7 Vertical (Down) : 8 Detectors were not moved throughout these tests to ensure proper comparison All detectors were located at 1.5ft

Case study results Horizontal release downwind

Case study videos(horizontal downwind)

Case study - results Scenario coverage for 1oo1 detector is 59% Scenario coverage for 2oo2 detector is 32% Average time to alarm is 55-60s for detectors in the direction of the wind after the release has occurred None of the releases in the up or west direction get detected Concentrations read by different detectors placed side by side varied significantly Wide ranging fluctuations were observed in concentrations during the test duration Speed of rise and maximum concentrations varied significantly between detectors

Summary SUMMARY

Recap New ISA84 TR7 has significantly improved guidance on fire and gas mapping Emphasis on mitigation effectiveness has increased significantly More details and examples on how to design the fire and gas system Guidance on how to tie the prescriptive approach with performance based approach Provides help on reducing risk quantitatively and hence reduce the costs of gas release or a fire

Recap Have a discussion with your sites about which approach to use: Prescriptive Geographic Coverage Scenario Coverage All the approaches have their pros and cons, understand them and take the best approach to achieve optimal risk reduction A hybrid approach with all of the three methods might be the best way to move forward Placing the detectors correctly saves you the most $$

Questions? Contact Murtaza Gandhi mgandhi@ bakerrisk.com 281-822-3100 37