JFT Flight Machine Models JFT Flight Machine Options Project Item Quantity CSI Section 00 Approval Date Blower dryer Additional wash section Additional load module Additional unload module (8m) wash down hose - mounted Electrical connection with circuit breakers Dual point electrical connection Low profile doors Flanged feet Multiple conveyor peg choice Drain at load or unload end JFT Flight Machine Standard Features Uses 9. gallons (.9 liters) of water per hour with sanitizing hot water rinse All tanks and hoods constructed from durable stainless steel with a No. finish and heliarced welded Stainless steel frame, legs and feet Two tank rackless conveyor shall have a maximum capacity of,9 dishes per hour at a belt speed of 8. (. M) feet per minute. At.8 feet ( M) per minute capacity will be,8 dishes per hour Belt width of 9 ( mm) and a maximum clearance of (mm) throughout the machine Enclosure panels, hood and doors are stainless steel and double wall insulated to reduce heat dissipation, outside surface temperatures, and noise pollution Insulated access doors for removal, cleaning and servicing V-shape tank(s) design to increase visibility and accessibility for cleaning as well as insure complete tank draining Heated power rinse zone uses fresh rinse water a second time to provide pristine results A sequential digital temperature readout of each tank housed in the door of the electrical control panel. The readouts will constantly display the temperature of the pre-wash, wash, power rinse and final rinse in second intervals A ball valve in the drain line of each tank and interconnected to a common machine drain connection at the load end of the machine Each tank will be automatically filled and maintained by a water level float. Water will be automatically added to the machine when required Block manifold wash arms are easy to remove, clean, and replace with nonclogging convex wash arm jets Large, removable scrap screens Self draining stainlesssteel pumps, impellers, and housings are readily accessible and serviceable Conveyor belt drive operates at two speeds and is protected by an overload safety device and an automatic shut-down actuator Each door is equipped with a door safety switch to prevent it from running when the door(s) are open. www.jacksonwws.com If a door is opened during operation the switch will immediately shut down the machine Operator activated start-stop switches on both the load and unload ends and the control panel Removable insulated panels to enclose the unit down to the base frame on both the front and rear of the machine A single, built-in8 (mm) diameter indirect vent connection with a 0.9 hp exhaust fan mounted in a cleanable cross duct on the machine for condensate removal and indirect vent connection minimum wall clearance Service access from front of machine of 8
Steam '- " [mm] '-" [0mm] '- " [80mm] 0'-8" [0mm] 8 " [mm] Minimum (Optional to drain at load or unload end of the machine.) '-8" [mm] '- 8 " [mm] '- 8 " [9mm] 9" [9mm] 0" [mm] '- 8 " [8mm] '-0" [8mm] '- " [08mm] '- " [9mm] '- 8 " [8mm] "[mm] Minimum '- " [mm] '- " [0mm] '- " [mm] '-0 8 " [90mm] '- " [9mm] '- " [9mm] Control Cabinet Door Open ' [9mm] ' [9mm] '-" [0mm] 8'-" [9mm] DIRECTION OF OPERATION 9'-" [9mm] Doors In The Open Position '-" [8mm] Optional - Short Doors In The Open Position '-" [8mm] 0" [mm] 8 8 " [mm] PREWASH WASH POWER RINSE 8 CONTROL CABINET ' [9mm] '- " [mm] '-0" [08mm] Top of Condensate Duct Pan 9'-" [89mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] '-8" [mm] 0'-8" [0mm] '- " [8mm] 8 8 " [9mm] 0 " [mm] '- " [mm] '-" [0mm] '- " [mm] 8" [mm] I.D. Square '-0" [08mm] A.F.F. " [mm] Deep Condensate Exhaust Duct Minimum 8" Square (Cross Section Sq. In. Provided by HVAC Contractor Exhaust Requirements - 00 CFM Condensate duct to extended into duct pan. Condensate duct pan mounted on top of dishmachine electrical section. Legend - -/" NPT Machine Drain Connection (Floor drain - optional to either end) - Electrical Connection - See Table for Amp Draw - /" NPT Incoming Water Connection - -/" NPT Steam Connection - /" NPT Wash Section Condensate Return - /" NPT Power Rinse Section Condensate Return - /" NPT Booster Heater Condensate Return 8 - Condensate Connection - See Detail Note: The condensate removal system built into the dishmachine consists of a fan that will remove 00 CFM. A single condensate connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 00 CFM from the area. of 8 Visit us at www.jacksonmsc.com or call us at -888-800-
'- " [mm] '-" [0mm] '- " [mm] '- 8 " [8mm] 0" [mm] 9" [9mm] 8 '- " [80mm] 0'-8" [0mm] '-8" [mm] '- 8 " [mm] '- 8 " [9mm] '- 8 " [8mm] '- " [9mm] Control Cabinet Door Open '- " [9mm] '-0 8 " [90mm] '- " [0mm] '- " [mm] " [mm] Minimum 9 " [0mm] '- " [mm] '- " [9mm] '- " [08mm] '-0" [8mm] " [mm] Minimum '-" [0mm] ' [9mm] ' [9mm] 8'- 8 " [mm] DIRECTION OF OPERATION '-0" [08mm] Top Of Condensate Duct Pan '- " [mm] ' [9mm] 8 CONTROL CABINET POWER RINSE WASH PREWASH 8 8 " [mm] 0" [mm] '-" [8mm] '-" [8mm] Optional - Short Doors In The Open Position 9'-" [9mm] Door In The Open Position 9'-" [89mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] '- " [mm] 0 " [mm] 8 8 " [9mm] '-8" [mm] 0'-8" [0mm] '- " [8mm] '-" [0mm] '- " [mm] Jackson Rackless Conveyors Wash, Power Rinse & Final Rinse (8 - minimum length) Steam tank heat electrical requirements with booster 08V 0V 0V Wash 9. 9..9 Rinse...8 Pre-wash/Drive/Exhaust... Total...9 Jackson Rackless Conveyors Wash, Power Rinse & Final Rinse (8 - minimum length) Steam tank heat, booster and blower dryer electrical requirements 08V 0V 0V Wash 9. 9..9 Rinse...8 Pre-wash/Drive/Exhaust 8..9. Total.0..9 Visit us at www.jacksonmsc.com or call us at -888-800- of 8
Load Pre-wash Tank Wash Tank Power R A start/stop switch is located at the load end of the machine for the operators convenience Load platform is gauge stainless steel. Machine Dimensions Load 8-/ (9 mm) Shipping Dimensions Load / Unload (Shipped Together) 8 (9 mm) Weight: lbs / 8 kg ( mm) The pre-wash tank features a stainless steel manifold system with stricturefree jets to optimize pressure for soil removal and to provide easy access for removal and cleaning. A.0 hp, RPM motor and pump is horizontally mounted. The pump housing is stainless steel and selfdraining. A stainless steel strainer with a removable basket is included. The pre-wash tank is a sloped design to ensure complete tank draining and to minimize soil build-up. Pre-wash Tank (8 MM) (8 MM) Pre-wash Tank 9 (00 mm) 8 (9 mm Weight: lbs / 9 kg ( mm) The wash tank features a stainless steel manifold system with stricturefree jets to optimize pressure for soil removal and to provide easy access for removal and cleaning. A.0 hp RPM motor and pump is horizontally mounted. The pump housing is stainless steel and selfdraining. A stainless steel strainer pan is included. The wash tank is a sloped design to ensure complete tank draining and to minimize soil build-up. Wash Tank (8 mm) (8 mm) Wash Tank 9 (00 mm) 8 (9 mm Weight: lbs / 9 kg ( mm) Stainless steel pow stricture free jets m below the wares a for cleaning. A.0 hp, R stainless steel ho are included. Po sloped design to tank draining an build-up Power Rin Height Dep (8 mm) (8 Power Rin Height De 9 (00 mm) ( Weight: of 8
inse Tank Final Rinse Blower Dryer Unload er rinse arms with ounted above and re easily removable PM motor with a using and impeller wer rinse tank is a ensure complete d to minimize soil Stainless steel rinse arms with jets mounted above and below the wares are easily removable for cleaning. The final rinse water will cascade back to the power rinse, wash and then the pre-wash tanks. A stainless steel tunnel incorporated into the discharge section of the machine. The blower dryer keeps the operating personnel from removing the wares before it reaches the end of the unload section. An industrial fantype with a squirrel cage driven by a 0. hp direct drive motor dries the wares as it exits the machine. *The Blower Dryer is an option and must be specifed at time of order. A start/stop switch is located at the unload end of the machine for the operators convenience. Unload platform is gauge stainless steel. The drive wheel shaft is supported by two heavy-duty grease-lubricated ball bearings in pillow blocks. se Tank th Length mm) Final Rinse 8 (08 mm) (8mm) Blower Dryer 88 ( mm) 8-/ (9 mm) Unload 8-/ (9 mm) (0 mm) se Tank pth Length 8 9 mm ( mm) Final Rinse 88 ( mm) 8 (9 mm ( mm) Blower Dryer 9 ( mm) 8 (9 mm ( mm) Unload / Load Shipped with load end lbs / 8 kg Weight: lbs / 88 kg Weight: 0 lbs / 9 kg of 8
Electric '- " [mm] '- 8 " [8mm] '-" [8mm] '- 8 " [mm] '- 8 " [mm] 9 " [mm] 9" [9mm] '- 8 " [8mm] '-0" [8mm] '- " [08mm] '- " [9mm] '- " [mm] " [mm] Minimum '- " [0mm] '- " [mm] '- " [9mm] " [mm] Minimum '- " [9mm] Control Cabinet Door Open ' [9mm] '-" [0mm] 8'-" [9mm] DIRECTION OF OPERATION Power Connections Inside Control Panel 9'-" [9mm] Doors In The Open Postion '-" [8mm] Optional - Short Doors In The Open Position '-" [8mm] 8 8 " [mm] '- " [mm] '-0" [08mm] Top of Exhaust Fan Housing 9'-" [89mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] '-" [8mm] '- " [mm] 8 " [9mm] TYPICAL 0 " [mm] 8" [mm] I.D. Square '-0" [08mm] A.F.F. " [mm] Deep Condensate Exhaust Duct Minimum 8" Square (Cross Section Sq. In.) Provided by HVAC Contractor Exhaust Requirements - 00 CFM Condensate duct to extended into duct pan. Condensate duct pan mounted on top of dishmachine electrical section. Legend - -/" NPT Machine Drain Connection (Floor drain - optional to either end) - *Wash Tank Electrical Connection - *Rinse Tank Electrical Connection - *Booster Heater Electrical Connection - *Motor Controls Electrical Connection - /" NPT Incoming Water Connection - Condensate Connection - See Detail *See Table For Amp Draw Note: The condensate removal system built into the dishmachine consists of a fan that will remove 00 CFM. A single condensate connection must be provided by the installing contractor. This is an indirect connection that must be capable of removing 00 CFM from the area. of 8 Visit us at www.jacksonmsc.com or call us at -888-800-
'- " [mm] '- 8 " [8mm] 9" [9mm] '- " [mm] '-" [8mm] '- 8 " [mm] '- 8 " [mm] '- 8 " [8mm] '- " [9mm] Control Cabinet Door Open '- " [9mm] '- " [0mm] " [mm] Minimum (Optional to drain at load or 9 " [mm] '- " [mm] '- " [9mm] '- " [08mm] '-0" [8mm] " [mm] Minimum unload end of the machine.) '-" [0mm] ' [9mm] 8'-" [9mm] DIRECTION OF OPERATION Power Connections Inside Control Panel '-0" [08mm] Top of Exhaust Fan Housing '- " [mm] '-" [8mm] '-" [8mm] Optional - Short Doors In The Open Position 9'-" [9mm] Doors In The Open Position 9'-" [89mm] Maximum Ceiling Height for Short Doors - '-0" [88mm] 0 " [mm] 8 " [9mm] Typical '-" [8mm] 8 8 " [mm] '- " [mm] Jackson Rackless Conveyors Wash, Power Rinse & Final Rinse (8 - minimum length) Electric requirements with booster KW 08V 0V 0V Wash. 9.9.0 Rinse.8 0.8. Motors and Controls... Booster 00.0 8.0.0 Total..0 8. Jackson Rackless Conveyors Wash, Power Rinse & Final Rinse (8 - minimum length) Electric requirements with booster and blower dryer KW 08V 0V 0V Wash. 9.9.0 Rinse.8 0.8. Blower Dryer, Motors and Controls 0.. 0. Booster 00.0 8.0.0 Total 9.8.. Visit us at www.jacksonmsc.com or call us at -888-800- of 8
JFT Flight Machine ELECTRICAL An electromechanical control system for increased reliability mounted in a stainlesssteel control cabinet on the front of the machine. A step-down transformer is included to provide volt, 0 cycles, phase operation for controls including selenoid valves, timers, etc. Wiring is 0C, 00-volt thermoplastic insulated wire and routed through UL approved conduit. Low watt density tubular heating elements are mounted inside the wash and power rinse tanks and are easily removable from the exterior of the unit. Heaters are protected by a water level float switch control and a high limit overload. Tank water temperature is maintained by a fast reacting thermostat which will control the heating element. STEAM Stainless steel tubular steam coils mounted inside the wash and power rinse tanks below the optimum water level and protected by a water level float switch control. An external Y strainer and high temperature steam solenoid to regulate the flow of steam through the coil. Tank temperature is controlled and maintained by a fast reacting thermostat that will control the operation of the steam solenoid. A float and thermostatic steam trap to remove the condensate from the coil are included. Steam coils will require a-0 PSI flowing steam pressure. BOOSTER HEATERS - ELECTRIC An internally mounted kw electric booster heater sized to raise incoming 0 F ( C) water supply to 80 F (8 C) minimum for sanitizing rinse. The electric booster heater will have the capacity to heat GPH from 0 F ( C) to 80 F(8 C) minimum. The tank is designed for a working pressure 0 PSI and hydrostatically tested at 00 PSI. The heater is complete with all plumbing, including NPT pipe and fittings from inlet and outlet. Electric heating elements are metal sheathed controlled by a close tolerance immersion thermostat. The booster is protected with a high temperature limit switch and low water cut-off. BOOSTER HEATERS - STEAM An internally mounted steam booster heater sized to raise incoming 0 F ( C) water supply to 80 F (8 C) minimum for sanitizing rinse. The steam booster heater will have the capacity to heat GPH from 0 F ( C) to80 F (8 C) minimum. The tank is designed for a working pressure 0 PSI and hydrostatically tested at 00 PSI. The heater is complete with all plumbing, including NPT pipe and fittings necessary to meet all installation requirements. The booster is protected with a high temperature limit switch and low water cut-off. DIMENSION REQUIREMENTS Wall Clearance (Minimum) Inside Clearance (9 mm) H x 0 W ( mmx mm) STEAM REQUIREMENTS Steam Flow Pressure (PSIG) 0-0 Consumption @0 F Incoming Water Temp (Tanks only) 90 lbm/hr Consumption @0 F Incoming Water Temp (0 F Rise Booster) lbm/hr OPERATING CAPACITY Consumption with blower dryer lbm/hr Dishes per Hour - Belt Speed.8 FPM (.0 MFM),8 Dishes per Hour - Belt Speed 8. FPM (. MFM),9 OPERATING TEMPERATURES Pre-Wash (Recommended) 0 F (0 C) Wash (Minimum) F ( C) Rinse (Minimum) F ( C) Final Rinse 80 F (8 C) MOTORS Pre-Wash Pump Motor.0 hp Wash Pump Motor.0 hp Power Rinse Pump Motor.0 hp Conveyor Drive Motor / hp HOW TO SPECIFY: JFT Flight Machine WATER REQUIREMENTS Inlet Tempterature 0 F ( C) Gallons per Hour 9. gal (.9 L) Waterline Size IPS (Minimum-inches) / (9 mm) Drainline Size IPS (Minimum-Inches) ( mm) Flow Pressure (PSI) - TANK CAPACITY Pre-Wash Tank gal ( L) Wash Tank gal ( L) Power Rinse Tank gal ( L) PUMP CAPACITY Pre-Wash Pump 0 gal (98 L) Wash Pump 0 gal (98 L) Power Rinse Pump 0 gal (8 L) 8 of 8 Jackson WWS, Inc. Shipping Address: 09 North U.S. Highway E, Gray, KY 0 Mailing Address: P.O. Box 00, Barbourville, KY 090 Telephone: 888-800- Fax: 0--99 Email: info@jacksonwws.com 00-00-8- [0/0/8] www.jacksonwws.com We reserve the right to change specifications in this bulletin without incurring any obligation for equipment previously or subsequently sold.