VHP M100 Biodecontamination Systems

Similar documents
VHP M100 Biodecontamination Systems: Closed Loop

VHP ARD Mobile Biodecontamination System

VHP M100 BIODECONTAMINATION SYSTEM

VHP ARD BIODECONTAMINATION SYSTEM

The Reliance 400/500 Glassware Washers

AMSCO V-PRO MAX LOW TEMPERATURE STERILIZATION SYSTEM (For Use Outside U.S.A. Only)

Introducing The Reliance 200 and 250 Glassware Washing Systems.

Open the Door to Increased Productivity and Cost Efficiency

Control Operating Costs. Gain Process Efficiency.

Technical Data Monograph. The Instrument Protection Properties of Prolystica Enzymatic Presoak and Cleaner and other Enzymatic Products

Prolystica Ultra Concentrate Instrument Cleaning Chemistries Now less is more. NEW generation instrument cleaners

Lower Your Costs. Expand Your Flexibility.

AMSCO STERILIZATION CONTAINER SYSTEM User s Guide

Application Equipment

Lower Your Costs. Expand Your Flexibility.

Instrument Cleaning Chemistries Automated Washing Process

V-PRO LOW TEMPERATURE STERILIZATION SYSTEMS

BARRIER TECHNOLOGY RABS & ISOLATORS FOR ASEPTIC PROCESSING

RELIANCE 580 PHARMACEUTICAL GRADE WASHER

RELIANCE 400 LABORATORY GLASSWARE WASHER

BASIL 6700 TUNNEL CAGE WASHER

RELIANCE 680PG PHARMACEUTICAL GRADE WASHER

LAB DIVISION. WASHING & DRYING cglp Process Equipment for Research and Microbiological Laboratories

An overview of sterilizer equipment standards current and planned. Richard Bancroft Science & Technical Director STERIS

STERIS Instrument Cleaning Chemistries

Flexible endoscope automated reprocessing system Safe and user friendly solutions for clinics

VACUUM FOR HIGHER QUALITY. In plastic injection molding

RELIANCE VISION SINGLE-CHAMBER WASHER/DISINFECTOR

VS LD series vertical steam sterilizers

Matachana Low Temperature Steam and Formaldehyde 130 LF Sterilizer

VACUUM FOR HIGHER QUALITY. In plastic injection molding

Introduction. Duncan Hogg Energy Market Manager (507) :50 p.m.

Corning LSE 6L Digital Water Bath

VS L range Laboratory Steam Sterilizers

cgmp STEAM STERILIZERS

Fedegari Aseptic Technology Integration: Case Study. Sergio Mauri, Director, Global Integrated Projects

PL 70 - PL 130 low temperature H 2

Aseptic Barrier Systems

The Logistics of Filling and Freeze Drying using Multiple Isolators. The use of isolator technology to fill and lyophilize pharmaceuticals

Certificate of constancy of performance,

Compact machine for automatic infeed, filling, and closing of injection vials.

OptiVenn TM Series INDUSTRIAL UV SYSTEMS. High performance, cost-effective system for stringent Industrial applications

PyroMega. Dry Heat Depyrogenising Ovens

BLUE GALAXY DEPYROGENATION TUNNELS. Solid Dose Sol

Achieving Functional Safety with Global Resources and Market Reach

Cleaning and sterilization solutions

ASM 340. Best in class leak detector for high reliability testing in various applications, using helium and hydrogen

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Environmental Chambers. 2-Door & 3-Door Extra Large Capacity

edwardsvacuum.com VACUUM PUMPS EOSi ROTARY SCREW PUMP

Pharmaceutical washing systems

Operation Manual Part-No

Pharmaceutical washing-systems

NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet

Environmental Chambers

When reliability is vital. Alemite Carbon Shield TM Systems deliver

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

SHAKING WATER BATHS ENGLISH

IBC Wash: Critical Cleaning Solution for IBCs, Totes and Tablet Bins.

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

SULLAIR DESICCANT DRYERS

HARMONY LED385 EXAMINATION LIGHTING SYSTEM

Ultra low temperature freezers -40 C and -86 C. NEXUS Series

Instrument Processing. Midmark Animal Health Products

PNEUDRI High Efficiency Compressed Air Dryers

TLS-300 UST Monitoring and Leak Detection System

CelCulture. Cradle for Beautiful Cells. CelCulture Water-Jacketed CO 2 Incubator

AUTOMATIC STERILIZERS

AMSCO CENTURY MEDIUM STEAM STERILIZER 26 X 26" (SCIENTIFIC)

Benchtop CO 2 Incubator. the Oasis 6400 series

The DECON RTP canister VHP decontamination system

Agilent 81663A DFB Laser 8165xA Fabry-Perot Lasers

Dual Tower Heat Reactivated Desiccant Air Dryer

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

CUTMASTER. Superior Quality Economical Flexibility Increased Productivity Easy To Use. Automated Plasma Cutting Systems

Easy to use, initiate test with the push of a button No additional tools required Provides visual alert to abnormal power conditions

MYLAB ERGONOMIC LABORATORY EQUIPMENT

ELISA NIMBUS. Automated ELISA Processing System

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

NEW GENERATION. Efficient use of valuable space INCUBATORS

BASIL 6000 TUNNEL CAGE WASHER

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Low Temperature Sterilisation ISO 14937

The Intelligent Choice for Rapid, Accurate Microwave Moisture/Solids Analysis. Innovators in Microwave Technology. Chemicals & Coatings.

Product Bulletin. VeriSafe Absence of Voltage Tester. The Safe Way to Verify the Absence of Voltage.

laboratory & sterilization technology

SteelcoSure Independent performance verification of your equipment and processes

AutoM Click to go to the page. AutoM Auto Shaker Filter

AQUAWING OZONE SYSTEM SPECIFICATION FOR PCI RETREAT LAUNDRY

M9 M /M3 11/ Automatic Sterilizers

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Controlled Environment Equipment Solutions for the Lab

Automatic Cyanoacrylate Fuming Chamber 24 33T 60T 72XL. Safely Detect Quality Latent Prints and Reproducible Results

CLARITY II TURBIDIMETER

Isolators, RABs and Mobile Clean Rooms in Aseptic Processing. Gary Partington Walker Barrier Systems

AZTECA A LITRE STERILISER

Corning LSE Digital Dry Bath Heater

STEAM STERILIZER SERIE S1000 (RBE)

V LPM Desiccant Air Dryer Installation and Operation Manual

HV-50 HVOF Thermal Spray System

Transcription:

LOW TEMPERATURE BIODECONTAMINATION* VHP M100 Biodecontamination Systems The proven technology of vaporized hydrogen peroxide biodecontamination for a variety of enclosures

Proven Technology in Two New Options Since the introduction of STERIS s vaporized hydrogen peroxide technology in 1991, VHP Biodecontamination Systems have become the predominant choice and industry standard for aseptic processing in research and production applications. With over 1400 VHP systems installed worldwide, STERIS now provides a product platform fulfilling both closed and open-loop** applications. Biodecontamination Applications Include: > Biological safety cabinets > Isolators > Glove boxes > CO 2 incubators > Pass-through chambers > Aseptic filling > Clean rooms > Material air locks VHP M100 Biodecontamination System > Modular unit can be conveniently integrated into isolator or biosafety cabinet > 304 Stainless steel enclosure wall and access door construction > Continuous Vaprox sterilant injection features available for open-loop applications > Easy access design for daily operation, service, and maintenance > Now available in mobile configuration for multiple-site biodecontamination applications requiring PLC features **Check local regulations regarding environmental hydrogen peroxide discharges.

Product Features/Options VHP M100 (closed-loop) Biodecontamination System VHP M100-X (open-loop) Biodecontamination System Style Mobile or Integrated Integrated - Convenient mounting capabilities for a wide variety of enclosures Control Options Allen-Bradley, Siemens, Mitsubishi Allen-Bradley, Siemens, Mitsubishi Printer Standard Standard Operator Interface Allen-Bradley - Panel View Plus 600 Siemens - TP277 Mitsubishi - GT 1155*** Vaprox Hydrogen Peroxide Cartridge Sterilant Container Interface Dehumidification System Reusable cartridges (regenerator accessory required) Disposal cartridges (adapter accessory required) Allen-Bradley - Panel View Plus 600 Siemens - TP277 Mitsubishi - GT 1155 Cartridge or Bulk Customer Supplied Desiccant Wheels Injection Rate 2-6 grams/minute 0.5-24 grams per minute Airflow 8-11 scfm (14-19 scmh) 8-44 cfm (14-75 scmh) Operating Temperature Range 68 F - 86 F (20 C - 30 C) Pressure Control +/- 1 in W.C. (250 pascal) N/A Industrial Designed Cabinet 304 SS enclosure wall and access door construction Weight 160 lbs. (72 kg) Dimensions WxHxD inches (cm) Power Requirements ***Integrated Applications Only 120 V, 50/60 Hz, 1 Ø, 20 A 200 V, 50/60 Hz, 1 Ø, 15 A 230 V, 50/60 Hz, 1 Ø, 10 A 31 x 26 x 9 (78.7 x 66 x 22.9) 200 V, 50/60 Hz, 1 Ø, 18 A 230 V, 50/60 Hz, 1 Ø, 15 A Control Features > PLC control permits interfacing with existing equipment > Preprogrammed or custom biodecontamination cycles > Cycle alarms for all cycle parameters > Security access code > Help screens > Language options: - VHP M100 Biodecontamination System - Siemens - English, German,French, Italian, Spanish, and Portuguese - Allen-Bradley - English, French - Mitsubishi - Japanese > Software documentation packages available > GAMP compliant > Battery backup protects cycle memory Ergonomically designed for maximum operator comfort and safety, the VHP M100-SP Biodecontamination System is easily maneuvered for multiple site use.

VHP 100 Reusable Desiccant Cartridge Regenerator > Industrial designed cabinet made of stainless steel > Weight: 105 lbs. (48 kg) > Dimensions: WxHxD 18.3 x 45.5 x 18.5 in (46.4 x 115.6 x 47.0 cm) > Power Requirements: 120 V, 50/60 Hz, single phase, 8 A or 200 V, 50/60 Hz, single phase, 4 A 230 V, 50/60 Hz, single phase, 4 A VHP 100 Reusable Desiccant Cartridge Regenerator Options To Fit Your Specific Application To dehumidify the enclosure, select from either a reusable or disposable desiccant system: VHP 100 Disposable Desiccant Cartridge Constructed of plastic, the disposable cartridge is lightweight and easy to install. A prompt notifies the operator when it is time to replace the cartridge. Regenerate one desiccant cartridge while operating with another for continuous use. Regenerator can be conveniently located to service multiple units. VHP 100 Reusable Desiccant Cartridge Constructed of aluminum, the reusable cartridge is easily installed and removed. A prompt notifies the operator when it is time to remove the cartridge and install it in the VHP 100 Reusable Desiccant Cartridge Regenerator. An indicator on the cartridge signals the user that the cartridge is ready for reuse.

Typical Biodecontamination Cycle More 100% VHP Concentration Relative Humidity Less Gas Concentration Relative Humidity Condensation Point Dehumidification Condition Biodecontamination Aeration 0% The VHP Biodecontamination cycle operates in a closed-loop configuration where the enclosure is subjected to four phases: > Dehumidification - Reduction of relative humidity to pre-determined level > Condition - Rapid increase to desired VHP concentration > Biodecontamination - Maintenance of desired VHP concentration and relative humidity (for retention of vapor phase) > Aeration - Rapid reduction of hydrogen peroxide vapor Advantages of VHP M100 Biodecontamination Systems > Biodecontamination under ambient conditions Cycle times vary with initial temperature and humidity, enclosure type, size and configuration, and load. The process is fully automated. All cycle parameters are monitored and recorded for process validation. How VHP Biodecontamination Works... > Proven efficacy against a wide range of microorganisms > Broad range of material compatibility, including metals, plastics and elastomers > Environmentally friendly process yielding only water and oxygen as by-products Vaprox Hydrogen 35% Peroxide Hydrogen Sterilant Peroxide Vaporization Vaporization Cold Biodecontamination Process 2H 2 O 2 2H 2 O2 2 4-80ºC 4-80 C Non-Toxic By-products Non-Toxic By-Products Sporicidal Sporicidal at Low at Low Concentrations (Typically (Typically 0.1-2 mg/l at at 25 C) 25º C) 2H 2O 2 O O 2 2

System Requirements > Dehumidification system desiccant cartridges; select either reusable or disposable. > Regenerator accessory for reusable desiccant cartridges. Regenerate one desiccant cartridge while operating with another for continuous operation. Only one regenerator accessory is required to service multiple machines and can be conveniently located. > Vaprox Hydrogen Peroxide Sterilant (EPA Registration No. 58779-4) formulated to provide optimum equipment performance. > VHP Chemical and Spordex Biological Indicators NOTE: The user is responsible for ensuring that enclosures are properly sealed before using any VHP Biodecontamination System. Training, Technical Support, and Service > Full operator training is provided either on-site or at a STERIS training facility. > Application Engineers are available to assist with onsite training, hands-on demonstrations, custom cycle development and validation training. > Field Service Engineers are available to assist with IQ/OQ/PQ, calibration, start-up, and preventive maintenance. Standards The unit and control systems have been designed to meet the applicable requirements of the following: > Underwriters Laboratories (UL) Standard 61010-1 > Canadian Standards Association (CSA) Standard C22.2 No. 61010.1 > EMC Directive: 89/336/EEC, 92/31/EEC, 93/68/EEC > Low Voltage Directive: 73/23/EEC, 93/68/EEC Spordex Biological Indicators (Bacillus stearothermophilus) and VHP Chemical Indicators are available for use in Vaporized Hydrogen Peroxide distribution, efficacy studies, and sterility testing. To minimize exposure to the liquid hydrogen peroxide during handling, the system uses specifically designed disposable cartridges (available separately) containing approximately 950 ml or bulk containers containing approximately 5 gallons (19L) of Vaprox 35% Hydrogen Peroxide (H 2 O 2 ) Sterilant. *When using VHP Biodecontamination Systems with Vaprox Hydrogen Peroxide Sterilant in the United States, the term biodecontamination referred to in this document is defined as sterilization of exposed porous and non-porous surfaces in a pre-cleaned, dry, sealed enclosure. Any reference to biodecontamination as it relates to the use of this equipment in the United States does not impart additional claims of effectiveness beyond that approved in the EPA-registered labeling of Vaprox Hydrogen Peroxide Sterilant. STERIS Corporation 5960 Heisley Road Mentor, OH 44060-1834 n USA 440-354-2600 n 800-444-9009 www.steris.com Manufactured exclusively by STERIS Corporation in our Mentor, Ohio facility, which is ISO 9001 certified. STERIS Offices Worldwide Benelux 32 2 523 2488 Brazil 5511 5053 9823 Canada 800 661 3937 China 86 21 6137 1166 France 33 0 2 38 70 83 50 Germany 49 2203 890 6969 Greece 30 210 6800848 Document # M2245EN.2008-8, Rev. F Italy 39 22 130341 Japan 81 78 321 2271 Latin America 800 884 9550 Nordic 358 9 25851 Singapore 65 68 41 7677 Spain 34 916 585 920 United Kingdom 44 1256 840400 2002-2008 STERIS Corporation. All rights reserved.