NZQA registered unit standard version 1 Page 1 of 5

Similar documents
NZQA registered unit standard version 4 Page 1 of 5

NZQA registered unit standard 5881 version 6 Page 1 of 5. Demonstrate knowledge of electronic security devices

NZQA registered unit standard version 1 Page 1 of 5

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate knowledge of electrical installations in special situations

NZQA registered unit standard 5897 version 3 Page 1 of 5. Design electronic security intruder alarm systems

NZQA registered unit standard version 2 Page 1 of 5. Use painting and decorating tools and equipment

NZQA registered unit standard version 1 Page 1 of 5. Install fixed gas detection apparatus in hazardous areas

NZQA registered unit standard version 1 Page 1 of 5. Demonstrate advanced knowledge of refrigerants and their management

National Certificate in Fire Detection and Alarm Systems (Testing) (Level 3) Level 3

National Certificate in Fire Detection and Alarm Systems (Level 4) Level 4

National Certificate in Passive Fire Protection (Routine Inspections) (Level 3) Level 3

NZQA unit standard version 1 Page 1 of 6. Install, maintain and repair of telecommunications optical fibre network infrastructure

NZQA unit standard version 2 Page 1 of 6. Perform installation and maintenance of telecommunications radio systems and services

National Certificate in Fire and Rescue Services (Vegetation) (Level 4)

National Certificate in Fire and Rescue Services Airport (Level 3)

National Certificate in Fire and Rescue Services (Vegetation) (Level 2)

National Certificate in Fire and Rescue Services (Vegetation) (Level 3)

NZQF NQ Ref 1266 Version 2 Page 1 of 13

This qualification has been reviewed. The last date to meet the requirements is 31 December 2018.

Operate portable pumps for fire fighting

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 1: General requirements. Australian/New Zealand Standard

NZQA Expiring unit standard 3397 version 4 Page 1 of 5. Convert an automotive air conditioning system from R-12 to R-134a

FIRST SCHEDULE GUIDELINES FOR MINIMUM QUALIFICATION AND EXPERIENCE REQUIRED FOR ACCEPTANCE OF INDEPENDENT QUALIFIED PERSONS STATUS

AS/NZS :2015. Conduit systems for cable management AS/NZS :2015. Part 21: Particular requirements Rigid conduit systems

Aon Sprinkler Certification Technical Note

Dear Customer. Section Old F8 January 2017 Amendment 4. Replace with new title page and document history pages 1 2B

EXPRESSION OF INTEREST (EOI) FOR. Fire Fighting System (FFS)

AS/NZS 3190:2011 AS/NZS

Subject Description Form

NZS 7901:2014. Electricity and gas industries Safety management systems for public safety NZS 7901:2014. New Zealand Standard

IE Code IE Competency Title Credit OAC Ref.

UEE30811 Q-Tracker Work Tasks

AS/NZS 4012:1999 AS/NZS

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

Independent Qualified Person (IQP) Registration Guidelines

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016. Part 3: Installation site

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM. Standards Training SANS 369 ORIGINATOR

RADIOCOMMUNICATIONS (EMC STANDARDS) NOTICE 2004 No. 2

Course outline: 311 Cable Selection G107A UEENEEG107A - Select wiring systems and cables for low voltage general electrical installations

AS/NZS 3133:2008 AS/NZS

AS/NZS :2014

AS/NZS IEC :2013

AS/NZS :2012. Regulatory compliance mark for electrical and electronic equipment AS/NZS :2012. Part 1: Use of the mark

NZQF NQ Ref 1014 Version 10 Page 1 of 20

Australian/New Zealand Standard

AS/NZS :2016

AS/NZS 3111:2009. Approval and test specification Miniature overcurrent circuitbreakers AS/NZS 3111:2009. Australian/New Zealand Standard

AS/NZS :2014

Qualification Specification. Fire Marshall I N G A W A R D S I N T R A S A F E T Y S R D S A F E T Y T A W A. Version

AS/NZS :2014. Electrical equipment for coal mines Introduction, inspection and maintenance AS/NZS :2014. Part 1: For hazardous areas

Australian/New Zealand Standard

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

IFE Level 4 Certificate in Fire Science and Fire Safety

Firefighting operations on fire alarm panels F5-04 GD

SEMPEO SQA Unit Code H02H 04 Wiring electrical equipment and circuits

Australian/New Zealand Standard

AS/NZS :2008

C-Bus Four Channel Analogue Output Unit Installation Instructions

XANDER INSERT WOOD BURNER

AS/NZS IEC :2015

GOLDFIELDS PRIMARY SCHOOL. TENDER SPECIFICATION For ELECTRICAL SERVICES MECHANICAL ENGINEER:

Australian/New Zealand Standard

Dear Customer. Please find attached the January 2017 amendments to C/AS4 Acceptable Solution for Buildings with. Innovation and Employment.

Australian/New Zealand Standard

AS/NZS :1998 AS/NZS ISO

SAQCC FIRE D&GS TRAINING SUB COMMITTEE COURSE CURRICULUM

Dear Customer. To update your printed copy of C/AS7, please make the following changes: Section Previous version January 2017 Amendment 4

Australian/New Zealand Standard

Information for persons seeking acceptance as Independent Qualified Persons (IQP)

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

BUILDING CODE ACCESS CONSULTING ESSENTIAL SERVICES

Level 3 Certificate in Fire Safety Fire Auditors Xact Consultancy and Training Limited

Bringing Hydrocarbon to the Market Training & Certification

VESDA VLP. Engineering Specification

Fire Protection, Inspection and Testing Qualifications Forums. Jeremy Rose (Artibus Innovation) Chris Wyborn (FPA Australia)

APPENDIX H (DESIGN SUBMISSION CRITERIA)

BUSINESS PLAN CEN/TC 121 WELDING AND ALLIED PROCESSES EXECUTIVE SUMMARY

QUALIFICATIONS AND CREDIT FRAMEWORK (QCF) LOGIC CERTIFICATION LIMITED (LCL) QUALIFICATION SPECIFICATION

AS/NZS :2016. Refrigerating systems and heat pumps Safety and environmental requirements AS/NZS :2016

INDEPENDENT QUALIFIED PERSON APPLICATION

Self-Containment Of Motor Caravans

IFE: Level 5 Diploma in Fire Engineering Design Xact Consultancy and Training Limited

AS/NZS 3120:2011. Approval and test specification Cord extension sockets AS/NZS 3120:2011. Australian/New Zealand Standard

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

50T Electric Shop Press

Level 3 NVQ Diplomas in Heating and Ventilating ( /31/32)

Building Consent Application Compliance Schedule Information

Air Conditioning for Industrial and Commercial Buildings

AS/NZS 3820:2009 (Incorporating Amendment 1) Essential safety requirements for electrical equipment

Compliance Schedule Handbook Prepared by the Ministry of Business, Innovation and Employment

100T Electric Shop Press

Substation Signage. Document Number: 1-11-FR-12

Australian/New Zealand Standard

Fire alarm provisions for alerting the Fire Service

INDEX INDEX 2 FOREWARD 3 SECTION 1 COMPANY INFORMATION 4 SECTION 2 GRADING AND CERTIFICATION 5 SECTION 3: ADDITIONAL REQUIREMENTS 6 7

Schedule of Accreditation

AS 1851:2012 The Use and Adoption of the New Standard The impacts and challenges for the fire protection and property management industries.

COOPER POWER SERIES. Types R, W, WV and RV reclosers, KA869R and KA835W series trip coils replacement instructions. Reclosers MN280020EN

Australian/New Zealand Standard

Standards of Training in Safe Gas Work Domestic Natural Gas Training Specification

Transcription:

Page 1 of 5 Title Demonstrate knowledge of fire detection and alarm system components and installation practices Level 3 Credits 9 Purpose This unit standard is for the training of fire alarm technicians, and covers the knowledge of fire detection and alarm system components, their principles of operation, installation practices, wiring and cabling principles, ducting and cable securing/supports, electrostatic discharge (ESD) and precautions. People credited with this unit standard are able to demonstrate knowledge of: principle of operation of major components of fire detection and alarm systems; component symbols and fire detection and alarm system drawings; cabling systems; fasteners commonly used in the installation of fire detection and alarm system components; fire alarm and detection system component and cable installation practices; and electrostatic discharge (ESD). Classification Mechanical Engineering > Fire Detection and Alarm Systems Available grade Achieved Explanatory notes 1 References Building Act 2004 Ministry of Business, Innovation and Employment (MBIE) Acceptable Solutions (AS) and Verification Methods (VM). Available at http://www.dbh.govt.nz/as/vmdocuments New Zealand Building Code AS/NZS 3000:2007, Electrical Installations (known as the Australian/New Zealand Wiring Rules) AS/NZS 3013:2005, Electrical Installations classification of the fire and mechanical performance of wiring system elements NZS 4512:2010, Fire Detection and Alarm Systems in Buildings SAA HB 20:1996, Graphical symbols for fire protection drawings. 2 Definitions Equipment specifications refer to manufacturer s specifications for installation, operation, and performance of their equipment. Fire detection and alarm system refers to an installation of apparatus, which performs specified fire related functions in response to the operation of a detector, manual call point, or other input. It includes manual call points, detectors, control and indication

Page 2 of 5 equipment, alerting devices, interconnections, fittings, labels, energy sources, and remote signalling devices and may include emergency warning and intercommunication systems (EWIS) where applicable. Industry practice refers to the safe and sound trade practice generally accepted by competent persons within the fire protection industry. Standards refer to NZS 4512:2010 and AS/NZS 3000:2007. 4 Assessment Knowledge of all systems defined by NZS 4512:2010 must be demonstrated. Outcomes and evidence requirements Outcome 1 Demonstrate knowledge of principle of operation of major components of fire detection and alarm systems. may include but is not limited to manual call points, alerting devices, detection devices, delay timers, isolation switches, control units, power supplies, remote signalling devices, input devices. 1.1 The purpose of each major component is described. 1.2 The principles of operation of the major components of fire detection and alarm systems are described. 1.3 The locations and positions of detectors and fire alarm panels are described in accordance with the standards. may include but is not limited to heat, point-type smoke, beamtype, line-type, aspirating, fire alarm panel. 1.4 The purpose of marking and labelling components, sub-assemblies, terminals, and controls is described. Outcome 2 Demonstrate knowledge of component symbols and fire detection and alarm system drawings. may include but is not limited to manual call points, alerting devices, detection devices, delay timers, isolation switches, control units, power supplies, remote signalling devices, input devices, fire alarm panels. 2.1 The drawing symbols of major components are identified. 2.2 Layout of fire detection and alarm systems, schematic diagrams, and interconnection drawings are interpreted.

Page 3 of 5 Outcome 3 Demonstrate knowledge of cabling systems. 3.1 Types of cables used in the fire detection and alarm systems and associated interfaces are described in terms of their type and uses in accordance with the standard and equipment specifications. 3.2 Types of cable support systems used in fire detection and alarm system installations and associated interfaces are described in accordance with equipment specifications and industry practice. typical support systems may include but are not limited to trunking, conduit, catenary wires, cable trays. 3.4 Cable termination methods are described in accordance with equipment specifications, industry practice and standards. Outcome 4 Demonstrate knowledge of fasteners commonly used in the installation of fire detection and alarm system components. fasteners may include but are not limited to screws and bolts including various types of heads and self-tapping screws; different types of nuts including locking nuts; plain, spring, and serrated washers; various types of pins including cotter pins; circlips; masonry anchors; adhesives. 4.1 Fasteners are visually identified from given physical samples or pictorial representations. 4.2 Uses of fasteners are outlined with reference to fire detection and alarm system installation/applications and equipment specifications. 4.3 The principles of bolted joints are outlined with reference to forces and locking mechanisms. Outcome 5 Demonstrate knowledge of fire alarm and detection system component and cable installation practices. 5.1 Installation practices for fire detection and alarm system components, cable support systems, and interfaces are described in accordance with equipment specifications, industry practice and standards.

Page 4 of 5 components may include but are not limited to control equipment including power supplies, detectors, manual call points, alerting devices, zone control and indicating units; cable support systems may include but are not limited to trunking, conduit, catenary wires, cable trays. Outcome 6 Demonstrate knowledge of electrostatic discharge (ESD). 6.1 ESD and causes of ESD are described. 6.2 The effects of ESD on electronic circuits and fire alarm control equipment are explained. 6.3 The precautions required and methods of prevention of ESD damage to fire alarm control equipment is described in accordance with industry practice. Planned review date 31 December 2020 Status information and last date for assessment for superseded versions Process Version Date Last Date for Assessment Registration 1 15 October 2015 N/A Consent and Moderation Requirements (CMR) reference 0013 This CMR can be accessed at http://www.nzqa.govt.nz/framework/search/index.do. Please note Providers must be granted consent to assess against standards (accredited) by NZQA, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment. Industry Training Organisations must be granted consent to assess against standards by NZQA before they can register credits from assessment against unit standards. Providers and Industry Training Organisations, which have been granted consent and which are assessing against unit standards must engage with the moderation system that applies to those standards. Requirements for consent to assess and an outline of the moderation system that applies to this standard are outlined in the Consent and Moderation Requirements (CMRs). The CMR also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements.

Page 5 of 5 Comments on this unit standard Please contact at qualifications@competenz.org.nz if you wish to suggest changes to the content of this unit standard.