FIREMASTER CONCERTINA TM

Similar documents
FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

FIRE & SMOKE CURTAINS

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

FIRE & SMOKE CURTAINS

PRODUCT SPECIFICATION FireMaster Plus Concertina

PRODUCT SPECIFICATION FireMaster Plus

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

PRODUCT SPECIFICATION FireMaster Concertina

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

CI/Sfb ( ) smoke stop. Smoke Barriers for all applications... Swiss Re London. Lane Crawford Singapore. London.

Technical Manual (European Standards)

A REVOLUTIONARY APPROACH TO FIRE SAFETY

Smoke and Fire Curtains

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

Firetex steel fire shutters

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

ACTIVE FIRE CURTAINS INTISI7

Operation & Maintenance Manual

The Passive Fire Protection Handbook

fire resistance testing

Evacuate everyone Sonos Pulse & Nexus Pulse

Perimeos. Ceiling Recess. decor. systems

The Passive Fire Protection Handbook

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Fire resistance. Appendix E. E.1 Fire resistance. Appendix. (A copy of this Appendix is available on /)

Fire Suppression Systems

Aspirating Smoke Detection for Large Area Coverage Applications

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

Hold-open magnets DORMA

BLE Smoke and Fire Curtains

Fixing points M6 (1/4 )

HART XL High Sensitivity Smoke Detection

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Altra Interior Shutters Altra Exterior Shutters SMRT Shutters Wood+Plus Shutters External Sun Screens Awnings and Canopies Roller Blinds Vertical

ESTATE COLLECTION POWER DRIVEN WINDOW TREATMENTS. solarshadingsystems.com 3000 Airway Avenue Front, Costa Mesa, CA /

FM MEDICOL. Cableflow International Limited. The FLUSH MEDICOL (FM) Patient Care Services. Column has evolved from a market requirement for a

Fire and Smoke Curtains

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

Hazardous Area Portable Fan Heater The Bulldog

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

MWS5. Miniature Microwave Presence Detector (standalone) Product Guide. Overview. Features

Loss Prevention Standard

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

The Downs Portsdown Hill Road Cosham

Distributed by ECO LIGHT PRODUCT OVERVIEW. Hazardous Area Luminaires

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

Hazardous Area Portable Fan Heater The Bulldog

IFE Level 3 Certificate in Passive Fire Protection

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

Window blinds and Soft furnishings for the Healthcare and Education markets

WALLCOVERING WOVENIMAGE.COM WOVEN IMAGE

IFE Level 3 Certificate in Passive Fire Protection

Direct Dim Microwave Presence/Absence Detector

SUNWARM AIR SOLAR PRE-HEAT VENTILATION SYSTEM

HunterDouglas Silhouette Shades are unique and extremely versatile window shades; soft as silk, elegant as a curtain and practical as a venetian

ALARM MATE NEWSLETTER SEPTEMBER 2013

HYBRID PLUS2 AIRCOOL VENTILATORS

Analogue Dimming Microwave Presence/Absence Detector

Avenue Metro. The evolution of an icon. UK Head Office Whitecroft Lighting Ltd Burlington Street Ashton-Under-Lyne Lancashire OL7 0AX

Dublin airport - Dublin, Ireland

IS-ORANGE Envirograf. Orange Book. Ventilation. T +44 (0) F +44 (0)

MWS3A-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

CI/SfB (57.7) 2nd edition. Lo-Carbon Quadra

HYBRID PLUS2 AIRCOOL VENTILATORS

SMOKE AND FIRE CURTAINS

Ceiling PIR HS presence detector 1-10V, low temperature. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. IR Receiver

THE LEADING EDGE IN Smoke & Fire Curtains

MWS6-PRM. Ceiling microwave presence/absence detector. Product Guide. Overview. Features

Allianz Engineering Inspection Services Ltd. Electrical Services. Product Information

FIRE ALARMS. IN DWELLINGS By John Ware FIRE ALARMS

Aspirating Detection System. Protec Aspirating Detection System Atria Design Guide. MED2199 Atria Design Guide Issue 0 Page 1 of 22

VISTA DESIGN. The iconic vitrine VISTA

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

S ILENT Series INSTALL SILENCE, INSTALL QUALITY OF LIFE. The Quietest Extractors in the World in their Category 26,5

SENSA MRE DDM MR

scorpion SMOKE TESTING FOR ASD SYSTEMS AND HARD-TO-ACCESS POINT DETECTORS IN ACADEMIA APPLICATIONS RESTRICTED AREA AUTHORISED ENTRY ONLY

Hazardous Area Portable Fan Heater The Bulldog

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

Transcription:

FIREMASTER CONCERTINA TM CONCERTINA TM THE INVISIBLE ACTIVE FIRE CURTAIN BARRIER ASSEMBLY WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION

DESIGN SOLUTIONS THAT WORK FOR YOU CASE STUDY: OIL SEARCH SYDNEY AUSTRALIA The revolutionary FireMaster Concertina provides the same protection as a steel fire shutter but at a fraction of the size and weight, with no need for columns, corner posts, side guides and intrusive ceiling interfaces, giving architects, consultants, specifiers and owner/occupiers a whole new way to approach building design, maximising floor space and increasing rental income. Active Fire Curtain Barrier Assemblies comprise technologically advanced fire-resistant fabric barriers encased in a compact steel housing. Barriers remain invisibly retracted until activated by an alarm or detector signal, at which time they descend safely to their operational position. OPEN SPACE - Virtual compartments with unlimited width for maximum design flexibility STAIRWELLS - No need for nonloadbearing fire-rated walls ESCALATORS - No need for non-loadbearing fire-rated walls LOBBIES - No need for nonloadbearing fire-rated walls and doors ATRIA - Allows multi-floor concourse openings for large atria Ensuring you remain protected from fire without compromising the intended architectual open plan design can be problematic, especially when you re protecting stairwells and atria. Such a situation led Oil Search Australia to employ Coopers Fire to develop and manufacture a unique circular 18-sided Concertina that ensures the office complies with stringent Building Code requirements whilst permitting an imposing and more efficient office space overlooking Sydney Harbour. To be compliant, Fire Barriers must be protected from a short circuit and or total power failure, this is achieved with our patented Total Gravity Fail-Safe (TGFS) system. The revolutionary Concertina design arrangement protects the open plan spiral staircase whilst removing the need for side guides and columns to provide the full fire rating. The end product provided a uniform look across all 3 levels, mirroring the spiral staircase opening. We have also installed L shaped and four/sided configuations of the Concertina into Selfridges, Oxford St and Bovis Lend Lease, London. BENEFITS Only one product/system is required to achieve the required fire rating. No side guides, no columns and no posts. A curved ceiling interface panel fits in with the look and feel of the building. No compromise on the fire performance. PRODUCT ADVANTAGES NO MORE COLUMNS AND CORNER POSTS With no visible support posts required, the Concertina offers open plan environments. NO MORE INTRUSIVE SIDE GUIDES No corner posts and columns mean that there is no longer the need for side guides to compromise design. NO MORE INTRUSIVE CEILING INTERFACES Our ceiling interfaces are designed to blend with your existing ceiling, resulting in a discrete and aesthetically pleasing finish. INCREASE FLOOR SPACE Free up space that s usually occupied by rated glass or non-loadbearing compartment walls. INCREASE INCOME Maximising floor space by opening up spaces will increase square meter yield and rental income. ANY SHAPE Every Concertina is bespoke and is manufactured to meet your specific requirements. TOTAL GRAVITY FAIL-SAFE (TGFS) operation ensures safe rates of descent even following total power loss, wiring, short circuit or system Interfaces with the zone smoke control system. Modular construction that s quick to install. No secondary steelwork required. Multi-functional operation. 2 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 3

BESPOKE PRODUCT CONFIGURATIONS STANDARD HEADBOX SIZES HOW ARE THE HEADBOXES INSTALLED? Developed to provide a bespoke alternative to fixed non-loadbearing walls, partitions and fire shutters, the Concertina can be used as part of a fire engineering solution in commercial and industrial applications such as airports, shopping centres, offices and hotels or where the need for maintaining open areas for access is vital. Coopers has a design solution for any size requirement. For queries about special size requirements, please contact our technical department. Model No. FM Concentina 45/22 350 100 Maximum Barrier Width Unlimited Maximum Barrier Drop Up to 8M There are many fixing options to suit all types of ceiling configurations. Barriers can be integrated with both solid and suspended ceilings, enabling total project design flexibility. 1. 225 Soffit 300 Headbox Section (motor on RH) Headbox Section (motor on LH) (Based on a 4m drop. Larger headboxes are available upon request.) 2. 3. Suspended with unistrut fit 4. 5. 1. Square (Closed) 2. Faceted Curve (Open) 3. L Shaped Corner (Open) 4. Trapezoid (Closed) 5. Multisided (Closed) Barriers up to 5m in height have been approved for 4 hours (240 mins) fire-resistance integrity. For barriers up to 8m high, are approved for 2 hours (120 mins). I beam 4 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 5

HOW ARE THE BARRIERS CONCEALED? We can provide a range of ceiling interfaces developed to conceal the barrier in the ceiling whilst still allowing access for service and maintenance. All our systems remain totally concealed when non-operational. With suspended ceilings, our unique patented Coopers system SLAT (Self Levelling Access Trim) can be utilised. Remember, regular service and maintenance is a legal mandatory requirement. ALTERNATIVE CEILING INTERFACE CONTROL OPTIONS Controls are custom made to be fully compatible with both existing alarm systems and the number of barrier units installed, whether single or multiple roller assemblies. When an alarm signal is detected, the control panel will automatically trigger all the Barrier systems to deploy by controlled descent using our unique Total Gravity Fail-Safe (TGFS) system. CONTROLS SPECIFICATION POWER SUPPLY 230V AC 50Hz dedicated supply via all pole isolator BATTERIES 2 x 12V 12A/h lead acid batteries ALARM SIGNAL Normally closed volt-free contacts. Open on activation TEST FACILITY Zone Control Panel (ZCP) located on front of Power Supply Unit () DISPLAY Power ON, ACTIVE and OFF status LED s on ZCP POWER SUPPLY SIZE 400mm(w) x 500mm(h) x 210mm(d) MOTOR CONTROL UNIT SIZE 300mm(w) x 200mm(h) x 80mm(d) Flush fit tray down Suspended ceiling with SLAT Suspended Ceiling WHAT IF I NEED SIDE CHANNELS With open shapes it s also possible to install the Concertina to work with traditional side retention systems whereby the barrier is fixed to the building and can be either surface mounted or recessed into the wall structure to give a flush finish. The diagrams to the right illustrate both Recessed and Face Fix options. Coopers unique fabric locking system has been developed and proven over many years. Recessed Fix Face Fix PRODUCT SPECIFICATION The complete system is assessed for 240 minutes (4 hrs) and 120 minutes (2hrs) in accordance with BS EN 1634-1:2008 and is classified as E180 EW60 C1 in accordance with BS EN 13501 2:2007+A1:2009. It also meets the requirement of BSI PAS 121:2007 (where applicable). The fabric is additionally tested for fire propagation to BS 476 6:1989+A1:2009 and surface spread of flame to BS 476-7:1997 to achieve National Class 0 in accordance with A13(b) of Approved Document B (Volumes 1 & 2) 2006 Edition Fire Safety to England & Wales Building Regulations 2000. EFP TM 4/1000 is a long established, high performance fire textile composite material of woven glass fibre with a high performance coating, containing a micronised aluminium enriched polymer, which when exposed to fire, is absorbed into the surface of the curtain to provide high temperature performance. This coating was developed and used first by Coopers Fire. DON T BE LIABLE Fire Curtain Barriers MUST have a Total Fail- Safe by Gravity* in the event of total mains, wiring, short circuit and/or system corruption. Coopers Fire, with their unique patented Total Gravity Fail-Safe (TGFS) system, are the only supplier with Independant Third Party Certification by a UKAS approved certification body to BSI PAS 121:2007 and now meets essential requirements of BS 8524-1:2013. FM 22356 CPD ACCREDITATIONS LQR 4007272 6 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 7

For information, to get a quote or to book a CPD workshop Please call: +44 (0)2392 454 405 or E-mail: info@coopersfire.com WWW.COOPERSFIRE.COM Coopers Fire Ltd, Edward House, Penner Road, Havant, Hampshire, PO9 1QZ United Kingdom Phone: +44 (0)2392 454 405 Fax: +44 (0)2392 492 732 Email: info@coopersfire.com Web: www.coopersfire.com Coopers Fire Ltd has a policy of continuous product improvement. As such we reserve the right to change design and specifications without prior notice. Please check our website for the latest information. Coopers Fire Ltd. All content and products are copyright of Coopers Fire Ltd. Registered in England Number: 2010274. *Multiple patents granted and pending. Series 2 v04 May 2015 8 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION