Ventilation in balance

Similar documents
CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

SEQUENCE OF OPERATIONS

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Fingertip control, optimum efficiency, total comfort and clear reporting. warmafloor.co.uk

CAREL heatersteam Electric Element Steam Humidifiers

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

FC330A-ECO Auto-addressing analogue 1-Loop fire detection panel

CONDAIR RS. Resistive steam humidifier With advanced scale management. Humidification and Evaporative Cooling

Master devices. Type X-AIR-ZMAS. Zone master module for up to 25 zone modules, with integral webserver and interfaces to higher-level systems

VENTILATION WITH HEAT RECOVERY

SAUTER EY-modulo 5. The complete building management solution

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

Sequence of operation

SAUTER EY-modulo 5. The complete building management solution.

FG Wilson Control Systems

DEMAND CONTROLLED HOME VENTILATION HCC 2 Designed to suspended ceiling installation

PRODUCT DATA COMFORT 300 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 325 m 3 /h

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

AL-KO CONTROL TECHNOLOGY THE SIMPLE ROUTE TO CONTROL

API MARINE BMS4 REMOTE SOUNDING SYSTEM FOR BALLAST AND SERVICE TANKS

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

Tried, true, and trusted for over 40 years. EL Series Electrode Steam Humidifier. Humidification and Evaporative Cooling. humidity.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

Complete Boiler Management in a Compact, Affordable System

NEW. Innovative heating controls. Commercial boiler control systems. Control 8000 & MX25

Product overview. Alarm indicator, operator and display panels

Air Handling Units. Systemair Access. Making you the air handling expert

SmartVFD HVAC and BYPASS

ICC INDUSTRIAL CONTROL COMMUNICATIONS, INC.

Demand Controlled Ventilation - With the windows shut! AHUs. For consistently good indoor air quality DATA LO GG ER. Scan to visit website

GMM Güntner Motor Management

CLIMATE SEPARATION SOLUTION. SensAir

WLM3 the 3 rd generation of the OJ Waterline TM Control Systems. Industry leading intelligence, control SLIDE OJ Electronics

AHUs. Direct, Zone-Specific, Demand Controlled Ventilation AWARDS VENTILATION PRODUCT. For consistently good indoor air quality WINNER 2012

ENERGY SAVING SEIBU GIKEN DST

Corrigo E. Second generation which contains all applications and languages

Tailored air movement control solutions

CLIMATE SEPARATION SOLUTION. SensAir

A Smart & Integrated Security solution

Different types of Fire Alarm System

NOZ2. Multi-Directional Heating & Cooling Solutions

ZXSe Range Data Sheet

COMPRESSOR SYSTEMS MADE IN GERMANY G-DRIVE & V-DRIVE SCREW COMPRESSORS

INSTALLATION AM ; AMC

Med Touch Master Alarm

SALES SUPPORT DOCUMENT

Typical Operating & Maintenance Manual for SOLA-BOOST X-Air Project Name

PRODUCT DATA VPL 15 TOP M2 BY NILAN. Ventilation & active heat recovery. Active heat recovery. Comfort heating. Comfort cooling.

FC330A-ECO1 Auto-addressing analogue 1-Loop fire detection panel

Ventilation in balance

SmartVFD HVAC and BYPASS

SLV CONTROLLER 105N46XX SERIES

NEWS THEBEN THEBEN 2

Control system. cabinet

Manual for the integration in BMS/GTC

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-35 GEBRAUCHSANWEISUNG DEUTSCH SEITE with external sensor

Electronic controllers. Comfort embellishes everyday life

Lyric T6 & T6R Smart Thermostat

Trident User s Manual

EasyLog Data Logger Series

In-store baking oven DILA

Process Alarm Solutions

EVF815 Installer manual ver. 2.0 Code 144F815E204 EVF815

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys Designed in Denmark

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Geniox. The next generation of air handling units

DAP III Zone Master User s Guide

Fridge-tag 2 OPERATION MANUAL ENGLISH PAGE 1-36 GEBRAUCHSANWEISUNG DEUTSCH SEITE with internal sensor

Advanced FireAlarm Panel 1-4Loop

PRODUCT DATA COMFORT 302 TOP BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 345 m 3 /h

Control System Structure

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

Products and systems

Fridge-tag 2 E OPERATION MANUAL ENGLISH PAGE 1-36 MODE D EMPLOI FRANCAIS PAGE with internal sensor

EasyLog Data Logger Series

ECL Comfort 310 controller, Remote Control Units ECA 30 / 31 and Application keys

NOXSYS A SYSTEM FOR THE HIGHEST LEVEL OF SECURITY

PRODUCT DATA COMFORT 1200 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 1400 m 3 /h

The full range of Evaporator Controls from ADAP-KOOL

Exercise 8. Controlling a Batch Mixing Process EXERCISE OBJECTIVE

ECL Comfort 210 controller, Remote Control Units ECA 30 / 31 and Application keys

Lift Station Level Controller

Tri-Tech Medical Inc.

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

EL-USB-1-LCD Temperature Data Logger with LCD

Document # R01

FlexLine. Air humidification for industry, commerce, culture and leisure. Steam humidifier. New flexibility in award-winning quality

grundfos SEG AUTOadapt The perfect grinder pump for wastewater transport be think innovate

ROTARY SCREW COMPRESSORS

Contents. 30 References

Operating Guide. ECL Comfort 210 / 296 / 310, application A247 / A Table of Contents

External insulated volume. control damper

Screw Compressors ESM Fixed Speed & VS Variable Speed

Specifications Minimum Typical Maximum Unit

The integral solution for. Air Handling Units. Technology & Evolution

Metal Detection. High Performance Metal Detection Delivering Efficiency and Reliability SAFELINE

120+ Get your job done swiftly Easy selection of your application is the key. applications.

Transcription:

Ventilation in balance control and operation Airlinq

IF 2013 The Airlinq AM L control panel has won two design awards at if 2013 for its innovative design one award for if product design and if communication design for the control panel user interface. perfect indoor climate with demand-controlled ventilation We view things differently. For some people, technology has to be smart and elegant for others, functionality and control is essential. At Airmaster, we believe that when it comes to demandcontrolled ventilation both are important. Quality, function and aesthetics are key at Airmaster. For this reason, Airmaster doesn't only focus on the air handling unit itself, but also on the control system and control panel. Airmaster's air handling units are controlled using an intelligent control system called Airlinq. Airlinq L control panel for: AM L 100 AM L 300 AM L 500 AM L 800 CV 80 CV 200 CONTENTS Perfect indoor climate 3 Reaching new heights with Airlinq 4 Airlinq L simple and discreet 6 Control functions Airlinq L 8 Airlinq P means full control every day 10 Control functions Airlinq P 12 Intuitive and simple operation The Airlinq control system is operated from intuitive and discreet control panels offering easy operation with their unique design and touch panel features. Feeling the full benefit All Airmaster air handling units are designed to achieve optimum performance. This is why Airmaster has developed a new control system and control panel, that enable users to Airmaster CTS and digital BMS 14 benefit 100% from the features of the air handling units. Connecting the units to a PC also ensures complete control of the Airlinq P control panel for: 2 various functions. AM P 300 AM P 900 AM P 500 AM P 1200 3 AM P 800 CV 1000

Reaching new heights with Airlinq With their wealth of control options, ventilation solutions from Airmaster give users full control of their indoor climate. Airmaster not only ensures a world-class indoor climate, but also verification and correct operation of the air handling unit. The Airlinq control system Data log A new and unique feature that logs all important operating data, e.g.: Inlet temperature Discharge temperature Outdoor temperature CO 2 levels Air humidity Airflow Airlinq PC Tools Option of monitoring and configuring units using a PC running the Airlinq User Tool. A more advanced tool is available for service engineers the Airlinq Service Tool. Advanced warning and alarm system The advanced warning and alarm system helps to minimise operating and service costs. Faults are detected more quickly, ensuring continued reliability of the air handling unit. BMS Flexibility with digital BMS Airlinq can be equipped with a network module (additional circuit board) which provides the option of flexible connection to a network system: KNX BACnet TM /IP BACnet TM MS/TP LON MODBUS RTU RS485 Downloading to a PC System operating data can be downloaded to a PC. This provides a quick overview of unit operation and enables the production of operational documentation. This ensures optimised operation of the air handling unit. 1 All-in-one All intelligent control is integrated in the control unit itself which means that air handling units are fully automatic removes the need for a control panel. CTS Airmaster CTS An Airmaster CTS enables up to 20 different and individually equipped air handling units to be controlled from a single control panel. The system offers much more than the usual Master- Slave system. Airmaster sensors for BMS Airmaster's motion sensor (PIR) and CO 2 sensors can be used in network systems. This provides simple and economical connection to the BMS system. 4 5

Airlinq L simple and discreet Operating functions Configuration of airflow using the front touch function. Activate holiday/absence mode to ensure basic ventilation with reduced airflow. Airlinq L has been designed with control and function in mind. It provides optimum day to day operation with minimal user intervention. Manual start, stop and sleep mode. Display warnings and alarms with a yellow or red symbol. It does not get any easier than this The operating functions on Airlinq L are simple. Operation is automatic and means that the risk of errors is minimised. Airlinq L is available for the following air handling units: AM L 100 CV 80 AM L 300 CV 200 AM L 500 AM L 800 Connecting a PC to the control panel's USB port allows changes to be made to the settings, monitor unit performance and view operational information. The PC requires the Airlinq User Tool programme which can be downloaded from www.airmaster.dk/airlinq Settings are always configured on a PC. Child lock Automatic operating lock Airlinq User Tool Set and monitor operation. Receive operating information. The control panel gives users the option of seamless Further programming can be done using the Airlinq operation of the air handling units using airflow is the Service Tool. This can be downloaded from www. Airlinq Service Tool main operational parameter. airmaster.dk/airlinq Programme controls. Download data logs. Download or upload control settings. Update control software. Automatic synchronisation of the builtin clock with the PC's date and time. 6 7

Control functions Data logging Continuous data logging of all important operating data. The data log can be set as a time-bound log. Logging frequency and operating data can be customised. The control unit is set to datalog every five minutes as standard the memory is sufficiently large to collect operating data for one year. When the memory is full, the oldest data is overwritten to ensure that the latest data are always accessible. The benefits of this include: - Option of readouts of very precise operating data, e.g. tracking error logs. - Option of generating operating reports for each unit. - Documentation of air quality by the connected CO 2 sensor. Sensors Demand-controlled airflow relative to air humidity using electronic humidity sensors for both outdoor and indoor air to ensure optimum room humidity levels. Demand-controlled airflow relative to CO 2 levels using a CO 2 sensor. Integrated 13.5 Volt sensor power supply. Two analogue inputs: - Inputs can also be used as digital inputs. - Inputs can be programmed as required. This means that the air handling unit is fully automatic and controlled using two dynamic sensors, two contact sensors or one dynamic sensor and one contact sensor. Heating surfaces Automatic control of heating surfaces. Electronic frost protection using preheating or afterheating surfaces and the Preheating or Virtual Preheating function. Control box Option of control of cooling module using an additional print. Network connection using additional prints of the type KNX, LON, MODBUS, BACnet TM MS/TP, BACnet TM /IP is available. All intelligent control is contained in the control box. This means that air handling units can also be run without the use of a control panel. The control panel is connected to a separate power point. No draughts or cold air Automatic bypass control to maintain inlet temperature. Control of motorised air dampers. Monitoring Filter monitoring using an hourmeter. Time intervals can be customised. Condensate monitoring using a float switch. Electronic monitoring of sensors and fans. Time controls Time-controlled operation with seven time programme options and a built-in clock. The airflow, inlet temperature, days and times can be programmed individually for each time programme option. Analogue BMS Option of analogue BMS control which manages operating times, airflow and inlet temperature. Night cooling Independent automatic night cooling. The programme can be customised as required. 8 9

Airlinq P full control every day Operating functions Easy and clear operation of Airmaster CTS. Configuration of all key operating parameters using an automatic start-up guide. Activate holiday/absence mode to ensure basic ventilation with reduced airflow. Configuration of airflow using the front touch function. Manual start, stop and sleep mode. For those users requiring greater control of the ventilation units, the Airlinq P provides the perfect solution. Display CO 2 levels with a connected CO 2 sensor (for all CO 2 sensors using Airmaster CTS). Display warnings and alarms with text descriptions (for all units using Airmaster CTS). Multiple options The operating functions provide many options for controlling the ventilation unit. With its touch functions, Airlinq P makes it easy to navigate and configure operating parameters. The menu structure makes operation easy and clear reducing the risk of errors. Airlinq P is available for the following air handling units: Airlinq PC Tools The USB port can be used to connect a PC running the Airlinq Service Tool. The software can be downloaded from www.airmaster.dk/airlinq Settings can be configured directly on the controller's touch screen. Manual start/stop of a single group or the whole system using Airmaster CTS. Configure operating parameters: Airlinq Service Tool AM P 300 AM P 900 Display operating status with up to 40 The control panel can easily connect to a PC AM P 500 AM P 1200 operating parameters. running the Airlinq Service Tool programme to Overview and configuration of all time access all operating data. AM P 800 CV 1000 programme options incl. night cooling. Set and programme controls Inlet temperature and standard airflow. Download data logs. Set date and time. Download or upload control settings. Reset service. Monitor energy use using a built-in energy Customise data log. meter. 10 Restart the start-up guide to configure all Update control software. 11 key operating parameters when customising Automatic synchronisation of the built-in an installation. clock with the PC's date and time. Automatic operating lock. Screen lock with security code.

Control functions Start-up guide An integrated start-up guide ensures quick and easy programming during installation of the air handling unit. The start-up guide is integrated into the settings menu and may be restarted at any time. Sensors Demand-controlled airflow relative to CO 2 levels using a CO 2 sensor. Integrated 12 and 24 Volt sensor power supply. Three analogue and three digital sensor inputs. - Analogue inputs can also be used as digital inputs. - Inputs can be programmed as required. This means that air handling units can be fully automated and controlled using several dynamic sensors and contact sensors. Night cooling Independent automatic night cooling. The programme can be customised as required. Data logging Continuous data logging of all important operating data. The data log can be set as a time-bound log. Logging frequency and operating data can be customised. The control unit is set to datalog every five minutes as standard the memory is sufficiently large to collect operating data for one year. When the memory is full, the oldest data is overwritten to ensure that the latest data are always accessible. The benefits of this include: - Option of readouts of very precise operating data, e.g. tracking error logs. - Option of generating operating reports for each unit. - Documentation of air quality by the connected CO 2 sensor. No draughts or cold air Automatic bypass control to maintain inlet temperature. Control of motorised air dampers. Heating surfaces Automatic control of pre-heating and after-heating surfaces. Frost protection using virtual pre-heating and after-heating surfaces or preheating with a preheating surface. Control box Monitoring Time controls Analogue BMS Integrated cooling module control. The control unit constantly monitors airflow to All time controls are gathered in a single Option of analogue BMS Network connection using additional prints of ensure that the whole system is always in balance menu and have the capacity to run in parallel. control which manages the type KNX, LON, MODBUS, BACnet TM irrespective of back pressure. This provides an overview of time-controlled operating times, airflow MS/TP, BACnet TM /IP is available. Electronic monitoring of sensors and fans. ventilation and night cooling as well as easy and inlet temperature. All intelligent control is contained in the Filter monitoring using an hourmeter and electronic and flexible setting of the time controls. control box. This means that air handling flow monitoring. Time intervals can be customised. Time-controlled ventilation with seven time units can also be run without the use of a Condensate monitoring using a float switch. programme options and a built-in clock. The control panel. Advanced warning and alarm system. This ensures airflow, inlet temperature, days and times 12 The control panel is connected to a separate that stoppages are detected quickly and ventilation can be programmed individually in each time 13 power point. thereby becomes more reliable. programme option. Alarm output for remote monitoring of the air handling unit.

AIRMASTER CTS...and digital BMS All air handling units from Airmaster can also be combined in an Airmaster CTS solution. If air handling units are required to be controlled and monitored centrally, a digital BMS solution can be used. Up to 20 units, which are grouped according to individual parameters, can be controlled from just a single control panel. Digital BMS has the capacity of integrating an unlimited number of individually controlled air handling units. The Airlinq control box simply requires an additional circuit board. Units with identical settings and the same sensor control requirements can be grouped this increases flexibility and reduces cost. KNX BACnetTM /IP BACnetTM MS/TP LON MODBUS RTU RS485 Different units are able to operate with different settings and sensors, if required. This provides maximum flexibility and the option of adapting When the control unit is units to local conditions and room connected to BMS, all 14 application. individual air handling units are controlled and 15 monitored by BMS.

Industrivej 59 DK - 9600 Aars Denmark Tel: +45 98 62 48 22 Fax: +45 98 62 57 77 info@airmaster.dk www.airmaster.dk Airmaster Applied Solutions Ltd. PO Box 6102 Innovation Centre Gallows Hill Warwick CV34 9PF United Kingdom Phone +44 (0)8448 099 993 Fax +44 (0)1926 797 001 www.airmaster-as.com We are not liable for any errors and reserve the right to make changes. See www.airmaster.dk for updated documentation.