Township of Maplewood

Similar documents
THE TOWNSHIP OF CRANBURY

Flemington Borough Fire Safety 38 Park Ave Flemington, NJ 08822

Requirements for Smoke / Carbon Monoxide / Fire Extinguisher Certification

Requirements for Smoke Detector / Carbon Monoxide/ Fire Extinguisher Certification

Certificate of Inspection CHECKLIST

Smoke Alarms and Carbon Monoxide Alarms

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Melrose Fire Department

Residential Care Facilities Requirements

Large Family Daycare Guideline

CARBON MONOXIDE ALARM STANDARDS ACT - ENACTMENT Act of Dec. 18, 2013, P.L. 1229, No. 121 Cl. 35 An Act

Residential-based Care Facility R-4 Guideline

Certificate of Continued Occupancy Residential Application

For additional information regarding R-3.1 residential care facilities please contact (951)

ADMINISTRATIVE ORDER # CERTIFICATES OF USE AND OCCUPANCY FOR EXISTING BUILDINGS

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

BALTIMORE CITY RENTAL LICENSE INSPECTION FORM RENTAL LICENSING INSPECTOR GUIDANCE

Smoke & Carbon Monoxide

Rental Housing Inspection Guide

SMOKE/CARBON MONOXIDE DETECTOR REQUIREMENTS

Photovoltaic (Solar) Array Installation Guide

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Residential Based Care Facility Guidelines

WARM WELCOME RISK ASSESSMENTS & HOMESTAY FIRE/GAS SAFETY

City of Madison Heights Landlord Licensing Program 300 W. Thirteen Mile Road Madison Heights, MI (248)

Norfolk Fire Department Fire Prevention & Information

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

Family Foster Home Fire Safety Evaluation Checklist Instructions

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

First Published in the Wichita Eagle on DELINEATED 10/02/2010 ORDINANCE NO.

2014 Alberta Building Code. Part 9 changes relating to Smoke and CO Alarms

THE GENERAL ASSEMBLY OF PENNSYLVANIA SENATE BILL

NCEHSA Conference. Carbon Monoxide Detector Regulations for Lodging Establishments (S.L )

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

Agency for Health Care Administration

FIRE PREVENTION STANDARDS

APPLICATION FOR Large Family Day Care Permit

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

EFFECTIVE DECEMBER 28, 2010 SECTION 610 CARBON MONOXIDE ALARMS

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

Residential Care Facilities

Denver Fire Department Fire Prevention Division

Short-Term & Accessory Short-Term Rental Safety Certification

Smoke Alarm and Carbon Monoxide Alarm Installation

Residential Alcohol & Drug Rehabilitation Facilities

CHILD CARE CENTER INSPECTION CHECKLIST 06C

SMOKE ALARMS. Obey the Law Save Your Life! Fairfax County Fire and Rescue Department

ORDINANCE NO

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

SECTION 915 CARBON MONOXIDE DETECTION

CHANGES TO THE TEXT OF THE 2010 CODE BOOKS

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

M E M O R A N D U M. NFPA 5000 A2011 ROP Letter Ballot

Agency for Health Care Administration

Residential Large Family Daycare Facilities

SANTA CLARA COUNTY Winchester Blvd., Los Gatos, CA (408) (408) (fax)

2007 CBC & CFC Residential Care Facility Requirements (24 hour care only)

PLAN NOW!! Plan your escape today Your life may depend on it tomorrow HOME ESCAPE PLAN EXERCISE

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

Fire and Life Safety GUIDE

(House Bill 849) Public Safety Rental Dwelling Units Carbon Monoxide Alarms

Residential Care Facilities Having 6 or Fewer Clients Classified in the California Building Code as R-3.1 Occupancies

Recent Revisions and Proposed Key Changes to Fire Code

Egress Window. Requirements for Building Permit Application

Apartment Fire & Safety Inspection. City of Guadalupe

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

Conversion to Vacation Home Permit Life Safety Survey

BUTTE COUNTY PERMIT NO: DEPARTMENT OF DEVELOPMENT SERVICES BUILDING PERMIT APPLICATION* APN: Property Address. Policy Number. Carrier.

Chapter Nursing Homes

Code Technology Committee 2006/2007 Cycle Area of study Carbon monoxide alarms Public comments

MODEL SS-901 EARLY WARNING PHOTOELECTRIC SMOKE & FIRE ALARM READ ALL INSTRUCTIONS

From Your Building Inspector

EXCELSIOR FIRE DISTRICT

Residential-based Care Facility R2.1 Guideline

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

Smoke Alarm User Manual

Housing and Fire Safety Tips for Your Home & Property. Micki Jones, SFFD Rosemary Bosque, DBI May 6, 2015, SF Main Library

Proposed Amendments: N.J.A.C. 5: , 6.4, 6.5, 6.6, 6.7, 6.21A, 6.25A, 6.26A,

Short Term Accommodations Fire Code Requirements

FIRE PREVENTION AND SAFETY IN THE HOME. Provided to You by Lawrence Laviolette CD Fire Safety Officer

SECTION 907 FIRE ALARM AND DETECTION SYSTEMS

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

WELCOME TO ROSEVILLE UNIVERSITY

Fire Safety Education in Multi- Unit Residential Buildings

2012 NC Building Code Chapter 2, 602.4, , , Chapter 35 Cross-Laminated Timber. ( Item B-1)

Comhshaol, Pobal agus Rialtas Áitiúil Environment, Community and Local Government. Fire safety at home

Section 8 Housing Choice Voucher Program. Housing Quality Standards (HQS) Inspection Checklist

a) Establishment of emergency procedures to be followed at the time of an emergency;

Locations must be selected where the detector is not to be disturbed during the measurement period.

Defend In Place 2012 IFC Overview of Institutional Occupancies

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

Residential Fire Protection

Agency for Health Care Administration

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

HOME FIRE SAFETY. Reference Guide

M E M O R A N D U M. NFPA Technical Committee on Building Services and Fire Protection Equipment

Smoke Alarm Legislation

DEALING WITH FIRE SAFETY

Transcription:

Township of Maplewood MAPLEWOOD, NEW JERSEY 07040 FIRE DEPARTMENT 105 DUNNELL ROAD P: 973-762-6500 F: 973-763-4622 MAPLEWOOD FIRE DEPARTMENT BUREAU OF TRAINING & FIRE SAFETY PROCEDURE FOR OBTAINING A CERTIFICATE OF SMOKE DETECTOR, CARBON MONOXIDE ALARM AND PORTABLE FIRE EXTINGUISHER COMPLIANCE 1. A Certificate of Smoke Detector, Carbon Monoxide Alarm and Fire Extinguisher Compliance (CSDCMAFEC) is required before any Use Group R-3 or R-4 dwelling unit is sold, leased or otherwise made subject to change of occupancy for residential purposes. These Use Groups include all buildings arranged for the use of detached one- and two-family dwelling units. These Use Groups shall also mean R-4 Units within R-2 Buildings, Bed and Breakfast homestays as well as one- and two-family dwellings constructed in accordance with the Uniform Construction code requirements for multiple single-family dwellings. 2. Prior to a CSDCMAFEC being issued, an inspection must be conducted by the Maplewood Fire Department to determine if smoke detectors, carbon monoxide alarms and fire extinguishers are properly located and operating. 3. Inspection requests must be made a minimum of ten (10) business days in advance of the inspection date by contacting the Secretarial Staff at 973-762-6500, ext. 10, during regular business hours. 4. An Inspection Fee is required. The fee schedule is as follows: $100 if scheduled at least ten (10) days prior to inspection date $125 if scheduled four (4) to nine (9) days prior to inspection date $175 if scheduled less than four (4) days prior to inspection date $50 per recheck inspection Cancellations must be made at least twenty-four (24) hours in advance to avoid charges Checks or money orders must be payable to the Township of Maplewood. A CSDCMAFEC will not be issued unless the Inspection Fee is paid.

5. Inspections are conducted between the hours of 1:30 p.m. and 4:30 p.m. Monday through Friday. Every effort is made to begin inspections at 1:30 p.m., however, inspections are conducted by in-service fire units and individual appointments can not be made. Owners or owner representatives must be at the home between the hours noted above or a second inspection date must be scheduled and an additional fee will be charged. 6. The CSDCMAFEC will remain valid for a period of six (6) months from the date of issue unless the occupancy or ownership of the dwelling changes in the interim. Certificates are not transferrable. 7. Guidelines for the proper installation of smoke detectors, carbon monoxide alarms and fire extinguishers are on the following pages. Please note: two-family dwellings also require smoke detectors to be located at the highest level of each common stairwell. 8. If in doubt as to the number of smoke detectors or carbon monoxide alarms required when installing them in a certain area or floor level, err on the side of caution and install an extra detector. REMEMBER: SMOKE DETECTORS, CARBON MONOXIDE ALARMS AND FIRE EXTINGUISHERS SAVE LIVES

CERTIFICATE OF SMOKE DETECTOR, CARBON MONOXIDE ALARM AND PORTABLE FIRE EXTINGUISHER COMPLIANCE N.J.A.C 5:70-4.19 - SMOKE ALARMS FOR ONE- AND TWO-FAMILY DWELLINGS; CARBON MONOXIDE ALARMS; AND PORTABLE FIRE EXTINGUISHERS 1. All smoke detectors shall bear a label showing the detector has been tested in accordance with Underwriters Laboratories Standard 217. Effective January 1, 2019, all battery operated smoke detectors shall be ten-year sealed battery-powered single station smoke alarms. 2. All smoke detectors shall be either battery operated or permanently wired to a non-switchable circuit of the house current. Detectors shall not be required to be interconnected 3. All equipment shall be installed in a workmanlike manner. 4. All equipment shall be so located that accidental activation will not be caused by jarring or vibration. *No Double sided tape is permitted to be used for mounting equipment. 5. All equipment shall be affixed to the wall or ceiling surface in accordance with the manufacturer s recommendations. 6. At least one smoke detector shall be installed on each level of the dwelling. If there are separate sleeping areas on any level, additional detectors are required in the immediate vicinity of each separate sleeping area. (Within 10 feet) 7. The preferable location for smoke detectors is on the center of the ceiling. Where this is impractical, wall mounting is acceptable. Ceiling mounted detectors shall be at least 4 inches from any side wall or other downward projection. For wall mounted units the top of the detector shall be within 4 and 12 inches of the ceiling. 8. Smoke detectors in room with ceiling sloped greater that 1 foot rise per 8 feet horizontal shall be located at the high side of the room. 9. Smoke detectors are not to be installed in stairways. 10. A smoke detector installed in the basement or to protect a level without a separate sleeping area shall be located in close proximity to the stairway leading to the floor above. 11. Smoke detectors installed to protect a separate sleeping area shall be installed outside of, but in the immediate vicinity of, the sleeping area. (Within 10 feet) 12. Smoke detectors are not required in crawl spaces or in unfinished attic spaces.

SMOKE DETECTOR PLACEMENT BASEMENT: FIRST FLOOR: One at the bottom of the stairs to first floor. One at the bottom of the stairs to second floor. SECOND FLOOR: One at the top of the stairs from first floor. THIRD FLOOR: ATTIC: One at the top of the stairs from the second floor. No detector needed if the attic is not finished.

CARBON MONOXIDE ALARMS Carbon Monoxide alarms shall be installed in accordance with the requirements of N.J.A.C 5:70-4.19d and NFPA-720-9.4. 4.19d Carbon monoxide alarms or detectors should be installed in any family living unit containing fuel-burning appliances or fireplace or having an attached garage. 4.19.d-1 A carbon monoxide alarm or detector should be centrally located outside of each sleeping area in the immediate vicinity of the bedrooms. Where bedrooms are separated and the audibility of the alarm or the detector to occupants within the bedroom area could be seriously impaired, more than one unit could be needed. Each alarm or detector should be located on the wall, ceiling, or other location as specified in the installation instructions that accompany the unit. *DETECTORS MUST BE INSTALLED OUTSIDE OF THE BEDROOM OR SLEEPING AREA, WITHIN 10 OF BEDROOM DOORS. 9.4.2.1 Each alarm should cause the operation of an alarm notification appliance that should be clearly audible in all bedrooms over background noise levels and with all intervening doors closed. 9.4.2.2.1 In a household occupied by one or more hearing impaired persons, each initiating device should cause the operation of a visible alarm signal(s) in accordance with 9.5.5 CARBON MONOXIDE DETECTOR PLACEMENT *Detectors must be installed outside of the bedroom or sleeping area, within 10 of bedroom doors. NOTE: Dwellings with existing fire detection and carbon monoxide systems installed through the building department (new construction/renovation and a certificate of occupancy was issued) must be maintained to the same level of the certificate of occupancy upon resale/lease. Any portion of an existing system not serviceable or repairable shall be replaced. Battery operated smoke detectors are not acceptable replacements.

PORTABLE FIRE EXTINGUISHER 1. The extinguisher must be located within 10 feet of the kitchen and located in the path of egress. 2. The top of the extinguisher must not be more than 5 feet above the floor. 3. The extinguisher must be visible and in a readily accessible location free of from being blocked by furniture, storage, or other items. 4. The extinguisher must be near a room exit or travel path that provides an escape route to the exterior. 5. At least one portable fire extinguisher shall be installed in all one and two family dwellings (except seasonal rental units) upon change of occupancy. 6. The extinguisher shall be listed, labeled, charged and operable. 7. The extinguisher shall be an approved listed and labeled type with a minimum rating of 2A-10B:C and weigh no more than 10 pounds. 8. The hangers or brackets supplied by the manufacturer must be used. 9. The extinguisher must be accompanied by an owner s manual or written information regarding the operation, inspection, and maintenance of the extinguisher 10. The extinguisher must be installed with the operating instructions clearly visible. New extinguishers are not required to be serviced or tagged, as long as the seller or agent can provide proof of purchase or receipt.