DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES

Similar documents
Washoe County Department of Social Services

MAINE. Downloaded g. Maintain an effective pest control program so that the facility is free of pests and rodents;

Residential Based Care Facility Guidelines

Agency for Health Care Administration

Chapter Nursing Homes

Residential Care Facilities Requirements

Family Foster Home Fire Safety Evaluation Checklist Instructions

Life Safety - Means of Egress/Exits NFPA 101

Agency for Health Care Administration

APPLICATION FOR Large Family Day Care Permit

SAFETY. USE OF SAFETY CHECK LISTS A safety check for compliance with current regulations should be performed yearly.

CHAPTER 7 ALTERATIONS LEVEL

September 1, Sincerely, Mike Montgomery Fire Marshal. M.S. Montgomery Fire Marshal

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

For additional information regarding R-3.1 residential care facilities please contact (951)

Residential-based Care Facility R-4 Guideline

Riverside County Fire Department Office of the Fire Marshal Market St., Ste. 150, Riverside, CA Ph. (951) Fax (951)

Agency for Health Care Administration

FIRE PREVENTION STANDARDS

Short Term Accommodations Fire Code Requirements

Business License Pre-inspection Checklist

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU STANDARD

FIRE INSPECTION GUIDELINES FOR FOSTER GROUP HOME PARENTS Effective June 1, 2002, Update September 2011

STATE OF MICHIGAN DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS LANSING

RULES OF THE TENNESSEE DEPARTMENT OF INTELLECTUAL AND DEVELOPMENTAL DISABILITIES OFFICE OF LICENSURE CHAPTER LIFE SAFETY LICENSURE RULES

Ten-Point Checklist for Emergency Preparedness

RESIDENTIAL CARE USER GUIDE UPDATES TO MANITOBA BUILDING/FIRE CODE:

Table of Contents CHAPTER 10 ADMINISTRATIVE RULES FOR CERTIFICATION OF CHILD CARE FACILITIES FIRE STANDARDS FOR FAMILY CHILD CARE HOME

Fraternity, Sorority and Dormitory Buildings R-2 Fire and Life Safety Standards Inspection Form Fire Code of New York State (19 NYCRR Part 1225.

EL DORADO COUNTY REGIONAL FIRE PROTECTION STANDARD

Safety And Fire Prevention. A guide to help Community Living Support Staff prepare for, respond to and prevent emergencies in a residential setting.

School Property REVIEWING YOUR BUILDINGS & GROUNDS

PROJECT: CIVIC ADDRESS:... PERMIT APPLICATION NO.: DATE:... CRP:. Certified Professional:.

Rental Housing Inspection Guide

To provide the requirements needed for Care Facilities Having 6 or Fewer Clients. This occupancy is classified as an R-3.1.

FIRE SAFETY AND PREVENTION POLICY

Property REVIEWING YOUR BUILDINGS & GROUNDS

Burien/Normandy Park Fire Department 900 SW 146 th ST PO Box Burien, WA BP (206) Fax (206)

Emergency Planning and Preparedness

Report on First Revisions with Statement June 2014 NFPA 101

GENERAL AREAS OF INSPECTION

Fire Department HEADQUARTERS Cathedral Oaks Road Santa Barbara, CA (805) FAX: (805) CODE SUMMARY

Fire and Life Safety Review Form

Procedure DESCRIPTION/OVERVIEW

Home Safety Checklist

Smoke Alarm and Carbon Monoxide Alarm Installation

FIRE SAFETY INSPECTION REPORT

Fire and Life Safety GUIDE

SPECIAL AMUSEMENT OCCUPANCIES HAUNTED HOUSE, SCARE HOUSE OR MAZE

CHILD CARE CENTER INSPECTION CHECKLIST 06C

Balloting Version First Draft NFPA 101 Life Safety Code Proposed 2015 Edition

5123: information. The graphic plan shall include, but may not be limited to: (a) A primary and secondary means of exit from each floor;

2012 B.C. Building Code Compliance Review (Division B Part 3)

Certificate of Inspection CHECKLIST

Denver Fire Department Fire Prevention Division

ICC CODE CORNER 2015 International Fire Code

A GUIDE TO THE ROCK ISLAND HOUSING CODE. Prepared By: The City of Rock Island Inspection Division

Fire Evacuation Plan Health Sciences & Human Services Library. UMB POLICE or

Fire Safety Risk Assessment for Treowen, Wonastow, Monmouth, NP25 4DL

Special attention should be given to new students, to students with special needs and to students enrolled in visiting classes.

CHAPTER 56 EXPLOSIVES AND FIREWORKS SECTION FIREWORKS 1.4G RETAIL STORAGE, DISPLAY, AND SALE

COUNTY OF SACRAMENTO DEPARTMENT OF COMMUNITY DEVELOPMENT BUILDING PERMITS & INSPECTION DIVISION

FIRE SAFETY INSPECTION REPORT

Consumer Fireworks Retail Sales (CFRS) Facility Requirements.

Short-Term & Accessory Short-Term Rental Safety Certification

97 FCV 006 Page 2 of 16 EXPLANATORY MATERIAL

Large Family Daycare Guideline

GROUP SR SPECIAL RESIDENCE (ASSISTED SELF-PRESERVATION) OCCUPANCIES

The one-half hour seminar in module 2 that follows, will complete the remainder of chapter 3, building planning, already begun in module 1.

School Fire Safety Checklist

Interim Amendments to Ontario s 2012 Building Code Retirement Homes. August 17, 2017

ALABAMA. Downloaded

Home Evaluation Questionnaire for PLOF

PARISH SELF-INSPECTION GUIDE

1. A fire certificate is issued under Section 76 of the Occupational, Safety and Health ActNo. 28 of 2005.

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

Is the address of your property clearly visible and marked in large numbers that can be easily seen from the street?

Item Referenced and Amendments Building 1 Building 2 Analysis, Review and Remarks. Page 1 of 15

Chapter BUILDING CODE*

FIRE FIRE FACT NO. 057 CHECKLIST(s) : Rev. 11/2006 TITLE : CHILD CARE HOMES CHECKLIST ITEM(s) : REFERENCE(s) : K.S.A

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU INSPECTION GUIDELINE RESIDENTIAL CARE FACILITIES 2007 CBC/CFC (R-3.1)

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

FIRE SAFETY UPGRADING CONSIDERATIONS for EXISTING SENIOR CITIZEN LODGES

FIRE SAFETY PRACTICES AND PROCEDURES

FIRE PREVENTION EXHIBIT GUIDELINES

2. The Group F occupancy has have an a combined occupant load of 500 or more above or below the lowest level of exit discharge.

UNIVERSITY COLLEGE LONDON EMERGENCY PLAN. Regulatory Reform (Fire Safety) Order 2005 PART ONE - SPECIFIC INSTRUCTIONS & OTHER RELEVANT INFORMATION:

New DATE OF BLDG. PERMIT OR PLAN APPROVAL: SURVEYOR (SIGNATURE) TITLE OFFICE DATE REVIEW AUTHORITY OFFICIAL (SIGNATURE) TITLE OFFICE DATE

MULTI-LEVEL & COVERED BOOTH CONDITIONS

PENNSYLVANIA. Downloaded

EMERGENCY EVACUATION PLAN

Fire Evacuation Plan Davidge Hall. UMB POLICE or

Exit Routes. Introduction/Overview. OSHA Regulations. Exit Route

Operations Maintenance and Evaluations

Group Organizers: Let s Get Started!

GROUP SR SPECIAL (ASSISTED SELF-PRESERVATION) OCCUPANCIES

Safe at Home. Suggestions for Homeowner Created in partnership with the Administration on Aging. Assessor: Assessor: Homeowner Name: Address:

LOCAL AMENDMENTS TO THE INTERNATIONAL FIRE CODE 2006 EDITION

GUIDELINES FOR INSPECTING GROUND BASED SPARKLING DEVICE (GBSD) RETAIL SALES FACILITIES

Johnson County, Kansas. Home Daycare Handbook 2013 Edition

Transcription:

DEPARTMENT OF CONSUMER AND INDUSTRY SERVICES DIVISION OF ADULT FOSTER CARE LICENSING ADULT FOSTER CARE FACILITIES (By authority conferred on the department of social services by section 9 of Act No. 380 of the Public Acts of 1965, as amended, and sections 10 and 13 of Act No. 218 of the Public Acts of 1979, as amended, being SS16.109, 400.710, and 400.713 of the Michigan Compiled Laws) PART 2. FAMILY HOMES, FIRE SAFETY R 400.2201 Scope. Rule 201. This part applies only to family homes which were licensed effective March 27, 1980, and which meet the requirements of section 21 of the act. R 400.2202 - R 400.2224 Rescinded. R 400.2231 Home environment. Rule 231. All occupied rooms shall be of standard lath and plaster construction or equivalent. R 400.2232 Rescinded. R 400.2233 Bedrooms. Rule 233. A room shall not be used as a bedroom where more than 1/2 of the room height is below grade except, where the ceiling of such portion of a building is located 5 feet or more above grade for more than 25% of the perimeter measurement of the building. Such acceptable bedrooms shall be provided with 2 acceptable means of egress. Page 1

R 400.2234 Rescinded. R 400.2241 Rescinded. R 400.2242 Interior finishes and materials. Rule 242. Paper, cardboard, asphalt paper, or other highly flammable material shall not be used for the interior finish of a building. R 400.2243 Exits. Rule 243. (1) A means of egress shall be considered the entire way and method of passage to free and safe ground outside a building. Means of egress shall be maintained in unobstructed, easily traveled condition at all times. Where basements are regularly utilized for resident activities, there shall be 2 acceptable means of egress. Doors which form a part of a required means of egress shall be equipped with positive-latching, non-locking-against-egress hardware and shall be not less than 36 inches in width in new construction and not less than 30 inches in width in existing facilities and shall insure adequate egress for residents requiring wheelchairs, including ramps where necessary. (2) The first floor of a family home shall have not less than 2 separate and independent means of egress leading to the outside. (3) In new or remodeled family homes, corridors shall lead directly to the outside or to required stairways having egress directly outside at grade level. (4) Occupied room and exterior door hardware shall be positive latching and nonlocking against egress. (5) New and existing family homes accommodating residents who regularly require wheelchairs shall be equipped with ramps located at primary and secondary means of egress. A ramp shall not exceed 1 foot of rise in 12 feet of run. R 400.2244 Heating. Rule 244. (1) Except as provided herein, a family home shall be heated by an approved heating plant. If the heating plant is located in the basement of a family home, standard building material is sufficient for the floor separation which shall include at least 1 3/4-inch solid wood core door or equivalent to create a floor Page 2

separation between the basement and the first floor. If the heating plant is on the same level with the residents, the furnace room shall be separated from the remainder of the building with materials that will afford a minimum 1 hour protected enclosure. A permanent outside vent which cannot be closed shall be incorporated in the design of heating plant rooms so that adequate air for proper combustion is assured. Space heaters are prohibited. (2) Factory mutual and underwriters' laboratories approved permanent, fixedtype electrical heating, such as recognized panel or baseboard fixed-type may be utilized in any location. In existing homes where an American gas association approved sealed combustion wall heater has been installed in accordance with both the AGA and the manufacturer's recommendations, approval will be given if the unit is located on an outside wall, obtains combustion air directly from the outside and vents products of combustion directly to the outside. (3) Flame-producing water heaters or incinerators shall be installed with the same protection as a heating plant. (4) Storage of combustible materials is prohibited in rooms containing the heating plant, water heater, or incinerator. R 400.2245 Fire extinguishers. Rule 245. A minimum of one 5-pound multi-purpose fire extinguisher or equivalent shall be provided for use in a family home on each occupied floor and in the basement. R 400.2246 Electrical service. Rule 246. Electrical service shall be maintained in a safe condition.where conditions indicate a need for inspection, and on all new or remodeled projects, the electrical service shall be inspected by a qualified electrical inspection service and a copy of the inspection report shall be submitted to the department. R 400.2247 Safety generally. Rule 247. (1) Stairways shall have sturdy and securely fastened handrails, not less than 30 inches nor more than 34 inches above the upper surface of the tread. Exterior stairways and porches shall have handrails on the open sides. (2) Scatter or throw rugs on hard finished floors shall have a nonskid backing. (3) Handrails and nonskid surfacing or strips shall be installed in showers and bath areas. (4) Sidewalks, fire escape routes, and entrances shall be kept free of any hazards such as ice, snow and debris. Page 3

(5) A yard area shall be kept free from all hazards, nuisances, refuse, and litter. R 400.2248 - R 400.2257 Rescinded. R 400.2261 Emergency preparedness. Rule 261. (1) A family home shall have a telephone. A family home shall have a written procedure to be followed in the case of fire or medical emergency. Responsible foster family members or employees shall be familiar with emergency planning and their responsibilities. Responsible persons shall be capable of using the telephone to summon appropriate assistance and carry out an evacuation plan. (2) An emergency plan shall specify persons to be notified, locations of alarm signals and fire extinguishers, evacuation routes, procedures for evacuating residents of limited mobility and visitors, and provide for at least 4 fire drills per year. Emergency telephone numbers shall be immediately available. (3) Residents, insofar as possible, adult members of the foster family and responsible persons shall be familiar with emergency procedures. R 400.2271 - R 400.2274 Rescinded. R 400.2275 Rescinded. PART 3. GROUP HOMES R 400.2301 Rescinded. R 400.2302 Rescinded. Page 4

R 400.2303 Rescinded. R 400.2304- R 400.2324 Rescinded. R 400.2331 - R 400.2334 Rescinded. R 400.2341 - R 400.2347 Rescinded. R 400.2348 - R 400.2357 Rescinded. R 400.2361 Rescinded. R 400.2371 - R 400.2375 Rescinded. R 400.2376 Smoke detection equipment. Rule 376. (1) At least 1 single station smoke detector shall be installed at the following locations: (a) Between the sleeping areas and the rest of the home. In homes with more than 1 sleeping area, a smoke detector shall be installed to protect each separate sleeping area. (b) On each occupied floor, in the basement, and in areas of the home which contain flame- or heat-producing equipment. (2) Approved heat detectors may be installed in the kitchen and in other areas of the home containing flame- or heat-producing equipment in lieu of smoke detectors. (3) If batteries are used as a source of energy, they shall be replaced in accordance with the recommendations of the alarm equipment manufacturer. Page 5

(4) Detectors shall be tested and examined as recommended by the manufacturer. (5) This rule does not apply to the following: (a) Adult foster care small group homes which are licensed effective March 27, 1980, and which meet the requirements of section 21 of Act No. 218 of the Public Acts of 1979, as amended, being S400.721 of the Michigan Compiled Laws. (b) Adult foster care small group homes licensed or proposed to be licensed for more than 6 adults. History: 1982 AACS. Page 6