FIBERSHIELD EW NEW PRODUCT LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) FIRE CURTAINS. Supported by full scale fire test data

Similar documents
Fire Curtains and Radiation Attenuation

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Benefiting Government, Industry and the Public Through Innovative Science and Technology. Barry L. Badders, Jr. P.E.

FireMaster Instrument cable tray fire protection

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Forbo Flooring Attn. Mr. A. Tijhof Postbus AA Krommenie. Report. Sponsor : Contractor, manufacturer : Forbo Flooring. Lot. No. : 66869/3877.

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Appendix A: US Fire Statistics Tables

1.0 INTRODUCTION. Shaw Industries Group 2 SwRI Project No c

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

STOPLINE FIRE RATED GLAZED

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

IMO UNIFIED INTERPRETATIONS TO SOLAS CHAPTER II-2 AND RELATED FIRE TEST PROCEDURES

M E M O R A N D U M. Diane Matthews, Administrator, Technical Projects. NFPA 101 First Draft Letter Ballot (A2014)

HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR

2009 International Fire Code Errata. SECOND PRINTING (Posted April 6, 2010)

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Fire Collars for Floor Wastes Understanding BCA Compliance Options

FIRE-RESISTANCE TEST ON DOWNLIGHT COVERS INSTALLED IN PLASTERBOARD CEILINGS

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

C-01 FIRE DECKS AND BULKHEADS

Webinar November 12, 2014

Compensation for Missing Fire Partitions by Water Mist

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

ASTM F25 SEMINAR Fire Testing for SOLAS and Navy Vessels New Test Procedures and Materials Approval Process

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Loss Prevention Standards

Guideline No 7:2005. European Guideline. Safety distances between waste containers and buildings. CFPA-E -Guidelines

1 P age w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN

Safety distance between waste containers and buildings. CFPA-E Guideline No 7:2011 F

WELDING, CUTTING, AND BRAZING SAFETY PROGRAM

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

REACTION TO FIRE TESTS FOR BUILDING PRODUCTS DETERMINATION OF THE HEAT OF COMBUSTION ACCORDING TO STN EN ISO 1716: 2003

RESOLUTION MSC.265(84) (adopted on 9 May 2008) AMENDMENTS TO THE REVISED GUIDELINES FOR APPROVAL OF SPRINKLER SYSTEMS EQUIVALENT TO THAT REFERRED TO

4 June This circular supersedes MSC/Circ.914. *** I:\CIRC\MSC\01\1272.doc

FM Approval Standard For Cavity Walls And Rainscreens

Area Heater AH100 Series

New European Fire Testing Classification for Construction Products

UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS

MEDIUM-DENSITY HOUSING # 7. Fire safety

Intertek. REPORT NUMBER: SAT-005 ORIGINAL ISSUE DATE: October 29,2008 REVISED DATE: November 19, 2008

8.1. Fire and Heritage. The maintenance series. Information sheet. Guidelines on Fire Safety in Heritage Buildings

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

Contents Page No. Page 1 of Introduction Specimen verification Description of supporting constructions...

Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

CUSTOMER TECH MEMO # 315

Code Technologies Committee Report Fire Rated Glazing Group A changes: Fire rated glazing

Global Requirements for the Fire Protection of Ships. Dr Janet Murrell Warrington Certification Ltd

Analysis Report

Food Service Technology Center

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

Significant Changes to the 2012 IFC Semiconductor Fabrication Facilities. Scott Stookey Senior Technical Staff International Code Council, Austin TX

An experimental study of the impact of tunnel suppression on tunnel ventilation

FOR YOUR SAFETY FOR OUTDOOR USE ONLY PROPANE GAS. Model No. AH2069ODS, AH2063ODS

UC Irvine Environmental Health & Safety TITLE: FIRE WATCH AND OUT OF SERVICE NOTIFICATION

BS EN ISO : 2010

Soot Mitigation Strategies

SPREAD OF FIRE UP BUILDINGS VIA WINDOWS.

PRODUCT SPECIFICATION FireMaster Plus

Heating Systems for Museeum and Worship Places

IMO COMPREHENSIVE REVIEW OF THE FIRE TEST PROCEDURES CODE

Safe Schools: A Health and Safety Check

UL 94 Flammability Ratings: Introduction

/WON BuyLine 3726 WON-DOOR. FireGuard. The ORIGINAL horizontal sliding accordion fire door.

Analysis Report

Fire-resistance test on fire collars protecting a plasterboard wall penetrated by services

ASSESSMENT OF FIRE BEHAVIOUR OF TIMBER PARTITION MATERIALS WITH A ROOM CALORIMETER

Fire-Rated Glazing Changes in 2012 International Building Code (IBC)

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

CRAFTSMAN EXAMINATION, NOVEMBER 2009 GASFITTING QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Fike set out to develop a better understanding of the power density trends in data centers around the world.

Firefighting operations on multi-tiered vehicle stacking buildings F5-13 GD

FIREMASTER CONCERTINA TM

FRANCE M & F RANKING ACCORDING TO NF F

REPORT NUMBER: SAT-001B ORIGINAL ISSUE DATE: February 29, 2016 REVISED DATE:

FACADES AND FIRE The Essential Elements

Explosion Protection Engineering Principles

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Schueco Fire and Smoke Protection Systems

Large-scale fire test for interior materials of the Korean high speed train

Report on First Revision June 2014 NFPA 101

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

CANADIAN FIRE ALARM ASSOCIATION An Update on Standards, Technologies and Solutions. Smoke Characterization Study

Spray sprinkler system

July 22, Stewart Audio Inc. Brian Mccormick Po Box 4058 Mountain View, CA File SV17764 / Project 09CA34798

ASSESSING THE FIRE PERFORMANCE OF ELECTRIC CABLES (FIPEC)

TEST REPORT. NFPA 253 / ASTM E648-14c Standard Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

Sprinklers in Combustible Concealed Spaces

ACTIVE FIRE CURTAINS INTISI7

Fire propagation over combustible exterior facades exposed to intensified flame in Japan

Safety Code Users. Fire Tests for Life SUPPLEMENT 3. Marcelo M. Hirschler FIRE PROPERTIES

Operation & Maintenance Manual

Fire protection documentation. CFPA-E Guideline No 13:2015 F

BS EN ISO : 2010

CLASSIFICATION OF REACTION TO FIRE PERFORMANCE IN ACCORDANCE WITH EN :2007+A1:2009

Transcription:

LOW RADIANT HEAT TRANSFER ( PARTIAL PARTIAL INSULATION ) GENERAL Fibershield EW is a NEW and INNOVATIVE low radiation attenuation and partially insulating automatic fire curtain. It was developed to meet the requirements of Fire Safety Engineering projects, where architectural requirements are demanding automatic concealed fire separation barriers but want to use them in areas where radiant heat transfers and temperatures in close vicinity of the curtain material on deployment need to be minimized. Fibershield EW incorporates a new composite fabric which has been engineered to be both durable, to allow thousands of trouble free operations, but also to provide a remarkable fire performance, keeping temperatures and radiant heat transfer levels adjacent to the fabric below levels where combustibles will ignite or where people passing near the opening might be subjected to untenable conditions. Note: the EW rating is widely used in Europe and according to EN 13501-2, requires radiant heat transfer to not exceed 15 kw/m2 for the relevant duration. NEW PRODUCT Supported by full scale fire test data KEY FEATURES Developed for Fire Safety Engineers Highest performance available at present Full EW120 European fire rating Fire tested to AS 1530 Part 4 More than 2 hours Integrity Low radiant heat transfer Partial insulation No drenchers required Please refer to our Fibershield EW Technical Supplement for relevant performance data 0 Minute 60 Minutes 90 Minutes 120 Minutes 1 of 1

Overview: Architects are discovering the benefits of using automatic fire curtain technology to provide open plan areas, yet maintain fire separation. One of the limitations of conventional integrity only fire curtains, just like conventional fire shutters is the radiant heat transfer through the thin and flexible fabric barrier. Fire Safety Engineers and other fire protection designers have been specifying fire curtains, but to minimize the radiant heat transfer they are forced to use fire sprinklers to cool the curtain in the advent of a fire, and reduce the potential for radiant heat transfer through the barrier which can potentially cause ignition of combustibles or untenable condition for occupants in its vicinity. Stoebich is proud to have developed, fire tested and now launched a suite of low radiant heat transfer, ( partially insulating) automatic fire curtains. These new product are being marketed under the Fibershield EW name, as the mechanical and electrical operational characteristics are essentially the same as the standard Fibershield, but incorporate some engineered high performance flexible barrier fabric materials. The Fibershield EW product does not provide full insulation, as defined in the Building Code of Australia, requiring temperature measurements directly on the surface of the barrier to not rise more than 140 degrees C during fire testing to AS1530 Part 4, however many would consider this a conservative acceptance criteria. So what sort of information is important to a fire safety engineer when assessing the suitability of Fibershield EW? Radiant heat transfer through the assembly Ignition times for combustible elements in the vicinity of the assembly Temperatures measured close to the surface 0 Minute 60 Minutes 90 Minutes 120 Minutes Information given in this publication is given to the best of our knowledge and in good faith. Smoke Control is not responsible if recipients of test reports, assessments or literature misinterpret the contents and wrongly use products based on those misinterpretations. No liability is accepted for error omissions in this document. Smoke Control reserves the right to change specification without notice. 1 of 6

Summary of fire testing conducted on Fibershield EW: A full scale representative assembly was fire tested to the principles of AS1530 Part 4 and achieved over 2 hours integrity (resistance to spread of flames and hot gases with perimeter gaps verified with cotton wool pad test). To provide data that Fire Safety Engineers can use, the following additional equipment and instrumentation was provided: Radiant heat measurement at the centre at 500mm and 1000 mm away from the assembly where the radiant heat would be highest. Paper, cotton wool and wood, mounted 100mm from the face of the assembly to observe their ignition times Temperature measurement at 60mm from the face of the assembly measured using AS1530 Part 4 thermocouples (copper disks covered in ceramic insulation pads) mounted on a thin mesh grid. Temperature measurement at 20mm and 30mm from the face of the assembly measured using mantle thermocouples which are different to those specified in AS1530 Part 4. Radiant heat transfer through the assembly: The radiant heat measurements (radiant heat flux) in kw/m 2 during the fire test measured at 500mm and 1000mm yielded the following results: Radiant heat flux in kw/m 2 measurement versus proximity Time Distance from assembly (minutes) 500mm 1000mm 30 2.0 kw/m 2 0.1 kw/m 2 60 5.0 kw/m 2 0.7 kw/m 2 90 8.4 kw/m 2 2.2 kw/m 2 120 12.8 kw/m 2 4.0 kw/m 2 The actual graphs from the fire test are shown as Appendices 1 & 2. Note: For the purposes of European Standardisation, EW is a criteria that applies to product which achieve integrity and reduced radiation, the latter defined as radiant heat flux not exceeding 15 kw/m 2 measured at 1000mm from the assembly. Fibershield EW is classified in European terms as a full EW120 assembly, having not exceeded these radiant heat flux threshold for over 120 minutes (2 hours). Refer EN 13501-2 2 of 6

Ignition times for combustible elements in the vicinity of the assembly: Paper, cotton wool and wood were mounted adjacent to the curtain assembly for the duration of the fire test to measure the ignition time for these combustible materials and the following results were observed: Ignition times for materials placed 100mm from the assembly Material Ignition time (minutes) Paper 148 Cotton Wool 163 Wood 164 Temperatures measured close to the surface: Temperature rise measurements were taken for the duration of the fire test at locations adjacent to, but not directly on the surface of the assembly. Measurements were recorded with two different types of thermocouples: 1. AS1530 Part 4 thermocouples (copper disks covered with ceramic fibre insulating pads) fixed onto a thin mash grid, and 2. Mantle type thermocouples (non compliant with AS1530 Part 4). A summary of the temperature rise readings is as follows for the respective distances: Temperature rise in Degrees C at distances close to the assembly Time Proximity to assembly (minutes) 20mm 30mm 60mm 30 16 * 22 * 56 ** 60 22 * 29 * 83 ** 90 32 * 43 * 120 ** 120 43 * 53 * 153 ** * Temperature measurement using mantle thermocouple ** Temperature measurement using AS1530 Part 4 thermocouples The actual graphs from the fire test are shown as Appendices 3, 4 & 5. 3 of 6

Appendix 1: Radiant heat transfer measured at 1000mm from assembly Appendix 2 Radiant heat transfer measured at 500mm from assembly 4 of 6

Appendix 3: Temperature rise at 20mm from assembly Appendix 4: Temperature rise at 30mm from assembly 5 of 6

Appendix 5: Temperature rise at 60mm from assembly Thermocouples are mounted on a thin mesh grid. 6 of 6