Ameristar SUBMITTAL M4AH4E26B1A00AA. 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA TAG:

Similar documents
Submittal. 1 1/2 Ton Convertible Air Handler TEM3A0B18S21SA TEM3A0B18-SUB-1C-EN. July 2014 TAG:

Submittal. 2 Ton Convertible Air Handler TEM3A0B24S21SA TEM3A0B24-SUB-1C-EN. July 2014 TAG:

Submittal. 5 Ton Convertible Air Handler TEM3A0C60S51SA TEM3A0C60-SUB-1C-EN. July 2014 TAG:

Modular Multi-position Air Handler

Multi-position, Upflow, Horizontal Left, or Horizontal Right, Modular Air Handlers

Variable Speed Convertible Air Handler 5 Ton

Variable Speed Convertible Air Handler 4 Ton

Variable Speed Convertible Air Handler 2 1/2 Ton

2 Ton Convertible Air Handler TAM7A0A24H21SD Standard Coil TAM7A0A24H21EA Black Epoxy Coil

Product Data. Convertible Air Handlers 1 1/2 5Ton

Product Data. Convertible Air Handlers 1 1/2 5Ton

Modular Multi-position Air Handlers

Modular Multi-position Air Handlers

3-11/ /8 4-5/16 6-5/8 5-7/8 1-9/16. Condensate drain connection 3/4 NPTI (Trap required) Electrical service access compartment panel

Vertical Upflow Horizontal Left Air Handlers

Cooling/Heat Pump Convertible Air Handlers

36,000-62,000 BTUH Nominal Capacity

Modular Multi-position Air Handlers

Cooling/Heat Pump Convertible Air Handlers

2TEH3F18A1000A 2TEH3F24A1000A 2TEH3F30A1000A 2TEH3F36A1000A 2TEH3F42A1000A 2TEH3F48A1000A 2TEH3F60A1000A 1½

Cooling/Heat Pump Convertible Air Handlers

Modular Multi-position Air Handlers

Service Facts. Air Handler - Convertible Model: Series 2 Air Handlers ton GAT2A0B42S31SA GAT2A0C48S41SA GAT2A0C60S51SA WARNING: GAT2-SF-1B

Rheem Air Handlers. RHML- Series X-13 (ECM) Motor

WH1T SERIES Constant Torque Motor (ECM) Efficiencies up to 14 SEER. FORM NO. H REV. 1 Supersedes Form No. G Rev. 3

Rheem High Efficiency Air Handler

HIGH EFFICIENCY AIR HANDLER

Rheem Standard Efficiency Air Handler

Ruud Standard Efficiency Air Handler

Product catalog. Hyperion TM split systems 60 Hz / R410A / 13 SEER SSA-PRC009-E4

Ruud Standard Efficiency Air Handler

Bosch BVA Series Air Handler

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

Submittal. Split System Cooling 5.0 Ton 4A7A3060D1000P TAG:

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

Rheem High Efficiency Air Handler

Service Facts WARNING: GAM5-SF-1D. Convertible Air Handlers ! WARNING

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

Rheem High Efficiency Two-Stage EcoNet Enabled Air Handler

Hyperion Field Reference Data TAM8

Uncased Vertical Aluminum Upflow Cooling/HP Coils 2-5 Ton 4PXA. Heat Pump / Cooling Coils for R-410A PUB. NO

Submittal. Split System Cooling 4A7A6024J-SUB-1B-EN. January A7A6024J1000B TAG:

Product Data /4WCC3018A through 2/4WCC3060A Single Package Convertible Heat Pump 13 SEER 1½ - 5 Ton R-22/R-410A

TECHNICAL GUIDE MODELS: MV MODULAR VARIABLE SPEED AIR HANDLERS FOR USE WITH SPLIT SYSTEM COOLING & HEAT PUMP DESCRIPTION FEATURES

Hyperion TM Split Systems


Aluminum Cased Heat Pump / Cooling Coils 2-5 Ton

HIGH EFFICIENCY AIR HANDLER

Split System Cooling Product & Performance Data

4YCC3048A3096A /3/ /

SPECIFICATIONS 4YCC3060A-SPEC-1A SINGLE PACKAGED GAS HEATING ELECTRIC COOLING 4YCC3060A1096/120B TAG:

AIR HANDLERS AIR HANDLERS

Note: A/TZONE 950/850 communicating thermostats MUST be used for Variable Speed Outdoor units.

Rheem Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Technical Guide DESCRIPTION CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240A 20 NOMINAL TONS (WORLD 50 HZ) FEATURES XTG-A-0307

MERIT Series R-410A - Upflow / Horizontal

TECHNICAL GUIDE HIGH EFFICIENCY, STANDARD ECM VERTICAL WALL MOUNT AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: EWX*18-36

CBX32MV (HFC-410A) SERIES UNITS

4YCC3036A1075B /1/ / YCC3036A1064B /1/ /

2YCC3060A1120A /1/ / YCC3060A1096A /1/ /

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Ruud Air Handler. RF1T- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RF1P- Series PSC Motor Efficiencies up to 14.5 SEER

AIR HANDLERS AIR HANDLERS RBHP- Models featuring R-22 Refrigerant Models featuring Earth-Friendly R-410A Refrigerant

TECHNICAL GUIDE VARIABLE SPEED AIR HANDLERS DESCRIPTION FEATURES Rev. A (0105)

Rheem Air Handler. RHBL- Series X-13 (ECM) Motor Efficiencies up to 16 SEER. RHAL- Series PSC Motor Efficiencies up to 14.5 SEER

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Ruud High Efficiency Air Handler

4TTB3030D1000B 208/230/1/60 4TTB3036D1000B 208/230/1/ RECIP /230/1/ RECIP YES YES

High Heat COP. High/Low Stage

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

Submittal. Single Packaged Heat Pump 15 SEER Convertible 4WCY5024A-SUB-1A-EN. March WCY5024A1000A TAG:

MERIT Series R-410A - Upflow / Horizontal

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

INDOOR COILS INDOOR COILS. Airflow Capacities 400 to 2,250 CFM [188.8 to L/s] FORM NO. C REV. 14 Supersedes Form No. C Rev.

Bosch BVA Series Air Handler

Corp L2 Revised

4TTB3060D1000B 208/230/1/60 35 SCROLL /230/1/ /8

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

TECHNICAL SPECIFICATIONS B6VMMX

TECHNICAL SPECIFICATIONS

Split System Cooling Product Data XB 1000

Service Facts. Split System Cooling 3.0 Ton 4A7A6036J-SF-1B-EN. January A7A6036J1000A

Advance Release September 2009

Rheem High Efficiency Modulating EcoNet Enabled Air Handler

PRODUCT SPECIFICATIONS 2YCC3036A1096A /1/ /

PRODUCT SPECIFICATIONS 2YCC3048A1120A /1/ /

208/230/1/ CLIMATUFF /230/1/ YES NO NO PROPELLER 23-1 DIRECT / /230/1/ SPINE FIN

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

AIR HANDLERS RBHA- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

Product Data. Single Packaged Heat Pump 14 SEER Convertible, 2 5 Ton B-EN. December 2014

MERIT SERIES Up Flow / Horizontal

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

Transcription:

Ameristar TAG: M4AH4E26B1A00AA SUBMITTAL 2.0 Ton Multi-position Air Handler M4AH4E26B1A00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE. SUPPLY AIR HIGH VOLTAGE CONNECTION 7/8, 1-3/8, 1-3/4 DIA KNOCK OUTS FLANGES ARE PROVIDED FOR FIELD INSTALLATION 10 16 A W LOW VOLTAGE CONNECTION BREAKER SWITCH (FOR ELECTRIC HEATER ONLY) H VAPOR LINE CONNECTION COPPER (SWEAT) LIQUID LINE CONNECTION COPPER (SWEAT) D PRIMARY DRAIN CONNECTION 3/4 UPFLOW UNIT SHOWN; UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY. NOTE: All dimensions are in mm/inches. Model H W D A M4AH4E26B1A00AA 100 (41-3/ 8) 460 (18-1/8) 20 (20-1/2) 406 (16)

PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS MODEL M4AH4E26B1A00AA RATED VOLTS/PH/HZ. 208-2/1/60 RATINGS INDOOR COIL Type See O.D. Specifications Plate Fin Rows F.P.I. 4-17 Face Area (sq. ft.) 4.01 Tube Size (in.) 9/32 Refrigerant Control Orifice Drain Conn. Size (in.) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN Type Centrifugal Diameter-Width (In.) 10-/8 X 8-1/8 No. Used 1 Drive - No. Speeds Direct - vs. in. w.g. See Fan Performance Table No. Motors H.P. 1-1/3 Motor Speed R.P.M. 100 Volts/Ph/Hz 208-2/1/60 F.L. Amps 2.6 FILTER Filter Furnished? No Type Recommended Throwaway No.-Size-Thickness 1-16 X 20-1 in. REFRIGERANT R-410A Ref. Line Connections Brazed Coupling or Conn. Size in. Gas 3/4 Coupling or Conn. Size in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 42-7/10x 21 x 24-1/6 Uncrated 41-3/8 x 18-1/8 x 20-1/2 WEIGHT Shipping (Lbs.)/ Net (Lbs.) 114/101 Heater Kit Model Used Electric Heat (kw) Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity 240V 208V 240V 208V Minimum Heating Blower Speed Without HP With HP MAYHTR1A0BKR* 29.4 2.9 MAYHTR1A08BKR* 7. 42.4 37.2 4 40 MAYHTR1A10BKR* 10.4.4 60 0 Note: Factory set at Medium High Speed. Motor Speed 1 2 3 4 0(0) 90 883 1103 44 842 1073 AIR FLOW PERFORMANCE 11 447 796 1036 M4AH4E26B1A00AA External Static Pressure-Inches W.C. (kpa) 0.1(.02) 0.2(.0) 0.3(.07) 0.4(.10) 0.(.12) 0.6(.1) 78 998 404 717 967 34 681 934 311 896 0.7(.17) 8 0.8(.20) 273 239 681 633 91 3 490 446 388 34 313 788 736 687 648 97 8 11 473 429 642 99 24 814

Mechanical Specifications Unique Cabinet Design - Metal shell and glass cotton thermal insulation layer Multi-Position UP/Down Flow Horizontal Left /Right Braze in Refrigerant Connection Primary/Secondary Condensate Connections Blower with Integrated Slide Deck for Easy Removal Inner-groove aluminum tube and high-efficiency aluminum fin Coil with Integrated Slide Deck for Easy Removal More auxiliary Electric Heaters optional ECM Speed Motor High Efficiency Integrated Horizontal Drain pans and metal Vertical Drain Fused 24V Power -Year Warranty. 10-Year Warranty Registered. Warranty Mirrors Outdoor. Optional extended warranty available. Ameristar The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.

Ameristar TAG: M4AH4E37B1B00AA SUBMITTAL 3.0 Ton Multi-position Air Handler M4AH4E37B1B00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE. SUPPLY AIR HIGH VOLTAGE CONNECTION 7/8, 1-3/8, 1-3/4 DIA KNOCK OUTS FLANGES ARE PROVIDED FOR FIELD INSTALLATION 10 16 A W LOW VOLTAGE CONNECTION BREAKER SWITCH (FOR ELECTRIC HEATER ONLY) H VAPOR LINE CONNECTION COPPER (SWEAT) LIQUID LINE CONNECTION COPPER (SWEAT) D PRIMARY DRAIN CONNECTION 3/4 UPFLOW UNIT SHOWN; UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY. NOTE: All dimensions are in mm/inches. Model H W D A M4AH4E37B1B00AA 1180 (46-1/ 2) 00 (19-/8) 0 (21-/8) 46 (18)

PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS MODEL M4AH4E37B1B00AA RATED VOLTS/PH/HZ. 208-2/1/60 RATINGS INDOOR COIL Type See O.D. Specifications Plate Fin Rows F.P.I. 4-17 Face Area (sq. ft.) 4.01 Tube Size (in.) 9/32 Refrigerant Control Orifice Drain Conn. Size (in.) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN Type Centrifugal Diameter-Width (In.) 10-/8 X 10-3/4 No. Used 1 Drive - No. Speeds Direct - vs. in. w.g. See Fan Performance Table No. Motors H.P. 1-1/2 Motor Speed R.P.M. 100 Volts/Ph/Hz 208-2/1/60 F.L. Amps 3.0 FILTER Filter Furnished? No Type Recommended Throwaway No.-Size-Thickness 1-18 X 20-1 in. REFRIGERANT R-410A Ref. Line Connections Brazed Coupling or Conn. Size in. Gas 3/4 Coupling or Conn. Size in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) 47-4/ x 22-3/ x 2-7/10 Uncrated 46-1/2 x19-/8 x 21-/8 WEIGHT Shipping (Lbs.)/ Net (Lbs.) 141/12 Heater Kit Model Used Electric Heat (kw) Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity 240V 208V 240V 208V Minimum Heating Blower Speed Without HP With HP MAYHTR1A0BKR* 29.9 26.4 MAYHTR1A08BKR* 7. 42.9 37.7 4 40 MAYHTR1A10BKR* 10.9 49 60 0 MAYHTR1A1BKR* 1.9/26.1 49/22.6 60/ 0/2 MAYHTR1A20BKR* 20.9/2.1 49/4.2 60/60 0/0 Note: Factory set at Medium High Speed. Motor Speed 0(0) AIR FLOW PERFORMANCE M4AH4E37B1B00AA External Static Pressure-Inches W.C. (kpa) 0.1(.02) 0.2(.0) 0.3(.07) 0.4(.10) 0.(.12) 0.6(.1) 0.7(.17) 0.8(.20) 1 2 3 898 1026 1161 72 902 1114 603 810 102 11 694 992 40 6 893 360 44 82 1 490 768 29 409 694 203 366 646 4 1287 1244 1186 1142 1078 969 914 892 893 1491 1442 1396 1348 12 1243 110 1088 1029

Mechanical Specifications Unique Cabinet Design - Metal shell and glass cotton thermal insulation layer Multi-Position UP/Down Flow Horizontal Left /Right Braze in Refrigerant Connection Primary/Secondary Condensate Connections Blower with Integrated Slide Deck for Easy Removal Inner-groove aluminum tube and high-efficiency aluminum fin Coil with Integrated Slide Deck for Easy Removal More auxiliary Electric Heaters optional ECM Speed Motor High Efficiency Integrated Horizontal Drain pans and metal Vertical Drain Fused 24V Power -Year Warranty. 10-Year Warranty Registered. Warranty Mirrors Outdoor. Optional extended warranty available. Ameristar The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.

Ameristar TAG: M4AH4E61B1C00AA SUBMITTAL.0 Ton Multi-position Air Handler M4AH4E61B1C00AA ELECTRICAL CONNECTIONS MAY EXIT TOP OR EITHER SIDE NOTE: 2 CLEARANCE IS REQUIRED IN THE FRONT OF THE UNIT FOR FILTER AND COIL MAINTENANCE. SUPPLY AIR HIGH VOLTAGE CONNECTION 7/8, 1-3/8, 1-3/4 DIA KNOCK OUTS FLANGES ARE PROVIDED FOR FIELD INSTALLATION 10 16 A W LOW VOLTAGE CONNECTION BREAKER SWITCH (FOR ELECTRIC HEATER ONLY) H VAPOR LINE CONNECTION COPPER (SWEAT) LIQUID LINE CONNECTION COPPER (SWEAT) D PRIMARY DRAIN CONNECTION 3/4 UPFLOW UNIT SHOWN; UNIT MAY BE INSTALLED UPFLOW, DOWNFLOW, HORIZONTAL RIGHT, OR LEFT AIR SUPPLY. NOTE: All dimensions are in mm/inches. Model H W D A M4AH4E61B1C00AA 138 (4-1/ 2) 60 (22) 610 (24) 496 (19-1/2)

PRODUCT SPECIFICATIONS PRODUCT SPECIFICATIONS MODEL M4AH4E61B1C00AA RATED VOLTS/PH/HZ. 208-2/1/60 RATINGS INDOOR COIL Type See O.D. Specifications Plate Fin Rows F.P.I. 4-17 Face Area (sq. ft.) 6.00 Tube Size (in.) 9/32 Refrigerant Control Orifice Drain Conn. Size (in.) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN Type Centrifugal Diameter-Width (In.) 10-/8 X 10-3/4 No. Used 1 Drive - No. Speeds Direct - vs. in. w.g. See Fan Performance Table No. Motors H.P. 1-3/4 Motor Speed R.P.M. 100 Volts/Ph/Hz 208-2/1/60 F.L. Amps 4. FILTER Filter Furnished? No Type Recommended Throwaway No.-Size-Thickness 1-20 X 22-1 in. REFRIGERANT R-410A Ref. Line Connections Brazed Coupling or Conn. Size in. Gas 7/8 Coupling or Conn. Size in. Liq. 3/8 DIMENSIONS H x W x D Crated (In.) -4/ x 2 x 27-7/10 Uncrated 4-1/2 x22 x 24 WEIGHT Shipping (Lbs.)/ Net (Lbs.) 177/19 Heater Kit Model Used Electric Heat (kw) Min. Circuit Ampacity Max. Fuse or Breaker (HACR) Ampacity 240V 208V 240V 208V Minimum Heating Blower Speed Without HP With HP MAYHTR1A0BKR* 31.8 28.3 40 MAYHTR1A08BKR* 7. 44.8 39.6 4 40 MAYHTR1A10BKR* 10 7.8 0.9 60 60 MAYHTR1A1BKR* 1 7.8/26.1 0.9/22.6 60/ 60/2 MAYHTR1A20BKR* 20 7.8/2.1 0.9/4.2 60/60 60/0 Note: Factory set at Medium High Speed. Motor Speed 1 2 3 4 0(0) 1344 187 2021 1284 1822 1967 AIR FLOW PERFORMANCE 1226 111 1774 1924 M4AH4E61B1C00AA External Static Pressure-Inches W.C. (kpa) 0.1(.02) 0.2(.0) 0.3(.07) 0.4(.10) 0.(.12) 0.6(.1) 1729 1879 1076 1677 1828 946 1629 178 904 1742 0.7(.17) 1694 0.8(.20) 893 869 131 1477 1418 1366 1299 1239 1138 1064 1001 1647 192 138 1490 1436 1378 131 121 1140 181 133 1473 1641

Mechanical Specifications Unique Cabinet Design - Metal shell and glass cotton thermal insulation layer Multi-Position UP/Down Flow Horizontal Left /Right Braze in Refrigerant Connection Primary/Secondary Condensate Connections Blower with Integrated Slide Deck for Easy Removal Inner-groove aluminum tube and high-efficiency aluminum fin Coil with Integrated Slide Deck for Easy Removal More auxiliary Electric Heaters optional ECM Speed Motor High Efficiency Integrated Horizontal Drain pans and metal Vertical Drain Fused 24V Power -Year Warranty. 10-Year Warranty Registered. Warranty Mirrors Outdoor. Optional extended warranty available. Ameristar The manufacturer has a policy of continuous product and product data improvement and it reserves the right to change design and specification without notice.