RHC GAS FIRED HEATING COILS

Similar documents
RHC & RHCE gas fired heating coils

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. DF / IDF Series GAS FIRED COMBINED HEATING AND VENTILATION

DF-IDF air handling units

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

... DF / IDF Gas fired combined heating and ventilation ...

PREEVA air handling unit

AMBIRAD.... Vision Radiant Tube Heating Systems...

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

VSX models 15% more effective than standard radiant tube heaters,with payback of 6 months achievable when redeeming ECA allowances.

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

The ultimate in air handling units: directly and indirectly fired

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

Gas-fired unit heaters for indoor installation

The ultimate in air handling units: directly and indirectly fired

Metropolitan. Steam Boiler. Suitable for Pressure Jet or Rotary Cup burners Oil, gas or dual fuel firing. Outputs kg/h

... UDSA - UDSBD Gas fired unit heaters...

STOKVIS R40 EVOLUTION RANGE. High Efficiency Fully Condensing Ultra Low NOx Wall Mounted Gas Fired Boilers

Application instructions

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

Euron. Compact Wall Mounted Gas Fired Condensing Boilers and Combis with Outputs 24kW - 30kW BOILERS

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

BENSON.... Variante3 Fired Unit Heaters...

CITY OPEN - CITY BOX from 25 to 35 kw

AGUAdens TM 100% residential condensing D.H.W. wall-mounted water heaters ( litres) AISI 316 D.H.W. WORKING PRESSURE TITANIUM CONDENSING

... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

Liquid Desiccant Air Conditioning Systems

Ethos Range High Efficiency Domestic Boilers. Combination Boilers Condensing Combination Boilers Condensing System Boilers

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

ALKON CARGO. A precise and fast delivery rate. A very high specific flow rate (20 litres per minute with Dt 25)

Heat pump and energy recovery systems

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

CONTENTS. Page 1. THE DRYPAC SYSTEM - CUSTOM MADE 1 2. PRINCIPLE OF OPERATION 2 3. CONTROLS 4 4. FLEXIBILITY 6 5. DRYPAC OPTIONS 7

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

24/31-28/35-33/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus.

LBF RANGE BALANCED FLUED WATER HEATERS

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

5 YEAR GUARANTEE. Inovia. High efficiency condensing combi and system boilers

24/31-28/35-32/40 kw Premix System Condensing Combi Gas Boilers. Priwa / PriwaPlus

thermocompact High performance system boiler range

Biomass. Biomass solid fuel boiler range

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

CP+ Gas & Oil Cabinet Heater Range

Warm air heating equipment

PRODUCT DATA COMPACT P - SERIES BY NILAN. Sanitary hot water production. Heating. Ventilation < 300 m 3 /h. Passive heat recovery.

... RTU. Packaged Air to Air Heat Pump...

hxi High Efficiency Heating Only 24hxi hxi High Efficiency Heating Only 30hxi hxi High Efficiency Heating Only 38hxi

Cooling with compressed air partial flow: the Heat Regenerating Adsorption Dryer EVERDRY FRP

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

UltraOil Condensing Oil Boiler

GHP AWO 38 Technical overview

Premium Efficiency Heat Recovery Unit. D-AHU Modular L. Air Handling Units

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

I] WHAT IS INFRARED? SW C FMW C MW C LW- upto 650 C

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Heat Recovery Units. Heat Recovery 1

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

Aegean Range. A new range of fan coils for heating and cooling commercial applications

product Industrial burners Industrial burners sizes 30 to 70 flexible and reliable Information on oil, gas and dual fuel burners

Cast Iron Boilers. G Series ( kW)

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Bosch Commercial and Industrial Heating High efficiency steam boilers (175kg/h to 55,000kg/h)

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

RGE 13 A T - 1 A


GAS ABSORPTION HEAT PUMP

TSEK VHR EC HEAT RECOVERY UNITS

24-28 kw Conventional Combi Gas Boiler. Lawa / LawaPlus

RAYPAK HOT WATER & HEATING

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

24/31-28/35-33/40 kw Premix System Condensing - ErP Combi Gas Boilers. Enerwa / EnerwaPlus.

RAYPAK HOT WATER & HEATING

Heat Recovery Air Handling Units

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Sirius FS. Working towards a cleaner future

unvented indirect & sealed heating systems unvented direct system & electric space heating Hot and cold water supply to all outlets at mains pressure

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

IPAC. Invicta Precision Air Control Floor Standing Range

5 YEAR ADVANCE PLUS WARRANTY. High efficiency condensing combi and system boilers

wall-mounted boilers, water heaters and pool heaters from 15 kw to 140 kw

Worcester GB162 wall mounted gas-fired condensing boiler series

WOLF GAS CONDENSING BOILERS COMFORTLINE

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

kw. Flexair. General description. Main components. CLIMATIC controller. Air cooled rooftop packaged unit

VORTEX BLUE OIL RANGE

New Zealand Sales Hotline: Sales Fax:

Transcription:

CI/SfB 56.83 X RHC GS FIRED HETING COILS

RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired heating section. They may also be used for replacing steam and hot water coils in existing units and plenum systems to enable changeover from central boiler plant to decentralised gas fired systems. The units also provide an ideal heating module for installation in ductwork systems for HVC installations and a variety of industrial applications including drying and curing. Features High efficiency units qualify for enhanced capital allowances pplication flexibility all units can accommodate both vertical and horizontal airflows Choice of controls close temperature control on/off, high/low or modulating Longer life heat exchanger tubes are expanded into a collection box, eliminating welds. They are available with a choice of stainless steel or aluminised steel tubes Low cost simple installation reduces costs Optimum choice 6 different tube lengths offer the designer a wide choice to suit the air handling unit profile Model Range comprehensive range of units with heat outputs from 11kW to 900kW and a wide choice of dimensions offer the designer maximum flexibility. Where higher heat outputs are required modules can be placed side by side with right hand and left hand access to satisfy heat requirements up to 1800kW. The units are available for either indoor applications (DJL option) or outdoor applications (RJL option). RHC 4000 Four pass heat exchanger Minimum 91% high thermal efficiency Heat outputs from 11kW to 200kW per module Modular monobloc units up to 400kW RHC 8000 Two pass heat exchanger Minimum 91% high thermal efficiency Heat outputs from 30kW to 300kW per module Modular monobloc units up to 900kW Optional air diffuser for low airflow applications Special combinations up to 2400kW are also available. Please consult Reznor

Energy Efficiency The gas fired heating coils provide 91% minimum thermal efficiencies directly at the point of use thereby eliminating the distribution and standby losses normally associated with central boiler plant. Optimised energy usage and reduced running costs result from: High turn down ratio Instant response to changing conditions Reduced pre-heat period Elimination of residual thermal mass on plant shut down CE Certification ll heating coils are fully CE certified and are supplied with comprehensive fitting instructions. The RJL coils are provided complete with a matched flue terminal and air inlet which have been tested and CE certified against the effect of wind attack. Each unit is fully test-fired prior to despatch; optional on-site commissioning and full after sales service is available through a nationwide network of in-house service engineers. Reduced Installation Costs The application of gas fired heating coils directly at the point of use eliminates the need for a central boiler plant with all the associated costs and space requirements for the plant room, boiler, pumps, pipework and insulation. Gas fired heating coils also remove the risk of freezing and subsequent costs of frost protection for the heating coils and pipework, a factor which is particularly relevant for external or rooftop units. Simple Installation The heating coils are designed for fast and simple installation and only require coil slides for incorporation within an ir Handling Unit. The coils are designed to allow the specifier a choice of cross section dimensions for each heat output to allow close matching to cooling coil sizes and the aspect ratio of the HU. For reduced pressure drop and optimised specific fan power, an integral bypass can be incorporated within the coil framework. factory fitting service is also available to install the heating coils into free issue sections. lternatively the coils can be supplied as a complete heater section for fitting into ductwork systems or industrial process applications. irflow Direction The heating coils may be used in either a horizontal or vertical configuration and are suitable for various airflow directions. Enhanced Capital llowances (EC) The Government s Enhanced Capital llowance scheme actively encourages industry and commerce to reduce energy consumption by promoting the use of energy efficient equipment. The RHC coils are Energy Technology Listed to allow qualifying end users to claim enhanced capital allowances. This symbol verifies that the product has been independently assessed and qualifies for the EC scheme, an upfront tax relief enabling businesses that invest in energy-saving equipment to claim 100% first-year capital allowances against their taxable profits.

RHC GS FIRED REZNOR HETING COILS The dvantages of Gas Fired Heating Coils RHC Gas Fired Heating Coils Single coils provide a turndown ratio of approx 4:1 whilst modular monobloc units with higher heat outputs can provide a turndown ratio of up to 24:1. Multi-try ignition system with full safety sequence control provides additional reliability. Monobloc modular format eliminates the possibility of total loss of heating as a result of a single component failure. Comprehensive choice of coil dimensions allows units to be closely matched to the HU size, to maintain uniform air flow with reduced pressure loss. Modular format ensures close matching to heat demand for optimum energy efficiency. RHC coils for external units are supplied complete with CE certified combustion air inlets and flue terminals. Fan assisted flue allows for smaller flue diameters with option for balanced flue wall terminals. Utilising the full height of the HU allows the design of the heating coil to be very compact and can significantly reduce the length of the HU to save cost, space and weight. Lower operating temperature and even heat distribution provide enhanced life expectancy. The heating coils provide very even heating across the face of the coil and operate at a maximum surface temperature of 450 C. The lower surface temperature reduces radiant heat to the structure of the HU and surrounding components. Radiation shields fitted around the coils eliminate the need for additional shields and optimise heat transfer into the air-stream. Traditional Gas Fired Heat Exchangers Fixed dimensions of traditional heat exchangers result in transformation sections often being required, with resultant increased pressure drop. Lower thermal efficiency, circa 82% on traditional gas fired heat exchangers. Higher operating temperatures, typically up to 650 C, results in increased thermal stress and heat radiation to HU frame and components. Increased length adds to cost and weight of unit while also increasing space requirements. Total loss of heating capacity in the event of a single component failure on main burner.

Monobloc Units Up to three modules can be supplied assembled as a single monobloc to provide heat outputs up to 900kW. Monobloc modules may be installed side by side to increase heat outputs up to 1800kW. Special combinations up to 2400kW are also available, please consult Reznor. The monobloc units combine high thermal efficiency with an excellent turndown ratio of up to 24:1, depending on the output and control system selected, to optimise energy usage. The modular approach provides improved reliability, allowing large heat output units to be utilised without the risk of loss of total heating on failure of a single component. Where higher airflows are required a top or side bypass can be incorporated to minimise the pressure drop through the heating coil. Monobloc Triple Unit Monobloc Twin Unit Optional Control Vestibules Units are also available with an enclosed control vestibule. The flanged vestibule allows the width of the ir Handling Unit to be minimised with the control vestibule projecting outside. The vestibules may be specified for either internal or outdoor units. Outdoor vestibules are supplied complete with flue termination and combustion air inlet. Vestibules have a durable powder coat finish to RL 7035, other colours are available on request. Higher airflow units may be fitted with a side bypass to minimise the pressure drop through the heating coil. Top bypass arrangement is not available for units fitted with a vestibule. Units supplied complete with controls vestibule are also ideal for applications where the heat module is to be installed into ductwork. RJL Model External pplication DJL Model Internal pplication

RHC 4000 GS FIRED REZNOR HETING COILS C B 380 DIMENSION DT Model 4011.03 4015.04 4018.05 4024.05 4030.06 4036.08 Height mm 305 458 458 559 559 837 Width B mm 547 547 547 677 677 677 Depth C mm 590 590 590 648 648 648 TECHNICL DT Model 4011.03 4015.04 4018.05 4024.05 4030.06 4036.08 Nominal heat output kw 11 15 18 24 30 36 Natural gas consumption 1 m 3 /h 1.26 1.68 2.10 2.79 3.49 4.20 LPG consumption 1 kg/h 0.94 1.26 1.57 2.10 2.61 3.14 Gas connection 2 Rc ¾ ¾ ¾ ¾ ¾ ¾ Flue diameter (RJL) mm 100 100 100 100 100 100 Flue / combustion air diameter (DJL) mm 80 80 100 100 100 130 Electrical consumption (230V 1Ph 50 Hz) kw 0.153 0.153 0.153 0.153 0.153 0.153 Net weight kg 20 25 30 45 53 70 Minimum airflow 3 (standard unit) m 3 /h 1465 1940 2270 2880 3290 5281 Pressure drop @ minimum airflow Pa 15 15 15 20 15 25 Maximum airflow 3 m 3 /h 4100 5400 6350 8000 9200 11650 Note: 1. Natural gas G20 calorific value 10.48kW/m 3 GCV. Propane G31 calorific value 14.0kW/kg GCV. 2. Not supply line size. 3. Please consult Reznor for pressure drop data where more than one module is used in series.

C B D DIMENSION DT Model 4050.06 4060.07 4075.09 4100.12 4110.13 4125.15 4150.18 4175.21 4200.24 Height mm 531 601 741 950 1132 1272 1481 1691 1900 Width B mm 1049 1049 1049 1049 1049 1049 1049 1049 1049 Depth C mm 800 800 800 800 930 930 930 930 930 Control compartment D mm 400 400 400 400 420 420 420 420 470 TECHNICL DT Single Module 4050.06 4060.07 4075.09 4100.12 4110.13 4125.15 4150.18 4175.21 4200.24 Nominal heat output kw 50 60 75 100 112 125 150 175 200 Natural gas consumption 1 m 3 /h 5.92 7.12 8.73 11.45 13.02 14.63 17.44 20.19 22.94 LPG consumption 1 kg/h 4.43 5.33 6.53 8.57 9.60 10.78 12.85 14.88 16.91 Gas connection 2 Rc ¾ ¾ ¾ ¾ 1¼ 1¼ 1¼ 1¼ 1¼ Flue diameter (RJL) mm 100 100 100 100 130 130 130 130 130 Flue / combustion air diameter (DJL) mm 130 130 130 130 130 130 130 130 130 Electrical consumption (230V 1Ph 50 Hz) kw 0.153 0.153 0.153 0.153 0.282 0.282 0.282 0.282 0.960 Net weight kg 90 100 120 149 200 220 250 279 313 Minimum airflow (standard unit) m 3 /h 3900 4700 5700 7500 8600 9600 12300 14100 16300 Pressure drop @ minimum airflow Pa 40 40 37 40 70 68 44 43 44 Twin Module 4050.06 4060.07 4075.09 4100.12 4110.13 4125.15 4150.18 4175.21 4200.24 Nominal heat output kw 100 120 150 200 224 250 300 350 400 Minimum airflow (standard unit) m 3 /h 5950 7150 8800 11700 13600 15600 17500 20600 23300 Pressure drop @ minimum airflow Pa 150 150 150 156 352 359 178 189 165 Note: 1. Natural gas G20 calorific value 10.48kW/m 3 GCV. Propane G31 calorific value 14.0kW/kg GCV. 2. Not supply line size. Table for twin modules shows total heat output and airflow data. For gas consumption and flue connections please multiply single module data as appropriate.

RHC 8000 GS FIRED REZNOR HETING COILS 400 1244 400 DIMENSION DT Model 8030.06 8045.09 8060.12 8075.15 8090.18 Height mm 531 741 950 1160 1369 TECHNICL DT Single Module 8030.06 8045.09 8060.12 8075.15 8090.18 Nominal heat output kw 30 45 60 75 90 Natural gas consumption 1 m 3 /h 3.53 5.34 7.12 8.72 10.48 LPG consumption 1 kg/h 2.64 4.00 5.33 6.43 7.72 Gas connection 2 Rc ¾ ¾ ¾ ¾ ¾ Flue diameter (RJL) mm 100 100 100 130 130 Flue / combustion air diameter (DJL) mm 100 130 130 130 130 Electrical consumption (230V 1Ph 50 Hz) kw 0.153 0.153 0.153 0.153 0.153 Net weight kg 60 87 120 140 160 Minimum airflow (standard unit) m 3 /h 4400 6600 8750 11900 14300 Pressure drop @ minimum airflow Pa 40 40 40 40 40 Maximum airflow with optional diffuser plate m 3 /h 3750 5650 7500 9300 11200 Pressure drop with diffuser plate Pa 85 90 90 85 90 Twin Module 8030.06 8045.09 8060.12 8075.15 8090.18 Nominal heat output kw 60 90 120 150 180 Minimum airflow (standard unit) m 3 /h 4400 6600 8750 11900 14300 Pressure drop @ minimum airflow Pa 70 70 70 70 70 Maximum airflow with optional diffuser plate m 3 /h 3750 5650 7500 9300 11200 Pressure drop with diffuser plate Pa 90 100 100 100 100 Triple Module 8030.06 8045.09 8060.12 8075.15 8090.18 Nominal heat output kw 90 135 180 225 270 Minimum airflow (standard unit) m 3 /h 5250 7850 10500 13000 15800 Pressure drop @ minimum airflow Pa 135 140 145 140 145 Note: 1. Natural gas G20 calorific value 10.48kW/m 3 GCV. Propane G31 calorific value 14.0kW/kg GCV. 2. Not supply line size. Table for twin and triple modules shows total heat output and airflow data. For gas consumption and flue connections please multiply single module data as appropriate.

C 1844 D DIMENSION DT Model 8050.06 8075.09 8100.12 8125.15 8150.21 8175.21 8200.24 Height mm 531 741 950 1272 1481 1691 1900 Depth C mm 400 400 400 400 400 400 530 Control compartment D mm 400 400 400 420 420 420 550 TECHNICL DT Single Module 8050.06 8075.09 8100.12 8125.15 8150.21 8175.21 8200.24 Nominal heat output kw 50 75 100 125 150 175 200 Natural gas consumption 1 m 3 /h 5.92 8.73 11.45 14.63 17.44 20.19 23.28 LPG consumption 1 kg/h 4.43 6.53 8.57 10.78 12.85 14.88 17.16 Gas connection 2 Rc ¾ ¾ ¾ 1¼ 1¼ 1¼ 1¼ Flue diameter (RJL) mm 100 100 100 130 130 130 130 Flue / combustion air diameter (DJL) mm 130 130 130 130 130 130 130 Electrical consumption (230V 1Ph 50 Hz) kw 0.153 0.153 0.153 0.282 0.282 0.282 0.960 Net weight kg 80 110 145 200 230 265 300 Minimum airflow (standard unit) m 3 /h 7150 10750 14300 18000 21000 21500 24000 Pressure drop @ minimum airflow Pa 50 50 50 50 50 45 40 Maximum airflow with optional diffuser plate m 3 /h 6200 9300 12400 15600 18200 18650 20900 Pressure drop with diffuser plate Pa 100 112 112 100 100 80 80 Twin Module 8050.06 8075.09 8100.12 8125.15 8150.21 8175.21 8200.24 Nominal heat output kw 100 150 200 250 300 350 400 Minimum airflow (standard unit) m 3 /h 7150 10790 14300 18000 21000 21500 24000 Pressure drop @ minimum airflow Pa 80 100 100 90 90 70 65 Maximum airflow with optional diffuser plate m 3 /h 9200 9300 12400 15600 18200 20100 23300 Pressure drop with diffuser plate Pa 100 125 125 125 125 125 150 Triple Module 8050.06 8075.09 8100.12 8125.15 8150.21 8175.21 8200.24 Nominal heat output kw 150 275 300 375 450 525 600 Minimum airflow (standard unit) m 3 /h 8750 13000 17000 22000 26000 30000 35000 Pressure drop @ minimum airflow Pa 170 190 190 180 180 180 190 Note: 1. Natural gas G20 calorific value 10.48kW/m 3 GCV. Propane G31 calorific value 14.0kW/kg GCV. 2. Not supply line size. Table for twin and triple modules shows total heat output and airflow data. For gas consumption and flue connections please multiply single module data as appropriate.

RHC 8000 GS FIRED REZNOR HETING COILS 600 2435 550 DIMENSION DT Model 8225.18 8250.20 8275.22 8300.24 Height mm 1912 2078 2244 2410 TECHNICL DT Single Module 8225.18 8250.20 8275.22 8300.24 Nominal heat output kw 225 250 275 300 Natural gas consumption 1 m 3 /h 25.8 28.7 31.6 34.5 LPG consumption 1 kg/h 19.3 21.5 23.6 25.8 Gas connection 2 Rc 1¼ 1¼ 1¼ 1¼ Flue diameter (RJL) mm 130 130 130 130 Flue / combustion air diameter (DJL) 3 mm 150 150 150 150 Electrical consumption (230V 1Ph 50 Hz) kw 0.960 0.960 0.960 0.960 Net weight kg 487 501 516 530 Minimum airflow (standard unit) m 3 /h 33600 37200 40800 43800 Pressure drop @ minimum airflow Pa 40 40 40 40 Maximum airflow with optional diffuser plate m 3 /h 22800 25200 27600 29700 Pressure drop with diffuser plate Pa 35 35 35 35 Twin Module 8225.18 8250.20 8275.22 8300.24 Nominal heat output kw 450 500 550 600 Minimum airflow (standard unit) m 3 /h 34000 37500 41000 44000 Pressure drop @ minimum airflow Pa 75 75 75 75 Maximum airflow with optional diffuser plate m 3 /h 29000 29000 35500 38500 Pressure drop with diffuser plate Pa 80 70 80 80 Triple Module 8225.18 8250.20 8275.22 8300.24 Nominal heat output kw 675 750 825 900 Minimum airflow (standard unit) m 3 /h 39000 44000 47500 52500 Pressure drop @ minimum airflow Pa 150 155 155 155 Note: 1. Natural gas G20 calorific value 10.48kW/m 3 GCV. Propane G31 calorific value 14.0kW/kg GCV. 2. Not supply line size. 3. For 150mm diameter flue, consult Reznor. Table for twin and triple modules shows total heat output and airflow data. For gas consumption and flue connections please multiply single module data as appropriate.

Balanced Flue Terminals C E E G D F C D B F G B FLUE DIMENSIONS Model Vertical Roof Terminal Horizontal Wall Terminal 80mm 100mm 130mm 80mm 100mm 130mm mm 1290 1380 1850 780 780 800 B mm 130 140 225 130 140 225 C mm 165 165 220 80 100 133 D mm 150 150 200 125 150 200 E mm 500 550 630 540 540 610 F mm 530 600 1220 380 380 460 G mm 170 230 340 170 220 340 Maximum wall thickness mm n/a n/a n/a 370 370 420 Note: For 150mm diameter flue, consult Reznor (8225-8300 DJC models only) Typical Flue rrangements RJL modules for installation in external or rooftop units are CE certified complete with combustion air inlet hoods and flue terminals (supplied loose). For installation in naturally ventilated plant rooms DJL modules may be conventionally flued. Where plant rooms are sealed or subject to negative pressure, a range of matching balanced flue terminals and sealed pipework is available.

Heat Recovery wide range of heat recovery heat exchangers and thermal wheels for incorporating within air handling units and other air systems is also available from Reznor UK. Cross Plate Heat Exchangers new generation of recuperative plate heat exchanger, designed for incorporation into air handling units or as part of an air distribution system. Cross plate heat exchangers provide complete separation between the exhaust and fresh air streams. Counterflow Heat Exchangers new generation of high efficiency plate heat exchangers with extended heat exchange area. The counterflow heat exchangers offer very high efficiency heat recovery in excess of 80% for typical HVC applications and offer a viable alternative to rotary heat exchangers for lower airflow applications. Rotary Heat Exchangers The highest form of thermal energy recovery in air handling systems, rotary heat exchangers deliver high efficiencies with high air volumes in limited space. They are a well proven means of energy recovery, normally recovering up to 80% in typical HVC applications. Desiccant Enthalpy Dehumidification Rotors The desiccant rotor is a further development of the traditional energy recovery rotor. The matrix has a very high capacity for moisture absorption. It absorbs moisture from the air which flows through the matrix and transfers the moisture as the wheel rotates. The desiccant rotor is ideal for total energy recovery and dehumidification with or without additional regeneration air heating. Document reference number: GB/WR/011/1208 Reznor UK Limited Park Farm Road Folkestone Kent CT19 5DR United Kingdom Telephone: 01303 259141 Facsimile: 01303 850002 Email: marketing@reznor.co.uk Website: www.reznor.co.uk Reznor UK is a registered trademark of mbirad Limited. Because of continuous product innovation, mbirad reserves the right to change product specification without due notice.