Introducing Corcom CU Series 1U Height Power Entry Modules

Similar documents
Introducing Corcom DB Series

Quick Reference Guide.050 Centerline Micro-MaTch Connector Series

Introducing Hermaphroditic Blade and Receptacle Connector

Introducing Low Voltage DC Grid Interconnects

Quick Reference Guide Barrier Strips

Introducing SlimSeal SSL Connector

Introducing Solar Identification Labels

Introducing Inverted SMT Thru Board Connector

Pin, Spool & Strain Insulators

PlanarMag Product Technology

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

CII FCAC-150 Series Relay

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Z-PACK TinMan 85 ohm Connector Overview

SOLARLOK Interconnection System Installation Manual

AMP SUPERSEAL 1.5 SERIES Connectors

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Universal Connectivity Platform A Modular Approach to Infrastructure Design

RoHS. Ready. KILOVAC LEV100 Series 900 Vdc Contactor DESCRIPTION KEY FEATURES

Standard and Customized Hand Tool Kits

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

Gas Discharge Tubes GTCX25-XXXM-R02 Series

AXICOM Telecom-, Signal and RF Relays. Cradle Relay Accessories and Mounting Nov. 07 Rev. C ECOC: JM10

Gas Discharge Tubes. Features: Benefits: Applications:

DIP Switches Series. Performance Characteristics Series. Materials. Technical Documents

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

KILOVAC K1K High-Voltage Contactor

Quick Reference Guide: Connectors for Mobile Devices

Gas Discharge Tubes GTCX28-XXXM-R05 Series

Reliable solutions for electrified railway systems

TE Connectivity's AMP NETCONNECT Cable Management

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Universal Connectivity Platform

RAYCHEM MEDIUM VOLTAGE

DEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

HARTMAN Smart AC Contactors

QUADRAX D-SUB CONNECTORS

WILDLIFE AND ASSET PROTECTION PRODUCTS

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

DATASHEET PolySwitch RKEF Devices

S200 SHIELD TERMINATORS

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

MODEL 834M1 ACCELEROMETER

Signal Connectors for Topside and Subsea Applications

Lead Makers and Harness Makers

MODEL ACCELEROMETER

BUDI-M-SP. Building distributor. Introduction. Seals. Kit content. Accessories. Wrap around cable seals

Application Specification MAG-MATE* Poke-In Tab Terminals

Wire and Cable The Industry Standard for Rugged, Reliable Performance

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

Series TY-B & TY-FRB, 10 mm Orifice, ISO 7/1-R3/8 Upright, Pendent, and Recessed Pendent Sprinklers Standard and Quick Response General Description

High Density Optical In-Line Dry-Mate Connector (ILC) High Performance Multichannel Fiber Optic Connectors

AT&T Switched Ethernet on Demand

Series TY-FRL 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Quick Response, Standard Coverage General Description

FIST-EDSA-D4. 3 Feeder cable/ducts (max 16 mm) 4 Drop cable (DB cable or guiding tubes 5-8 mm) 5 Adding drop cable. 6 Gel part replacement

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

/Oct/2014 Rev B

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

/Oct/2014 Rev E

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

Cat 6 Shielded Patch cords

Open-area Smoke Imaging Detector. Engineering Specification

Vertical Mounting of Kaleidescape Components

Universal Retention Modules 02 MAR 10 Rev A

Your Pick... One Solution

Tether and Umbilical Cables for Remotely Operated Vehicles

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

RA889A Switching Relay

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

6600 SERIES 8-Pin DIP, Subminiature Bimetal Disc Thermostat

MODEL 4000A & 4001A ACCELEROMETER

YOUR PORTABLE AIR PURIFIER

INSTRUCTIONS REHAU SILENT DIAL THERMOSTAT #

Cat 6 Unshielded Patch cords

PolySwitch Surface-Mount Resettable Fuses

Specification Status: Released

PT9420 (Extended Range)

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

NECTOR S Line lighting components. Flexible solutions for your lighting designs

Inverted Through Board Surface

Series TY-B 2.8, 5.6, and 8.0 K-factor Upright, Pendent, and Recessed Pendent Sprinklers Standard Response, Standard Coverage General Description

Cable Actuated Sensor Industrial Incremental Encoder Output

HydroSpeed plate washer for 96- and 384-well formats

Mar11 Rev B

LED RETROFIT CONVERSION KITS

SGJ. 80, 120-inch Stroke Range Options. Polycarbonate Enclosure IP67. In Stock for Quick Delivery. General. CANbus Specifications

ES2-HB. Ordering Information. Dimensions. Specifications. Humidity Sensor Temperature/Humidity Sensor

Transcription:

Introducing orcom U Series 1U Height Power Entry Modules

orcom U Series 1U Height Power Entry Modules KEY ETURES ompact 1U (1 3/4 ) Design 115* iltered and Unfiltered SPST Switch Shrouded Quickonnect Terminals Various Mounting Styles Lower Power Dissipation Higher System Efficiency Lower ooling Demand Underwriters Laboratories Recognized, S ertified and VDE pproved* * 15 versions tested by Underwriters Laboratories to US and anadian requirements and are VDE approved at 10 @ 250 V. Description The U series joins the orcom product family of Power Entry Modules, filling the need for smaller versions of our switched inlet filters and unfiltered power inlets. This series provides power entry for equipment designed for popular 1U (1 3 /4 ) height equipment racks. The filtered versions provide complete shielding, shrouded quick connect terminals and basic filtering for 1 to 15 applications, in an extremely compact size. The design is available in snapin and flanged mounting options. iltered versions are also available in a new rear mount style which provides a flush appearance with enhanced EMI shielding. The unfiltered inlet snapin versions are available in three different configurations to fit a wide vareity of panel cutouts and thicknesses and with optional preconnected terminals from the socket to the switch. The U Series features a common IE 603201 14 power inlet for international compatibility. Refer to the, GG, P, and M Series PEMs for applications requiring additional features. PPLITIONS Rack mounted equipment, telecom, consumer electronics, power supplies, routers, Ps, TVs, lighting, imaging equipment, settop boxes and other applications with limited panel space. STNDRD ND SPES Maximum Leakage current, each line to ground (filtered models only) : @120 V 60 Hz :.25 m and @ 250 V 50 Hz:.40 m Hipot rating (one minute) : linetoground 1500 V, linetoline 1450 VD Operating requency : 50/60 Hz Rated Voltage : 250 V Rated currents : 1, 3, 6, 10, 15 Operating Voltage : 120/250 V Switch : Single pole single throw Terminal Pushon orce : 15 lb / 67 N (max) Electrical Schematics Line Load Tyco Electronics I orcom U Series 1U Height Power Entry Modules

PRODUT OERING : Part numbers iltered Versions Unfiltered Versions 1UE1 3UE1 6UE1 10UE1 15UE1 1US1 3US1 6US1 10US1 15US1 1U1 3U1 6U1 10U1 15U1 15UE1 15U15S1 15U10S1 15US1 15UE1* 15U15S1* 15U10S1* 15US1* * Preconnected terminals ase dimensions Part Numbers UE1, UE1 US1, US1 U10S1, U10S1 U15S1, U15S1 UE1 US1 U1 (max) 1.73 43.90 1.73 43.90 1.70 43.10 (max) 0.96 0.97 0.97 0.97 1.75 44.50 1.80 45.00 1.80 45.00 (max) D ±0.004 ±0.100 1.06 26.90 1.04 26.40 1.05 26.70 1.05 26.70 1.11 28.10 1.11 28.10 1.21 30.80 E ±0.004 ±0.100 1.09 27.60 1.26 32.00 1.24 31.60 1.24 31.60 1.26 31.90 1.26 32.00 1.35 34.30 ±0.004 ±0.100 1.45 36.80 Panel Thickness NOTE : Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specification subject to change. 1.45 36.80 1.45 36.80.025.082 [0.63 2.1].028.039 [0.7 1.0].047.059 [1.2 1.5].025.082 [0.63 2.1].157 [4.0] Max Minimum insertion loss in db Linetoground in 50 ohm ircuit urrent Rating requency MHz.05.15 0.5 1 5 10 30 1 19 30 44 49 47 44 45 3 13 23 37 43 47 44 49 6 5 14 28 34 43 43 48 10 1 7 19 25 35 36 52 15 1 10 13 25 27 42 Linetoline in 50 ohm ircuit urrent Rating requency MHz.05.15 0.5 1 5 10 30 1 1 10 21 26 48 51 60 3 1 10 20 26 42 45 65 6 1 10 20 23 38 41 65 10 1 10 20 23 29 34 56 15 1 10 20 23 28 39 54

orcom U Series 1U Height Power Entry Modules SE DIMENSIONS cont. UE1 UE1 Preonnected Terminals Side View Rear View Line Inlet (1) : IE 603201 14 Load/Switch Terminals (5) :.188 [4.8] with.07 [1.8] Dia. hole US1 US1 Preonnected Terminals Line Inlet (1) : IE 603201 14 Load/Switch Terminals (5) :.188 [4.8] with.07 [1.8] Dia. hole Side View Rear View U10S1, U15S1 U10S1, U15S1 Preonnected Terminals Side View Rear View Line Inlet (1) : IE 603201 14 Load/Switch Terminals (5) :.188 [4.8] with.07 [1.8] Dia. hole Note : Switch output terminal configurations for any unfiltered version may vary from that shown here. Dimensions are not affected orcom U Series 1U Height Power Entry Modules I Tyco Electronics

SE DIMENSIONS cont. UE1 U1 Mounting holes (2) :.132 [3.35] Dia. with.260 [6.6] Dia. x 90 countersink for #4 or M3 flathead screw Line Inlet (1) : IE 603201 14 Load Terminals (2) :.188 [4.8] with.07 [1.8] Dia. hole US1 Mounting holes (2) : M3 x.5 Line Inlet (1) : IE 603201 14 Load Terminals (2) :.188 [4.8] with.07 [1.8] Dia. hole Line Inlet (1) : IE 603201 14 Load Terminals (2) :.188 [4.8] with.07 [1.8] Dia. hole Output Shroud, Inside dimension :.21 x.34 [5.2 x 8.6] Recommended panel cutout R. Max D Panel Thickness US1, US1.025.082 [ 0.63 2.1 ] U10S1.028.039 [ 0.7 1.0 ] U15S1.047.059 [ 1.2 1.5 ] E U1.157 [ 4.0 ] Max Note : R=1.8 [45.72] for U, 1.0 [25.4] for all others.

OR MORE INORMTION Technical Support orcom Phone 847.573.6597 Internet: www.tycoelectronics.com/help www.corcom.com Email: newproducts@tycoelectronics.com US: +1 (800) 5226752 anada: +1 (905) 4704425 Mexico & entral merica: +52(0) 5511060814 South merica: +55 (0) 1121036000 Germany: +49 (0) 62511331999 UK: +44 (0) 800867666 rance: +33 (0) 134208686 Netherlands: +31 (0) 736246999 hina: +86 (0) 4008206015 Tyco Electronics orporation Harrisburg, P tycoelectronics.com 2010 Tyco Electronics orporation. ll Rights Reserved. 17734551 IS PD 01/2010 orcom, TE (logo) and Tyco Electronics are trademarks of the Tyco Electronics group of companies and its licensors. Other products, logos, and ompany names mentioned herein may be trademarks of their respective owners. While Tyco Electronics has made every reasonable effort to ensure the accuracy of the information in this catalog, Tyco Electronics does not guarantee that it is errorfree, nor does Tyco Electronics make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. Tyco Electronics reserves the right to make any adjustments to the information contained herein at any time without notice. Tyco Electronics expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalog are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. onsult Tyco Electronics for the latest dimensions and design specifications.