1kW to 980kW WATER HEATERS 445 to 7520ltrs/hr ELECTRIC BOILERS ELECTRIC DOMESTIC HOT WATER HEATERS ABOUT ATLANTIC ATLANTIC BOILERS was formed in 1980 to promote highly efficient boilerplant and within two years had supplied the first commercial gas condensing boilers in the UK. For 35years we have supplied gas, oil, B100 bio-fuel, LPG and electric boilers and domestic hot water heaters to many types of building. Coupled with the supply, ATLANTIC BOILERS provides back-up commissioning, spares and servicing by way of a network of merchants throughout the UK. ATLANTIC BOILERS, PO BOX 11, ASHTON UNDER LYNE, OL6 7TR 0161 621 5960 info@atlanticboilers.com www.atlanticboilers.com
36-980kW MULTI-ELEC STANDARD ELECTRIC BOILER 17 Models: from 90kW to 630kW and up to 980kW by special order For closed heating systems Maximum Workng Pressure 4BARS Maximum flow temperature 110 C standard 95 C Series of 30kW or 35kW incoloy immersionheaters Made to IP21/IK08, Directive 2006/95/CEE & BS EN 60335-1, C73800 TYPICAL HEATING SYSTEM: Heating and domestic hot water systems, with weather compensation EXPRESSO BALANCING VESSEL Expansion Vessel Auto top-up system
Model 90 120 150 180 210 245 280 315 350 385 420 455 490 525 560 595 630 Maximum Output kw 90 120 150 180 210 245 280 315 350 385 420 455 490 525 560 595 630 No of Immersion heaters 4 4 5 6 6 7 8 9 10 11 12 13 14 15 16 17 18 Minimum flow rate l/sec 0.6 0.8 0.8 1.1 1.7 1.7 1.7 1.7 2.2 2.2 2.2 2.8 2.8 2.8 28.8 3.6 3.6 Maximum flow rate l/sec 5.0 5.0 10.0 10.0 11.7 11.7 11.7 11.7 11.7 11.7 11.7 26.0 26.0 26.0 26.0 26.0 26.0 Maximum pressure drop kpa 8 8 28 28 16 16 16 16 16 16 16 16 16 16 16 16 16 Flow/return connections 80 80 80 80 100 100 100 100 100 100 100 150 150 150 150 150 150 Dry weight kgs 117 121 125 129 233 238 243 248 253 258 263 367 372 277 382 387 392 Water contents litres 128 128 128 128 283 283 283 283 283 283 283 395 395 395 395 395 395 Depth mm 820 820 820 820 970 970 970 970 1070 1070 1070 1170 1170 1170 1170 1170 1170 Width mm 520 520 520 520 670 670 670 670 670 670 670 770 770 770 770 770 770 Height mm 1380 1380 1380 1380 1570 1570 1570 1570 1600 1600 1600 1800 1800 1800 1800 1800 1800 Access front mm 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 Access rear mm 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 750 Access side mm 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 500 Access other side mm 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 ELECTRICAL POWER REQUIREMENTS - 415 volts, 3 phase, 50Hz OUTPUT STEP ONE Power kw 30 60 60 60 70 105 105 105 140 140 140 175 175 175 210 210 210 Fuse amps 63 125 125 125 125 160 160 160 250 250 250 315 315 315 400 400 400 OUTPUT STEP TWO Power kw 30 30 60 60 70 70 105 105 105 140 140 140 175 175 175 210 210 Fuse amps 63 63 125 125 125 125 160 160 160 250 250 250 315 315 315 400 400 OUTPUT STEP THREE Power kw 30 30 30 60 70 70 70 105 105 105 140 140 140 175 175 175 210 Fuse amps 63 63 63 125 125 125 125 160 160 160 250 250 250 315 315 315 400 DETAILS OF CONTROLLER Components of the Multi-elec Compacte boiler Control panel Ventilation louvre Boiler heating flow Boiler flow sensor Boiler immersion heaters Thermal insulation Boiler heating return Main electrical power input Electric switch gear including 9 cartridge fuses, 3-step contactors, 1 control circuit transformer, indicator lamps and digital controller Digital temperature controller Main electrical isolating switch ACTON TOWN HALL The Acton Town Hall regeneration project has included the installation of a MULTI-ELEC 315kW electric boiler which overcame site problems of access and availability of services. Needing no flues, the powerful, over 99% GCV efficient boiler fitted snugly into a basement area. Requiring only electrical energy supplies, shortage of adequate natural gas was speedily overcome. The Multi-Elec is available, from 96kW to 630kW and, by special manufacture up to 980kW. Range of temperature is 40 C to 95 C, and working pressure 0.5BARS to 4.0BARS.
36-72kW MULTI-ELEC COMPACTE ELECTRIC BOILER 4 Models: 36kW/ 48kW / 60kW / 72kW For closed heating systems Maximum Workng Pressure 4BARS Maximum flow temperature 95 C Carbon Steel body, 50mm rockwool thermal insulation Made to IP21/IK08, Directive 2006/95/CEE & BS EN 60335-1, C73800 Model 36 48 60 72 Maximum Output kw 36 48 60 72 Amps per phase 56 75 94 112 Dry weight kg 120 122 124 126 Footprint mm 400mm x 600mm DIMENSIONS Depth mm 690 690 690 690 Width mm 410 410 410 410 Height mm 1240 1240 1240 1240 Access front mm 1000 1000 1000 1000 Access side1 mm 500 500 500 500 Access side 2 mm 100 100 100 100 Access back mm 500 500 500 500 Height 1240mm + 700 700 700 700 DETAILS OF CONTROLLER Step control lights Plus/minus temp settings ELECTRICAL POWER REQUIREMENTS - 415V, 3 PHASE, 50Hz COMPACT 36 48 60 72 STEP ONE Fuse amps 50 50 63 63 Power kw 24 24 36 36 STEP TWO Fuse amps 25 50 50 63 Power kw 12 24 24 36 85.3 C SET 2 Lock-out control or temperature defect SET 1 Step 1 and Step Step 2 settings control operation
+700 mm Immersion Heaters Boiler Sensors Pocket Control Panel Ventilation Flow 1240 mm On/Off Switch 915mm Insulation Insulation Electrical Components Return 163 mm 100mm 410mm 640mm TYPICAL HEATING SYSTEM: Conventional radiator system, with or without weather compensation Components of the Multi-elec Compacte boiler Expansion Vessel Auto top-up system Control panel Ventilation louvre Boiler heating flow Boiler flow sensor Boiler immersion heaters Thermal insulation Boiler heating return Main electrical power input Electric switch grea Digital temperature controller Main electrical isolating switch BREAKSPEAR HOUSE Breakspear House in Harefield, Middlesex is a magnificent Grade I listed building. Phase 1 of the development consisted of the main building being converted into 9 luxury apartments. Ideal for each of these highly insulated rooms were the Atlantic Multi-Elec Compacte boilers each rated at 36kW. These units are robustly made to a working pressure of 4BARS and temperatures from 40 C to 95 C. The boilers were ideal for the luxury surroundings with silent operation and no flue requirement to cause difficulties in the development of the Grade I listed building.
6kW to 24kW RELAX DIGITAL ELECTRIC BOILER Serving radiators, underfloor or convector space heating 2 stage digital controller 1 to 4 BARS working pressure No flues, silent 99% GCV operation 90 C Max working temperature Model 6kW 9kW 12kW 18kW 24kW Output kw 6 6 12 18 24 No of immersion heater elements 3 3 3 6 6 3 phase A 10 15 20 30 40 1 phase A 30 45 60 90 120 Depth mm 350 350 350 350 35p Width mm 405 405 405 405 405 Height mm 820 820 820 820 820 Water content litres 17 17 17 17 17 Dry weight kg 22 22 22 22 22 COMPONENTS OF THE RELAX DIGITALE ELECTRIC BOILER 1. Welded carbon steel body 2. Working pressure 4BARS 3. Incoloy immersion heaters 4. 240V 1phase or 415V 3phase 5. Limit thermostat set at 95 C 6. 2-stage digital controls 7. Digital controller & sensors 8. Maximum working temperature 90 C 9. Metal casing with insulation 10. Remote enable and lockout signal FRONT ELEVATION SIDE ELEVATION
1kW to 12kW CER MODULATING WALL HUNG ELECTRIC BOILER For closed heating systems Maximum working pressure 3BARS Maximum working temperature 80 C Compact: 500mm x 310mm x 320mm Long-life aluminium-silica heat exchanger Model SPM CE01P1-5.12 SPM CE01P3-5.12 Maximum Output 12kW single phase 12kW 3 phase Minimum Output kw 0 0 Full load efficiency GCV 99.5% 99.5% Dry weight kg 25 25 Water content litres 1.3 1.3 Minimum working pressure BARS 0.8 0.8 Maximum working pressure BARS 2.0 2.0 Test pressure BARS 3.0 3.0 Underfloor working temperature 50 C 50 C Maximum working temperature 80 C 80 C Safe limit temperature 90 C 90 C Ultimate limit temperature 115 C 115 C DIMENSIONS Height mm 500 500 Width mm 320 320 Depth mm 310 310 Access front mm 500 500 Access sides mm 500 500 Access bottom mm 800 800 Access top mm 150 150 CONNECTIONS Heating flow & return 28mm bspt 28mm bspt Automatic air vent 8mm bspt 8mm bspt Space Heating Expansion Vessel TYPICAL HEATING CIRCUIT Auto top-up system HOUSE FOR THE ART LOVER Atlantic Boilers of Lancashire have supplied their new CER electric boiler at The House for an Art Lover Glasgow. To provide space heating for the studio building, CER 1-12kW modulating electric boiler was chosen to input the heat. The boiler is ultra-efficient (99.5%GCV), provides precise heat input and is whisper-silent in operation.
SPACE HEATING 6kW to 27kW WATER HEATING 445 to 805ltrs/hr HBI-S20 ELECTRIC COMBINATION BOILER Quiet operation No flues, no pollution Precise controls give low running costs Easy installation into a variety of spaces (eg under stairs, in attics) Model 9kW/265ltrs 27kW/265ltrs Heat Input 9kW 3-step control 27kW 3-step control Full load efficiency GCV 98.6% 99.3% Maximum output kw 8.875 26.875 Maximum space heating range kw 6.0 to 8.875 12 to 26.875 Available 10min domestic hot water output against maximum space heating 120 ltrs 10 to 45 C 120 ltrs 10 to 45 C Maximum domestic hot water output priority over space heating 3.0kW 9.0kW In 10 minutes 295 ltrs 10 to 45 C 355 ltrs 10 to 45 C In one hour 445 ltrs 10 to 45 C 805 ltrs 10 to 45 C Dry weight kg 68 76 Water content litres 265 265 Minimum water pressure BARS 0.5 0.5 Standard water pressure BARS 3.0 3.0 *Maximum pressure available BARS 6.0 6.0 Height mm 1600 1600 Diameter mm 570 570 Access front mm 500 500 Access sides mm 300-500 300-500 Access rear mm 100 100 Access top mm 150 1250 The HBI-S20 electric combination boiler has a 265litres store of heated water ready to serve a space heating system and also, through a powerful heat exchanger coil, provides substantial domestic hot water as and when required. CONNECTIONS Mains cold water supply mm 0 20 Balanced hot water flow mm 20 20 Balanced cold water flow mm 20 20 Space heating cold feed mm 20 20 Space heating flow mm 20 20 Space heating return mm 20 20 Boiler drain valve mm 15 15 Electrical supply single phase amps 48 130 Electrical supply three phase amps 16 per phase 45amps per phase
TYPICAL CIRCUIT Space heating Domestic hot water generator coil Hot and cold water distribution Cold water supply Heat storage for hot water priority and space heating I Immersion heater SPECIFICATION The inner vessel is fabricated from 316L austenetic stainless steel, fitted with dished ends and argonarc welded using the tungsten inert gas process. It is the corrugated and finally de-stressed and surface treated. The outer vessel is also make from 316L stainless steel and is fitted around the inner vessel. Overall insulation is 30mm thick polyurethane foam with a hard polystyrene outer case enamelled in white. Two or three 3kW 240V immersion heaters in accordance with BS EN 60335-2-7 having long life incoloy immersion elements and thermostats. A package of ready-to-fit components are provided with the vessel: A heating circulating pump with cast iron body, stainless steel rotor and can, ceramics, carbon, aluminium and EPDM outer components, a heating 3-port rotary valve suitable for diverting primary hot water in a closed circuit application, an unvented DHW kit with pressure regulating valve, non return valve, expansion vessel, a temperature and pressure relief valve and a set of copper pipes cut to length with necessary fittings. Controls are: A blending valve, a wall mounted weekly temperature controller in compliance with CEI EN 60730-1- 2, 8amp switching capacity, comfort and economy control settings (2 C to 62 C, Δ 0.25 C), two year battery standby life, summer/winter modes, a wall mounted control panel comprised of: a polycarbonate enclosure to Ip67, a heavy duty contactor and control relay, DIN-rail terminals and a 24 hour control on the incoming single phase electrical. The package consists of :- - The S20 body & exchanger, 316L austenitic stainless steel throughout, and made to directive 97/23/CE and according to EN 2883.1992/A1:1997. Insulated with 30mm thick, CFC-free polyurethane foam (ASTM D-1692) and a polyester hard outer finish - Three 3kW to 9kW single phase immersion heaters having brass bosses with fixed elements, a 25mm cold zone and fitted with control and over-heat thermostats - One space heating pump and a 3-way/2-position motorised valve - One domestic hot water 3-way mechanical blender valve - One mountings pack and un-vented kit - One Master control Panel complete with in-built 24-hours power time-switch, remote 7-day multi-time zone remote room sensor and trailing cables to above items EDINBURGH CASTLE The Castle is the most visited paid-for tourist attraction in Scotland and is maintained by Historic Scotland. The boiler is tucked away in a convenient century s old corner and it gives no problems of noise, no pollution, and no necessity for chimneys. ATLANTIC HBI-S20 electric combination boiler to meet the radiator heating and hot water needs for the History Building and gives precise control and easy installation. The boiler serves loads from 6kW to 27kW and can vary the mix of loads between space heating and domestic hot water.
3kW to 108kW WATER HEATERS 580 to 4,180ltrs/hr C20 ELECTRIC DOMESTIC HOT WATER HEATERS Serving offices to restaurants, changing rooms to leisure centres 3 stage controller available 1 to 7BARS working pressure 55 C to 90 C maximum working temperature Silent 99% GCV operation Model 300 500 750 1000 1500 2000 2500 Dry weight kgs 70 90 115 150 230 390 470 Water contents litres 300 500 750 1000 1500 2000 2500 Minimum pressure BARS 0.5 0.5 0.5 0.5 0.5 0.5 0.5 Standard pressure BARS 3.0 3.0 3.0 3.0 3.0 3.0 3.0 Maximum pressure BARS 8.0 8.0 8.0 8.0 8.0 8.0 8.0 DIMENSIONS C20 Model 300 500 750 1000 1500 2000 2500 Height mm 1700 1750 1660 2110 2390 2145 2645 Diameter mm 580 720 890 890 1020 1270 1270 Access front mm 1000 1000 1000 1000 1000 1000 1000 Access sides mm 500 500 500 500 500 500 500 Access rear & top 200 200 200 200 200 200 200 The C20 series buffer vessels are single wall tanks for electric domestic hot water generation and storage. EXAMPLE OF PERFORMANCE many economic solutions are possible. Model First 10 minutes output at 60 C in litres First one hour s output at 60 C in litres C20-300/3x6kW 330 580 Full load efficiency 99.4% GCV 99.4% GCV C20-500/3x12kW 550 980 Full load efficiency 99.6% GCV 99.6% GCV C20-750/6x9kW 830 1570 Full load efficiency 99.7% GCV 99.7% GCV C20-1000/6x12kW 1110 2175 Full load efficiency 99.8% GCV 99.8% GCV C20-1000/9x12kW 1250 2750 Full load efficiency 99.8% GCV 99.8% GCV C20-1500/3x12kW 1450 1875 Full load efficiency 99.3% GCV 99.3% GCV C20-2000/3x9kW 1875 2200 Full load efficiency 99.1% GCV 99.1% GCV C20-2500/3x9kW 2335 2745 Full load efficiency 98.5% GCV 98.5% GCV
TYPICAL CIRCUIT Balance Hot & Cold Water Secondary circulation 2 x C20 stainless steel cylinders with 6 immersion heaters in each cylinder Mains Cold water supplly The description is :- (a) The vessel is fabricated from chrome-nickel-molybdenum stainless steel, fitted with dished ends, argon-arc welded using the tungsten inert gas process, then de-stressed and surface treated. The vessels have a maximum working temperature of 90 C and a maximum working pressure of 8BARS (b) The vessels are available in vertical (with legs) or horizontal (with cradles) form (c) C20 series insulation is CFC-free polyurethane foam with a polyester outer jacket (d) Manufactured tp ISO 9001:2000 (Certificate ESPMDD001829:27/11/03) (e) Modules of 6kW, 9kW and 12kW single or three phase immersion heaters, having screwed bosses with fixed elements, 25mm cold zone and fitted with control and over-heat thermostats, plus IP55 polypropylene terminal enclosures (f) Mountings pack with safety valve, anti-vacuum plug, high capacity automatic air vent and drain ball valve (g) Unvented kit with ball valves, strainer, pressure regulating valve and gauge, non-return valve, expansion vessel(s), temperature & pressure relief valve (h) Master Control Panel incorporating remote buffer vessel temperature sensor, step control of the immersion heaters and other accessories. BARTS HOSPITAL, LONDON The Barts Health new hospitals project is replacing many ageing buildings at St Bartholomew s (Barts) in Central London. For the cardiac centre of excellence include two Atlantic C20-1000 litres domestic hot water buffer storage vessels with three 18kW stages of heat input and a high level of thermal insulation. Standard capacities up to 6000 litres are available.