Specification Document. Color-changing Recovery Type Water Leakage Sensor AD-RS

Similar documents
Specification Document. Heat-resisting Type Water Leakage Sensor FR-AD

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Water Leakage Location Detector AD-AS-1LCM-A Operation Manual

Catalogue Telecommunication Cables INTRODUCCIÓN

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Ceiling Mount Temperature Sensor

Neostat Room Thermostat, Room Humidistat

High Performance LSZH Fire Resistant Cable

K7L-U/K7L-UD. Liquid Leakage Sensor Amplifiers for Long-distance Wiring. Enables longdistance. up to 400 m.

Telecommunication Cables

General safety precautions English

High Performance Hose High Performance Hose

Original instructions. Operation Manual & Cautions

Horizontal/Side Discharge Condensing Units

MARUYASU INDUSTRIES CO.,LTD.

Tissue-Tek TEC Plus Cryo Console OPERATING MANUAL

Model Communication Interface Sensors 2JCIE-BL01 Bluetooth low energy Temperature, Humidity, Light, UVI, Absolute pressure, Noise, Acceleration

Hygro/hygrothermal transducers (hygrometric)

Alphasense Application Note AAN 106 HUMIDITY EXTREMES: DRYING OUT AND WATER ABSORPTION

3kW 6kW, QUBE Fiber Lasers

Heaters for. Hot Runner Systems. COIL Heaters l MICRO TUBULAR COIL Heaters l. The first choice, to last...

Hygro/hygrothermal transducers (hygrometric)

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

INSTRUCTION MANUAL EPH-121 CONTENTS

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

CHEST FREEZER Model Number: EWCF5W

DSSLF2X04H 2 IN 1. Intelligent Lead Free Soldering Station. OPERATION and MAINTENANCE MANUAL

Portable Air-conditioner Use and Care Manual

General safety precautions English

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

Wood pellet and biomass system ceramic igniter

General safety precautions English

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

TH450A-CRB TH550A-CRB THP550-CRB/TS3000

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

F1202 TRACE HEATING. Road & Ramp

Washing Machine OWNER S MANUAL TRWTL-70. Before using your washing machine, please read this manual carefully and keep it for future reference.

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

SAS Security and Alarm Safety Cables

Installation Instructions

Installation Instructions

1592P01. for liquids in piping DN

Flame Retardant Overall Screened Instrumentation Cables (multicore)

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

General safety precautions English

Use and Care Manual. MODELS H VAR 1.5 THRU 5 TON 13 Seer Split System Heat Pump REV. 4/06

AlarmLine Addressable Linear Heat Detector

Intelligent Lead Free Soldering Station OPERATION and MAINTENANCE MANUAL

FIRE PERFORMANCE CABLE

In-Wall Slide-out OEM INSTALLATION MANUAL. In-Wall Slide-out OEM Installation Manual

SPR7-OS SPR601-OS SCR600L-OS SPR601-OSRC SCR600L-OSRC SP6DSSTB-OS

600/1000V SR Insulated Flexibles Control Cables (2-4 Cores & Multicores)

Brazed Plate Heat Exchanger Instruction Manual for BX Series

Operation Manual Air-refrigerated Thermo cooler HRG010-A HRG015-A SMC Corporation Save This Manual Carefully for Use at Any Time

Specification Document. Single-circuit Water Leakage Detector AD AS 1AM (RoHS-directive-compatible)

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

APS-S/M Series. Polycarbonate Resin Square Type, 2-wire/3-wire DC System. Type. Proximity Sensor. Features

INSTALLATION GUIDE Induction Cooktops

Portable Air-conditioner

FIRE RESISTANT CABLES

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

TAIJI HOTCABI Towel Warmer

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan

INVERTER SPLIT - TYPE

Split-type Air-Conditioner

Smokeless Roaster Operational Manual

Flexflame. Arctic Grade Cables for Extreme Conditions. Photo: Sakhalin Energy Investement Company Ltd.

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

Installation Instructions

General safety precautions English

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

INSTRUCTION MANUAL CLEAN BELLOWS TYPE INDUSTRIAL ROBOT SPECIFICATIONS. Notice

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

Flexible Power Cable DLO

Split-type Air-Conditioner

Model No. NR-BU303 Series

Split-type Air-Conditioner

ASL T6 / T7 / T8 / T9 FLOOR GRINDING MACHINES MANUAL

TECHNICAL DATA & SERVICE MANUAL

DAIKIN ROOM AIR CONDITIONER INSTALLATION MANUAL

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Reverse Package Infrared LED IR25-21C/TR8

Installation Instructions

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

FOT-100. Fiber Optic Temperature Sensor User s Manual P/N: I3A-110

Principles of Cold Insulation

QUICK 3202 OPERATION MANUAL. Lead Free Soldering Station

SENJU SPRINKLER CO., LTD.

User manual of CD-2900 ultrasonic contact lens cleaner

INSTALLATION INSTRUCTIONS TXV Horizontal Duct Coils EHD

KSGD-01W/S SEMI CONDUCTOR STAND ALONE REFRIGERANT LEAK DETECTOR. Instructions for :- KSGD-01W/S Semi Conductor Standalone Refrigerant Leak Detector

Installation Instructions

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

SECTION ELECTRICAL GENERAL PROVISIONS

SAND FILTER PUMP MANUAL

AlarmLine Linear Heat Detector

Transcription:

TS-KS-W11608-1 To: Specification Document Color-changing Recovery Type Water Leakage Sensor AD-RS Date:( ) <Manufacturer > System Equipment Division Electronic Materials & System Equipment Group TATSUTA Electric Wire & Cable Co., Ltd. System Equipment Division Approved by: Checked by: Prepared by:

<<<Important safety instructions>>> Warning Improper handling of the sensor in non-compliance to any of the following warning precautions or instructions given on a WARNING label can result in death, serious injury, fire, electric shock, and/or sensor failure. Warning Precautions Strictly Prohibited! Never use the sensor as electric cable. Confirm! The sensor length must not exceed 100 m per circuit. Handle the sensor carefully; it will not work if soiled or damaged. Take precautions to ensure the sensor does not become wet. Before use, be sure to read the precautions on the rear of the sensor case. Caution on Installation! Do not install the sensor directly on any surface where dew can form. Attach the sensor as tightly as possible to the mounting surface. Any unavoidable gap such as on an uneven floor or the like horizontal surface must not exceed 2 mm, and on a pillar, beam or the like vertical surface the gap must not exceed 1 mm. To minimize the influence of external electromagnetic induction, the sensor comprises two electrodes twisted in a braid form. However, avoid installing the sensor over a long distance in parallel with a power cable or other electromagnetic induction sources. Where the sensor intersects a power cable of 300 V or higher service voltage, surround the sensor completely with an insulating protective barrier, such as plastic molding. Install the sensor so that it can be easily replaced. After detection of water leakage, the sensor is reset when the water has evaporated. However, if the sensor absorbs water that contains conductive or water-repellent material, it possibly cannot be reset and needs to be replaced. To prevent electrical corrosion of the sensor, be sure to connect it to an alternate-current water leakage detector. Do not allow wax or other oil-based material on the sensor; water is repelled from the surface and may not be detected.

Table of contents 1. Scope... 1 Page 2. Construction... 1 3. Specifications... 2

1. Scope of Application The specification document is applicable to the color-changing recovery type water leakage sensor (AD-RS). This sensor can rapidly detect water leakage, and becomes red when absorbing water and restores if dried. 2. Construction Fig. 1 and Fig. 2 show the construction of the AD-RS sensor Electrode: 0.33 mm 2 tinned annealed copper wire Inner sheathing: Polyethylene Outer sheathing: Polyester Electrode Inner Sheathing Outer Sheathing Fig.1: Schematic Diagram of the AD-RS Sensor Outer Sheathing (White) Outer Sheathing (Red) Electrode 3.5±0.5mm Fig. 2: Cross-section Diagram of the AD-RS Sensor -1-

3. Specifications Table 1 shows the specifications of AD-RS sensor. Table 1. Specifications Item Specifications Construction Material: Strand of tinned annealed copper wires Composition: Copper wire 0.18mm in diameter 13 (0.33 mm 2 ) Detection characteristic The resistance between electrodes is 5kΩ max. (AC) when the water absorbing (tap water) capacity is 3.0 ml or below. Water dropping amount: directly drop to the sensor (0.05ml/s) Measuring ambient temperature: 24, humidity: 60%RH Conductivity water temperature: 24, 200μS/cm [5.0kΩ cm] Testing equipment: Water leakage detector AD-AS-10DRM manufactured by our company. The resistance between electrodes and the amount of water during the sensor operation are dependent on the laying status, environment and water quality for the sensor. Resetting characteristic After the water leakage detection, the sensor is reset by natural drying or moisture removal. However, if there are conductive or water-repellent substances in the leaking water, the sensor cannot be reused. Resistance between 10 MΩ min. /100m electrodes (AC) (measuring ambient temperature: 24, humidity: 60%RH) Humidity resistance In the high humidity condition, the resistance between electrodes is 100kΩ or above /100m (measuring ambient temperature: 60, humidity: 95%RH) provided that there is no moisture condensation. Heat resistance 60 max. for continuous operation (heat-resistant temperature: 80 ) Weight 10.5±1.0 g/m -2-