II. OBJECTIVE OF RESEARCH

Similar documents
Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

Enhancement of COP in Vapour Compression Refrigeration System

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Pressure Enthalpy Charts

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

ME 410 MECHANICAL ENGINEERING SYSTEMS LABORATORY MASS & ENERGY BALANCES IN PSYCHROMETRIC PROCESSES EXPERIMENT 3

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

Performance Enhancement of Mini Refrigerator with Phase Change Materials

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

CHAPTER 7 PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION REFRIGERATION SYSTEM IN HYBRID REFRIGERATION SYSTEM

ME 410 MECHA ICAL E GI EERI G SYSTEMS LABORATORY

Institute of Aeronautical Engineering (Autonomous) Dundigal, Hyderabad B.Tech (III II SEM) MECHANICAL ENGINEERING

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Performance Assessment of Water Cooled Condenser Refrigeration System

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

(Refer Slide Time: 00:00:40 min)

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

Performance investigation of Air-conditioning system using ejector as expansion device

Performance of an Improved Household Refrigerator/Freezer

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

HVAC Fundamentals & Refrigeration Cycle

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

THE ANALYSIS AND EXPERIMENTAL INVESTIGATION OF HEAT PUMP SYSTEM USING THERMOBANK AND COS EJECTOR CYCLE

International Journal Of Core Engineering & Management (IJCEM) Volume 2, Issue 9, December 2015

Optimum Length of a Condenser for Domestic Vapor Compression refrigeration System

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

Design & Fabrication of Hybrid Cooler

s. Properties for R134a are as follows : Saturated R-134a Superheated R-134a

Experimentation and Fabrication of Iceplant Using Ecofriendly Refrigerant

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

International Engineering Research Journal Performance Analysis of Ejector Based Solar Air Conditioning System

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

Modified Air Cooler with Split Cooling Unit

SAMPLE STUDY MATERIAL

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Lesson 25 Analysis Of Complete Vapour Compression Refrigeration Systems

Performance Optimization of the Evaporative Condenser Design

An Experimental Study on Clothes Drying Using Waste Heat from Split Type Air Conditioner

ISSN Vol.08,Issue.21, November-2016, Pages:

Fig.: macroscopic kinetic energy is an organized form of energy and is much more useful

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Experimental Investigations of Different Types of Condensers on the Performance of Household Refrigerators

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR Siddharth Nagar, Narayanavanam Road AUTONOMOUS QUESTION BANK (DESCRIPTIVE) UNIT I

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Dhulapally, Secunderabad Subject: REFRIGERATION AND AIR CONDITIONING QUESTION BANK

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

SSC-JE STAFF SELECTION COMMISSION MECHANICAL ENGINEERING STUDY MATERIAL REFRIGERATION CYCLES REFRIGERATION CYCLES REFRIGERATION CYCLES

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

Experimental Investigation of a Heat Pump Assisted Fluidized Bed Dryer

Chapter 9. Refrigeration and Liquefaction

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

3. (a) Explain the working of a rotary screw compressor. [10] (b) How the capacity control is achieved in refrigerant compressor?

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Waghmare Tushar Ramrao, D.S.Nakate

ENERGY SAVINGS THROUGH LIQUID PRESSURE AMPLIFICATION IN A DAIRY PLANT REFRIGERATION SYSTEM. A. Hadawey, Y. T. Ge, S. A. Tassou

International Journal of Intellectual Advancements and Research in Engineering Computations

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

R07. Answer any FIVE Questions All Questions carry equal marks *****

[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec REFRIGERATION & AIR-CONDITIONING (Mechanical Engineering)

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

Numerical Simulation of Window Air Conditioner

Refrigerant Glide and Effect on Performances Declaration

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

An experimental study of the effect of evaporator temperature on the compressor work of a simple vapour compression refrigeration system

INSTITUTE OF AERONAUTICAL ENGINEERING

Introductionn to Compressible Flow (Gas Dynamics)

Sarthak Thakar, 2 R.P.Prajapati 1

PLEASE READ AND FOLLOW THESE INSTRUCTIONS

pdfmachine trial version

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

Techniques of Heat Transfer Enhancement and their Application. Chapter 4. Performance Evaluation Criteria for Two-Phase Heat Exchangers

The Condensate Water Systems

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Performance Evolution of Domestic Refrigerator Using LPG Cylinder

GSJ: VOLUME 6, ISSUE 6, JUNE GSJ: Volume 6, Issue 6, June 2018, Online: ISSN

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

LISTOF EXPERIMENTS. S. No. NAME OF EXPERIMENTS PAGE No.

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Transcription:

Enhancement of Coefficient of Performance of Vapor Compression Refrigeration System Using Diffuser at let of Condenser Mr. Nurul Seraj 1, Dr. S. C. Roy 2 1 Student, 2 Head of Department, Department of Mechanical Engineering, B.I.T Sindri, Dhanbad, Jharkhand-828123 Abstract: To Enhanced the Coefficient of Performance, It is to require that Refrigerating Effect Should crease and Compressor Work should decrease. Experimental analysis on vapour compression refrigeration (VCR) system with R134a refrigerant was completed and their results were recorded. The effects of the main parameters of performance analysis such as super heating on the refrigerating effect, power required to run the compressor for various evaporating temperatures, mass flow of refrigerant, percentage increase in COP, coefficient of performance (COP). The results from vapour compression refrigerant plant was taken where the variables like suction pressure of compressor, delivery pressure of compressor, temperature of evaporator and condenser are noted and coefficient of performance is calculated. itially The Diffuser Of creasing Cross- Sectional Area Profile Was Designed, Fabricated And troduced Our VCR Apparatus. The Size Of Diffuser Selected Was Of 15 Degree Divergence Angle. By Using Diffuser Power Consumption Is Less For Same Refrigerating Effect So Performance Is Improved. The Size Of The Condenser Can Also Be Reduced Due To More Heat Transfer. So Cost Of The Condenser Will Be Reduced. The Parameters Pressure And Temperature Were Measured. Keywords:- VCR System, COP, Diffuser, Divergence angle. I. INTRODUCTION The most frequently used refrigeration cycle is the vapour compression refrigeration cycle. vapour compression refrigeration system condenser is used to remove heat from high pressure vapor refrigerant and converts it into high pressure liquid refrigerant. The refrigerant flows inside the coils of condenser and cooling fluid flows over the condenser coils. Condenser used in domestic vapour compression refrigeration system is air cooled condenser, which may be naturally or forced air cooled. Heat transfer occurs from the refrigerant to the cooling fluid i.e., outside air. High pressure liquid refrigerant flows through an expansion device to obtain low pressure refrigerant. Low pressure refrigerant flows through the evaporator. The two phase refrigerant in the evaporator enters into heat exchange relationship with secondary fluid to regulate the temperature of the secondary fluid that is circulated to regulate it, of an area inside the structure. Liquid refrigerant in the evaporator absorbs latent heat and get converted into vapour refrigerant which returned to compressor. Compressor raised the pressure and temperature of the vapour refrigerant and discharged into the condenser to complete the cycle. II. OBJECTIVE OF RESEARCH A. To enhanced the coefficient of performance of vapour Compression refrigeration system by substituting diffuser at inlet of condenser. B. To compare the performance of system with and without diffuser. C. Experimental detail the present cycle, the vapour refrigerant leaves the compressor with comparatively high velocity. This high velocity refrigerant directly impinges on the tubing of condenser which may cause damage to it by vibration, pitting or erosion. It results undesirable splashing of refrigerant in the condenser coil. It also results a phenomenon called as liquid hump. Liquid hump refers to a rise in the level of the condensed refrigerant liquid in the central portion of the condenser as compared to the level at the ends of the condenser. It reduces the effective heat transfer surface area which can reduce condenser efficiency. Diffuser is the static device. It raises the pressure of flowing fluid by converting its kinetic energy. vapour compression refrigeration system, to avoid the problems of high velocity refrigerant, one of the ways is to use diffuser at condenser inlet. It smoothly decelerates the incoming refrigerant flow achieving minimum stagnation pressure losses and maximizes static pressure 172

recovery. Due to pressure recovery, at same refrigerating effect, compressor has to do less work. Hence, power consumption of the compressor will be reduced which results improvement in system efficiency. As the refrigerant flow passes through the diffuser, pressure as well as temperature will be increased. air cooled condenser, for constant air temperature, temperature difference between hot and cold fluid will be increased. Amount of heat rejected from condenser will be rise. To remove the same amount of heat, less heat transfer area will be required. Using the diffuser at condenser inlet will provide an opportunity to use a smaller condenser to achieve the same system efficiency. Use of diffuser will also provide an advantage of reducing the effect of starvation in vapour compression refrigeration systems. The cross-sectional area of diffuser should reduce in the flow direction for supersonic flows and should increase for subsonic flows. The velocity of refrigerant leaving the compressor is sub-sonic. Hence, cross-sectional area of diffuser should be increasing. Diffuser s inlet and outlet diameters were designed. To design length of diffuser equation ( 1 ) is developed from Figure4.3 L = AB = ( )/ ---------------- ( 1) Relation between length and divergence angle of diffuser plotted as shown in Figure 1. With increase in divergence angle of diffuser, its length is reduced for same inlet and outlet diameters. Geometry of diffuser(d/l=0.6) ner diameter=20 mm Outer diameter=38mm Angle of divergence=15 Length of diffuser=33.5mm L = AB = ( )/ D. Steps to making diffuser To make the diffuser a metal plate is required. 1) Marking the metal plate with required size. 2) Scribing the metal plate at 60 angle. 3) Cut the scribing plate with help of Straight snip. 4) Work on Sheet bending machine to bending the cutting plate. 5) Work on edge folding machine to fold the edge of the shape. 6) Use Round bottom stake to making round shape. 7) Use Funnel stake for hammering 8) Wooden mallet a wooden hammer to make desire shape. 9) Weld the bend section and cross section of final shape. E. Tool required in an experiment 1) Tube cutter. 2) Tube bender. 3) Flaring too 4) Temperature and pressure measuring device. 5) Vacuum pump. Fig 1 Geometry of diffuser 173

III. EXPERIMENTAL SETUP This experimental setup has been carried out to investigate the coefficient of performance of VCR system with diffuser at inlet of condenser. This setup has been fabricated in the heat engine laboratory at BIT, sindri.this is possible as study of the basic schematic diagram of experimental test set up shown in figure 4.11 and with observing basic principle of design and assembly of refrigeration system. Its overall view is shown in figure 4.13 the laboratory experiments were then carried out with main objective to investigate the possibility of pressure jump on the diffuser. Fig 2 schematic diagram of experimental test set up A. Working principle of experimental setup The novel experimental which is carried out in laboratory undergoes various processes during working of this new refrigeration system. Which is illustrates with P-h chart shown in figure 4.12 Fig 3 pressure-enthalpy chart 174

Fig 4 schematic diagram of installed setup ( above figure temperature of evaporator is 15.6 ) B. Experimental measurement Without diffuser P (Psi) P (Psi) P (Psi) P (Psi) 5 140 140 5 T (0 ) T (0 ) T (0 ) T (0 ) 31.6 42.7 33.8-15 C. Experimental measurement With diffuser P (Psi) P * (Psi) P (Psi) P (Psi) 5 148 148 5 T (0 ) T * (0 ) T (0 ) T (0 ) 33.1 44.5 34.0-15.2 D. Where P = Suction Pressure P = Discharge Pressure P * = Pressure at the exit of diffuser P = Pressure at the exit of condenser P = Pressure at the exit of expansion device T = Suction temperature T = Discharge temperature T * = Temperature at the exit of diffuser T = Temperature at the exit of condenser T = Temperature at the exit of expansion valve E. Note Net Refrigeration effect is maintained constant with the help of the variable speed drive to the compressor in both the systems of with and without diffusers. Condenser Temperature is maintained constant with the help of the variable speed drive to the fan motor. Compression process is assumed to be reversible adiabatic or isentropic. Compressor work (W.D) = h - h 175

Diffuser work (W )= h - h Refrigeration effect (R.E) = h - h For same refrigeration effect h = h =h Reduction in compressor work = compressor work diffuser work =( h - h ) (h - h ) From the p-h chart of R-134a as shown in figure in, the following values can be obtained. h = 448kj/kg h = 498kj/kg h = 503kj/kg h = h =h = 248kj/kg Compressor work (W.D) = h - h = 498 448 =50kj/kg Diffuser work (w ) = h - h = 503-498 = 5kj/kg Refrigeration effect = h - h = 448 248 = 200kj/kg Reduction in compressor work = (h -h ) (h -h ) = (498 448) (503 498) = 50 5 = 45kj/kg COP = = = 4 COP = 4 COP = = = 40/9 = 4.444 COP = 4.444 Hence the cop increased in vapour compression refrigeration system. creased COP = COP - COP = 4.444 4.000 = 0.444 creased in COP = 0.444. Percentage increased in COP = 100 = 100. = 9.009 % E. Result It is clear that from above COP is greater thancop. Hence we can say that COP increased by 9.009% in vapour compression refrigeration system when diffuser is introduced at inlet of condenser. F. Now we want to find heat extract from condenser Heat removed from condenser when diffuser is not used = h - h = 498-248 = 250kj/kg 176

heat removed from condenser when diffuser is not used=250kj/kg Heat removed from condenser when diffuser is used is. = h *- h = 503 248 = 255kj/kg heat removed from condenser when diffuser is used = 255kj/kg 1) Result: From above it is also clear that the heat removed from condenser is increased when diffuser is used at inlet of condenser in vapour compression refrigeration system. Another method to finding COP:- h = enthalpy of vapour refrigerant at T, i.e. at suction of compressor and, h = Enthalpy of vapour refrigerant at temperaturet, i.e. at discharge of compressor without diffuser. h * = Enthalpy of vapour refrigerant at temperaturet, i.e. at discharge of compressor with diffuser. hf = h = Sensible heat at temperaturet, i.e. enthalpy of liquid refrigerant leaving of condenser. COP = Coefficient of performance without diffuser. COP = Coefficient of performance with diffuser. Experiment calculation is taken from Table 01 & Table 02 Table:-The value of enthalpy at different evaporator temperature from p-h chart is. Evap. temp. in 0c h kj/kg h h * hf = h R.E (Kj/kg) WD (Kj/kg) W h h Reduc. in work WD-W (kj/kg) (kj/kg) (kj/kg) (kj/kg) (kj/kg) 7.75 483 512 518 246 237 29 6 23-4-9 463.5 501 505 246 217.5 37.5 4 33.5-8.3 458.5 500 504 246 212.5 41.5 4 37.5-9.3 453 498 502 248 205 49 4 45-13.1 452 497 501 249 203 49 4 45-15 448 498 503 248 200 50 5 45 COP = = COP = Table: - Calculated value of COP for different temperature of evaporator with and without diffuser. = ( ) Evaporator temperature 7.75-4.9-8.3-9.3-13.1-15 in (O ) COP 8.172 5.80 5.12 4.184 4.143 4.0 COP 10.304 6.4925 5.667 4.555 4.511 4.44 177

12 10 8 6 4 COP2 COP1 2 Fig.5 Graphical representation of COP1&COP2 vs Evaporator temperature Average value of COP =... =. = 5.2365 Average value of COP = 5.2365 Average value of COP =.... = Average value of COP = 5.9949 Now, increase in the value of COP is = COP - COP = 5.9949 5.2365 = 0.7584 0-15 -13.1-9.3-8.3-4.9 7.75 = 5.9949 increase in the value of COP = 0.7584 Also, percentage increases in the value of COP is = 100 =.. = 14.48% 2) Result: From above it clear that when average value of COP with & without diffuser is taken at different evaporator temperature then percentage increased in COP is 14.48%. Which is more than the previous value of COP =9.009% calculated. REFERENCES [1] R.S. J K Gupta A Textbook of Refrigeration and Air Conditioning, S Khurmi Chand & Co Ltd publication 2006,pp. 306-313,727-730 [2] Rajput R.K. A Textbook of Refrigeration and Air-Conditioning, S.K.Kataria & Sons publication 2012,pp.96-11 [3] Amitprakash IMPROVING THE PERFORMANCE OFVAPOUR COMPRESSION REFRIGERATION SYSTEM BYUSING SUBCOOLING AND DIFFUSER IJEBEA 13-129 201 [4] R. Rejikumar et.al HEAT TRANSFER ENHANCEMENT IN DOMESTIC REFRIGERATOR USING R600a/mineral oil/ nano-al2o3 AS WORKING FLUID IJCER APRIL 2013 VOL 03,ISSUE 04 [5] M. Krishna Prasanna M.E. student, and P.S Kishore ENHANCEMENT OF COP IN VAPOUR COMPRESSIONREFRIGERATION SYSTEM IJERT NOV 2014 VOL 3, ISSUE11 [6] R.T.Saudagar and Dr.U.S.Wankhede VAPOUR COMPRESSIONREFRIGERATION SYSTEM WITH DIFFUSER ATCOMPRESSOR INLET IJERD JULY 2012 VOL1, 178