[Jhansi, 5(10): October 2018] ISSN DOI /zenodo Impact Factor

Similar documents
A REVIEW ON HEAT TRANSFER ENHANCEMENT BY PASSIVE METHODS

Enhancement of COP by Using Spiral and Microchannel Condenser instead of conventional Condenser of VCR System

Performance Evaluation of VCRS with Nested Helical Shaped Condenser by Using R134a as Refrigerant

ijcrr Vol 04 issue 07 Category: Research Received on:06/02/12 Revised on:17/02/12 Accepted on:02/03/12

Waghmare Tushar Ramrao, D.S.Nakate

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Experimental Study And CFD Based Simulation of Closed Loop Pulsating Heat Pipe Using of Refrigerants (R-134a)

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

Design, Development & Testing of Double Pipe Heat Exchanger With Heat Transfer Enhancement Liners

Optimum Length of a Condenser for Domestic Vapor Compression refrigeration System

EXPERIMENTAL INVESTIGATIONS ON AL 2 O 3 NANO REFRIGERANT WITH DIFFUSER AT CONDENSER INLET IN A VCR SYSTEM

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

[Vali*, 5(2): February, 2016] ISSN: (I2OR), Publication Impact Factor: 3.785

Experimental study on heat transfer characteristics of horizontal concentric tube using twisted wire brush inserts

Improving and Comparing the Coefficient of Performance of Domestic Refgirator by using Refrigerants R134a and R600a

Enhancement of COP in Vapour Compression Refrigeration System

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Experimental Study on Performance Parameters for Refrigerants R22, R410a and R404a at Various Air Outlet Temperatures

PERFORMANCE OF VCRS SYSTEM WITH HEAT EXCHANGER AND PHASE CHANGE MATERIAL

Thermal Design of Condenser Using Ecofriendly Refrigerants R404A-R508B for Cascade Refrigeration System

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

1, 2

EXPERIMENTAL INVESTIGATION OF COMPARISION OF AIR COOLED AND WATER COOLED CONDENSER ATTACHED WITH COOLING TOWER

WASTE HEAT RECOVERY FROM DOMESTIC REFRIGERATOR Soma A. Biswas 1, Sandeep M. Joshi 2 1,2 Pillai College of Engineering

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Numerical Study on Improvement of COP of Vapour Compression Refrigeration System

II. OBJECTIVE OF RESEARCH

EXPERIMENTAL INVESTIGATION OF WATER COOLER SYSTEM BY USING ECO-FRIENDLY REFRIGERANT (R-134a)

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

A Generalized Correlation for Pressure Drop of Refrigerant R-134a through Helical Capillary Tubes

EXPERIMENTAL VERIFICATION OF PERFORMANCE OF CAPILLARY TUBE USING VAPOUR COMPRESSION REFRIGERATION SYSTEM

A Review on Analysis of Vapour Compression Refrigeration System Using Matrix Heat Exchanger

A STUDY ON COMPACT HEAT EXCHANGERS AND PERFORMANCE ANALYSIS

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Performance of window air conditioner using alternative refrigerants with different configurations of capillary tube

IJESRT. Scientific Journal Impact Factor: (ISRA), Impact Factor: 1.852

PERFORMANCE ANALYSIS OF VAPOUR COMPRESSION THERMOELECTRIC REFRIGERATION SYSTEM WITH NOZZLE AND DIFFUSER THROUGH INCORPORATION OF PHASE CHANGE MATERIAL

Performance Analysis of Electronic Expansion Valve in 1 TR Window Air Conditioner using Various Refrigerants

Effect of Louvered Strips on Heat Transfer in a Concentric Pipe Heat Exchanger

Performance Assessment of Water Cooled Condenser Refrigeration System

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

U.G. Student, Department of Mechanical Engineering, J D Engineering College, Nagpur, Maharashtra, India

International Journal of Engineering Research (IJOER) [Vol-1, Issue-3, June- 2015]

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Performance Comparison of Ejector Expansion Refrigeration Cycle with Throttled Expansion Cycle Using R-170 as Refrigerant

Performance investigation of Air-conditioning system using ejector as expansion device

International Journal of Engineering Research & Technology (IJERT) ISSN: Vol. 2 Issue 10, October

Enhancement of COP using Nanoadditives in Domestic Refrigerator

Experimental Analysis of Performance Characteristics of Mini Channel Heat Exchangers

Design and Development of Water Cooled Condenser for Domestic Refrigerator

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

Experimental Study of Modified Refrigerator Cum Air Conditioning and Water Cooler System

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

To Improve Cop of Domestic Refrigerator with the Help of Water Cooling Condenser

Pressure drop analysis of evaporator using refrigerants R-22, R-404A and R-407C

Analysis of Coefficient of Performance & Heat Transfer Coefficient on Sterling Cycle Refrigeration system.

Sarthak Thakar, 2 R.P.Prajapati 1

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Global Journal of Engineering Science and Research Management

An Experiment of Heat Exchanger Produces Hot Water Using Waste Heat Recovery from Air Conditioning

Design & Fabrication of Hybrid Cooler

Experiment 2: Test on Domestic Refrigerator for evaluation of EER.

Analysis of a Condenser in a Thermal Power Plant for Possible Augmentation in its Heat Transfer Performance

Performance analysis of ejector refrigeration system with environment friendly refrigerant driven by exhaust emission of automobile

A Review of Hydroflorocarbons (HFC S) Refrigerants as an Alternative to R134a Refrigerant

PERFORMANCE ENHANCEMENT OF AIR CONDITIONER *

Performance Enhancement of Mini Refrigerator with Phase Change Materials

EXERGY ANALYSIS OF DOMESTIC REFRIGERATOR WITH DIFFERENT REFRIGERANTS

Effect of Heat Exchanger Configuration on the Performance of Joule-Thomson Refrigerators

"COP Enhancement Of Domestic Refrigerator By Sub cooling And Superheating Using Shell &Tube Type Heat Exchanger"

Experimental Analysis of Heat Exchanger and Simulation of Result Using Solid Works Software

Performance Optimization of the Evaporative Condenser Design

Modified Air Cooler with Split Cooling Unit

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Capillary Tube and Thermostatic Expansion Valve Comparative Analysis in Water Chiller Air Conditioning

Improvement Of Energy Efficiency Ratio Of Refrigerant Compressor

To investigate the surface properties for increasing efficiency of solar water heater

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

ANALYSING THE EFFECTIVENESS OF THE HEAT EXCHANGER BY INCREASING OVERALL HEAT TRANSFER COEFFICIENT

COMPACT HEAT EXCHANGERS FOR MOBILE CO 2 SYSTEMS

An experimental study of the effect of evaporator temperature on the compressor work of a simple vapour compression refrigeration system

Performance Characteristics of Air-Conditioner Under Tropical Ambient Condition

Fabrication and analysis of instantaneous water cooler by using isobutane as refrigerant

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

HEAT TRANSFER ENHANCEMENT IN SHELL AND TUBE HEAT EXCHANGERS USING INSERTS

Waste Heat Utilization of Vapor Compression Cycle for Operation of Vapor Absorption System

REVIEW ON HOT GAS DEFROSTING SYSTEM FOR VAPOR COMPRESSION REFRIGERATION SYSTEM

Performance Analysis of Solar Assisted Cascade Refrigeration System of Cold Storage System

Seyedeh Sepideh Ghaffari 1 & Seyed Ali Jazayeri 2

FROSTING BEHAVIOR OF FIN-TUBE HEAT EXCHANGER ACCORDING TO REFRIGERANT FLOW TYPE

Department of MCE, Islamic University of Technology 2. Abstract

A study of Transient Performance of A Cascade Heat Pump System

Performance of an Improved Household Refrigerator/Freezer

Transcription:

GLOBAL JOURNAL OF ENGINEERING SCIENCE AND RESEARCHES PERFORMANCE ANALYSIS OF VCR SYSTEM WITH TWISTED TAPE CONDENSER BY USING R134a REFRIGERANT Chidige Jhansi* 1 & Dr.Smt.G.Prasanthi 2 *1 PG Research Scholar Refrigeration and Air-Conditioning, Mechanical Engineering, JNTUA College of Engineering Ananthapuramu, Andhra Pradesh, India-515002. 2 Professor of Mechanical Engineering, Director, Faculty Development & IQAC, JNTUA Ananthapuramu, Andhra Pradesh, India-515002 Abstract This research work reports on the performance analysis of a vapour compression refrigeration system with twisted taped condenser by using R134 as refrigerant. Majority of the refrigerators today works on the VCR system. This system consists of the following important components, compressor, condenser, expansion valve and evaporator. The accomplishment of the system depends upon the all the parts of the system. The main purpose of this research work is to intensify the heat transfer rate through the condenser coil by inserting the twisted tapes into the condenser coil.the twisted tapes with twisting ratio (y/d=2.134) is used. In this research work two twisted tapes one with Al and another one with Cu are separately inserted into the condenser coils and the performances of both the coils compared with the existing system. Twisted tape is a type of vertex generator which can give the swirl flow to the fluid, due to this the temperature difference of the fluid with the surroundings increases, which can finally results to a high heat transfer coefficient. Finally it is observed that the COP of the twisted taped condenser coil refrigerator is more while comparing with the existing system. The performance parameters such as refrigerating effect, mass flow rate, compressor work and coefficient of performance are calculated. Finally the performances for both Cu and Al twisted tapes are compared Keywords: Heat transfer intensification, twisted tape, swirl flow, mass flow rate, coefficient of performance and twisting ratio. I. INTRODUCTION Most of the domestic refrigerators are operate on vapour compression refrigeration systems and run for usual C.O.P. which pays attention to intensify the cop with some alternations made on the components assembled in the system. Fig shows the simplified diagram of components of a VCR system. 49

In the thermodynamic cycle the refrigerant such as R-134a in vapour state enters into the compressor.the vapour refrigerant is compressed into the hermetically sealed compressor to high pressure and high temperature at constant entropy. Then this high pressure and high temperature gaseous refrigerant sent into the condenser coil and condenses into a liquid from vapour state by removing extra heat at constant pressure and temperature. After that the liquid refrigerant passes through the expansion valve, where its pressure diminishes suddenly. Finally it is sent into the evaporator coil at low pressure and low temperature liquid refrigerant absorbs the heat present in the evaporator and transforms into vapour form, with this one cycle completes. Now again the refrigerant sent into the compressor then starts the new cycle. There are two methods to intensify the heat transfer rate. Those include Active methods and Passive methods. Active Methods Active methods are those which need external power source to ensure the enhancement mechanism. Examples of the active methods includes fan providing on the condenser coil for rapid cooling, sprays and jet impingement etc Passive Methods Passive methods are those which doesn t need external power source to ensure the enhancement mechanism. Examples of the passive methods includes smooth surfaces,rough surfaces, twisted tape inserts, helical inserts, displacement enhancement appliances,coiled wires,ribs,baffles and winglets. In this research work one of the passive method i.e. twisted tape is used to intensify the heat transfer rate. Hence the twisted tape doesn t require additional power source to enhance the heat transfer rate. It can create swirl flow to the flowing fluid. These twisted tapes decrease the hydraulic diameter of the flow passage. This flow blockage increases the velocity of flow and sometimes it gives the secondary flow. This secondary flow further adds better thermal contact between surface and the fluid because this flow generates the swirl flow and intensifies the temperature difference with the surrounding which finally leads to a high heat transfer coefficient. II. EXPERIMENTAL WORK The condenser is one of the most important components of VCRS system which contributes a lot in the overall performance. Effectiveness of its working through rigged control is taken over various performances affecting attributes correlate to it, delivers the worth accepted results at minimum possible cost expenditure. As function of the condenser is dissipating the heat absorbed by the refrigerant during the evaporation process and comparison. The 50

refrigerant cop is the function of its operating temperature, the current work under takes modification of condenser geometry and thus the temperature gradient with the surrounding regulation maintained system cop would be high. This research work is concentric about twisted tapes inserted into the condenser coil of refrigerator (R134 a) holding 165 liters capacity. Twisted tapes are the metallic strips twisted using some of the suitable methods as per the required shape and dimension, which are inserted in the flow to enhance the heat transfer rate. The twisted tape inserts are most suitable and widely used techniques to enhance the H.T. rate. The heat transfer enhancement of twisted tape inserts depends on the pitch and twist ratio. Experimental setup The domestic refrigerator selected for the research work has the following specifications: Refrigerant used : R -134a Capacity of the Refrigerator : 165 liters Compressor Capacity : 0.16H.P. Condenser sizes Length - 8.5 m Diameter - 6.35mm Evaporator Length - 7.62 m Diameter - 6.4mm Capillary Length - 2.428m Diameter - 0.8mm Specifications of twisted taped condenser: Diameter - 8.8mm Length - 36ft No of turns - 13 51

Twisting ratio - 2.134 Angle of twist - 180 0 III. EXPERIMENTAL PROCEDURE The following procedure is adopted for experimental setup of VCR system. The domestic refrigerator working on VCR system ( R-134 a) and having capacity of 165 liters is taken. Pressure and temperature gauges are installed at each entry and exit of the components. Along with this one thermocouple is placed at the evaporator. Flashing of the system is done by pressurized nitrogen gas. R- 134 a refrigerant is charged into the VCR system. Leakage tests are done by using soap solution, in order to further test the condenser and evaporator pressure and check purging for 12 hours and found that there is no leakage which required absolutely the present investigation to carry out further experiment. The refrigerator is switched on and observation is required nearly for 50 to 60 min and take the pressure and temperature readings at each section. By using these temperature and pressure gauge readings the performance of the existing system is found out. The refrigerant is discharged out and twisted taped condenser coil is placed between the compressor and capillary tube. The temperature and pressure gauge readings are taken and then calculate the performance by using these values. Then compare the performance parameters for both the systems. 52

Table 1: Comparison of performance parameters for existing and proposed systems S.No. Parameter Existing System Proposed System 1 Net Refrigerating Effect 180 198 2 Coefficient of Performance 2.76 3.19 3 Mass flow rate to obtain 1 T.R. kg/min 1.167 1.15 4 Work of the compressor in KJ/Kg 65 62 5 Power consumption in KW 1.26 1.198 6 Heat to be rejected in condenser in KJ/Kg 245 275.75 IV. RESULTS AND DISCUSSIONS Various performance parameters for both existing and proposed system are calculated and compare as shown below. Comparison of Coefficient of Performance: The above figure shows the COP of both existing and proposed system. By using this graph it is clearly noticed that the proposed system has higher COP than existing one. The COP is increased by 15.57% from 2.76 to 3.19. By introducing these twisted tapes the thermal boundary layer thickness increases then heat transfer rate increase which intern leads to enhance the COP. 53

Comparison of Net Refrigerating Effect: The above fig shows that the NRE of both existing and proposed system.by using this it is clearly noticed that the proposed system has the high NRE than existing one. The Net Refrigerating Effect is increased by 10% from 180 to 198 KJ/Kg. Due to swirl flow by the twisted tapes the heat rejection ratio increases which leads to intensify the Net Refrigerating Effect. Comparison of Mass flow rate: From the above fig it is clearly noticed that the proposed system has less mass flow rate while comparing with the existing one. The mass flow rate is decreased by 12% from 1.165 to 1.15Kg/min. 54

Comparison of power consumption: From the graph it is clearly noticed that the power required for proposed system is less than the existing system. The power consumption is decreased by 4.92% from 1.26 to 1.19 KW.As the compressor work decreases in the proposed system hence the power required is diminishing. V. CONCLUSION The performance of the refrigeration system is increased by introducing the twisted tapes into the condenser coil. High heat rejection through the condenser helped to increase the COP. These twisted tapes decrease the hydraulic diameter of the flow passage.this flow blockage increases the flow velocity and sometimes leads to secondary flow which further provides a better thermal contact between the surface and the fluid, finally results to a high heat transfer coefficient. In the proposed system the cop is increased by 15.57%, Refrigerating Effect is increased by 10%, Power Consumption is diminished by 4.92%,Work done by the compressor is diminished by 12% and Heat rejection is increased by 12.55%. REFERENCES 1. Prabhakar Ray, Dr. Pradeep Kumar Jhinge, A review paper on heat transfer rate enhancement by wire coil inserts in the tube, International journal of engineering sciences & research technology (2014), Vol.3(6) pp. 238-243. 2. Ponna Sasikumar and Dr.G.Prasanthi, COP improvement of VCR System (R-600a) by using diffuser as a secondary compressor and varying fin space, International Journal of Advanced Engineering Research and Technology,volume 5 Issue11,November 2017,ISSN:2348-8190. 3. B.Santosh Kumar. (2015), Experimental Investigation of Vapour compression system with Spiral shaped condenser, IJRME,02, pp.11-14. 4. S. Eiamsa-ard, C. Thianpong, P. Eiamsa-ard, Turbulentheat transfer enhancement by counter/co-swirling flow in a tube fitted with twin twisted tapes, ExperimentalThermal and Fluid Science 34 (2010) 53 62. 55

5. N.C. Kanojiya, V. M. Kriplani, P. V. Walke, Heat Transfer Enhancement in Heat Exchangers With Inserts: A Review, International Journal of Engineering Research & Technology (2014), Vol. 3 6. Dr. A. G. Matani, Swapnil A. Dahake, Experimental study on heat transfer enhancement in a tube using counter/co-swirl generation, International Journal of Application or Innovation in Engineering & Management (2013), Vol.2 7. C. Thianpong, P. Eiamsa-ard, P. Promvonge, S. Eiamsa-ard, Effect of perforated twisted- tapes with parallel wings on heat transfer enhancement in a heat exchanger tube, Second International Conference on Advances in Energy Engineering (ICAEE 2011). 8. Leonard D. Tijing, Bock Choon Pak, Byung Joon Baek, Dong Hwan Lee, A study on heat transfer enhancement using straight and twisted internal fin inserts, International Communications in Heat and Mass Transfer (2006), Vol. 33, pp. 719-726. 9. Alberto Garcia, Pedro G. Vicente, Antonio Viedma, Experimental study of heat transfer enhancement with wire coil inserts in laminar-transition-turbulent regimes at different Prandtl numbers Experimental study of heat transfer enhancement with wire coil inserts in laminar-transition-turbulent regimes at different Prandtl numbers, International Journal of Heat and Mass Transfer (2005), Vol. 48, pp. 4640-4651. 10. R.L. Webb, Performance evaluation criteria for use of enhanced heat transfer surfaces in heat exchanger design, Int. J. Heat Mass Transfer 24 (1981) 715 726. 11. J.P. Holman, Heat Transfer, ninth ed. McGraweHill,New York, 2002 12. N. Sahiti, F. Durst, A. Dewan, Strategy for selection ofelements for heat transfer enhancement, International Journal of Heat and Mass Transfer 49 (2006) 3392 3400. 13. A. Dewan, P. Mahanta, K. Sumithra Raju, P. SureshKumar, Review of passive heat transfer augmentationtechniques, J. Power Energy 218 (2004) 509 525. 14. P.K.Nagarajan and P.Sivashanmugam, Heat TransferEnhancement Studies in a Circular Tube Fitted withright-left Helical Inserts with Spacer, World Academyof Science, Engineering and Technology 58 2011 15. Bergles, A.E., Blumenkrantz, A.R. Performance evaluation criteria for enhanced heat transfer surfaces. 5th International Heat Conference, Tokyo (1974), Vol.2, pp. 239-243. 56