Impact Of Clinical Alarms On Patient Safety. American College of Clinical Engineering Healthcare Technology Foundation (AHTF)

Similar documents
2011 National Clinical Alarms Survey: Perceptions, Issues, Improvements and Priorities

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

You finally make it home after a long shift, shower,

Why Clinical Alarms are a TOP TEN Hazard

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Focus on Respiratory Care & Sleep Medicine Irvine, CA. Alarm Management. September 14-15, 2018

Improving Alarm Management Utilizing Technology. NJ/DVHIMSS Annual Fall Event. Empowering the New Healthcare Era

Alarm Management. Objectives

Reference Case: Avera Heart Hospital Data-Driven Approach Helps Hospital Build Effective Clinical Alarm Management Program

Managing Clinical Alarms

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

Hospital Ward Alarm Fatigue Reduction Through Integrated Medical Device Instruction and Hospital System Policy

A Novel Approach to Cardiac Alarm Management on Telemetry Units. Medical Device Alarm Safety in Hospitals Joint Commission Webinar May 1, 2013

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

The Joint Commission's National Patient Safety Goal on Alarm Management: How Do We Get Started?

Optimization of Workflow Processes & Resources Through the Focused Deployment of Enabling Technologies

CAMHS Staff Safety Alarm

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Alarms That Deserve Attention. Mike Rayo 3/29/2016

"It's Alarming Simple Steps To Reduce Nuisance Alarms

The Complexity of Clinical Alarm Systems

Ensuring the Effectiveness of Clinical Alarm Systems

AST Guidelines for Best Practices in Alarm Management in the Operating Room

2013 Compliance Report RCW 52.33

NHSScotland Firecode. A Model Management Structure for Fire Safety Version 4. This document forms part of NHSScotland Firecode Edition No

Update and Overview on the NFPA Requirements and Testing for Electronic Safety Equipment

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

Clinical Alarm Management Strategies Meaningful Alerts

Running head: REDUCING THE HARM ASSOCIATED WITH CLINICAL ALARMS 1

Optimizing the Closed Suction Surgical Drainage System

THE LASER COURSE Medical Laser Safety Officer & Surgical Operator/Assistant

FIRE SAFETY 2013 ANNUAL REPORT. Author: Senior Fire Safety Advisor Contact Details for further information: Frank Barrett

TPCA TM PATIENT CONTROLLED ANALGESIA SYRINGE PUMP

Improving Alarm Response in ICU/CCU

Fire FY Performance Plan

Alarm Management Services

URGENT - Field Safety Notice Medical Device Correction

Fire Safety Policy SH HS 06. Version: 4. Summary:

SAPLING HEALTHCARE SOLUTIONS

Alarm Safety in 2017:

Applicable To Employees of the Gundersen St. Joseph s Hospital laboratories and Gundersen Tri-County Hospital laboratories.

SIOUX FALLS FIRE RESCUE STRATEGIC PLAN

Only One in Ten (12%) can Identify Vimy Memorial from a Photo. Public Release Date: April 7, 2016

Functional Versus Schematic Overview Displays: Impact on Operator Situation Awareness in Process Monitoring

The Impact the Reference Standards in the 2012 Edition of NFPA 101 have on the Operation of Health Care Facilities: NFPA 80 and 99

Contents of ANSI/AAMI HE75:2009 Page

FIRE SAFETY AND EVACUATION PLANNING FOR ASSISTED LIVING FACILITIES AND NURSING HOMES

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Framework for Alarm Management Process Maturity

Ontario Homes for Special Needs Association

Standard Development Timeline

RADIATION CONTROL GUIDE

POLICY. Code Announcement means an announcement (e.g. page or strobe light, verbal notification) to commence a Fire Drill without an audible alarm.

AS/NZS IEC :2016

The Contra Costa EMS System and Fire Station Closures: Impact and Mitigation

Sapphire TM. Bring Home The Future Of Infusion Care. Ambulatory Infusion System. > Intuitive, easy-to-use touch screen design

Too Many Alarms: Where Do I Begin?

Burton Hospitals NHS Foundation Trust. On: 27 April Review Date: March Corporate / Directorate. Department Responsible for Review:

Wireless Central Monitoring Unit

Fire Safety Report & Audit

excellence in Dependable Automation The Alarm Shelving ebook

Medical devices and electromagnetic compatibility. Addressing the requirements of IEC , 4 th Edition

FIRE SAFETY POLICY June 2014

Code Technology Committee Meeting #31 March 31-April 1, 2015 Care_WTC Recommendations/Elevators

Code Technology Committee 2006/2007 Cycle Area of study Carbon monoxide alarms Public comments

PERFORMANCE METRICS FOR SAFE LASER OPERATIONS AT SLAC NATIONAL ACCELERATOR LABORATORY 1 Paper # 203

T34TM AMBULATORY SYRINGE PUMP

Universal Tag Locator. Operations management software for process facilities

UCSF 2014 Long Range Development Plan

Medical Gas Inspections and Maintenance Programs. HESNI Annual Conference NIU Conference Center May 10-11, 2018 Presented by Mathis Carlson

Bed-Check. Reducing the Risk of Falls Through Innovative Technology Since 1978

Development and Use of Interdivisional Box Alarm Cards

POLICY. Carbon Monoxide (CO) is an odorless, colorless gas that can cause sudden illness and death. 1

Safety Innovations FOUNDATIONHTSI. Cardiopulmonary Monitors And Clinically Significant Events in Critically Ill Children

2019 Virginia Legislative Priorities and Issues Provided to the Virginia General Assembly

Children s Continence Team Enuresis Alarm Therapy for Bed Wetting

Lecturer: Jim Clauston. Course: QAS 515 Human Factors Engineering in Quality. Term Paper Title: Alarm Management on an Oil & Gas Offshore Platform

<< COMPANY LETTERHEAD >>

FLORIDA MEMORIAL UNIVERSITY ANNUAL CAMPUS SAFETY REPORT

Where Technology Shapes Solutions. Alarm management : Wasn t that problem already solved years ago?

BeneVision Central Monitoring System. Quick Reference Guide

EMERGENCY LOCK DOWN PROCEDURE

Australian/New Zealand Standard

Meeting PHMSA Alarm Management Requirements: How TiPS Can Help

Practical Application of a Failure Modes and Effects Analysis (FMEA) in the Healthcare Setting

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

ANSI/NETA Standards Update

FORT MYERS BEACH FIRE DEPARTMENT JOB DESCRIPTION

Digiplex LED Keypads User s Manual

Regulation of Alarm Remote Notification Systems

NFPA 1616 Standard on Mass Evacuation, Sheltering, and Re-entry Programs 2017 Edition. Dean Larson, Chair NFPA 1616

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

BUILDING CODE COMMISSION

WATER TEMPERATURE MANAGEMENT POLICY

RESPONSIVE. RELIABLE. RESPECTED. Case Study: A 15-Year Public/Private Partnership Goes the Distance

Pump Station Operator Training Checklist

Q&A Session from Alarm Management Workflow Webinar (Apr.24/2013)

POLICY. Number: Title: Laser Safety. Authorization

TRUSTED PRECISION. A HISTORY OF INNOVATION. Valleylab FT10 Energy Platform Product Information Kit

Unwanted Fire Alarms. Marty Ahrens National Fire Protection Association 1 Batterymarch Park Quincy, MA (617)

Transcription:

Impact Of Clinical Alarms On Patient Safety American College of Clinical Engineering Healthcare Technology Foundation (AHTF)

In 2004, the ACCE Healthcare Technology Foundation started an initiative to improve clinical alarms To improve patient safety by identifying issues and opportunities for enhancements in clinical alarm design, operation, responses, communication, and appropriate actions to resolve alarm-related events. Actions: 1) Analysis of adverse event literature and databases 2) Evaluation of previous efforts to improve alarms 3) Feedback from meetings and a national survey 4) Recommendations to improve alarm related patient safety 5) Define future directions for improving clinical alarms

AHTF Clinical Alarms Project Task Force Jennifer Ott, CCE, Director Clinical Engineering, St. Louis University Hospital Thomas Bauld, PhD, Technology Manager, Riverside Health Systems, ARAMARK/CTS Bryanne M. Patail, BS, MLS, FACCE, Biomedical Engineer, US Department of Veterans Affairs, National Center for Patient Safety Izabella A. Gieras, MS, MBA, Clinical Engineering Manager, Beaumont Services Company Marvin Shepard, PE, DEVTEQ Saul Miodownik, MEE, CCE Director. Clinical Engineering Memorial Sloan-Kettering Cancer Center Jeff Heyman, Senior Project Engineer, ECRI Ode Keil, MBA CCE, Dir. of Quality Management, Provena Mercy Medical Center Alan Lipschultz, PE CCE CSP Director, Clinical Engineering Christiana Care Health Services Bruce Hyndman, Director of Engineering Services, Community Hospital of the Monterey (CA) Peninsula William Hyman, PhD, Professor, Biomedical Engineering, Texas A&M University James Keller, Vice President, Health Technology Evaluation and Safety, ECRI Matt Baretich, PE, PhD, President, Baretich Engineering Wayne Morse, MSBME, President, Morse Biomedical Co-chair: Tobey Clark, MS CCE, Director, Instrumentation & Technical Services, University of Vermont Co-chair: Yadin David, PhD, Director of the Biomedical Engineering Department at Texas Children's Hospital

Literature Review

Limitations of clinical alarm systems Difficulty in learning more than 6 different alarm signals Surgery and ICU environment >> 6 different alarms Difficulty in discerning between high and low priority alarms Perceived urgency of alarms may not be consistent with criticality of situation Better safe than sorry mentality increases the number of alarms included in devices Some devices do not need alarms more problems than benefits

Limitations of clinical alarm systems 99.4% of the alarms were determined to be false with less than 1% of all alarms resulting in a change of patient management. American Journal of Emergency Medicine, 2006 False alarms/nuisance alarms Procedures Patient conditions Design High false-positive rates loss of credibility disabling of alarms by medical personnel

Reported Problems

FDA MAUDE Database Review The FDA MAUDE database was queried (2002-2004) using search terms: alarm in the Product Problem field death as the Event Type selection 237 reports were found Of 139 events that could be analyzed: 58 (42%) were related to operator education and training 67 (48%) were related to work conditions or personal problems

ECRI Problem Reporting Systems Database Review Of more than 2,200 reports: 12% include the word alarm in the Problem Description field 64% of the reports involved: Physiologic monitors Ventilators Infusion pumps Physiologic monitors Numerous reports of critical patient events where the monitoring system was reported to produce no alarm Investigation found that alarms were inadvertently disabled Ventilator and Infusion pumps Reports discuss device failures that put the patient at risk, but did not result in an alarm to alert caregivers to the failure

Standards Improvement Efforts

JCAHO s Alarm-Safety Goal 6 Sentinel Event Alert February 26, 2002 Ventilator incidents related to clinical alarms National Patient Safety Goals for 2003 and 2004 Maintenance and care management Focus on alarm-safety was effective in: Raising awareness of deaths and injuries that occur due to ineffective alarms and inappropriate alarm use Promoting a better understanding of the importance of effective alarm management strategies Despite the two year focus on alarm improvement, clinical alarm management still requires attention

Design Standards IEC 60601-1-8 General requirements for alarm systems Only focused alarm standard Defines visual and audible alarm signals that can be used to prioritize degree of urgency Not widely implemented in the U.S. Some devices have the option to employ the IECdefined alarm tones Adopted by the FDA as a reference standard Current AAMI/ANSI standards Do not address the need for prioritization of alarms emitted from different devices Alarms are generally handled on a device-specific basis

Survey

Clinical Alarm Survey Demographics Type of facility and location Job type and experience Questions Strongly Agree- Strongly Disagree Design, Standards, Environment, Care management, Integration Rating as to primary versus secondary issues Nine categories Comment field

Clinical Alarm Survey The survey was completed by 1,327 individuals Nearly all from acute care hospitals Over half of respondents were Registered Nurses (RN s) One-third from critical care units 2/3rds had more than 11 years of experience

Clinical Alarm Survey: Results Summary Biggest issue: False Alarms and Nuisance Alarms Reduce attention and response Disrupt care and reduce trust in alarms The majority support: Smart alarms and alarm integration systems Not reported as significant: Alarm training

Clinical Alarm Survey: Sample Comments Nurses that work around alarm systems e.g. monitors, i.v pumps and etc. tend to tune them out after a while. To many false alarms occur and the nurses find this to interfere with patient care. OR, Clinical Manager Patient care is about people and not machines. Too much reliance on technology. Nurses get technology overload. NEED MORE NURSES PER PATIENT BMET, Clinical Engineering Different alarms for different parameters (HR, SpO2, etc). Increased accuracy of alarms therefore reducing false alarms and staff being 'anesthetized' to alarm RN, OR

Observations

Observations The number and complexity of alarm systems in critical care environments challenge human limits for recognition and action Alarms in critical care environments may not significantly affect care management decisions Alarms are a tool in assessing patient conditions Should be used in conjunction with direct clinical measurements and observations Disagreement about the role of user operation of alarm systems in alarm system performance False alarms - consistently reported as a major issue

Observations If well designed, remote alarm communication devices can be of value Problems occurred when used as primary alert method The IEC/ISO standards are viewed by many as a way to improve alarms by: Standardizing audible and visual alarms Priority and parameter differentiation The alarm problem is a systems issue and actions toward specific areas must consider their impact on the system

Recommendations

Healthcare Recommendations Review and revise existing policies related to clinical alarm management: Use of defaults, changing of alarm limits, expected clinical responses to alarm conditions, & consider institutional/departmental standardization Perform frequent clinical alarm monitoring rounds, to alert users to any variations from unit specific guidelines Develop audit tools to measure compliance with established policies related to clinical alarm management Develop and complete a checklist associated with clinical alarm management and document compliance at shift change Conduct in-service and simulation training associated with new equipment Improve device alarms evaluation prior to purchase

Industry/Standards Recommendations The medical device industry must focus on reduction of false alarms Accurate parameter recognition Smart alarms employing advanced signal processing, event recognition and parameter/alarm integration Usability/human factors design Consider the scientific basis and value of the IEC 60601-1-8 standards Prioritization Annunciation Audible and Visual

Future

Future Actions Widely distribute white paper Data analysis update FDA data 2006 & 2006 Publications Journal of Clinical Engineering Jan/Mar 07 American Journal of Critical Care - TBD 2007 Presentations Colloquium - Responding to Medical Device Incidents American College of Healthcare Executives National Patient Safety Foundation Website updates Re-survey in 2-3 years