CH130ARR-CH130ARFR. Room thermostats for fan-coils, 3 speeds + automatic KIT THERMOSTAT ACTUATOR FAN CONNECTION COLOUR CODE CODE CODE SPEED TYPE

Similar documents
Room thermostats for fan-coils, 3 speeds + automatic

N L L1 C NC 230V MULTI-ZONE WIRELESS CLIMATE CONTROL SYSTEM CH175

Programmable Towel Radiator Manual

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

RADIO WAVE WEEKLY PROGRAMMABLE THERMOSTAT CH150RF

Installer Manual KNX Touchscreen Thermostat

Installer and User Manual. BeSMART. Thermostat WiFi Box and boiler RF receiver. Installer and User Manual ESC MODE SET PROG RESET

Self-learning Room Temperature Controller

DPC-1 Programmable digital thermostat with communication Versión 2.0. Technical Information. Ref: N

OPERATING INSTRUCTIONS

Table 1. Serie of Digital Room Thermostats.

Installation & Operation Instructions

T6865 Series Large LCD Digital Thermostat 24 VAC 2-pipe fan coil control

T-32-TS Touchscreen Thermostat. Installation Manual

TIREE FAN COIL CONTROLLER - T6580

Operating Functions Temperature Parameters

RVL471. Heating controller. G2524en. Installation Instructions. 1 Installation. 2 Commissioning

EKC 347 Liquid Level Controller REFRIGERATION AND AIR CONDITIONING. Manual

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

Owner s Manual. Part Number 33CSSP2-FC BACK LIT LIQUID CRYSTAL DISPLAY MODE BUTTON

Installation Instructions

Sensor Control Panel

T5000 LCD Digital Fan Coil Thermostat

Self-learning Room Temperature Controller

Wireless room thermostat with LCD

Intellicomfort CH140GSM

Installation, Start-Up, and Operating Instructions

T6580 FAN COIL CONTROLLER

OWNER S MANUAL. Part Number P CONTENTS

Installation Settings Guide

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Climatouch /CT03TS/217S31 Programmable Universal Touch Screen thermostat

The Book of AERMEC NRL Sequence of Operation

Installation Instructions

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

RVL470. Heating Controller. Use. Functions. Series B

CTT8 TEMPERATURE MONITOR DEVICE

Installation Instructions

Electronic thermostat for heating system

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CommStat 4. Controller for Redundant Telecom HVAC Systems PRODUCT DATA SHEET. Features and Benefits

ETN1000/MIGA - Operating manual

RVL472. Heating Controller. Building Technologies HVAC Products. Series C. including d.h.w. heating

MO n : 12JMC rév A

Emerson Blue Easy Set 1H/1C

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

Heating and D.h.w. Controller RVL482 Basic Documentation

Wave Series. Installation and User Guide. PE950 Hand-Held Remote Transceiver PE650 Panel-Mounted Transceiver

108A OTP1800. Grid Support. General Description

Installation Settings Guide

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

RVL471 Heating and Domestic Hot Water Controller Basic Documentation

TEC210x-2 Series Networked Thermostats

Easy-Stat. Wireless Programmable Room Thermostat Pt No

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Introduction. OM-THA2

Fire / CO Alarm Interface

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Siemens RDY2000BN. Start Up Guide

High wall fan coils Climmy FHW/FHW-ECM. Technical Catalogue

Installation & Operation Instructions

Self-learning Room Temperature Controller

TH146-N-2H1C. 1. Introduction. 2. Installation. 1.1 Applications. 2.1 Control Module (CT280-2H1C) 1.2 Supplied Parts. 1.

Installation Manual. Zoning Kit

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

Carisma Fly Carisma Fly-ECM. Made in. Italy. High Wall Fan Coil. Air Conditioning ENVIRONMENTAL COMFORT

ONX908PIT-V1-S1-F1/B Modulating Digital Thermostat

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Owner s Manual. Part Number 33CS250-01

2017 EcoFactor, Inc.

Room Unit. Building Technologies SYNERGYR

USER'S MANUAL PU SENS 01 (A11) PU SENS 01 (A19) Sensor Control Panel

TEC2100 Series Networked Thermostats

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

INSTALLATION MANUAL. * If using remote sensors the thermostat must be hardwired. Need Help?

NEW. SkyStar SkyStar ECM. Cassette Fan Coil Units. consumption ECM motors. Low energy. Air Conditioning ENVIRONMENTAL COMFORT

INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

5.5. Other configuration parameters EXCEPTION CODES AUTO DIAGNOSTICS Zoning box control board

TC-PHP01-A, TC-PAC01-A Comfort Series Programmable Thermostat. Owner s Manual

Safety & Installation Instructions

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

Owner s Manual. Part Number 33CS250-RC

Software Version 2.01 LEVEL MONITOR MODEL 220

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

T500 Series Non-Programmable Thermostats

IP65 High Bay Dual Sense Sensor

Room Temperature Controllers

HOME AUTOMATION GUIDE TO THE HOME AUTOMATION SYSTEM

Programmable Electronic Thermostat

DC200 Digital Dispenser Operating Manual

Installation Instructions

OWNER S MANUAL. Part Number P

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

Room thermostat with Auto Timer, Option External Input

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

PRELIMINARY EDITION

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

QAW70. Room Unit. Siemens Building Technologies HVAC Products. for use with heating controllers

Transcription:

CH130ARR-CH130ARFR CH130ARR-CH130ARFR Room thermostats for fan-coils, 3 speeds + automatic CH130A model is a fan-coil 4- or 2-pipe thermostat that allows you to control the ambient temperature both in the heating and cooling modes. Is able to drive one or two valves and also control a 3-speed fan-coil motor, either in manual or automatic mode. CH130ARR has a separately activation unit with two-wire connection, while the CH130ARFR model has the separately activation unit with which communicates via radio frequency (wireless). 135 21 Dimensions (mm) 83 KIT COMPOSITION TABLE KIT THERMOSTAT ACTUATOR FAN CONNECTION COLOUR CODE CODE CODE SPEED TYPE CH130ARR CH130AR CH172D manual + automatic 2 wires white 32

CH130ARR KIT WITH REMOTE RELAY MADE UP OF: CH130AR THERMOSTAT + CH172D ACTUATOR 2 WIRES Mounting Temperature Body admissible Power supply N relay Contacts Protection regulation range temperature rating degree C CH130AR on the wall 2 40 45 C actuator CH172D IP20 CH172D 6-module DIN rail 45 C 230Vac 5 relays 5(3)A 250V~ IP00 *CH172DS is used to control more fan-coils. CH130ARFR RADIO FREQUENCY KIT MADE UP OF: CH130ARF THERMOSTAT + CH172DRF ACTUATOR WIRELESS Mounting Temperature Body admissible Power supply N relay Contacts Protection regulation range temperature rating degree C CH130ARF on the wall 2 40 45 C 2 batteries AA of 1,5V IP20 *CH172DRF 6-module DIN rail 45 C 230Vac 5 relays 5(3)A 250V~ IP00 *To control more fan-coils, always use CH172DRF actuator. 33

CH130ARR-CH130ARFR CH130ARR ELECTRICAL FEATURES Power supply from a remote actuator. Remote actuator with 5 output relays, voltage 250 Vca. Contacts rating 5(3)A. 4-TUBE INSTALLATION 2-wire connection thermostat CH130AR hot water cold water remote actuator ch172d 2-TUBE INSTALLATION 2-wire connection hot cold water thermostat CH130AR remote actuator ch172d 1 2 3 4 1 2 3 4 INPUT CONFIGURATION ON-OFF ESTATE INVERNO ingresso comandato con 24 Vcc ON-OFF summer / winter supplied with 24 Vcc sonde di ripresa comando automatico ESTATE INVERNO contatto finestra/termostato di minima contatto invertito finestra/termostato di minima rerun probes SUMMER-WINTER automatic control minimum window/thermostat contact reverse contact (minimum window/thermostat ) CH130ARFR ELECTRICAL FEATURES Power supply from 2 AA type batteries of 1,5V. Remote actuator with 5 output relays, voltage 250 Vca. Contacts rating 5(3)A. 4-TUBE INSTALLATION hot water cold water thermostat CH130RF remote actuator ch172drf 34

2-TUBE INSTALLATION hot water cold water thermostat CH130RF remote actuator ch172drf INPUT CONFIGURATION 1 2 3 4 1 2 3 4 ON-OFF ESTATE INVERNO ingresso comandato con 24 Vcc ON-OFF summer / winter supplied with 24 Vcc sonde di ripresa comando automatico ESTATE INVERNO contatto finestra/termostato di minima contatto invertito finestra/termostato di minima rerun probes SUMMER-WINTER automatic control minimum window/thermostat contact reverse contact (minimum window/thermostat ) HOMOLOGATION AND STANDARDS Complies with EN 60730-2-9 standards. INSTALLATION The thermostat is supplied complete with a base suitable for mounting on the wall, as well in rectangular or round built-in 3-seat boxes. 60 83,5 MOUNTING HOLES, mm 35

CH130ARR-CH130ARFR OPERATION CH130ARR is supplied from the actuator and is able to drive two valves and also control a 3-speed fan-coil motor. CH130ARFR is supplied with two AA batteries of 1,5V and is able to drive two valves and also control a 3-speed fan-coil motor by means of CH172DRF actuator. The wide display shows the measured temperature, fan speed, the running program and the selected season. The settings and data are stored in a permanent (nonvolatile) memory capable of keeping them even in the absence of power supply or when the batteries are not inserted (according to the model). SUMMER/WINTER SELECTION To switch from the Winter operation (i.e. heating system) to the Summer operation (i.e. cooling system), and vice versa, press the 1+2 button combination. The selected operation mode will be indicated on the display by the Winter or Summer icons. BUTTONS COMBINATIONS 1 fan speed increase button, at the maximum prescribed speed is configured the AUTO operating mode. 2 fan speed decrease button, exits the AUTO mode and decreases the fan speed. 1+2 Summer/Winter switch. 3 temperature value increase button for the selected program. 2+4 Celsius/Fahrenheit switch. 3+4 comfort/economy switch. 4 temperature value decrease button for the selected program. 5 thermostat reset button. visualization (SIGNALS) measured temperature COMFORT symbol ECONOMY symbol SUMMER symbol WINTER symbol fan speed symbol 1 2 3 4 5 OPERATING MODES CH130... thermostats have 3 different operating modes: With the COMFORT operating mode, the thermostat regulates the heating or cooling installation operation in order to always keep the same prescribed comfort temperature. With the ECONOMY operating mode, the thermostat regulates the heating or cooling installation operation in order to always keep the same prescribed economy temperature. (OFF) function can be achieved by setting the fan speed to zero. In this case, the thermostat does not perform the regulation. The system will switch OFF completely and on display will appear the message OFF. FAN SPEED SELECTION Manual: fan speed can be set manually to free fixed levels (minimum, medium, maximum). Auto: if the speed is set in Auto, the thermostat sets automatically the appropriate speed according to the difference between the set-point and the ambient temperature. CH130A thermostat has available a TECHNICAL MENU for adapting to different system types. 36 TECHNICAL MENU SYSTEM TYPE 2-tube system: the thermostat will drive only the valve (on/off type) used for heating both during the heating and the cooling; in fact, the valve will control both hot water and cold water. 4-tube system: the thermostat will drive one valve (on/off type) used for heating, plus one additional valve (on/off type) used for cooling, based on the needs of the environment.

external probe resumption: instead of the probe incorporated into the thermostat, an external probe can be used to read the ambient temperature and carry out heat regulation. Typically, this probe will be positioned under the fan-coil where air is sucked. changeover: the external temperature probe can be placed on the fan-coil delivery tube of a 2-tube system to perform automatic changeover between the Summer operation and the Winter operation. minimum window/thermostat contact: when the contact is open, the thermostat will carry out heat regulation; when it is closed, the heat regulation will not be carried out. inverted minimum window/thermostat contact: the window contact will operate with an inverted logic with respect to the statements made in previous step 3. none: the external probe will not be controlled by the thermostat. display visualization ambient temperature: the ambient temperature will be shown on the display. set-point: the current set point will be shown on the display. Central configuration ON/OFF: in the event that several thermostats have been installed, you may decide either to drive all of them in the normal operation condition (ON) or taking advantage of the OFF function by controlling them through a central point. The thermostat will be configured to OFF when the is powered with 24 V (d.c. with no polarity obligation or a.c.); on the contrary, it will remain active when the is free from voltage. Summer/Winter: as in the previous case, the thermostat will be configured to Summer mode when the is powered with 24 V; on the contrary, it will remain active in the Winter mode when the is free from voltage. none: the thermostat will not carry out any operation, whatever the status. SUMMER VALVE TYPE normally open: in this case, the water flow is normally open and will be closed when the valve is supplied. normally closed: when the valve is energized, it will open the water flow. WINTER VALVE TYPE normally open: in this case, the water flow is normally open and will be closed when the valve is supplied. normally closed: when the valve is energized, it will open the water flow. ambient temperature correction It can be adjusted from 4.0 to 4.0 C. This parameter is used to correct the acquired ambient temperature. In fact, in some installations, the ambient temperature reading may not be satisfying, due to the probe location (i.e. internal or resumption). With this parameter, a constant value upon reading can be added to or subtracted from. Winter lower limit set-point temperature It can be adjusted from 2.0 to 40.0 C. It represents the lower limit for all the set-points (Comfort and Economy) in the heating mode. Winter UPPER limit set-point temperature It can be adjusted from 2.0 to 40.0 C. It represents the upper limit for all the set-points (Comfort and Economy) in the heating mode. Summer lower limit set-point temperature It can be adjusted from 2.0 to 40.0 C. It represents the lower limit for all the set-points (Comfort and Economy) in the cooling mode. Summer upper limit set-point temperature It can be adjusted from 2.0 to 40.0 C. It represents the upper limit for all the set-points (Comfort and Economy) in the cooling mode. changeover lower threshold It can be adjusted from 0 to 24 C. It defines the changeover function lower threshold. Below this temperature, the thermostat will be set to the cooling mode. changeover upper threshold It can be adjusted from 26 to 48 C. It defines the changeover function upper threshold. Above this temperature, the thermostat will be set to the heating mode. 37

A CH130ARR can control up to 5 fan-coil units simultaneously, using only two cables for connecting to the actuators. One of these actuators must be a CH172D, while others, maximum four, will be CH172DS. A CH130ARFR can control an unlimited number of actuators provided that they are located within reception range of 30 meters. CONNECTION EXAMPLE BETWEEN CH130AR+CH172D AND 1 FAN-COIL CONNECTION EXAMPLE BETWEEN CH130AR+CH172D+CH172DS AND FEW FAN-COILS (FROM 2 TO 5) CONNECTION EXAMPLE BETWEEN CH130ARF+CH172DRF AND 4 FAN-COILS FEATURES Auxiliary for minimum window and/or thermostat contact using an external probe. Screwed terminals. double insulation. Dimensions 135 X 83 X 21 mm. 38