Fire Protection. Fire-resistant Glass Range. Pilkington Pyrostop. Pilkington Pyrodur

Similar documents
Fire Protection. Fire-resistant glasses. Pilkington Pyrostop. Pilkington Pyrodur

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass

fire protection glass

fire protection glass

Pilkington K Glass. Pilkington K Glass

FRAMES WINDOWS, DOORS & CONSERVATORIES. Pilkington Decorative Glass Range

Pilkington Decorative Glass Range. Pilkington Texture Glass Pilkington Oriel Collection Pilkington Optifloat Opal

Pilkington K Glass Range

Now is the time to improve the energy efficiency of your home.

SGG CONTRAFLAM SAINT-GOBAIN GLASS PROTECT

Glass Roof Upgrades. The Pilkington Activ Range. The clear choice for conservatories and orangeries.

Iv. 5. FIRE-RESISTANT GLASSES Introduction Pyrobel and Pyrobelite Pyropane 372

Pilkington energikare Advantage. Consumer Cleaning Guidelines

Pilkington Mirropane Chrome Handling and Processing Guidelines

SGG CONTRAFLAM LITE SAINT-GOBAIN GLASS PROTECT

The forecast will always be clear and cool. Pilkington Activ and Pilkington Activ Blue Self-cleaning and Solar Control Glass for conservatories

P.O. Box NL-2665 ZN Bleiswijk Brandpuntlaan Zuid 16 - NL-2665 NZ Bleiswijk The Netherlands

This document is a preview generated by EVS

Protect human life against hazards at refineries and other sensitive. Complete cabin protected against blast, gas, fire and smoke

The ETA route to CE marking from the perspective of the European Commission. G. Katsarakis (DG GROW/C.1)

KEEP THE FIRE FROM SPREADING

HORIZONTAL COMPLEMENT TO THE MANDATES TO CEN/CENELEC CONCERNING THE EXECUTION OF STANDARDISATION WORK FOR

STOPLINE FIRE RATED GLAZED

Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Product Selector. Clear Fire Resistant Glass for the Marine

FIRE-SAFETY OF BUILDINGS:

Window and Door Standards for Performance and Security. Russell Day Senior Technical Officer Glass and Glazing Federation

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

UK Product Guide. Fire Doors.

ProdUCT SeleCTo. Clear Fire resistant Glass

Fire-Rated Glazing Changes in 2012 International Building Code (IBC)

Panic and Emergency Exit Devices

Fire Safety Concept Hotel Jumeirah

ISO INTERNATIONAL STANDARD. Reaction to fire tests for floorings Part 1: Determination of the burning behaviour using a radiant heat source

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Annex to the Accreditation Certificate D PL according to DIN EN ISO/IEC 17025:2005

Contents EN :2006+A2:2016 (E)

BS EN ISO : Fire Tests For Determination Of The Burning Behaviour of Floorings. WF Report Number. Date: 16 th November 2009.

Construction Products Directive

Pilkington Insulight Activ SPECIAL APPLICATIONS. Insulating glass units incorporating the world s first self-cleaning glass.

TEKNISK DOKUMENTATION VENTILATION BG BURCHARTH A/S

BS EN ISO : 2010

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

Research-Scale Fire Performance Evaluation of a Wood Floor Joist/Tin Ceiling Panel Assembly

Silicon Pyranometer GSM xx

This document is a preview generated by EVS

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

BUSHFIRE TEST ON GLAZED VERTICAL ELEMENTS

Convener, CEN/TC226/WG6/TG1

This document is a preview generated by EVS

Chapter Nursing Homes

Test Report No. AJHG FB Date: FEB.17, 2015 Page 1 of 13

Keymark, CE-marking and energy labelling: Acceptance and perspectives

This document is a preview generated by EVS

Construction Products Directive

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Europacable FAQ on CPR Status: 26/01/17

PART 1 GENERAL 1.01 SUMMARY

Controlled Door Closing Devices

EUROPEAN TECHNICAL ASSESSMENT

FIRE DOORS RHUL REQUIREMENTS

english Automotive Invisible safety in car glazing

European Technical Assessment

Sýnishorn Glass in building - Insulating glass units - Part 5: Evaluation of conformity

BS EN ISO : 2010

BS EN ISO : 2010

Technical reference Reference & design

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

TECHNICAL AND USER REQUIREMENTS FOR PERSONAL ALERT SAFETY SYSTEMS

ISO INTERNATIONAL STANDARD

BUSINESS PLAN CEN/TC 72 FIRE DETECTION AND FIRE ALARM SYSTEMS EXECUTIVE SUMMARY

STEEL DUCT - FIRE RATED CLADDING INSTALLATION MANUAL

WORLDWIDE CABLE EXPERTS

MEDIUM-DENSITY HOUSING # 7. Fire safety

FAÇADE FIRE TESTS Towards a new European standard method

Georgios Katsarakis European Commission

BUSINESS PLAN. CEN/TC 336 BITUMINOUS BINDERS Version 2018 EXECUTIVE SUMMARY

Life Safety and Fire Resistant Glazing Systems

Fire classification of construction products and building elements

Your Key to achieving C.E Marking Compliance

Fire-Resistant. Automatic Doors

The Passive Fire Protection Handbook

Freiburg Town Hall. World s first public netsurplus-energy. Location Freiburg im Breisgau, Germany. Built 2017

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

WKE Spelsberg. The name in maintaining electrical integrity.

Schueco Fire and Smoke Protection Systems

DECLARATION OF PERFORMANCE

Type 5 Certifications:

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

C 319/6 Official Journal of the European Union

Sound absorption coefficient Equivalent sound absorption area Sound absorption coefficient Sound absorption class

The Role of Glass in Fire Protection

ASTM E662 TESTING FOR COLE MOTORSPORTS/CM RACING PRODUCTS ON WINDSHIELD TEAROFFS ON ¼ GLASS VTEC # TESTED: MARCH 27, 2009

(Publication of titles and references of harmonised standards under Union harmonisation legislation) (Text with EEA relevance) (2015/C 335/02)

FIRE PROTECTION INNOVATORS IN CABLE MANAGEMENT

El Reno Fire Department Fire Alarm Plan Review Worksheet

EUROPEAN COMMISSION INDUSTRY AND ENTERPRISES DIRECTORATE-GENERAL AMENDMENT TO :

(Notices) NOTICES FROM EUROPEAN UNION INSTITUTIONS, BODIES, OFFICES AND AGENCIES EUROPEAN COMMISSION

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

Transcription:

Fire Protection Fire-resistant Glass Range Pilkington Pyrostop Pilkington Pyrodur P_PS_PD China (08).indd 3 27.11.2008 9:56:37 Uhr

Pilkington Pyrostop and Pilkington Pyrodur Frontpage: International Airport Dusseldorf, Germany. Protection and Fire Safety Save lives Limit fire damage to property and valuables Protect the building s structure Provide escape corridors and protected access for firefighters Transparency and Fire Safety Provide a light and comfortable environment in which to live and work Exploit the flexibility in design that glass offers Benefits Totally clear, unobstructed vision Restrict the spread of flames, smoke and hot gases Tested in the widest range of sizes Provide a wide range of design and application options Limit conductive and radiative heat transfer Suitable for internal, external and even for horizontal applications Excellent sound reduction properties Successfully tested as single and double glazing to various fire test standards Available as insulating glass units to offer fire and impact resistance with additional features, e.g. environmental control Well known and accepted by Fire and Building Control Authorities Fillgree fire walls with Pilkington Pyrodur border the plenar hall of the German Parliament Berlin, Germany.

Extreme fire loads caused by many vehicles; Pilkington Pyrostop with fixed glazing as a proper solution in VW Customer Centre Wolfsburg, Germany. Definitions Integrity 100% 100% The ability of the system to keep back flames, 80% smoke and hot gases. No flaming on the non-fire side within the approved time classification. 60% approx. 50% Insulation 40% 20% Pilkington Pyrodur Pilkington Pyrostop Temperature rise on the unexposed fire side shall not be more than 140 C (average value) or 180 C (maximum individual value) above ambient 0% Fire, without any fireresistant glazing Fire-resistant glazing which remains transparent approx. 10% Fire-resistant glazing with special interlayers approx. 2% Fire-resistant glazing with multiple insulating interlayers Radiant heat transfer after 30 minutes. temperature. Temperature Time Curves in Standard Fire Tests 1000 900 800 Frame Temperature rise in K 700 600 500 400 300 200 100 Test temperature in the furnace Surface temperature of fireresistant glasses remaining transparent in case of a fire * Surface temperature of Pilkington Pyrodur * Surface temperature of Pilkington Pyrostop * 0 10 20 30 40 50 60 70 Time in minutes * on the non-fire side fractured glass foam glass Reaction of Pilkington Pyrostop and Pilkington Pyrodur in case of fire.

The entry of the Press Centre North of Koelnmesse in Cologne, Germany. Although having strict regulations Pilkington fire resistant glass meets demands for more openness and transparency. The Full Range of Fire-resistant Solutions in Glass Pilkington Pyrostop A totally clear glass which provides the complete performance range: insulation and radiant heat protection with integrity behaviour Insulation performance categories rated at 30, 60, 90, 120 and 180 minutes according to the chosen product Interlayers react to the fire to give an opaque insulating shield Available as single or insulating glass units Fully transparent before exposure to fire, provides completely functional design flexibility Worldwide use for over 30 years Combinations Pilkington Pyrostop and Pilkington Pyrodur are designed to be combined with the full range of Pilkington glasses in either insulating units or as monolithic glazing for all glazing applications. This gives full scope to design glazing with thermal insulation, solar control, acoustic insulation, safety and security properties all with built-in high performance fire protection. Pilkington Pyrodur A totally clear glass Resists flames, smoke and hot gases Integrity fire-resistant performance rated at 30 and 60 minutes Interlayer reacts to the fire to produce an opaque barrier to flame and thermal radiation Limits the transmission of conductive and radiant heat from the fire Available as single or insulating glass units

Recommendations and Application Pilkington Pyrostop and Pilkington Pyrodur are suitable for Partition walls for interior use Fixed glazing for interior applications, vertical and horizontal Fire doors with top and/or side lites Window/façade glazings Horizontal and sloped glazings Subject to confirmation of: fire tested assembly/ safety requirement/thermal stress check/wind loading check (façades). Please verify compliance with local regulations. Application Extensively approved in more than 800 fire rated assemblies (by independent authorities worldwide). Details can be provided on request. It is the installer s responsibility to ensure that the glasses are installed in a fully tested and certified glazing system, and that the assemblies meet local regulatory requirements. Meet impact resistance requirements of various levels to various standards. Quality Pilkington Pyrostop and Pilkington Pyrodur are recognised by customers and independent test laboratories all over the world for their reliable and consistent performance in various framing systems and applications. Steel framed, fully glazed, fire doors used as lift lobby and fire escape doors.

This publication gives a general description of the product and materials. It is the responsibility of the users to ensure that their use is appropriate for any particular application and that such application complies with all relevant local and national legislation, standards, codes of practice and other requirements. Pilkington Deutschland AG and its subsidiaries hereby disclaim all liability howsoever arising from any error in or omission from this publication and all consequences of relying on it. Pilkington Pyrostop and Pilkington Pyrodur are registered trade marks of the NSG Group. Pilkington Group Ltd. (Shanghai) Representative Office Fire Protection Unit 2509, Shanghai Maxdo Centre, 8 Xing Yi Road, Shanghai 200336 Telephone +86 (0)21 52 08 00 06 +86 (0)21 52 08 00 55 Fax +86 (0)21 52 08 11 08 CE marking confirms that a product complies with its relevant harmonised European Norm. The CE marking label for each product, including declared values, can be found at www.pilkington.com/ce. Pilkington Deutschland AG Haydnstraße 19 45884 Gelsenkirchen Telephone +49 (0) 209 1 68 0 Fax +49 (0) 209 1 68 20 56 E-Mail brandschutz@pilkington.de www.pilkington.com 4200304/08-08