PART 1 GENERAL 1.01 SUMMARY

Similar documents
PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

PART 1 GENERAL 1.01 SUMMARY

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperLite TM I-XL minute SuperLite TM I-XL IGU minute PART 1 GENERAL

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING SuperClear 45-HS (patent pending)

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Temperature Rise Door Framing

SPECIFICATION SECTION : FIRE RATED GLASS & FRAMING GPX Builders Series Fire Protective

SECTION FIRE-RATED GLASS AND FRAME

A. AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) 101: Appendix Dissimilar Materials.

Questions related to specific materials, methods, and services will be addressed at the conclusion of the presentation.

ARBOR SERIES DIVISION FLEXIBLE WOOD VENEER WALLCOVERING

DETEX ARCHITECTURAL SPECIFICATIONS, June 2012 AO19 SERIES HEAVY DUTY LOW-ENERGY ELECTRIC SWING DOOR OPERATOR

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 10 - SPECIALTIES

ARBOR SERIES WOOD WALLCOVERINGS

ARCHITECTURAL SPECIFICATIONS

SECTION CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL

Objectives. To review updated IBC and fire test requirements when designing for life safety.

1. Portable fire extinguishers. 2. Fire-protection cabinets for portable fire extinguishers.

Fire Protection. Fire-resistant glasses. Pilkington Pyrostop Fire Resistance Glass Pilkington Pyrodur Fire Protection Glass

SECTION REGULATORY REQUIREMENTS. A. Relationship between Code, Ordinances, Standards and Contract Documents

DIVISION 10 SPECIALTIES


Fire-Rated Glazing Changes in 2012 International Building Code (IBC)

B. Shop Drawings: For fire protection cabinets. Include plans, elevations, sections, details, and attachments to other work.

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Report on Public Input June 2014 NFPA 101

Architectural Specification Sheet

c. Oko-Tex (European environmental health standard)

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

SECTION FIRE EXTINGUISHER CABINETS

SECTION (13900) - FIRE SUPPRESSION SYSTEMS

.2 Section Waste Management and Disposal..4 Section Electrical General Requirements.

SECTION GENERATOR PARALLELING CONTROLS

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

SECTION AIR DUCT ACCESSORIES

FIRE SUPPRESSION SPRINKLER SYSTEM

WALLCOVERINGS WALLCOVERINGS

Product Guide Specification

Recommended location under the current MasterFormat 2004 is Section Elevator Door Smoke Containment System.

A. Curtains: Provide curtain fabrics with the following characteristics:

B. Product Data: Provide manufacturers catalogue information. Indicate valve data and ratings.

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

SECTION SECURITY TESTING AND COMMISSIONING

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

Division 21: FIRE SUPRESSION WET-PIPE SPRINKLER PROTECTION SYSTEM. The Academy Sept Table of Contents 1 Division 21

DIVISION 21: FIRE SUPPRESSION SYSTEMS SECTION Fire Protection Systems Protecting Cold Storage and Unheated Warehouses

SECTION GYPSUM PLASTER

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Product Guide Specification

FIRE & LIFE SAFTEY STANDARD

TECHNICAL MANUAL for FIRE TAPE. E-Z TAPING SYSTEM PO BOX GREEN BAY, WI

Fire Rated Door Assemblies: Compliant Designs

Model WS Specific Application Window Sprinklers Horizontal and Pendent Vertical Sidewall 5.6 K-factor General Description

Leading. Click to edit Master subtitle style. 3M Fire Protection Products Awareness & Introduction to 3M Fire Protection Products

SECTION Overhead Coiling Doors

DESIGN & CONSTRUCTION GUIDELINES

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

SECTION OVERHEAD COILING FIRE DOORS

NFPA 80 Overview January 21, 2016

SECTION INTERIOR LIGHTING

SPECIFICATION: ARGONITE Engineered Fire Suppression System

CONTENTS AUTOMATIC TRANSFER SWITCHES

NFPA 2001: Standard for Clean Agent Fire Extinguishing Systems NFPA 70: National Electrical Code (NEC) NFPA 72: National Fire Alarm Code

Write Walls Dry Erase Specification Data (Section 09720)

SECTION ELECTRICAL GENERAL PROVISIONS

D. Reference Standards (Utilize latest editions available):

Design & Construction Standards, Revised January

UNIFIED FACILITIES GUIDE SPECIFICATIONS

ARCHITECT S SPECIFICATIONS For Commercial Vinyl Wallcoverings

SECTION ELECTRIC FLOOR HEATING AND SNOW MELTING EQUIPMENT

The Role of Glass in Fire Protection

PIP PCTPA001 Testing of Process Analyzer Systems

SECTION ELECTRICAL IDENTIFICATION

Springpoint Architects, pc SECTION Childcare Center Architect s Project No TABLE OF CONTENTS Monroe County Comm. Sch. Corp.

APPENDIX C REGULATORY AGENCIES AND INDUSTRY STANDARDS 1.0 APPLICABLE GOVERNMENT CODES AND REGULATIONS

MacroAir AirElite HVLS Fans

ADDENDUM #1: MODIFICATIONS AND ADDITIONS TO CONTRACT DOCUMENTS

University of Houston Master Construction Specifications Insert Project Name SECTION DRY-PIPE FIRE SPRINKLER SYSTEM PART 1 - GENERAL

KINGS COUNTY JAIL EXPANSION PHASE III COUNTY OF KINGS SECTION

SECTION FIRE PROTECTION. A. Examine all conditions as they exist at the project, prior to submitting a bid for the work of this section

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION AUTOMATIC VERTICAL CONVEYOR SYSTEM CLOSURE FIRE BARRIER

Kidde Nitrogen Inert Gas Clean Agent Fire Suppression System

SECTION OVERHEAD COILING FIRE DOORS 641 SERIES OVERHEAD COILING COUNTER FIRE DOORS

SECTION (16460) - LOW-VOLTAGE TRANSFORMERS

SECTION ULTRASONIC TRANSIT TIME CLAMP-ON FLOW MEASURING SYSTEM

University of Rochester October 17, 2008 Brooks Landing Business Center

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

B-LINE SERIES. Product brochure. Firestop

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

SECTION INTRUSION DETECTION SYSTEM

Design, Installation, Inspection, and Maintenance

A. Hydraulic calculations shall be prepared in accordance with Chapter 23 of NFPA 13 with the following exceptions:

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

UFGS (June 2006) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Transcription:

Welcome to the SAFTIFIRST TM Guide Specification System prepared as an aid to specifiers in preparing written construction documents. For specification assistance with specific product applications, please contact SAFTIFIRST TM. To download an electronic copy, please visit www.safti.com. SPECIFICATION SECTION 08 8810: FIRE RATED GLASS & FRAMING SuperLite TM II-XL 120 minute and SuperLite TM II-XL 120 minute with Starphire Ultra-Clear Glass by PPG PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Fire rated glazing 1. SuperLite TM II-XL 120 fire resistive, safety rated glazing material for interior and exterior applications. 2. Applications of fire rated glazing includes: a. Fire rated glazing as sidelites, borrowed lites, windows, transoms and transparent wall applications in fire rated frames. B. Related sections: 1. Section 01 3323: Shop Drawings, Product Data and Samples. 2. Section 08 8000: Glazing. 3. Section 08 5130: Steel Window. 4. Section 08 1110: Steel Doors and Frames. 5. Section 08 1400: Wood Doors and Frames. 6. Section 08 1120: Aluminum Doors and Frames. 7. Section 08 5110: Aluminum Windows. 8. Section 08 1113: Hollow Metal Doors and Frames. 9. Section 08 7000: Finish Hardware. 1.02 REFERENCES A. American Society for Testing and Materials (ASTM): 1. ASTM C1629: Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced Cement Panels. 2. ASTM D4977: Standard Test Method for Granule Adhesion to Mineral Surfaced Roofing by Abrasion. 3. ASTM E119: Methods for Fire Tests of Building Construction and Materials. 4. ASTM E152: Methods for Fire Tests of Door Assemblies. 5. ASTM E163: Methods for Fire Tests of Window Assemblies. 6. ASTM E695: Standard Test Method of Measuring Relative Resistance of Wall, Floor, and Roof Construction to Impact Loading. 7. ASTM E2074: Standard Test Method for Fire Tests of Door Assemblies, including Positive Pressure Testing of Side-hinged and Pivoted Swinging Door Assemblies. 8. ASTM E2010-1: Standard Test for Positive Pressure of Fire Tests of Window Assemblies.. B. National fire Protection Association (NFPA): 1. NFPA 80: Fire Doors and Windows.

2. NFPA 251: Fire Tests of Building Construction and Materials. 3. NFPA 252: Fire Tests of Door Assemblies. 4. NFPA 257: Fire Tests of Window Assemblies. C. Underwrites Laboratories, Inc. (UL): 1. UL 9: Standard for Safety of Fire Tests of Window Assemblies. 2. UL 10 B: Standard for Safety of Fire Tests of Door Assemblies. 3. UL 10 C: Standard for Safety of Positive Pressure Tests of Door Assemblies. 4. UL 263: Fire Tests of Building Construction and Materials. D. Standard Council of Canada: 1. ULC Standard CAN4-S101: Fire Tests of Building Construction and Materials. 2. ULC Standard CAN4-S104: Fire Tests of Door Assemblies. 3. ULC Standard CAN4-S106: Fire Tests of Window Assemblies. E. Consumer Product Safety Commission (CPSC): 1. CPSC 16 CFR 1201: Safety Standard for Architectural Glazing Materials. F. American National Standards Institute (ANSI): 1. ANSI Z97.1: Safety Glazing Materials Used in Buildings - Safety Performance Specifications and Methods of Test. G. Glass Association of North America (GANA) 1. GANA Glazing Manual. 2. FGMA Sealant Manual. H. [American Recovery and Reinvestment Act 1. Section 1605, Title XVI Buy American Provision] I. [Insert building code used by Authority Having Jurisdiction] 1.03 SYSTEM DESCRIPTION A. Performance Requirements: Provide a fire rated glazing manufactured, fabricated and installed to maintain performance criteria stated by manufacturer without defects, damage, or failure. 1. Fire Rating: 120 minutes with hose stream. 2. Fire resistive, safety rated glazing tested in accordance with ASTM E119, NFPA 80, NFPA 251, NFPA 252, NFPA 257, UL 9, UL 10B, UL 10C and UL 263. 3. Meets Level 3 classification for surface abrasion resistance, hard body impact resistance and soft body impact resistance per the test procedure outlined in test method ASTM C1629/C1629M. 4. Testing Laboratory: Fire tests shall be conducted by a nationally recognized independent testing laboratory. B. Listings and Labels: 1. Fire rated glazing shall be under current follow-up services by a nationally recognized independent testing laboratory approved by OSHA and maintain a current listing or certification. Assemblies shall be labeled in accordance with limits of listings.

1.04 SUBMITTALS A. Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedure Section. 1. Shop Drawings: Submit shop drawings showing layouts, profiles and product components. 2. Samples: Submit 12x12 glass samples. 3. Technical Information: Submit latest edition of manufacturer s product data. 1.05 DELIVERY, STORAGE AND HANDLING A. General: Comply with Division 1 Product Requirements Sections. B. Ordering: Comply with manufacturer s ordering instructions and lead-time requirements to avoid construction delays. C. Delivery: Deliver materials to specified destinations in manufacturer or distributor s packaging. D. Storage and Protection: Store off ground, under cover, protected from weather and construction activities and at temperature conditions recommended by manufacturer. 1.06 PROJECT CONDITIONS A. Field Measurements: Verify actual measurements for openings by field measurements before fabrication. Show recorded measurements on shop drawings. Coordinate field measurements and fabrication schedule with construction progress to avoid construction delays. 1.07 WARRANTY A. Project Warranty: Refer to Conditions of the Contract for project warranty provisions. B. Manufacturer s Warranty: Submit, for Owner s acceptance, manufacturer s standard warranty document. Manufacturer s warranty is not intended to limit other rights that the Owner may have under the Contract Documents. 1. Warranty Period: 5 years from date of shipping. PART 2 PRODUCTS 2.01 FIRE RATED GLAZING A. Material: SuperLite TM II-XL 120 minute fire resistive glazing with hose stream. B. Manufacturer: SuperLite TM II-XL as manufactured and distributed by SAFTI FIRST. 1. Contact: 100 N Hill Drive, Suite 12, Brisbane, CA 94005; Telephone 888.653.3333; Fax 888.653.4444; email info@safti.com; Web site www.safti.com

2. Fire rated glass and framing must be provided by a single-source, US manufacturer. Distributors of fire rated glass and framing are not to be considered as manufacturers. C. Design Requirements: 1. Make-up: Must be comprised of an inboard and outboard lite of [clear tempered glass] [Starphire Ultra-Clear Low-Iron Tempered Glass by PPG] protecting a clear, fire resistive, intumescent interlayer. 2. Thickness: 1-1/2 (39 mm) standard profile. 1-1/4 thin profile available. 3. Weight: 12 lbs/sq. ft. in 1-1/2 (39 mm) standard profile. 4. Dimensions: Must meet max. clear view area of 4,876 sq. in., measuring at least 124 in. on the long side. 5. Visible Light Transmission: Must meet [0.81 with clear tempered] [0.89 with Starphire] 6. Solar Heat Gain Coefficient: Must meet 0.27 when used with SuperLite II-XL Starphire insulated with Solarban 70XL. 7. U-Factor: Must meet [0.80 standard] [0.41 when used with SuperLite II-XL clear tempered insulated with Solarban 70XL] [0.25 when used with SuperLite II-XL with Starphire insulated with Solarban 70XL]. 8. NFRC Certifications in conjunction with GPX or CW Framing by SAFTI FIRST. Must be used as an assembly. 8.1. Must meet NFRC 100 rated U-Factor of 0.34 when insulated with Solarban 60. 8.2. Must meet NFRC 200 rated SHGC of 0.27 when insulated with Solarban 60. 8.3. Must meet NFRC 500 rated Condensation Resistance of 55 when insulated with Solarban 60. 9. Sound Transmission Rating: Must provide a minimum of STC 44 Rating in 1-1/2 (39 mm) standard profile. 10. Appearance: Must be tint-free, optically clear fire rated glazing. 11. Fire Rating: Must be fire rated to 120 minutes with hose stream and meet ASTM E-119. 12. Impact Safety Resistance: Must meet CPSC 16 CFR 1201 Cat. I & II and ANSI Z97.1. 13. Surface Abrasion Resistance: Must meet level 3 classification per ASTM D4977. 14. Hard Body Impact Resistance: Must meet level 3 classification per ASTM C1629. 15. Soft Body Impact Resistance: Must meet level 3 classification per ASTM E695. 16. Customization: Available in insulated, energy performance, bullet-resistant, blastresistant, hurricane-resistant, laminated, tinted, patterned, frosted, mirrored, reflective, segmented, decorative and more. D. Manufacturer s Fire Rating Glazing Material: 1. Each piece of fire-rated glazing material shall be labeled with a permanent logo including name of product, manufacturer, testing laboratory, fire rating period and safety glazing standards. 2. Glazing materials installed in Hazardous Locations, subject to human impact, shall be certified and permanently labeled as meeting applicable requirements reference in NFPA 80: a. CPSC 16 CFR 1201 Cat. I & II and ANSI Z97.1. E. Substitutions: No substitutions allowed. 2.02 MATERIALS A. Glazing Accessories: Manufacturer recommended fire rated glazing accessory as follows:

1. Glazing with EPDM tape or other listed flame resistant gasket material and calcium silicate setting blocks. 2.03 RELATED PRODUCTS *********************************************************************************************************** Note: Basis of design for fire rated framing system is GPX Framing as manufactured by SAFTI FIRST TM ********************************************************************************************************************************* A. Glazing shall be installed in an equally rated framing system. 2.04 SOURCE QUALITY A. Obtain fire rated glazing products from a single manufacturer. B. Fabrication Dimensions: Fabricate to approved dimensions. The general contractor shall guarantee dimensions where practicable within required tolerances. PART 3 EXECUTION 3.01 MANUFACTURER S INSTRUCTIONS A. Compliance: Comply with manufacturer s product data including product technical bulletins and installation instructions. 3.02 EXAMINATION A. Site Verification of Conditions: Verify substrate conditions, have been previously installed under other sections, and are acceptable for product installation in accordance with manufacturer s instructions. 3.03 INSTALLATION A. Installation shall be in strict accordance with the fire glazing material manufacturer s specifications. Field cutting or tampering is strictly prohibited. 3.04 CLEANING AND PROTECTION A. Protect glass from contact with contaminating substances resulting from construction operations. Remove such substances by method approved by manufacturer. B. Wash glass on both faces not more than four days prior to date schedule for inspections intended to establish date of Substantial Completion. Wash glass by method recommended by glass manufacturer. C. Remove temporary coverings and protection of adjacent work areas. D. Remove construction debris from project site and legally dispose of debris.

END OF SECTION In the interest of continuous improvement of its product line, SAFTIFIRST TM reserves the right to modify its products composition, colors, textures, sizes, and other physical and performance attributes and these guide specifications at any time. SAFTIFIRST TM makes no expressed or implied warranties regarding content, errors, or omissions in the information presented. Specifications modified or rewritten not in conformance with manufacturer s standard processes, products, and procedures may void warranties and related remedies.