Split Air Conditioner

Similar documents
Split Air Conditioner

Split Air Conditioner

Inverter Room Air Conditioner Installation Manual KSV26CRC, KSV26HRC, KSV35CRC, KSV35HRC, KSV53HRC, KSV62HRC, KSV70CRC, KSV70HRC, KSV80HRC

Fixed Speed Split Room Air Conditioner Installation Manual KSE26CRC, KSE26HRC, KSE35CRC, KSE35HRC, KSE53HRC, KSE62HRC, KSE70CRC, KSE70HRC, KSE88CRC

Split Air Conditioner. Thank you for choosing our product. For proper operation, please read and keep this manual carefully.

Split Air Conditioner

Split Air Conditioner

INVERTER SPLIT - TYPE

ALICE HIGH-WALL DUCTLESS AIR CONDITIONING & HEATING SYSTEM INSTALLATION MANUAL

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Split Air Conditioner. Model: WMI09MH16S WMI12MH16S WMI18MH16S

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

USER'S MANUAL SYMPHONY SERIES ASH-09AISR, ASH-09AISB, ASH-09AISW ASH-13AISR, ASH-13AISB, ASH-13AISW

R32. Installation Manual Split Type Wall Mounted Air Conditioner. This appliance shall be installed in accordance with: REFRIGERANT

INSTALLATION MANUAL COMFORT...BUILT TO LAST. 9,000, 12,000 and 18,000 BTU SINGLE-ZONE DUCTLESS MINI-SPLIT SYSTEM Heat Pump

Split Air Conditioner

ROOM AIR CONDITIONER INSTALLATION MANUAL

OWNER S AND INSTALLATION MANUAL RAV-480FS2B/RAV-480AS2B RAV-600FS8B/RAV-600AS8B

0RGHOV,QGRRU 8QLW MWM36Y3J 2XWGRRU 8QLW MRM36Y3J 11

Split Air Conditioner

MULTI HEAT PUMP PANEL CONSOLE TYPE DUCTLESS INVERTER INDOOR UNIT INSTALLATION MANUAL. Models: CH09MCU230VI CH12MCU230VI CH18MCU230VI

Split Air Conditioner

Notices for installation

Choosing the installation site. Installation. 07 Choosing the installation site

HEAT PUMP INSTALLATION MANUAL

Split Air Conditioner

Split Air Conditioner

SINGLE - ZONE Ductless Split System Heat Pumps Installation, Operation & Maintenance Manual

GENERAL INFORMATION CONTENTS

Owner s Manual. Wall Mounted Unit. Models LIMI-12 / LIMO-12 LIMI-18 / LIMO-18 LIMI-24 / LIMO-24

OWNER S MANUAL ASH-09CS ASH-12CS SLIM SERIE. Before operating the unit please carefully read this manual.

Installation and Operation Manual. CMA12SB-0 Series. Horizontal/Side Discharge Condensing Units

Split Air Conditioner. Model: GSA609AE GSA609AC GSA612AE GSA612AC GSA618AE GSA618AC GSA624AE GSA624AC

SPLIT -TYPE ROOM AIR CONDITIONER

36,000 Btu/hr Mini Split Air Conditioner

FLOOR-STANDING TYPE AIR CONDITIONER INSTALLATION MANUAL

UltraV Series Outdoor Units

Split Air Conditioner

KFTC Series 18,000 to 48,000 Btu/h Cooling Only & Heat Pump INSTALLATION MANUAL

QUICK CONNECT INSTALLATION MANUAL DUCTLESS MINI-SPLIT SYSTEM FOR MODELS: 2PAMSHQC12 2PAMSHQC18 2PAMSHQC24 2PAMSHQC36

CCH mini-splits -13 SEER

OWNER S MANUAL. Split Air Conditioner AIR-MASTER Series MODELS: CH-S07RX4 CH-S09RX4 CH-S12RX4 CH-S18RX4 CH-S24RX4

DAIKIN AIR CONDITIONER

INVERTER SPLIT -TYPE ROOM AIR CONDITIONER

FLOOR-STANDING SPLIT TYPE ROOM AIR CONDITIONER

OWNER S MANUAL. Split Air Conditioner IAPH301A / OAPH301A IAPH361A / OAPH361A

Installation. All about the. of your. Split Type Room Air Conditioner. Refer to Page 2 for table of contents.

Installation manual. Split Type Room Air Conditioner

INVERTER ONE-TWO/ONE-THREE/ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Inverter Air Conditioner Installation Manual GIN 090/GIN 091 GIN 120/GIN 121 GIN 180/GIN 181 GIN 240/GIN 241

Split Inverter Air Conditioner

INSTALLATION MANUAL SPLIT TYPE ROOM AIR CONDITIONER (PART NO )

Installation Manual. WAS / WYS Series. For 9,000-36,000 BTU/hr Systems. Inverter+ and Inverter++ Models

Installation Manual. Floor-Standing Type FLOOR-STANDING TYPE AIR CONDITIONER

Installation Manual INVERTER ONE-TWO/ONE-THREE /ONE-FOUR/ONE-FIVE SPLIT-TYPE AIR CONDITIONER

Installation Manual Super-Slim Four-Way Cassette

Installation Manual SPLIT-TYPE ROOM AIR CONDITIONER

USER'S MANUAL CAESARE SERIES ASH-28AC

R410A SPLIT SERIES DC INVERTER

Mini-Split Air Conditioner

Installation and Operation Manual. SVH Series. Inverter Single Zone Ductless Mini-Split SVH09SA-0 SVH09SA-1 SVH12SA-0 SVH12SA-1 SVH18SA-1 SVH24SA-1

AOYG18LFC OUTDOOR UNIT INSTALLATION MANUAL INSTALLATION MANUAL. For authorized service personnel only. PART NO

USER'S MANUAL CAESAR SERIES ASH-18AC PT, ASH-24AC PT

Room Air Conditioners

Split Air Conditioner

Air Conditioner. user installation & manual manual. imagine the possibilities

Installation Manual. KS Series KS09 KS12 KS18 KS24 KS28. J3387_Kaden_Installer_Manual_ indd 1

TCB-DP22CUL. Drain Pump Kit. Model name : AIR CONDITIONER (SPLIT TYPE) Installation Manual. Installation Manual 2 Air Conditioner (Split type) English

Split Air Conditioner

DUCTLESS MINI-SPLIT INSTALLATION MANUAL COMFORT...BUILT TO LAST

Installation Manual. Aurora Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

DVC/DVH Series. Inverter Single Zone Ductless Mini-Split A-DVC/DVH 09SF A-DVC/DVH 12SF A-DVC/DVH 18SF A-DVC/DVH 24SF

Installation Manual PMV Kit RBM-PMV0363E RBM-PMV0903E

Flex Match Series System-Outdoor Unit

Table of Contents. Installation Manual. Accessories Safety Precautions Installation Overview Installation Diagram.

Models. Indoor Unit. Outdoor Unit

Installation Manual. Forest Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER

Please read this manual carefully before installation and keep it for future reference. CONTENTS. Installation Manual. DIY Series

Operation Area...1 Safety Precautions...2 Parts Name...3 Check Before Operation...4. Operation Method...5 Drainage Option...9

1. BEFORE INSTALLATION

InverterFlex Series Multi-Zone Ducted Indoor Unit B-VFH09DA-1 B-VFH12DA-1 B-VFH18DA-1 B-VFH24DA-1

Split Air Conditioner

Installation Manual. Ceiling & Floor Type CEILING & FLOOR TYPE AIR CONDITIONER

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3B54VA MXZ-4B71VA. English

IOM & Owner s Manual. VFH-B Series. Inverter Multi Zone Ductless Mini-Split A-VFH18DB-1 A-VFH24TB-1.

KTIM. Four-way Cassette Type

AMTCM4H4R24 AMTCM4H4R30 AMTCM4H4R36

SPLIT WALL-MOUNTED AIR CONDITIONER

SPLIT-TYPE ROOM AIR CONDITIONER

AIR CONDITIONER CONSOLE

1. BEFORE INSTALLATION

AIR CONDITIONER CASSETTE

PORTABLE AIR CONDITIONER

AIR CONDITIONER CASSETTE

Installation Manual Forest Series All Model Numbers

Installation Manual. Oasis Series All Model Numbers SPLIT-TYPE ROOM AIR CONDITIONER CS

1. BEFORE INSTALLATION

SPLIT -TYPE ROOM AIR CONDITIONER

OPERATION MANUAL AND INSTALLATION MANUAL

BEFORE USING THE APPLIANCE SAFETY PRECAUTIONS AIR CONDITIONER PRECAUTIONS

Transcription:

Change for Life Split Air Conditioner Installation Manual Residential Air Conditioners MODEL: GWH09MA-A3DNXXA GWC09MA-A3DNXXA GWH12MB-A3DNXXA GWC12MB-A3DNXXA GWH09MB-D3DNXXD GWC09MB-D3DNXXD GWH12MB-D3DNXXD GWC12MB-D3DNXXD GWH18MC-D3DNXXD GWC18MC-D3DNXXD GWH24MD-D3DNXXD GWC24MD-D3DNXXD GWH30LB-D3DNXXE GWC36LB-D3DNXXE GWH36LB-D3DNXXE Note: XX stand for different front panels A1~A9 or B1~B9 or C1~C9 or D1~D9 or E1~E9. Thank you for choosing Residential Air Conditioners,please read this owner s manual carefully before operation and retain it for future reference.

CONTENTS Notices for installation...1 Installation dimension diagram...3 Installation of indoor unit...4 Installation of outdoor unit...7 Check after installation and operation test...9 Installation and maintenance of healthy filter(optional)...10 Configuration of connection pipe and additional volume of refrigerant...11 Never attempt. Be sure to follow this instruction The physical product may differ from the drawing in this manual for different display. If there are some differences between them, please refer to the physical product as the standard. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure they are away from the appliance. Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.

Notices for installation Caution 1. The unit should be installed only by authorized service center according to local or government regulations and in compliance with this manual. 2. Installation must be performed in accordance with the NEC/CEC by authorized person only. 3. Before installing, please contact with local authorized maintenance center. If the unit is not installed by the authorized service center, the malfunction may not be solved due to incovenient contact between the user and the service personnel. 4. When removing the unit to the other place, please firstly contact with the local authorized service center. 5.Warning: Before obtaining access to terminals, all supply circuits must be disconnected. 6.For appliances with type Y attachment, the instructions shall contain the substance of the following. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 7.The appliance must be positioned so that the plug is accessible. 8.The temperature of refrigerant line will be high; please keep the interconnection cable away from the copper tube. 9. The instructions shall state the substance of the following: This appliance is not intended for use by persons(including children)with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. Installation Site Instructions Proper installation site is vital for correct and efficient operation of the unit. Avoid the following sites where: strong heat sources, vapours, flammable gas or volatile liquids are emitted. high-frequency electro-magnetic waves are generated by radio equipment, welders and medical equipment. salt-laden air prevails (such as close to coastal areas). the air is contaminated with industrial vapours and oils. the air contains sulphures gas such as in hot spring zones. corrosion or poor air quality exists. 1. 2. 3. 4. Installation Site of Indoor Unit The air inlet and outlet should be away from the obstructions. Ensure the air can be blown through the whole room. Select a site where the condensate can be easily drained out, and where it is easily connected to outdoor unit. Select a place where it is out of reach of children. Select a place where the wall is strong enough to withstand the full weight and vibration of the unit. 5. Be sure to leave enough space to allow access for routine maintenance. The installation site should be 98.4 inch or more above the floor. 1

Notices for installation 6. Select a place about 3.3ft or more away from TV set or any other electric appliance. 7. Select a place where the filter can be easily taken out. 8. Make sure that the indoor unit is installed in accordance with installation dimension instructions. 9. Do not use the unit in the laundry or by swimming pool etc. Note: Installation Site of Outdoor Unit 1. Select a site where noise and outflow air emitted by the unit will not annoy neighbors. 2. Select a site where there is sufficient ventilation. 3. Select a site where there is no obstruction blocking the inlet and outlet. 4. The site should be able to withstand the full weight and vibration. 5. Select a dry place, but do not expose the unit to direct sunlight or strong wind. 6. Make sure that the outdoor unit is installed in accordance with the installation instructions, and is convenient for maintenance and repair. 7. The height difference between indoor and outdoor units is within16.4ft, and the length of the connecting tubing does not exceed 32.8ft. 8. Select a place where it is out of reach of children. 9. Select a place where the unit does not have negative impact on pedestrians or on the city. Safety Precautions for Electric Appliances 1. A dedicated power supply circuit should be used in accordance with local electrical safety regulations. 2. Don't drag the power cord with excessive force. 3. The unit should be reliably earthed and connected to an exclusive earth device by the professionals. 4. The air switch must have the functions of magnetic tripping and heat tripping to prevent short circuit and overload. 5. The minimum distance between the unit and combustive surface is 4.9ft. 6. The appliance shall be installed in accordance with national wiring regulations. 7. An all-pole disconnection switch with a contact separation of at least 9.8ft in all poles should be connected in fixed wiring. Make sure the live wire, neutral wire and earth wire in the family power socket are properly connected. There should be reliable circuit in the diagram. Inadequate or incorrect electrical connections may cause electric shock or fire. Earthing Requirements 1. Air conditioner is type I electric appliance. Please ensure that the unit is reliably earthed. 2. The yellow-green wire in air conditioner is the earthing wire which can not be used for other purposes. Improper earthing may cause electric shock. 3. The earth resistance should accord to the national criterion. 4. The power must have reliable earthing terminal. Please do not connect the earthing wire with the following: 1 Water pipe 2 Gas pipe 3 Contamination pipe 4 Other place that professional personnel consider is unreliable 5. The model and rated values of fuses should accord with the silk print on fuse cover or related PCB. 2

Installation dimension diagram Indoor unit Installation dimension diagram Space to the ceiling 6inch Above Space to the wall 6inch Above 6inch Above Space to the wall 118 inch 98 Above inch Above Space to the floor Air outlet side Outdoor unit Space to the obstruction 20inch above Air inlet side 12inch above 12inch above Space to the wall 79inch above Air outlet side 20inch above Space to the wall 3

Φ2 3/4 1 3/5 Installation of Indoor Unit Installation of Mounting Plate 1. Mounting plate should be installed horizontally. As the water tray's outlet for the indoor unit is two-way type, during installation, the indoor unit should slightly slant to water tray's outlet for smooth drainage of condensate. 2.Fix the mounting plate on the wall with screws. 3.Be sure that the mounting plate has been fixed firmly enough to withstand about 132.3 lb. Meanwhile, the weight should be evenly shared by each screw. 09K 12K UNIT: Wall the wall 6inch above 5 1/6 21 1/3 6 7/9 10 5/6 Wall Space to the wall 6inch above Φ2 1/6 Φ2 1/6 1 2/3 5 5/8 3 1/7 L eft (Rear piping hole ) 1 2/3 Right (Rear piping hold) 2 27 1/3 7 2/3 18K UNIT: Φ2 1/6 Φ2 1/6 11 3/4 1 7/9 5/9 4 3/4 5 1/2 27 7 1/4 24K UNIT: Φ2 3/4 Φ2 3/4 12 2/5 3 1/2 2 5/9 1 7/9 9 7/10 29 2/5 13 1/10 30K&36K UNIT: Φ2 3/4 11 1/5 12 4/5 2 4 3/25 Fig.5 Unit:inch 4

Installation of Indoor Unit Drill Piping Hole Indoor 1.Slant the piping hole (Ф2 1/6 or Ф2 3/4) on the wall slightly downward Wall pipe to the outdoor side. 2.Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged when passing through the hole. Outdoor Seal pad Ф2 1/6 or Ф2 3/4 1. Installation of Drain Hose Connect the drain hose to the outlet pipe of the indoor unit. Bind the joint with rubber belt. 2. Put the drain hose into insulating tube. outlet pipe of indoor unit outlet pipe of drain hose indoor unit rubber belt outlet pipe of drain hose indoor unit 3. Wrap the insulating tube with wide rubber belt to prevent the shift of insulating tube. Slant the drain hose downward slightly for smooth drainage of condensate. rubber belt insulating tube rubber belt outlet pipe of indoor unit Note: The insulating tube should be connected reliably with the sleeve outside the outlet pipe. The drain hose should be slanted downward slightly, without distortion, bulge or fluctuation. Do not put the outlet in the water. bulge connected insulating tube distortion Flooded Connecting Indoor and Outdoor Electric Wires 1.Open the front panel. 2.Remove the wiring cover and wire clamp. Make the power connection cord pass through the hole at the back of indoor unit. 3.Connect and fix the power connection cord to the terminal board. (As shown in Fig.6) 4.Fix the power connection cord with wire clamp and reinstall wiring cover. Wiring cover Fig.6 outdoor unit connection 5

Installation of indoor unit NOTE: All wires between indoor and outdoor units must be connected by the qualified electric contractor. Electric wires must be connected correctly. Improper connection may cause malfunction. Tighten the terminal screws securely. After tightening the screws, pull the wire slightly to confirm whether it's firm or not. Make sure that the electric connections are earthed properly to prevent electric shock. Make sure that all wiring connections are secure and the cover plates are reinstalled properly. Poor installation may cause fire or electric shock. Installation of Indoor Unit The piping can be output from right, right rear, left or left rear. 1. When routing the piping and wiring from the left or right side of indoor unit, cut off the tailings from the chassis when necessary(as shown in Fig.7) ⑴ Cut off tailing 1 when routing the wiring only; ⑵ Cut off tailing 1 and tailing 2 when routing both the wiring and piping. 2. Take out the piping from body case; wrap the piping, power cords, drain hose with the tape and then make them pass through the piping hole. (As shown in Fig.8) 3. Hang the mounting slots of the indoor unit on the upper hooks of the mounting plate and check if it is firm enough. (As shown in Fig.9) 4. The installation site should be 98.4inch or more above the. floor Fig.7 Right Tailing 2 Gas side piping Tailing 1 insulation 右后 Right rear Fixing hook Mounting plate Fig.9 External connection Gas side piping electric wire Liquid side piping Finally wrap it with tape Water drainage pipe Left Left rear Fig.8 Liquid side Piping insulation Mounting plate Installation of Connection Pipe 1. Align the center of the pipe flare with the related valve. 2. Screw in the flare nut by hand and then tighten the nut with spanner and torque wrench by referring to the following: Indoor unit piping Tube diameter Tightening torque,approximate (N m) Ф6.35(1/4 ) 14~18N m(140-180kgf.cm) Ф9.52(3/8 ) 34~42N m(340-420kgf.cm) Spanner Ф12.7(1/2 ) 49~61N m(490-610kgf.cm) Ф15.88(5/8 ) 68~82N m(680-820kgf.cm) Taper nut Piping Torque wrench NOTE: Connect the connection pipe to indoor unit at first and then to outdoor unit. Handle piping bending with care. Do not damage the connection pipe. Ensure that the joint nut is tightened firmly, otherwise, it may cause leakage. 6

Installation of outdoor unit NOTE: Electric Wiring 1. Remove the handle of right side plate from outdoor unit; 2. Pass power connection cord and power cord through the wire hole; 3. Remove wire clamp, and then connect power connection cord and power cord to the terminal and fix them tightly. Wiring distribution must be consistent with the wiring diagram; 4. Fix power connection cord and power cord with wire clamp; 5. Make sure that the wiring is fixed tightly; 6. Reinstall the wire-passing plate. Incorrect wiring may cause malfunction of spare part. After the wire has been fixed, ensure there is free space between the connection and fixing places on the lead wire. Schematic diagram being reference only, please refer to real product for authentic information. Sketch map of power connection wire: Cable-cross board for 9K 12K models INDOOR UNIT N(1) 2 3 L1 L2 N(1) 2 3 OUTDOOR UNIT power connectioncord for 18K 24K models INDOOR UNIT N(1) 2 3 G N(1) 2 3 L1 L2 OUTDOOR UNIT L1 L2 L2 L1 power cord power connection cord G power cord Wire hole Air purging method: Air purging Air purging method Length of connection pipe Refrigerant charging amount Not longer than 24.6ft Nameplate value Use vacuum pump Nameplate value +20g/m (for 9k 12k 18k heat pump unit 24.6~65.6ft Nameplate value +15g/m (for 18k 24k cool only unit Nameplate value +50g/m (for 24k heat pump unit add 15g/20g/50g of refrigerant for additional 1m of pippe length Use vacuum pump (Note: R410A refrigerant special vacuum pump should be Manifold valve applied for R410A unit.) 1. Connect the charging hose of manifold valve to charging Multimeter port of low-pressure valve. Both high-pressure valve and low-pressure valve must be tighten up). -76cm Hg Lo handle Piezometer Hi handle 2. Connect joint of charging hose to vacuum pump. 3. Fully open Lo (low pressure)handle of manifold valve and start the vacuum pump for vacuum pumping. Charging hose Gas valve Charging hose Vacuum pump Liquid 4. Usually the vacuum pumping time of 2600W AC is about valve 15min. The vacuum pumping time of 5000W AC is about 20min. The vacuum pumping time of 7200W AC is about 30min. Make sure the pressure is -1.0X105pa (-76cmHg). When vacuum pumping is finished, close Lo(low pressure) handle of manifold valve completely to stop the vacuum pump. 7

Installation of outdoor unit 5. Maintain the pressure for a while after finishing vacuum pumping to see if there is leakage of the system. Usually the pressure maintenance time of the air conditioner above 5000W is 5min and the pressure maintenance time of the air conditioner below 5000W is 3min. During pressure maintenance period, the rebound of pressure should not exceed 0.005Mpa (0.11lb). 6. After finishing vacuum pumping, open the liquid valve slightly to release air in order to balance the system pressure and present air inlet when removing the hose. Fully open high-pressure valve and low-pressure valve after removing the hose. 7. Tighten bonnets of high-pressure valve, low-pressure valve and charging port. Leakage test Apply soap water to check whether the joints are leaky. Leak detector can also be applied for leakage test. Leak detection point of indoor unit Leak detection point of outdoor unit Outdoor Condensate Drainage (only for Heat pump unit) During heating operation, the condensate and defrosting water should be drained out reliably through the drain hose. Install the outdoor drain connector in a Φ1 inch hole on the base plate and attach the drain hose to the connector so that the waste water formed in the outdoor unit can be drained out.the hole diameter 25 must be plugged. Drain-water hole Bottom frame Drain plug Drain connecter Hose (available commercially, inner dia. 16mm) Whether to plug other holes will be determined by the dealers according to actual conditions. 8

Check after installation and operation test Check after Installation Items to be checked Has the unit been fixed firmly? Have you done the refrigerant leakage test? Is thermal insulation sufficient? Possible malfunction The unit may drop, shake or emit noise. It may cause insufficient cooling(heating). It may cause condensation. Is water drainage satisfactory? It may cause water leakage. Is the voltage in accordance with the rated voltage marked on the nameplate? Is the electric wiring or piping connection installed correctly and securely? Has the unit been securely earthed? Is the power cord specified? Is the inlet or outlet blocked? It may cause electric malfunction or damage the unit. It may cause electric malfunction or damage the parts. It may cause electrical leakage. It may cause electric malfunction or damage the parts. It may cause insufficient cooling(heating). Is the length of connection pipes and refrigerant capacity recorded? The refrigerant capacity is not accurate. Operation Test 1.Before Operation Test (1)Do not switch on power before installation is finished completely. (2)Electric wiring must be connected correctly and securely. (3)Cut-off valves of the connection pipes should be opened. (4)All the impurities such as scraps and thrums must be cleared from the unit. 2.Operation Test Method (1)Switch on power and press "ON/OFF" button on the wireless remote controller to start the operation. (2)Press MODE button to select the COOL, HEAT (Not available for cooling only unit), FAN to check whether the operation is normal or not. 9

Installation and maintenance of healthy filter(optional) Installation of Healthy Filter 1. Lift up the front panel from its two ends, as shown by the arrow direction, and then remove the air filter. (as shown in Fig.a) Fig. a 2. Attach the healthy filter onto the air filter, (as shown in Fig.b).. Fig. b Air filter Healthy filter 3. Install the air filter properly along the arrow direction in Fig.c, and then close the panel. Fig. c Cleaning and Maintenance Remove the healthy filter and reinstall it after cleaning according to the installation instruction. Do not use brush or hard objects to clean the filter. After cleaning, be sure to dry it in the shade. Service Life The general service life for the healthy filter is about one year under normal condition. As for silver ion filter, it is ineffective when its surface becomes black (green). This supplementary instruction is provided for reference to the unit with healthy filter. If the graphics provided herein are different from the actual product, please refer to the actual product. The quantity of healthy filters is based on the actual delivery. 10

Configuration of connection pipe and additional volume of refrigerant 1. Standard length of connection pipe 5m 7.5m 8m 2. Min length of connection pipe For the unit with standard connection pipe of 5m, there is no limitation for the min length of connection pipe. For the unit with standard connection pipe of 7.5m and 8m, the min length of connection pipe is 3m. 3. Max length of connection pipe Sheet 1 Max length of connection pipe Unit: m Capacity 5000 Btu/h (1465 W) 7000 Btu/h (2051 W) 9000 Btu/h (2637 W) 12000 Btu/h (3516 W) Max length of connection pipe 15 15 15 20 18000 Btu/h (5274 W) 25 Capacity 24000 Btu/h (7032 W) 28000 Btu/h (8204 W) 36000 Btu/h (10548 W) 42000 Btu/h (12306 W) Max length of connection pipe 25 30 30 30 48000 Btu/h (14064 W) 30 4. The calculation method of additional refrigerant oil and refrigerant charging amount after prolonging connection pipe After the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5ml of refrigerant oil for each additional 5m of connection pipe. The calculation method of additional refrigerant charging amount (on the basis of liquid pipe): (1) Additional refrigerant charging amount= prolonged length of liquid pipe additional refrigerant charging amount per meter (2) When the length of connection pipe is above 5m, add refrigerant according to the prolonged length of liquid pipe. The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe. See Sheet 2. 11

Configuration of connection pipe and additional volume of refrigerant Sheet 2. Additional refrigerant charging amount for R22 R407C R410A and R134a Diameter of connection pipe mm Indoor unit throttle Outdoor unit throttle Liquid pipe Gas pipe Cooling only, cooling and heating (g / m) Cooling only (g / m) Cooling and heating (g / Ф6 Ф9.5 or Ф12 20 15 20 Ф6 or Ф9.5 Ф16 or Ф19 50 15 50 Ф12 Ф19 or Ф22.2 100 30 120 Ф16 Ф25.4 or Ф31.8 170 60 120 Ф19-250 250 250 Ф22.2-350 350 350 Note: The additional refrigerant charging amount in Sheet 2 is recommended value, not compulsory. m) 12

GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI Add: West Jinji Rd, Qianshan, Zhuhai, Guangdong, China, 519070 Tel: (+86-756) 8522218 Fax: (+86-756) 8669426 E-mail: gree@gree.com.cn www.gree.com 66163074