ZONING MANAGER PRODUCT DATA GENERAL The Zoning Manager HCM 200D is designed to provide home automation control HCM 200D includes both, the 433 MHZ and 868 MHZ transceiver This provides backward compatibility to all 433 MHz components within the Hometronic family and capabilities to control radiator controllers such as HR 80 and further products based on 868 MHZ technology Due to the modular design and architecture, the HCM 200D can be configured and upgraded according to individual customer requirements It covers a wide range of applications in terms of: Comfort Individual room temperature control for radiators and under floor heating Convenience Shutter, lighting control, appliance and cooling control Security and safety Presence simulation, alarm messages, and sensor contact detection Remote access is possible via phone (internet on request) The HCM 200D user interface is the same as the HCM 200 The programming philosophy combined with the operation keys makes this product easy to program and use FEATURES Usable for upgrading CM Zone applications to expand individual room temperature control for up to 16 zones 433 MHZ and 868 MHZ reliable RF communication utilizing 868 MHZ band with 1% duty cycle limit to minimize communication disturbance High performance: - Up to 1600 switching points - 16 lifestyles with 400 actions - 32 modules for shutter, lighting and appliance control - Up to 16 allocatable sensors - Upgradeable software via download User friendly interface: - backlit display (4 lines, 20 characters) - dial button (turn/press) - ECO and Auto/Manu button - dedicated life style buttons Individual room temperature control for up to 16 different zones (rooms) with radiator and under floor heating control Heating/Cooling functionality Full integration of functionalities: - Local operation lock disables manual overwrite HR 80 optimization - Set point limit min - Set point limit max Window function (set point will be changed if the window is open/closed) Boiler feedback dependent on the set point and on the valve position ( only) Analog output for boiler feedback (MCR36/40/200/ZGxx) Individual shutter and awning control dependent on the time program, brightness and room/outside temperature Individual lighting control dimming function Security and safety functions: - Presence simulation - Detection of sensor contact (water leakage) - Alarm messages sending via phone Appliance control switch ON/OFF electrical devices Water stop control EN0H-0482GE51 R1004
SPECIFICATIONS Operating voltage Power consumption Batteries Battery replacement Dimensions (HxWD) Display 2 V AC/DC 4 VA 3 x size AA, Micro 15 V Program retained in EEPROM 170 x 127 x 40 mm Backlit ( 4 lines, 20 characters per line) Operating temperature to 40 C Shipping and storing Temperature -20 to +70 C Humidity 5 to 93 %, non condensing IP class IP30 Safety class 2 Approval CE, countries outside EU require country specific RF approval RF communication range max 30 m in a residential building environment rage RF operation band LPD (8680 8686) MHZ, 1 % duty cycle ISM 433 MHZ (433150 434,700) 10 % duty cycle Receiver Class 2 APPLICATION EXAMPLES Application overview for Heating, Convenience and Communication based on and includes transceiver + is communicating with and future devices Backward compatible with all devices within the Hometronic family Telecom Network HCI300 HRD20 HA70 HS20 HA30 HD30 HS30 HX10 Communication Internet HR50 HCU30 HCW22 HCF22 Convenience HB05 HB15 HWS40 HCE60 Heating EN0H-0482GE51 R1004 2
HCM 200D Heating application for Under Floor Heating and based on and Zoning Manager HCM 200D Remote set point HCW 22 Remote set point HCU 30 with time program Room sensor HCF 22 Remote set point HCW 23 / Antenna HRA 1 Under floor heating controller HCE 60 HR 80 HR 50 Optional Boiler feedback with boiler relay and analogue output (TW) CM Zone mixed applications for Under Floor Heating and based on Floor xx Floor 2 Floor 1 Under Floor Heating Optional CM67z Zone 1 Zone 1 to 16 Bi directional communication Between and Zone 2 Mixed application for underfloor heating control and enhanced radiator applications with zoning manager up to 16 zones The underfloor can be controlled only with the zone 1 of CM67z because it includes the room sensor and controls for Zone1 Zone 2 controls but alternatively it can be also controlled from The boiler inter lock signal is generated by the CM67z for the zone1 and for zone 2 zone from each radiator controller However the boiler demand signal is also generated by the depending on the heating request of each installed room (zone) The boiler relay is controlled by the CM67z and based on heating demand of the individual zones Zone 1 can be controlled only with CM67z because PWM control of the 3 EN0H-0482GE51 R1004
HCM 200D Enhancement of existing applications for based on Floor xx Floor 2 Floor 1 CM67z Zone 16 Zone 3 Zone 2 Zone 1 Enhancement of existing CM Zone applications with zoning manager for radiator control CM67z will be replaced with Up to 16 zones can be controlled individual The boiler inter lock signal is generated by the Depending on the heating request of each zone the boiler will be controlled via the relay module Up to 4 can send their heating demand signal to the However it can be also a mix between and CM67z where the boiler demand signal will be sent to one The limitation is max 4 controller can communicate to one boiler relay optional control with product mix existing HR50 and based on and Floor xx Floor 2 Floor 1 optional HR50 HR50 Zone 16 Zone 3 Zone 2 Zone 1 Enhancement of existing applications for radiator control with HR50 and The can control still HR50 and the application can be mixed up with The boiler inter lock signal is generated by the However the will be controlled depending on the valve position ( only) The boiler feed back for the HR50 is based on the set points and can control the relay module HS30 or HS20 Recommendation: If HR50 and is used in one application and boiler feed back is required than it should be a separate heating circuit for the HR50 and In case only one heating circuit is available for both devices than the boiler feed back should be requested by the because the boiler is controlled based on the valve position and provides a perfect solution EN0H-0482GE51 R1004 4
5 EN0H-0482GE51 R1004
Honeywell GmbH 71101 Schönaich Böblinger Straße 17 Telephone (+49) (0) 7031 637-01 The right is reserved to make modifications This company is certificated to Honeywell Inc hereby declares that this device complies with the basic requirements and other relevant regulations of guideline 1999/5/EC The declaration of conformity of the product can be requested from the manufacturer Note to non-eu countries: This product may only be used if operation in the 433 MHz and 868 MHz frequency band is permissible EN0H-0482GE51 R1004