Imperial Cal Products, Inc.

Similar documents
Imperial. Cal. Products, Inc. Installation Instructions & Warranty Information. 425 Apollo Street Brea, CA

Imperial. Read Before Starting Installation!

Owner and Maintenance Guide for M Line Range Hoods with M600/M1200 Blowers

Barcelona Collection. Use and handling instructions Mode d emploi et d entretien Instrucciones de uso y mantenimiento

Owner and Maintenance Guide Models Equipped with K250 Blower

PRO VENTILATION HOOD USE AND CARE GUIDE CLEANING, MAINTENANCE, AND MORE

COPPER INSERT INSTALLATION INSTRUCTIONS, USE AND CARE GUIDE

IVI WARNINGS: Must be followed carefully to avoid personal injury. [VL

User s Manual WS-4830SS WS-4836SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-3230SS WS-3236SS WS-3242SS WS-3248SS

User s Manual WS-62N30SS WS-62N36SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WS-63TB36SS WS-63TB42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

User s Manual WALL MOUNT SERIES TABLE OF CONTENTS RA7730SS/RA77B30SS RA7736SS/RA77B36SS RA7742SS/RA77B42SS RA7748SS/RA77B48SS.

XOE30 XOE36 READ AND SAVE THE INSTRUCTIONS FOR RESIDENTIAL COOKING ONLY

User s Manual WS-69TB30 / WS-69TB36 (22 ) WS-69TB42 / WS-69TB48 (22 ) WS-69TS30 / WS-69TS36 (18 ) WS-69TS42 / WS-69TS48 (18 )

User s Manual ISLAND SERIES TABLE OF CONTENTS RA-7630SS RA-7636SS RA-7642SS RA-7648SS. Table of Contents. Safety Information...

Table of Contents. Safety Information Content Checklist Measurements Preparation Installation

UNDER CABINET RANGE HOOD

WS-5530SS WS-5536SS WS-5542SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

UNDER CABINET RANGE HOOD. This manual is made with 100 % recycled paper.

Use and Care & Installation Guide

CLEANING & MAINTENANCE For performance, appearance, and health reasons, clean filter, fan and grease-laden surfaces. Use only a clean cloth and mild d


Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

User s Manual RA-3030SS RA-3036SS. NOTE: This unit was designed for indoor residential use and DUCTED operation only.

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE 06E Series Model 06E Series Model RANGE HOOD LOCATION 1. The range hood must be installed just above the

User s Manual WS-68N30SS WS-68N36SS WS-68N42SS

Use, Care, and Installation Guide

RL Series Commercial/Residential Ventilation Fan Installation Instructions Please Read And Save These Instructions.

User s Manual WS-5830SS WS-5836SS WS-5842SS

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

READ AND SAVE THESE INSTRUCTIONS WARNING! TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS OBSERVE THE FOLLOWING:

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Air-O Ultra Series Range Hoods

2 Finding Information

APPUZO RANGE HOOD INSTALLATION

Bosch ventilation use and care manual DPH36652UC - DPH30652UC

User s Manual. NOTE: This unit does not support ducted operation. For ducted operation, please refer to model WS208L30SS or WS208L36SS

READ AND SAVE THESE INSTRUCTIONS

Integrated Hood Liner

User s Manual HI30SS HI36SS HI42SS NOTE: PLEASE INSPECT HOOD IMMEDIATELY UPON RECEIVING. CLAIM OF DAMAGE AFTER 7 DAYS OF DELIVERY WILL BE DENIED.

INSTALLATION INSTRUCTIONS &USE & CARE GUIDE AL-T7200 Versa BBQ Hood Series

Integrated Hood Liner

AerFlow at ::rangehoods.com is a division of kitchen::accessories U N L I M I T E D

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind 7200 Series BBQ Hood

Section 1 - Safety Information Section 2 - Installation: Wall Mount Hoods Section 3 - Installation: Island Mount Hoods

Professional Built-In Hoods

WALL MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind P7200 Series BBQ Hood

Cooktop Low-Profile Ventilation Hoods

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind L7200 Series BBQ Liner

user manual Model #: BLZ-HOOD

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Euro-style Range Hood ESH5200

Wall Mounted Hoods. Use & Care Page 6. Installation Instructions Page 4. Warranty & Registration Page 9

Surface Is. ASL-E42ASX ASL-E48ASX RANGE HOOD - Installation instructions

Model KER222. BEST BY BROAN P.O. Box 140 Hartford, WI ENGLISH...3 FRANÇAIS...12 ESPAÑOL

Installation. Professional Built-in Hoods

Installation Instructions Renaissance Integrated Hood Liner

Pro Ventilation Hood Liners

Operation Manual RANGE HOOD

Model U102I ENGLISH...2 FRANÇAIS...15 ESPAÑOL A. BEST BY BROAN, P. O. Box 140, Hartford, WI 53027

user manual Model #: BLZ-WVH-42

Viking Use & Care Manual

INSTALLATION INSTRUCTIONS & USE & CARE GUIDE Trade-Wind Professional Series Liners

Viking Use & Care Manual

Installation Instructions

Model: GVA-I 668IS2 GVA-IS2 688I IMPORTANT: READ AND SAVE THESE INSTRUCTIONS. FOR RESIDENTIAL USE ONLY.

READ AND SAVE THESE INSTRUCTIONS COOKING ONLY.! WARNING

Use, Care, and Installation Guide

Use, Care, and Installation Guide

Installation Instructions Preference Wall Mount Range Hood

WARNINGS: Must be followed carefully to avoid personal injury. IMPORTANT: Must be followed carefully to avoid damage or incorrect installation.

Use and Care Manual Island/Wall Hoods. Millennia. Table of Contents

READ AND SAVE THESE INSTRUCTIONS

ISLAND MOUNT RANGE HOOD. This manual is made with 100 % recycled paper. Electronic version of this manual is available at:

Tilt ATI-M90ASX ATI-M90ABX RANGE HOOD - Installation instructions

Use & Care Manual. Professional Indoor & Outdoor Hoods. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

Use, Care, and Installation Guide

READ AND SAVE THESE INSTRUCTIONS Installer: Leave this manual with homeowner.

Installation Instructions and Use and Care

GE Monogram. Owner s Manual. Downdraft Vent System.

Installation Instructions. Millennia Island (Ceiling Mount) Range Hoods. Models: DHI361, DHI421, DHI482 and DHI542

Operating and Installation Instructions

Use, Care, and Installation Guide

MO EL: DEL: BUILT-IN INSERTA PLUS 28" & 36"

CHIMNEY RANGE HOODS MODELS VJ603302SS & VJ604302SS

Use and Care Manual Glass Wall Mount Range Hood

Use and Care Manual Downdraft Raised Vent

CHIMNEY RANGE HOODS MODELS VJ51030SS AND VJ51036SS

Owner s Manual. Stainless Steel Range Hood ZV750 ZV850. ge.com

Use & Care. Professional Indoor & Outdoor Hoods

Viking Use & Care Manual

VJ504302SS CHIMNEY RANGE HOOD

395 CFM Code Compliant

MODEL: AN-1145 Glass Canopy 30"

MH70230AS MH70236AS MH70248AS

All (3 and 4) Models 390CFM Code Compliant

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

MODEL: AN-1129 Pryamid 30

USER GUIDE - TOUCH GLASS CONTROLS

INSTALLATION INSTRUCTIONS

Transcription:

Imperial Cal Products, Inc. Read Before Starting Installation! Inspect your range hood prior to installing! Any cosmetic defects must be reported to us prior to installation. Once this hood is installed, ICP will NOT accept any responsibility for any cosmetic blemishes, scratches or dents in the Canopy. Save all original packaging if you wish to return for any reason! FIRST: Check your local building and electrical codes. WARNING: To reduce the risk of fire or electrical shock, Do Not use any two speed motor units with a Solid State control devise. CAUTION: To reduce the risk of fire or personal injury and to properly exhaust air, be sure to duct air to the outside. DO NOT vent exhaust air into spaces within wall, attics, ceilings, crawl spaces or garages. When venting to the outside make duct run as short and straight as possible. Avoid using elbows if at all possible. If elbows are used, we recommend that the first elbow is 24 from vent opening on the hood (minimum of 6 )and at least 24 between it and the next elbow. We strongly recommend no more then two 90 degree elbows in any duct run. No Performance Warranty when used above BBQ Style Grills. DO NOT use duct pipe smaller than the outlet duct opening on the hood, this will reduce performance and void the warranty. DO NOT use flex ducting. Also, use either a Roof Cap or Wall Cap to end run. Be sure that all joints are taped securely in place. It is essential to have the proper distance between the bottom of the range hood and the cooking surface below. In most cases the cooking appliance manufacturers specifications will establish the fire safe minimum distance required, although there are other factors to consider: Local Building Codes Cross directional air movements ie: open windows, air conditioning/heating outlets, cooling fans, etc. Overall size of the cooking appliance and surrounding countertop surfaces. Range hood model selected. For best performance distance between cooking surface and the bottom of the hood is 30 and 36. Check local codes and appliance specifications. Keep in mind, increasing the distance will decrease the performance. *REDUCING duct size will VOID Warranty. PROPERTY OF HOME OWNER, DO NOT THROW AWAY!

Slim Line Series Installation Details: MODELS MODELS MODELS N1900T N1900BP1 N1900BP N1900SD4 N1900PS1 N1900PS N1900SD2 CABINET: Be sure that the cabinet bottom is level, side to side and front to rear. BP & T: Cut an 8 x 8 hole in the bottom of the cabinet, 3/4 in from the rear wall and on center line.bp1: Cut an 8 x 8 wide hole that is 4.25 off center in the bottom of the cabinet, 3/4 in from the wall. Shelves and top to be cut to clear 7 round pipe to line up with the bottom cabinet cut out. Also, cut holes for electrical wires. The location of the cut out determined by the model you are installing. ELECTRICAL: Stub enough wire into cabinet to reach in front of vent pipe. Enter cabinet 2 left (facing hood) of center and 1-1/8 from wall. Remove splice box cover before mounting. MOUNTING: Remove black tape holding dampers closed. Insert canopy below the cabinet, being sure your vent opening and electrical cut outs line up with cabinet cut outs. Use the Key Hole mounting holes to secure the canopy. After hood is mounted attach house wires to leads in the hood. Secure locknut to conduit and check wiring for compliance to local building codes. FINISH: Replace splice box cover. Connect duct and tape all joints. Replace Filters. NOTE: Blower on T model only - blower is offset to the right. Majority of airflow will be on right side of hood. 1" Center Line 9" 4-1/4" 3/4" 4-1/4" 7" 6-1/16" (+/- 1/16") 18" or 22" 7/8" N1900T 11-3/4" 9-1/8" N1900BP1 N1900PS1 29-13/16", 35-13/16", 41-13/16" or 47-13/16" (+/- 1/16") 2" WARNING: To reduce the risk of fire or electrical shock DO NOT use the SD2 series with any solid-state speed control N1900SD2 device. N1900SD4 N1900BP Duct Sizes Indicated in Model # 9" N1900PS 7/8" (Ex: N1942PS-8) 7" ** - 8 = 8 DUCT PIPE 2" 7/8" ** - K=10 DUCT PIPE 6-1/16" (+/- 1/16") 18"or 22" 4-1/4" 3/4" SD Models 1-1/8" BP Models 2" 2" 11-3/4" 9-1/8" 29-13/16", 35-13/16", 41-13/16" or 47-13/16" (+/- 1/16")

Imperial Cal Products, Inc. To order replace parts or schedule service please call our office at (800) 851-4192 or use our website www.imperialhoods.com. PARTS: When ordering Parts we need the following information: Model Number (not serial number) found on UL label inside hood. Exact dimensions (in the case of filters) You can find the model number on the inside of your hood on our UL label. There will be a several model numbers listed, your model number should have a colored dot or mark next to it to indicate the exact model you have. In the case of Filters, we will need the exact dimensions of the filter needed. Indicate which side has the pull tabs on it. Filters are not a warranty replacement part. With care your filters should last many years. Payment on Parts is handled one of three ways: PrePaid (you send a check prior to our Shipping), call with credit card information, VISA or MasterCard, COD or Cash if you decide to Will Call. Our Will Call hours are 8:30 to 3:30, Monday through Friday. SERVICE: When calling in for Service we need the following information: Model Number (not serial number) Proof of Purchase Name of company you purchased the hood through. Name & Phone number of the person to contact to set up the service call. Full address of the location where service is to be done. Warranty is Seven Years, Parts and Labor.

Imperial Cal Products, Inc. Maintenance & Warranty Information This product has the simplest of cleaning requirements. To remove Baffle Filters, remove center panel by pulling panel toward the front of the hood, lift up to remove. Move filters to the center of the hood, pull baffle towards the front of the hood and lift out. To remove grease tray, slide tray to the top of the hood and lift out. Clean filters often for the best performance. How often depends on amount and type of cooking. May be used in the dishwasher, depending on detergents, filters may discolor. When cleaning a painted hood, wash it with mild, soapy water ONLY! Wipe the hood thoroughly with clean water and dry with soft cloth. When cleaning Stainless Steel use a cleaner specifically for Stainless Steel. Always rub with the grain using non-abrasive cleaning materials. AVOID detergents, disinfectants or cleaning products in aerosol cans. NEVER use abrasive scouring powders on your hood! Some cleaning chemicals may damage the hood finish! Center Panel or Front Panel 50 Watt Halogen Flood (Par 20) Recessed (behind grease filters 75 Watt (MAX.) Incandescent (NOT AVAILABLE ON 30 MODELS) ***Bulbs not included on any model.*** Warning: Do not use any bulbs that are not instructed by manufacturer. Do not use Halogen bulbs in sockets not intended for their use! They are to be used only in the Front Light and Center Light Panels. Your Imperial Warranty: Proof of original purchase date is needed to obtain service under warranty. Deluxe Units: Seven Year Limited Warranty, Parts and Labor in the Continental USA. Parts only outside the United States. For seven years from date of original purchase, we will provide parts and service labor in your home to repair or replace any part of the hood that fails due to a manufacturing defect. Call for service at (800) 851-4192 NOTE: Service companies will perform Warranty Service, Monday through Friday from 7 a.m. 4: p.m. The service company will call and schedule a date and time with a 4 hour window. If the service company arrives at your location, during the scheduled date and time, and no one is home, you will be charged a trip charge by the service company for a return service call. ITEMS IMPERIAL WILL NOT PAY FOR 1. Service calls to correct the installation of your appliance, to instruct you how to use your appliance, to replace or repair house fuses or the correct housing wiring or plumbing. 2. Service calls to repair or replace appliance light bulbs or filters. 3. Repairs when your appliance is used for other than normal, single-family household use. 4. Damage resulting from accident, alteration, misuse, abuse, fire, flood, acts of God, improper installation, installation not in accordance with electrical or plumbing codes. 5. Replacement parts or repair costs for units operated outside the United States. 6. Pickup and delivery. This appliance is designed to be repaired in the home. 7. Repairs to parts or systems resulting from unauthorized modification made to the appliance. 8. Expenses for travel and transportation for product service in remote locations. 9. The removal and reinstallation of your appliance if it is installed in an inaccessible location or is not installed in accordance the published installation instructions. 10. Replacement parts or repair labor costs when the appliance is used in a country other than the country in which it was purchased.

SAFETY INSTRUCTIONS Read and Save These Instructions Warning: To reduce the risk of fire, electrical shock or injury to persons, observe the following: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. Before servicing or cleaning unit, switch power off at service panel and lock Service Disconnecting Means to prevent power from being switched on accidentally. When the Service Disconnecting Means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. Warning: To reduce the risk of a range top grease fire: A. Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings. B. Always turn hood ON when cooking at high heat or when Flambéing foods (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambé). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fans or filters. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. Warning: To reduce the risk of injury to persons in the event of a range top grease fire, observe the following: A. SMOTHER FLAMES with a close-fitting lid, cookie sheet or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. B. NEVER PICK UP A FLAMING PAN - you may be badly burned. C. DO NOT USE WATER, including wet dishcloths or towels, violent steam explosion will result. D. Use an extinguisher ONLY if: You know you have a Class ABC extinguisher and you already Know how to use it. The fire is small and contained in the area where it started. The fire department is being called. You can fight the fire with your back to an exit. Warning: To reduce the risk of fire, electrical shock or injury to persons, observe the following: A. Installation work and electrical wiring must be done by a qualified person or persons in accordance with all applicable codes and standards, including fire-rated construction. B. Sufficient air is needed for proper combustion and exhausting of gases through the flue of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American society for Heating, Refrigeration & Air conditioning Engineers (ASHRAE), and the local code authorities. C. When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. Warning: To reduce risk of fire, use only Smooth Metal Ducting! PROPERTY OF HOME OWNER, PLEASE DO NOT THROW AWAY! REV 10/2012

WARRANTY CARD To better serve you with your service and warranty needs, please fill out the purchase and product information and return to Imperial Cal Products. CUSTOMER NAME: PURCHASED FROM: PURCHASE DATE: MODEL #: SERIAL # (Serial # beneath filters on white label) Warranty card can be submitted via our website at: www.imperialhoods.com or by mail. Please keep receipt. Proof of original purchase date is needed to obtain service under warranty. Mail warranty card to: Imperial Cal Products ATTN: Warranty Department 425 Apollo St. Brea, CA 92821 Or visit our website to complete warranty registration: www.imperialhoods.com