Common Control Cards

Similar documents
Alarm Monitoring and Management

Manage Alarms. Before You Begin CHAPTER

Alarm Monitoring and Management

Alarm Monitoring and Management

Manage Alarms. Before You Begin CHAPTER

Alarm Monitoring and Management

GDC 087R Issue 1 - May Installation and Operation UAS Network/Dropside Interface Unit Model NIU/DIU 7624.

High-Speed Voice and Data Link Access Multiplexer

Galaxy Pulsar Plus Digital Battery Plant Controller

USER MANUAL FOR OPERATING SYSTEM

LORAIN CIP 4890/48120 DC Power System

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Analog Input Module IC670ALG630

Fire and Gas Monitoring Panel ST7-HV

RTD TEMPERATURE SENSING SYSTEM

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

ECO N DATE DESCRIPTION OF CHANGE CHG

Added password for IP setup page : Password must be in IP format!

Configuring and Monitoring Alarm

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

LORAIN CSP DC Power System

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Version 1.03 January-2002 USER S MANUAL

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

N-8000 SERIES IP INTERCOM SYSTEM

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

DS1286 Watchdog Timekeeper

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

NU2 Smart Power Supply (SPS) Manual

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

CCU Family of Modules

Power Management and Environmental Monitoring

Installation, Operating and Maintenance Manual

FCD-wire Contents. List of Figures

Galaxy Pulsar Plus Controller Family Troubleshooting Table with SMNP Traps

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

RADview-EMS/TDM. Element Management System for TDM Applications Optimux RAD Data Communications Publication 07/04

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

CARD ACCESS CONTROL SYSTEM

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3 PRODUCT OVERVIEW

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

SMS GSM Alarm Messenger

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

Call stations and extensions

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

QS941A Controller User Interface

RS485 MODBUS Module 8AI

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

Total Access 1500 SCU Installation and Maintenance

16 Zone Voice Evacuation VA & PA Sound System

Addressable Fire Alarm Control Panel

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

CPS3200U Technical Support Guide

Dryer Controller M720

DS1486/DS1486P RAMified Watchdog Timekeeper

MODEL 5100 VOTING LOGIC MODULE

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

OJD ITB No Attachment E Duress Alarm Equipment Specifications

Maintenance Manual ALARM SHELF 19D902821P1 & P2. ericssonz LBI-38496C. TABLE OF CONTENTS (Vendor Documentation)

2000 Series. Program Entry Guide. Control Panels

Voice Alarm. Multifunctional Voice Alarm Systems. certified to EN54

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

TrueAlarm Fire Alarm Systems

Installation Manual COPYRIGHT NOTICE

DUAL MONITORED INPUT/OUTPUT UNIT BN-305

DS1486/DS1486P RAMified Watchdog Timekeepers

Fiber Optical Multiplexer

User Manual. Dryer Controller M720

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Alarms and Surveillance Description

DS7400Xi Addressable Control/ Communicator

Alarm Tone Generator Model AG17

Alarm Panel [ PRELIMINARY HARDWARE MANUAL ] USER MANUAL. v1.0a. May 7, 2008 D-OC-UM

PERMACONN PM1030 Includes DI300. Installation Manual

Connecting and Routing the Cables

TrueAlarm Fire Alarm Controls

WW Ability to connect standalone minives units. Integrated mini PA/VA unit. We make everyday life safer. (incl. fireman and zone microphones)

PACSystems* RX3i. Thermocouple Input Module, 12 Channels, IC695ALG412. GFK-2578B October 2011

Fire Alarm Network Reference

Control/Communicator Installation Manual

System 9000TS Event Recorder

VACIE REFERENCE GUIDE REVISION 1.2.6

System 9000TS Sequence of Events Recorder

M2500 Engine Controller Installation Manual

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

Innovative Circuit Technology Ltd.

An FPGA Spectrum Sensing Accelerator for Cognitive Radio

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION IBAS LIGHTING CONTROL

Fratech Multipath-IP

Installation and user manual for the BiWire / Conventional Repeater Panel

The EN54 Part 2 & 4 Fire System

Installation Guide. Bacharach HGM300 to LonWorks FT-10 Communications Adapter

fmap Log / Troubleshooting Manual Release 8.0 Issue 1

COMPLIANT MANAGER. Installation Manual. Model name: BMS-CM1280TLE BMS-CM1280FTLE. Save These Instructions! ENGLISH

D3000. Installation & Setup Guide

Instruction Manual Model Backup Switch, 1 for 8

Operations Manual TS400. Test Station for G450/G460 Gas Detector

Transcription:

CHAPTER 2 This chapter describes the Cisco ONS 15454 SDH common control card functions It includes descriptions, hardware specifications, and block diagrams for each card For installation and card turn-up procedures, refer to the Cisco ONS 15454 SDH Procedure Guide Chapter topics include: 21 Card Overview, page 2-1 22 Advanced Timing Communications and Control (TCC2) Card, page 2-3 23 Cross Connect XC10G Card, page 2-8 24 Cross Connect XC-VXL-10G Card, page 2-11 25 Cross Connect XC-VXL-25G Card, page 2-14 26 Alarm Interface Controller International Card, page 2-17 21 Card Overview The cards for the ONS 15454 SDH include front mount electrical connection (FMEC) cards, common control cards, electrical cards, optical cards, and Ethernet cards Each card is marked with a symbol that corresponds to a slot (or slots) on the ONS 15454 SDH shelf assembly The cards are then installed into slots displaying the same symbols (refer to the Cisco ONS 15454 SDH Procedure Guide for a list of slots/symbols) The overview in this section provides a summary of the cards 211 Table 2-1 on page 2-2 shows available common control cards for the ONS 15454 SDH Cisco ONS 15454 SDH Reference Manual, R40 2-1

21 Card Overview Chapter 2 Table 2-1 for the ONS 15454 SDH Card TCC2 XC10G XC-VXL-10G XC-VXL-25G AIC-I Description The Advanced Timing Communications and Control (TCC2) card is the main processing center of the ONS 15454 SDH and provides system initialization, provisioning, alarm reporting, maintenance, and diagnostics The 10 Gigabit Cross Connect (XC10G) card is the central element for switching; it establishes connections and performs time-division switching (TDS) The International Cross Connect 10 Gigabit AU3/AU4 high capacity tributary XC-VXL-10G card is the central element for switching; it establishes connections and performs time-division switching (TDS) It enables usage of cards up to a speed of 10 Gbits/s (Gbps) The International Cross Connect 25 Gigabit AU3/AU4 high capacity tributary XC-VXL-25G card is the central element for switching; it establishes connections and performs time-division switching (TDS) It enables usage of cards up to a speed of 25 Gbits/s (Gbps) The Alarm Interface Controller International (AIC-I) card provides customer-defined alarm input/output (I/O), supports user data, and supports local and express orderwire For Additional Information See the 22 Advanced Timing Communications and Control (TCC2) Card section on page 2-3 See the 23 Cross Connect XC10G Card section on page 2-8 See the 24 Cross Connect XC-VXL-10G Card section on page 2-11 See the 25 Cross Connect XC-VXL-25G Card section on page 2-14 See the 26 Alarm Interface Controller International Card section on page 2-17 212 Card Power Consumption Table 2-2 shows power consumption per card Table 2-2 Card Power Consumption for the ONS 15454 SDH Card Watts Amperage at 48 V TCC2 2600 054 (043 A at 60 V) Amperage at 405 V BTU/hr 064 888 XC10G 7860 164 194 2684 XC-VXL-10G 8130 169 201 2776 XC-VXL-25G 8130 169 201 2776 AIC-I 800 017 020 273 Fan Tray 48 VDC 5300 110 131 1810 2-2 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 22 Advanced Timing Communications and Control (TCC2) Card The ONS 15454 SDH is a flexible metro optical transport system supporting a wide variety of applications The power consumption of the shelf assembly varies depending upon shelf configuration Design your power distribution network based on your maximum ONS 15454 SDH system power draw, or the ONS 15454 SDH s maximum rated shelf power draw If you select to design your power plant to your maximum planned ONS 15454 SDH system configuration, the Cisco ONS 15454 SDH Reference Manual lists the power consumption for each card that can be used to determine your maximum ONS 15454 SDH system power draw The general guideline for fuse selection is 20 percent above the maximum calculated system power draw If you design your power system to the ONS 15454 SDH s maximum rated shelf power draw, Cisco recommends that you select a power distribution system supporting a minimum capacity of 30 A for each A and B power feeder on each ONS 15454 SDH shelf assembly Feeder lines should be fused at 30 A This recommendation is based on the shelf assembly s current rated maximum power draw of 30 A at 48 VDC The maximum power draw configuration on the ONS 15454 SDH, based on the hardware available with Release 40, requires 30 A at 48 VDC 22 Advanced Timing Communications and Control (TCC2) Card The TCC2 performs system initialization, provisioning, alarm reporting, maintenance, diagnostics, IP address detection/resolution, SDH section overhead (SOH) data communications channel/generic communication channel (DCC/GCC) termination, and system fault detection for the ONS 15454 SDH The TCC2 also ensures that the system maintains Stratum 3 (ITU-T G812) timing requirements It monitors the supply voltage of the system Figure 2-1 on page 2-4 shows the TCC2 faceplate and Figure 2-2 on page 2-5 shows a block diagram of the card The TCC2 card can work with the XC10G, XC-VXL-10G, or XC-VXL-25G cross-connect cards It requires Software Release 400 or later The LAN interfaces of the TCC2 card meet the standard Ethernet specifications by supporting a cable length of 100 m (328 ft) at temperatures from 0 to 65 degrees Celsius (32 to 149 degrees Fahrenheit) The interfaces can operate with a cable length of 10 m (328 ft) maximum at temperatures from 40 to 0 degrees Celsius ( 40 to 32 degrees Fahrenheit) The TCC2 has been designed to support both 48 VDC and 60 VDC input requirements Cisco ONS 15454 SDH Reference Manual, R40 2-3

22 Advanced Timing Communications and Control (TCC2) Card Chapter 2 Figure 2-1 TCC2 Faceplate TCC2 FAIL PWR A B ACT/STBY CRIT MAJ MIN REM SYNC ACO ACO LAMP RS-232 TCP/IP 83628 2-4 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 22 Advanced Timing Communications and Control (TCC2) Card Figure 2-2 TCC2 Block Diagram RAM Flash DCC Processor 10BaseT Modem Ethernet Hub Timing Controller Framer/ LIU RAM Flash Control Processor 10BaseT Craft B a c k p l a n e Message Router TDM/SCC Mux Voltage Monitoring TDM Crossconnect 83629 221 TCC2 Functionality The TCC2 supports multichannel, high-level data link control (HDLC) processing for the DCC/GCC Up to 32 DCCs/GCCs can be routed over the TCC2 and up to 32 DCCs/GCCs can be terminated at the TCC2 (subject to the available optical digital communication channels) The TCC2 selects and processes 32 DCCs/GCCs to facilitate remote system management interfaces The TCC2 hardware is prepared for 84 DCCs/GCCs, which will be available in a future software release The TCC2 also originates and terminates a cell bus carried over the module The cell bus supports links between any two cards in the node, which is essential for peer-to-peer communication Peer-to-peer communication accelerates protection switching for redundant cards The node database, IP address, and system software are stored in TCC2 nonvolatile memory, which allows quick recovery in the event of a power or card failure The TCC2 performs all system-timing functions for each ONS 15454 SDH The TCC2 monitors the recovered clocks from each traffic card and two building integrated timing supply (BITS) ports for frequency accuracy The TCC2 selects a recovered clock, a BITS or an internal Stratum 3 reference as the system-timing reference You can provision any of the clock inputs as primary or secondary timing sources A slow-reference tracking loop allows the TCC2 to synchronize with the recovered clock, which provides holdover if the reference is lost Cisco ONS 15454 SDH Reference Manual, R40 2-5

22 Advanced Timing Communications and Control (TCC2) Card Chapter 2 The TCC2 monitors both supply voltage inputs of the shelf An alarm is generated if one of the supply voltage inputs has a voltage out of the specified range Install TCC2 cards in Slots 7 and 11 for redundancy If the active TCC2 fails, traffic switches to the protect TCC2 All TCC2 protection switches conform to protection switching standards when the bit error rate (BER) counts are not in excess of 1 * 10 exp 3 and completion time is less than 50 ms The TCC2 card has two built-in interface ports for accessing the system: an RJ-45 10BaseT LAN interface and an EIA/TIA-232 ASCII interface for local craft access It also has a 10BaseT LAN port for user interfaces via the backplane to the port accessible on the front of the MIC-C/T/P FMEC Cisco does not support operation of the ONS 15454 SDH with only one TCC2 card For full functionality and to safeguard your system, always operate in a redundant configuration CTC software does not monitor for the presence or absence of FMECs unless the TCC2 card(s) have reached the Active/Standby state During transitional states such as power-up or TCC2 reset, CTC ignores the FMEC inventory displayed in node view When a second TCC2 card is inserted into a node, it synchronizes its software, its backup software, and its database with the active TCC2 If the software version of the new TCC2 does not match the version on the active TCC2, the newly inserted TCC2 copies from the active TCC2, taking about 15 to 20 minutes to complete If the backup software version on the new TCC2 does not match the version on the active TCC2, the newly inserted TCC2 copies the backup software from the active TCC2 again, taking about 15 to 20 minutes Copying the database from the active TCC2 takes about 3 minutes Depending on the software version and backup version the new TCC2 started with, the entire process can take between 3 and 40 minutes 222 TCC2 Card-Level Indicators The TCC2 faceplate has eight LEDs The first two LEDs are card-level indicators These indicators are described in Table 2-3 Table 2-3 TCC2 Card-Level Indicators Card-Level LEDs Red FAIL LED ACT/STBY LED Green (Active) Yellow (Standby) Definition This LED is lit during reset The FAIL LED flashes during the boot and write process Replace the card if the FAIL LED persists The ACT/STBY (Active/Standby) LED indicates the TCC2 is active (green) or in standby (yellow) mode The ACT/STBY LED also provides the timing reference and shelf control When the TCC2 is writing to the active or standby TCC2, its active or standby LED blinks To avoid memory corruption, do not remove the TCC2 when the active or standby LED is blinking 2-6 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 22 Advanced Timing Communications and Control (TCC2) Card 223 System-Level Indicators The TCC2 faceplate has eight LEDs Six LEDs are system-level indicators These indicators are described in Table 2-4 Table 2-4 TCC2 System-Level Indicators System-Level LEDs Red CRIT LED Red MAJ LED Yellow MIN LED Red REM LED Green SYNC LED Green ACO LED Definition Used to indicate critical alarms in the network at the local terminal Used to indicate major alarms in the network at the local terminal Used to indicate a minor alarm in the network at the local terminal Provides first-level alarm isolation The remote (REM) LED turns red when an alarm is present in one or several of the remote terminals Used to indicate that node timing is synchronized to an external reference After pressing the alarm cutoff (ACO) button, the green ACO LED illuminates The ACO button opens the audible closure on the backplane ACO state is stopped if a new alarm occurs After the originating alarm is extinguished, the ACO LED and audible alarm control are reset 224 TCC2 Card Specifications The TCC2 card has the following specifications: CTC software Interface: EIA/TIA-232 (local craft access, on TCC2 faceplate) Interface: 10BaseT LAN (on TCC2 faceplate) Interface: 10BaseT LAN (via backplane, access on the MIC-A/P card) Synchronization Stratum 3, per ITU-T G812 Free running access: Accuracy +/ 46 ppm Holdover stability: 37 * 10 exp 7 per day including temperature (< 255 slips in first 24 hours) Reference: External building integrated timing source (BITS), line, internal Supply voltage monitoring Both supply voltage inputs are monitored Normal operation: 405 to 567 V (in 48 VDC systems) 500 to 720 V (in 60 VDC systems) Undervoltage: Major alarm Overvoltage: Major alarm Environmental Operating temperature: 40 to +65 degrees Celsius ( 40 to +149 degrees Fahrenheit) Operating humidity: 5 to 95%, noncondensing Power consumption: 2600 W, 054 A at 48 V, 043 A at 60 V, 888 BTU/hr Cisco ONS 15454 SDH Reference Manual, R40 2-7

23 Cross Connect XC10G Card Chapter 2 Dimensions Height: 3213 mm (12650 in) Width: 182 mm (0716 in) Depth: 2286 mm (9000 in) Depth with backplane connector: 235 mm (9250 in) Weight not including clam shell: 07 kg (15 lb) Compliance ONS 15454 SDH cards, when installed in a system, comply with these standards: Safety: IEC 60950, EN 60950, UL 60950, CSA C222 No 60950, TS 001, AS/NZS 3260 23 Cross Connect XC10G Card The XC10G card cross connects STM-1, STM-4, STM-16, and STM-64 signal rates The XC10G provides a maximum of 384 x 384 VC-4 nonblocking cross connections Any STM-1 on any port can be connected to any other port, meaning that the STM cross-connections are nonblocking The XC10G faceplate is shown in Figure 2-3 on page 2-9 The XC10G cross-connects are shown in Figure 2-4 on page 2-9 A block diagram of the card is shown in Figure 2-5 on page 2-10 The lowest level cross-connect with XC10G is STM-1 Lower level signals, such as E-1, DS-3, or E-3, can be dropped This might leave part of the bandwidth unused 2-8 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 23 Cross Connect XC10G Card Figure 2-3 XC10G Faceplate XC10G FAIL ACT/STBY 55042 Figure 2-4 XC10G Cross-Connect Matrix XC10G Cross-connect ASIC (384x384 VC-4) 8X STM-16 Input Ports 1 2 Output Ports 1 2 8X STM-16 4X STM-64 25 25 4X STM-64 61252 Cisco ONS 15454 SDH Reference Manual, R40 2-9

23 Cross Connect XC10G Card Chapter 2 Figure 2-5 XC10G Block Diagram Line 1 Line 2 Line 3 up Interface Line 4 Span 1 Span 2 Cross-Connect Matrix Span 3 Span 4 Line 5 Flash Line 6 Line 7 Line 8 Ref Clk A Ref Clk B B a c k p l a n e RAM up up Interface TCCA ASIC Main SCL SCL link Protect SCL 61251 The XC10G card manages up to 192 bidirectional STM-1 cross-connects The TCC2 assigns bandwidth to each slot on a per STM-1 basis The XC10G card works with the TCC2 card to maintain connections and set up cross-connects within the system Depending on requirement in the node, one of the XC10G, XC-VXL-10G, or XC-VXL-25G card types is required to operate the ONS 15454 SDH You can establish cross-connect and provisioning information through the Cisco Transport Controller (CTC) The TCC2 establishes the proper internal cross-connect information and sends the setup information to the XC10G cross-connect card Cisco does not recommend nor support operating the ONS 15454 SDH with only one XC10G card To safeguard your system, always operate in a redundant configuration 231 XC10G Card-Level Indicators The XC10G faceplate has two card-level LEDs, described in Table 2-5 on page 2-11 2-10 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 24 Cross Connect XC-VXL-10G Card Table 2-5 XC10G Card-Level Indicators Card-Level LEDs Red FAIL LED ACT/STBY LED Green (Active) Yellow (Standby) Definition The red FAIL LED indicates that the card s processor is not ready This LED is lit during reset The FAIL LED flashes during the boot process Replace the card if the red FAIL LED persists The ACT/STBY (active/standby) LED indicates whether the XC10G is active and carrying traffic (green) or in standby mode to the active XC10G card (yellow) 232 XC10G Card Specifications The XC10G card has the following specifications: Environmental Operating temperature: 5 to +45 degrees Celsius (+23 to +113 degrees Fahrenheit) Operating humidity: 5 to 85%, noncondensing Power consumption: 7860 W, 164 A at 48 V, 2684 BTU/hr Dimensions Height: 3213 mm (12650 in) Width: 182 mm (0716 in) Depth: 2286 mm (9000 in) Depth with backplane connector: 235 mm (9250 in) Weight not including clam shell: 06 kg (15 lb) Compliance ONS 15454 SDH cards, when installed in a system, comply with these standards: Safety: IEC 60950, EN 60950, UL 60950, CSA C222 No 60950, TS 001, AS/NZS 3260 24 Cross Connect XC-VXL-10G Card The XC-VXL-10G card cross connects E-1, E-3, DS-3, STM-1, STM-4, STM-16, and STM-64 signal rates The XC-VXL-10G provides a maximum of 384 x 384 VC-4 nonblocking cross connections, 384 x 384 VC-3 nonblocking cross connections, or 2016 x 2016 VC-12 nonblocking cross connections It is designed for 10-GBits/s (Gbps) solutions The XC-VXL-10G faceplate is shown in Figure 2-6 on page 2-12 The XC-VXL-10G cross-connects are shown in Figure 2-7 on page 2-12 A block diagram of the XC-VXL-10G is shown in Figure 2-8 on page 2-13 Cisco ONS 15454 SDH Reference Manual, R40 2-11

24 Cross Connect XC-VXL-10G Card Chapter 2 Figure 2-6 XC-VXL-10G Faceplate XCVXL 10G FAIL ACT/STBY 83418 Figure 2-7 XC-VXL-10G Cross-Connect Matrix XC-VXL-10G Cross-connect ASIC (384x384 VC-3/4, 2016x2016 VC-12) Input Ports Output Ports 1 1 8X STM-16 2 2 8X STM-16 4X STM-64 25 25 4X STM-64 83660 2-12 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 24 Cross Connect XC-VXL-10G Card Figure 2-8 XC-VXL-10G Block Diagram Line 1 Line 2 Line 3 up Interface Line 4 Span 1 Span 2 Cross-Connect Matrix Span 3 Span 4 Line 5 Flash Line 6 Line 7 Line 8 Ref Clk A Ref Clk B B a c k p l a n e RAM up up Interface TCCA ASIC Main SCL SCL link Protect SCL 61251 The XC-VXL-10G card manages up to 192 bidirectional STM-1 cross-connects, 192 bidirectional E-3 or DS-3 cross-connects, or 1008 bidirectional E-1 cross-connects The TCC2 assigns bandwidth to each slot on a per STM-1 basis The XC-VXL-10G card works with the TCC2 card to maintain connections and set up cross-connects within the system Depending on requirement in the node, one of the XC10G, XC-VXL-10G, or XC-VXL-25G card types is required to operate the ONS 15454 SDH You can establish cross-connect and provisioning information through the Cisco Transport Controller (CTC) The TCC2 establishes the proper internal cross-connect information and sends the setup information to the XC-VXL-10G cross-connect card Cisco does not recommend nor support operating the ONS 15454 SDH with only one XC-VXL-10G card To safeguard your system, always operate in a redundant configuration The XC-VXL-10G is to be placed in Slots 8 and 10 241 XC-VXL-10G Card-Level Indicators The XC-VXL-10G faceplate has two card-level LEDs, described in Table 2-6 on page 2-14 Cisco ONS 15454 SDH Reference Manual, R40 2-13

25 Cross Connect XC-VXL-25G Card Chapter 2 Table 2-6 XC-VXL-10G Card-Level Indicators Card-Level LEDs Red FAIL LED ACT/STBY LED Green (Active) Yellow (Standby) Definition The red FAIL LED indicates that the card s processor is not ready This LED is lit during reset The FAIL LED flashes during the boot process Replace the card if the red FAIL LED persists The ACT/STBY (Active/Standby) LED indicates whether the XC-VXL-10G is active and carrying traffic (green) or in standby mode to the active XC-VXL-10G card (yellow) 242 XC-VXL-10G Card Specifications The XC-VXL-10G card has the following specifications: Environmental Operating temperature: 5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit) Operating humidity: 5 to 85%, noncondensing Power consumption: 8130 W, 169 A at 48V, 2776 BTU/hr Dimensions Height: 3213 mm (12650 in) Width: 182 mm (0716 in) Depth: 2286 mm (9000 in) Depth with backplane connector: 235 mm (9250 in) Weight not including clam shell: 06 kg (15 lb) Compliance ONS 15454 SDH cards, when installed in a system, comply with these standards: Safety: IEC 60950, EN 60950, UL 60950, CSA C222 No 60950, TS 001, AS/NZS 3260 25 Cross Connect XC-VXL-25G Card The XC-VXL-25G card cross connects E-1, E-3, DS-3, STM-1, STM-4, STM-16, and STM-64 signal rates The XC-VXL-25G provides a maximum of 192 x 192 VC-4 nonblocking cross connections, 384 x 384 VC-3 nonblocking cross connections, or 2016 x 2016 VC-12 nonblocking cross connections It is designed for 25-GBits/s (Gbps) solutions The XC-VXL-25G faceplate is shown in Figure 2-9 on page 2-15 The XC-VXL-25G cross-connects are shown in Figure 2-10 on page 2-15 A block diagram of the card is shown in Figure 2-11 on page 2-16 2-14 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 25 Cross Connect XC-VXL-25G Card Figure 2-9 XC-VXL-25G Faceplate XCVXL 25G FAIL ACT/STBY 83419 Figure 2-10 XC-VXL-25G Cross-Connect Matrix XC-VXL-25G Cross-connect ASIC (192x192 VC-4, 384x384 VC-3, 2016x2016 VC-12) Input Ports 1 Output Ports 1 2 2 12X STM-16 12X STM-16 25 25 83661 Cisco ONS 15454 SDH Reference Manual, R40 2-15

25 Cross Connect XC-VXL-25G Card Chapter 2 Figure 2-11 XC-VXL-25G Block Diagram Line 1 Line 2 Line 3 up Interface Line 4 Span 1 Span 2 Cross-Connect Matrix Span 3 Span 4 Line 5 Flash Line 6 Line 7 Line 8 Ref Clk A Ref Clk B B a c k p l a n e RAM up up Interface TCCA ASIC Main SCL SCL link Protect SCL 61251 The XC-VXL-25G card manages up to 192 bidirectional STM-1 cross-connects, 192 bidirectional E-3 or DS-3 cross-connects, or 1008 bidirectional E-1 cross-connects The TCC2 assigns bandwidth to each slot on a per STM-1 basis The XC-VXL-25G card works with the TCC2 card to maintain connections and set up cross-connects within the system Depending on requirement in the node, one of the XC10G, XC-VXL-10G, or XC-VXL-25G card types is required to operate the ONS 15454 SDH You can establish cross-connect and provisioning information through the Cisco Transport Controller (CTC) The TCC2 establishes the proper internal cross-connect information and sends the setup information to the XC-VXL-25G cross-connect card Cisco does not recommend nor support operating the ONS 15454 SDH with only one XC-VXL-25G card To safeguard your system, always operate in a redundant configuration 251 XC-VXL-25G Card-Level Indicators The XC-VXL-25G faceplate has two card-level LEDs, described in Table 2-7 on page 2-17 2-16 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 26 Alarm Interface Controller International Card Table 2-7 XC-VXL-25G Card-Level Indicators Card-Level LEDs Red FAIL LED ACT/STBY LED Green (Active) Yellow (Standby) Definition The red FAIL LED indicates that the card s processor is not ready This LED is lit during reset The FAIL LED flashes during the boot process Replace the card if the red FAIL LED persists The ACT/STBY (Active/Standby) LED indicates whether the XC-VXL-25G is active and carrying traffic (green) or in standby mode to the active XC-VXL-25G card (yellow) 252 XC-VXL-25G Card Specifications The XC-VXL-25G card has the following specifications: Environmental Operating temperature: 5 to +55 degrees Celsius (+23 to +131 degrees Fahrenheit) Operating humidity: 5 to 85%, noncondensing Power consumption: 8130 W, 169 A at 48 V, 2776 BTU/hr Dimensions Height: 3213 mm (12650 in) Width: 182 mm (0716 in) Depth: 2286 mm (9000 in) Depth with backplane connector: 235 mm (9250 in) Weight not including clam shell: 06 kg (15 lb) Compliance ONS 15454 SDH cards, when installed in a system, comply with these standards: Safety: IEC 60950, EN 60950, UL 60950, CSA C222 No 60950, TS 001, AS/NZS 3260 26 Alarm Interface Controller International Card The optional Alarm Interface Controller International (AIC-I) card provides customer-defined alarm I/O, and supports user data and local and express orderwire It provides 16 customer-defined input contacts and 4 customer-defined input/output contacts It requires the MIC-A/P for connection to the alarm contacts Figure 2-12 on page 2-18 shows the AIC-I faceplate and a block diagram of the card Cisco ONS 15454 SDH Reference Manual, R40 2-17

26 Alarm Interface Controller International Card Chapter 2 Figure 2-12 AIC-I Faceplate and Block Diagram AIC-1 FAIL PWR Fail ACT A B Act ACC AIC-I UDC-A UDC-B INPUT/OUTPUT ACC Ring Express orderwire (DTMF) DCC-A DCC-B Local orderwire 12/16 x IN UDC-A (DTMF) Ring UDC-B DCC-A Ringer 4 x IN/OUT DCC-B Power Monitoring RING LOW Input Output LED x2 AIC-I FPGA EOW RING EEPROM SCL links 78828 261 AIC-I Card-Level Indicators The AIC-I card has eight card-level LED indicators, described in Table 2-8 Table 2-8 AIC-I Card-Level Indicators Card-Level LEDs Red FAIL LED Green ACT LED Description The red FAIL LED indicates that the card s processor is not ready This LED is lit during reset The FAIL LED flashes during the boot process Replace the card if the red FAIL LED persists The green ACT LED indicates that the AIC-I card is provisioned for operation Green/Red PWR A LED The PWR A LED is green when a supply voltage within the specified range has been sensed on supply input A It is red when the input voltage on supply input A is out of range 2-18 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 26 Alarm Interface Controller International Card Table 2-8 AIC-I Card-Level Indicators (continued) Card-Level LEDs Description Green/Red PWR B LED The PWR B LED is green when a supply voltage within the specified range has been sensed on supply input B It is red when the input voltage on supply input B is out of range Yellow INPUT LED The INPUT LED is yellow when there is an alarm condition on at least one of the alarm inputs Yellow OUTPUT LED The OUTPUT LED is yellow when there is an alarm condition on at least one of the alarm outputs Green RING LED The green RING LED on the local orderwire (LOW) side is flashing when a call is received on the LOW Green RING LED The green RING LED on the express orderwire (EOW) side is flashing when a call is received on the EOW 262 User-Defined Alarms The AIC-I card provides input/output alarm contact closures You can define up to sixteen external alarm inputs and four external alarm inputs/outputs (user configurable) The physical connections are made using the MIC-A/P The alarms are defined using CTC For instructions, refer to the Cisco ONS 15454 SDH Procedure Guide LEDs on the front panel of the AIC-I indicate the status of the alarm lines: one LED representing all the inputs and one LED representing all the outputs External alarms (input contacts) are typically used for external sensors such as open doors, temperature sensors, flood sensors, and other environmental conditions External controls (output contacts) are typically used to drive visual or audible devices such as bells and lights, but they can control other devices such as generators, heaters, and fans You can program each of the sixteen input alarm contacts separately Choices include alarm on closure or alarm on open, an alarm severity of any level (Critical, Major, Minor, Not Alarmed, Not Reported), Service affecting or non-service affecting alarm-service level, and a 63-character alarm description for CTC display in the alarm log You cannot assign the fan-tray abbreviation for the alarm; the abbreviation reflects the generic name of the input contacts The alarm condition remains raised until the external input stops driving the contact or you unprovision the alarm input The output contacts can be provisioned to close on a trigger or to close manually The trigger can be a local alarm severity threshold, a remote alarm severity, or a virtual wire, as follows: Local NE alarm severity: A hierarchy of not reported, not alarmed, minor, major, or critical alarm severities that you set to cause output closure For example, if the trigger is set to minor, a minor alarm or above is the trigger Remote NE alarm severity: Same as the local NE alarm severity but applies to remote alarms only Virtual wire entities: You can provision any environmental alarm input to raise a signal on any virtual wire on external outputs 1 through 4 when the alarm input is an event You can provision a signal on any virtual wire as a trigger for an external control output You can also program the output alarm contacts (external controls) separately In addition to provisionable triggers, you can manually force each external output contact to open or close Manual operation takes precedence over any provisioned triggers that might be present Cisco ONS 15454 SDH Reference Manual, R40 2-19

26 Alarm Interface Controller International Card Chapter 2 263 Orderwire Orderwire allows a craftsperson to plug a phone set into an ONS 15454 SDH and communicate with craftspeople working at other ONS 15454 SDHs or other facility equipment The orderwire is a pulse code modulation (PCM) encoded voice channel that uses E1 or E2 bytes in the multiplex section overhead and in the regenerator section overhead The AIC-I allows simultaneous use of both local (section overhead signal) and express (line overhead signal) orderwire channels on an SDH ring or particular optics facility Express orderwire also allows communication via regeneration sites when the regenerator is not a Cisco device You can provision orderwire functions with CTC similar to the current provisioning model for DCC/GCC channels In CTC, you provision the orderwire communications network during ring turn-up so that all NEs on the ring can reach one another Orderwire terminations (that is, the optics facilities that receive and process the orderwire channels) are provisionable Both express and local orderwire can be configured as on or off on a particular SDH facility The ONS 15454 SDH supports up to four orderwire channel terminations per shelf This allows linear, single ring, dual ring, and small hub-and-spoke configurations Keep in mind that orderwire is not protected in ring topologies such as multiplex section-shared protection ring (MS-SPRing) and subnetwork connection protection (SNCP) Caution Do not configure orderwire loops Orderwire loops cause feedback that disables the orderwire channel The ONS 15454 SDH implementation of both local and express orderwire is broadcast in nature The line acts as a party line Anyone who picks up the orderwire channel can communicate with all other participants on the connected orderwire subnetwork The local orderwire party line is separate from the express orderwire party line Up to four OC-N/STM-N facilities for each local and express orderwire are provisionable as orderwire paths The OC3 IR 4/STM1 SH 1310 card does not support the express orderwire (EOW) channel The AIC-I supports selective dual tone multifrequency (DTMF) dialing for telephony connectivity which causes specific or all ONS 15454 SDH AIC-Is on the orderwire subnetwork to ring The ringer/buzzer resides on the AIC-I There is also a ring LED that mimics the AIC-I ringer It flashes when a call is received on the orderwire subnetwork A party line call is initiated by pressing *0000 on the DTMF pad Individual dialing is initiated by pressing * and the individual four-digit number on the DTMF pad The orderwire ports are standard RJ-11 receptacles The pins on the orderwire ports correspond to the tip and ring orderwire assignments Orderwire pin assignments are described in Table 2-9 Figure 2-13 on page 2-21 shows the RJ-11 cable Table 2-9 Orderwire Pin Assignments RJ-11 Pin Number Description 1 Four-wire receive ring 2 Four-wire transmit tip 3 Two-wire ring 4 Two-wire tip 5 Four-wire transmit ring 6 Four-wire receive tip 2-20 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 26 Alarm Interface Controller International Card Figure 2-13 RJ-11 Cable Connector RJ-11 61077 Pin 1 Pin 6 264 User Data Channel The user data channel (UDC) features a dedicated data channel of 64 kbits/s (kbps) (F1 byte) between two nodes in an ONS 15454 SDH network Each AIC-I card provides two UDCs, UDC-A and UDC-B, through separate RJ-11 connectors on the front of the AIC-I Each UDC can be routed to an individual optical interface in the ONS 15454 SDH system For instructions, refer to the Cisco ONS 15454 SDH Procedure Guide The UDC ports are standard RJ-11 receptacles The UDC pin assignments are listed in Table 2-10 Figure 2-13 shows the RJ-11 cable connector Table 2-10 UDC Pin Assignments RJ-11 Pin Number Description 1 For future use 2 TXN 3 RXN 4 RXP 5 TXP 6 For future use 265 Data Communications Channel/Generic Communication Channel The data communications channel/generic communication channel (DCC/GCC) features a dedicated data channel of 576 kbits/s (kbps) (D4 to D12 bytes) between two nodes in an ONS 15454 SDH network Each AIC-I card provides two DCC/GCCs, DCC-A and DCC-B, through separate RJ-45 connectors on the front of the AIC-I Each DCC/GCC can be routed to an individual optical interface in the ONS 15454 SDH system For instructions, refer to the Cisco ONS 15454 SDH Procedure Guide DCC/GCC connection cannot be provisioned if DCC/GCC tunneling is configured on this span The DCC/GCC ports are standard RJ-45 receptacles The DCC/GCC pin assignments are described in Table 2-11 on page 2-22 Cisco ONS 15454 SDH Reference Manual, R40 2-21

26 Alarm Interface Controller International Card Chapter 2 Table 2-11 DCC/GCC Pin Assignments RJ-45 Pin Number Description 1 TCLKP 2 TCLKN 3 TXP 4 TXN 5 RCLKP 6 RCLKN 7 RXP 8 RXN 266 AIC-I Specifications The AIC-I card has the following specifications: Alarm inputs Number of inputs: 16 Opto-coupler isolated Label customer provisionable Severity customer provisionable Common 32-V output for all alarm-inputs Each input limited to 2 ma Termination via MIC-A/P Alarm outputs Number of outputs: 4 (user configurable as inputs) Switched by opto-mos (metal oxide semiconductor) Triggered by definable alarm condition Maximum allowed open circuit voltage: 60 VDC Maximum allowed closed circuit current: 100 ma Termination via MIC-A/P EOW/LOW ITU-T G711, ITU-T G712, Telcordia GR-253-CORE A-law, mu-law Due to the nature of mixed coding, in a mixed-mode configuration (A-law/mu-law) the orderwire is not ITU-T G712 compliant Orderwire party line DTMF signaling 2-22 Cisco ONS 15454 SDH Reference Manual, R40

Chapter 2 26 Alarm Interface Controller International Card UDC Bit rate: 64 kbits/s (kbps), codirectional ITU-T G703 Input/output impedance: 120 ohms Termination: RJ-11 connectors DCC/GCC Bit rate: 576 kbits/s (kbps) EIA/TIA-485/V11 Input/output impedance: 120 ohms Termination: RJ-45 connectors ACC connection for additional alarm interfaces For future use Environmental Operating temperature: 40 to +65 degrees Celsius ( 40 to +149 degrees Fahrenheit) Operating humidity: 5 to 95%, noncondensing Power consumption: 800 W, 017 A, 273 BTU/hr Dimensions Height: 3213 mm (12650 in) Width: 182 mm (0716 in) Depth: 2286 mm (9000 in) Card weight: 18 lb (082 kg) Compliance ONS 15454 SDH cards, when installed in a system, comply with these standards: Safety: UL 1950, CSA C222 No 950, EN 60950, IEC 60950 Cisco ONS 15454 SDH Reference Manual, R40 2-23

26 Alarm Interface Controller International Card Chapter 2 2-24 Cisco ONS 15454 SDH Reference Manual, R40