Refrigerants & Cooling in renovation buildings

Similar documents
Daikin s Policy. and Comprehensive Actions on the Environmental Impact of

Stakeholder Meeting Dublin, Ireland Update on the new F-Gas Rules Andrea Voigt, EPEE

Meeting the Challenges of the EU HFC Phase-Down

PREPARE FOR CHANGE LOW GWP ALTERNATIVES. November 17

FACT SHEET 9 Large Air-Conditioning (air-to-air)

New F-Gas Regulation (2014): Guidance for Food and Drink Manufacturers. REI Guide 4a. The 2014 EU F-Gas Regulation

Natural refrigerant trends in EU, Japan & North America

FACT SHEET 9 Large Air-Conditioning (air-to-air)

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

Overview of Alternatives and Climate Impact Scenarios Report of Decision XXV/5 Montreal Protocol

International New Technology and Refrigerant Symposium

FACT SHEET 6 Transport Refrigeration

Alternatives to HCFC/HFC refrigerants for high ambient temperatures

NATURAL REFRIGERANTS FOR HEAT PUMPS AND AIR-CONDITIONING SYSTEMS. Bernard Thonon Greth

Overview of New Refrigerants and Expected Market Trends

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Oct. Newly Developed Refrigerants for Refrigeration, meeting Global Warming Regulations. Hitomi ARIMOTO / Product R&D Department, Chemicals Division

The R-404A Challenge. Commercial Opteon Refrigerant Solutions - The New Industry Standard

Update on Next Generation Low GWP Refrigerants for Chillers Products. Steve Kujak Director, Next Generation Refrigerant Research

Current status of Japan s legislation on F-gases and RACHP using Low-GWP Refrigerants

Honeywell Refrigerant Update

Stay in business: STOP installing R-404A / R-507A! R-404A R-507A

Low GWP alternative refrigerants to R404A

Sustainable Refrigerant Solutions for HVAC-R. Laurent Abbas, Wissam Rached, Brett Van Horn

Flammability and the Low GWP Refrigerant Challenge

"ETI-Z, GART-ZE/ZEI" Centrifugal Chillers using Low-GWP Refrigerants for Full Capacity Range

Making equipment decisions

Alternatives in the AC & Chiller Sectors. Sukumar Devotta and Lambert Kuijpers OORG Refrigeration

SOLSTICE L40X (R-455A)

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011

Be sustainable while protecting your business

The natural solution for domestic refrigeration

Actions to Control Emission of HFCs in Japan

Overview of refrigerant alternatives in the air conditioning sector *

The Current Path of Refrigerants

New Refrigerants & Selecting Capital Equipment

Reducing Refrigerant Leakage

Transitioning to Alternatives and Challenges in Japan

ETI-Z Series Centrifugal Chiller Applied Low GWP Refrigerant to Contribute to the Prevention of Global Warming

2017 Climate & Refrigerants Outlook. Stephen Yurek President & CEO

DEMONSTRATION OF ADVANCED INTEGRATED HVAC&R SYSTEMS IN A LOBLAWS SUPERMARKET IN CANADA

Possibilities of the RAC sector transformation a technical perspective

DuPont Refrigerants. John McCormack Business Manager DuPont Chemicals and Fluoroproducts. R22 market and the ISCEON retrofit options

Effectively Managing the Transition to Lower GWP Refrigerants

Japanese market and issue of Heat Pump Kenji Matsuda

GUIDE TO THE F-GAS REGULATION (EC 517/2014)

Industry co-operation on Natural Refrigerant technology development Kenji Matsuda

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

The impact of legislation and trends for the industry

natural refrigerants - global trends & developments

Alternative Refrigerants Part 1 Future and Current Options. Overview

Guidance for Stationary Refrigeration & Air-Conditioning

Large AC units using a variety of low-gwp options

Development of centrifugal chiller and heat pump using low GWP refrigerant

CO 2 transcritical FTE System Full Transcritical Efficiency

March 2014 AHRI Presents Research Findings at Low-GWP AREP Conference

ADVANCED TRAINING INSTITUTE, HYDERABAD PR04/F01

Refrigerant & Energy Regulations Update

EC Regulation No 842/2006 on certain fluorinated greenhouse gases

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

Cooling Only & Heat Pump

Update on Opteon Refrigerants

The 10 th Three Associations Meeting JRAIA. The Japan Refrigeration and Air Conditioning Industry Association. August 31, 2016.

Flammability and New Refrigerant Options

R-404A Alternative with Low Compressor Discharge Temperature

Evaluation of HCFC Alternative Refrigerants

Exhibition Hall 1. Fachprogramm. Technical Programme

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

Magnetic Refrigeration. Study Case

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Policies and Measures for HCFCs in Japan

WP2 European Product Analysis, Task 2.1 Determining energy efficiency criteria, D 2.1 Periodic Criteria Papers (first set)

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

HFCs or the Old Refrigerants - what is the best Choice?

PACIFIC HVAC Air conditioner. Authorized Daikin Split systems & VRV contractor. Tel:

HFO-1234yf Performance in a Beverage Cooler

Mechanical Systems Mechanical Systems

ON SUBSTANCES THAT DEPLETE

New Case studies on Low GWP alternative refrigerants for HFCs. ABHIJEET KUDVA

AIRAH Victoria Refrigerants Update

Transitioning to Alternatives and Challenges in Japan

recooler HP EQKR HEAT PUMP

CO 2. ECO Water Heaters. Energy efficient and environmentally friendly water and space heating. SANYO Air Conditioners. The natural choice.

The Changing State of Refrigerants. Gary Parker Refrigerants Product Manager

Environmentally friendly refrigeration systems for industrial use

Hall 7A. Chillventa Specialist Forums 2018 Chillventa Fachforen NürnbergMesse, Arbeitstitel, Datum 1

July 2012 was a significant date for the HVAC and Refrigeration industry as it saw the introduction of the Carbon Tax and the HFC Levy.

Legislation & Standards

Thermodynamics I. Refrigeration and Heat Pump Cycles

DuPont ISCEON 9 Series Refrigerants

Member Briefing JAPAN

Information Guide Maintenance and Refrigerant Regulations. Issue 35

Effectively Managing the Transition to Lower GWP Refrigerants

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Challenges and responses in refrigerant conversion

Natural Refrigerants.

EVALUATION OF ALTERNATIVERS TO R404 THE MOST COMMON REFRIGERANT IN SWEDISH GROCERY STORES

Use of hydrocarbon refrigerants in commercial refrigeration and air conditioning equipment

Embraco Position Paper: Light Commercial Refrigeration

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Transcription:

Refrigerants & Cooling in renovation buildings 01 Basics Refrigeration circuit. 1

Refrigeration Basics LP HP Mollier Diagram A-C Evaporation B-C Superheat C-D Compression D-E Desuperheat D-G Condensation F-G Subcooling Multi HP - Cooling SV SV SV SV 2

Multi HP - Heating SV SV SV SV 02 Refrigeration 3

Question! From all worldwide greenhouse gas emissions, howmuch % is due toemissionsof HFCs? A. 0,2 % B. 2% C. 20% Question! From all worldwide greenhouse gas emissions, how much % is due to ENERGY? A. 15 % B. 25% C. 35% 4

Why Daikin takes actions on refrigerants? The current impact of HFC emissions on global warming is small but increasing. The main HFC use sectors are refrigeration (40~58%) and air conditioning (21 ~40%) The main HFC consuming regions are China, USA, Middle East, Asia Global greenhousegas emissions(gtco 2 eq) F gases (HFC+PFC+SF6) = 2% 70 60 50 40 30 20 10 0 2010 2050 Estimated HFC emissions (business as usual) : 4 ~ 5.3 GTCO 2 eq Sources : IPCC, 2014: Climate Change 2014: Synthesis Report. Contribution of Working Groups I, II and III to the Fifth Assessment Report of the Intergovernmental Panel on Climate Change [Core Writing Team, R.K. Pachauri and L.A. Meyer (eds.)]. IPCC, Geneva, Switzerland Future and climate forcings from scenarios of global and regional hydrofluorocarbon (HFC) emissions, Guus J.M. Velders et al., October 2015 (*) 60 GtCO2eq in 2050 = SSP3 scenario values of different scenarios varybetween 30 to 100 GtCO2eq What are F gases? HFCs, PFCs and SF6 are F gases = fluorinated greenhouse gases. They do not deplete the ozone layer, but account for 2% of the overall EU greenhouse gas emissions. Nearly 80% of F gas emissions are due to the emissions of HFCs used as refrigerants in air conditioners, heat pumps and refrigeration products 5

EU targets to reduce greenhouse gas emissions Targets will be mostly achieved by the change of electricity generation & by reducing energy consumption. However also other sectors need to contribute. EU 20-20-20 policy 20% reduction by 2020 NEW EU agreement for 2030 40% reduction by 2030 EU low carbon roadmap2050 80% reduction by 2050 Source: EU low carbon roadmap 2050 F gases such as HFCs used in ourair conditioners and heat pumps belong tothe group of non CO2 other sectors The HFC phase-down schedule Main principles: 1. Quota are in CO2 equivalent (kg x GWP value) 2. Quota are imposed from 2015 onwards on the bulk HFC producers or importersthat place HFCs on the EU market for the first time push on the supplierswill trigger the users togo foralternative solutions Year Reduction by 2009-2012 Baseline 2015 100% (Freeze) 2016-17 93% 2018-20 63% 2021-23 45% 2024-26 31% 2027-29 24% 2030 21% 100% 80% 60% 40% 20% 0% 93% 63% 45% 31% 24% 21% 2015 2016 2018 2021 2024 2027 2030 6

Towards a sustainable refrigerant & equipment lifecycle Role as refrigerant manufacturer We will continue to research refrigerants that meet diverse needs, aiming to achieve a more sustainable HVACR sector Destruction of refrigerants Develop and produce refrigerants Recycle refrigerants Develop & produce equipment Role as equipment manufacturer We will continue to improve energy efficiency of equipment and select optimal refrigerants for each application Install equipment Recover equipment & Together with other stakeholders refrigerant We continue to work with related stakeholders towards a sustainable HVACR industry, including use, maintenance and recovery of equipment and refrigerants Maintenance Use equipment Daikin refrigerant direction key considerations At Daikin we assess 4 basic factors when making a refrigerant choice fora product application : Safety Energy efficiency Cost- Effectiveness Environmental impact 7

Drivers of HFC Demand: the 8 Main Market sectors Small/medium/large DX Pumped/flooded Process Chillers Large A/C Transport chillersrefrig Small A/C chillers 1.3% Domestic heat pumps Commercial heat pumps Baseline Split (of 205 MT CO2) Industrial Refrig 10.0% Chillers & Hydro-HP 8.6% Domestic Refrig 0.2% Commercial Refrig 28.7% Small hermetic Condensing units Large pack systems Small hermetic Small/medium/large splits VRF/Packaged Stationary AC & HP 23.0% Non RAC 13.3% Mobile AC 14.8% Foams Aerosols (technical) Aerosols (medical) Fire protection Solvents Cars and small vans Other MAC (buses, trains etc.) Remember: A phase down is not a phase out! A phase down is based on CO 2 eq = GWP x kg GWP x kg It can be achieved by a combination of : lower GWP : Changing refrigerant type less kg : Reducing refrigerant charge amount Minimizing leakage Increasing Recovery & reuse The future will be based on a wide diversity of refrigerants (HFC, HFO, blends, natural refrigerants) there is no one-size-fits-all solution 8

New F gas regulation : additional GWP limits for air conditioners & heat pumps GWP limitations For portable AC : GWP must be<150 from 2020 For SINGLE split air conditionerswith a charge BELOW 3 kg: GWP must be<750 from 2025 R410A : NotOK R290 : OK R410A : NotOK R32 : OK New F gas regulation : additional GWP limits on refrigeration products Service ban on existing refrigeration systems with charge of > 40TCO2eq : GWP must be <2500 (new gas 2020, recycled/reclaimed gas 2030) In all new stationary refrigeration GWP must be <2500 from 2020 More strict GWP limits on : Residential & commercial fridges & freezers (GWP<150) (2020/2022) Multipack supermarket systems >40kW (GWP<150 or cascade GWP<1500+GWP<150) (2022) 9

4 Types of Compressors Used Rotary Type/Swing Compressor Scroll Type Compressor Up to 7 kw Screw Type Compressor Positive Displacement Up to 70 kw Centrifugal Type Compressor Positive Displacement Up to 1000 kw Dynamic Compression From 500 kw 10

Daikin refrigerant direction by product segment Including Zanotti, J&E Hall Today Status Air conditioners& heat pumps Chillers& Air side equipment Refrigeration R410A R32 R410A, R134a, Ammonia R404A, R410A,R134a, R448a, R449a, CO2, Ammonia, HC : R290, R600a R32 product portfolio expanding since 2012 Under investigation: R32, HFO, blends Underinvestigation: R407H, R32, HFO Marine containers R134a Under investigation: R32, HFO, R513 AC & Refrigeration for vessels R404A R407C Truck& Trailer refrigeration R404A, R452A R407C completed Under investigation: R407H& others Lower GWP under investigation 21 some markets have ultra-low GWP options available, e.g.: car air-conditioning HFO-1234yf GWP = 3 domestic refrigerators HC-600a GWP = 4 large retail refrigeration R-744 (CO 2 ) GWP = 1 water chillers for large AC HFO-1234ze GWP = 7 DX air-conditioning market more difficult no ultra-low GWP option currently available HFC-32 is a good moderate GWP option for smaller systems (GWP = 675) approx. 75% reduction in tonnes CO 2 (taking into account reduced GWP and charge) but limitations on maximum charge due to A2L lower flammability rating R-410A still a good option for larger DX systems e.g. VRF 11

2030 phase-down target will be met with a mix of many refrigerants ultra-low GWP refrigerants in many markets car AC, commercial refrigeration, AC water chillers HFC-32 and other moderate GWP refrigerants in some markets including smaller DX AC R-410A in larger DX AC systems that require a non-flammable refrigerant e.g. VRF systems Daikin comprehensive approach towards an HFC phase down Conversion to lower GWP refrigerant Prevention of leakage Reducing amount of refrigerant charge Refrigerant recovery & reuse 12

There is no one-size-fits all refrigerant Each manufacturer needs to make choices depending on the application and the needs of the market & taking into account energy efficiency, safety, affordability, local legislations & standards. Daikin is developing R32 split air conditioners from residential to commercial range because R32 is suitable for these applications R32 03 Coolingin Renovation Buidlings 13

W. CHILLER vs VRV MAIN SOLUTIONS AVAILABLE: HIGHER EFFICIENCY Direct expansion is well known to be more efficient than traditional chillers for small and medium capacities (>300kW) 14

SMALL PIPES Refrigerant pipe are quite smaller compared to air ducts or water pipes, because DX takes advantages of latent heat. LESS FOOTPRINT AND WEIGHT VRV systems are less heavy so there is no need of structure reinforcement VRV units are even more compact and their installation in more flexible 15

CHEAP SOLUTION Small footprint gives the opportunity to increase the business Easy installation has a low impact on construction costs High efficiency has a positive impact on running costs VRV IV TECHNOLOGY A step forward towards more efficiency and compactness... December 2014 VRT INVERTER COMPRESSOR DC FAN MOTOR HEAT EXCHANGER 16

VRT control for energy saving in partial load condition Conventional VRF controls capacity by compressor inverter control and On/Off control of Indoor unit. VRT can manage the capacity by control of Te and Tc in order to achieve high seasonal efficiency. Previous Daikin VRV III or competitors unit VRV4 controls capacity by compressor inverter control and On/Off control of Indoor unit manage the capacity by control of Te&Tc, and inverter control Refrigerant T Capacity & Load Efficiency Fixed Te 20 20 25 30 25 30 100%capacity operation for I/U 35 System capacity 35 Cooling requirement Design point On/Off operation due to over capacity Refrigerant T Capacity & Load Efficiency Fixed Te 20 20 Efficiency UP Variable Te 25 30 25 30 35 System capacity 35 Cooling requirement Design point Adjust proper capacity by Te control. (On/Off operation can be avoided) Seasonal efficiency ESEER +28% 20 25 30 35 Replacement VRV Outdoor temperature Example: cooling 20 25 30 35 Outdoor temperature Example: cooling VRV SYSTEMS. Plug and Play Total Solution More efficient, especially in comparison with air cooled chiller Payback period of 3-4 years Easy and fast selection, design and installation Less noisy outdoor units and small footprint Small pipes diameters No need for water treatment Plug and play total HVAC solution Suitable solution for any small and medium commercial application Addressing big commercial application by using water cooled VRV 17

Thank you 18