VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw

Similar documents
VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw

VIESMANN. Datasheet VITOMAX 200-WS. Hot water boiler for permissible flow temperatures up to 110 C 1.75 to MW

VIESMANN. VITOMAX 200-WS Rated heating output 1.75 to MW. Datasheet. VITOMAX 200-WS Type M250

VIESMANN. VITOMAX 200-LW Low pressure hot water boiler for permissible flow temperatures up to 120 C Rated heating output 8.0 to 20.0 MW.

VIESMANN VITOROND 100. Datasheet Part numbers and prices: see pricelist VITOROND 100. Cast iron low temperature oil and gas fired boiler.

VIESMANN VITOLADENS 300-T Oil Unit condensing boiler 35.4 to 53.7 kw

VIESMANN VITOLADENS 300-C Oil condensing boiler 12.9 to 28.9 kw

VIESMANN VITOLADENS 300-C Oil condensing boilers 12.9 to 28.9 kw

VIESMANN. Installation instructions VITOCROSSAL 200. for contractors. Vitocrossal 200 Type CM2 Gas fired condensing boiler with MatriX radiant burner

Floorstanding Gas Condensing Boilers VITOCROSSAL 100

VIESMANN. Installation instructions VITOMAX 200-HW. for contractors

VIESMANN. Installation instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CM3 Gas condensing boiler with MatriX radiant burner

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOCELL 300-V. Vertical DHW cylinder. 130to500litrecapacity. Vitotec folder, register 17

VIESMANN VITOCELL 300-V Vertical DHW cylinder 130 to 500 l capacity

VIESMANN VITOVENT 300-F Mechanical ventilation system with heat recovery

VIESMANN. Gas condensing boilers 87 to 1400 kw. Technical guide. VITOCROSSAL 200 Type CM2. VITOCROSSAL 300 Type CM3. VITOCROSSAL 300 Type CT3U

VIESMANN. Service instructions VITOLADENS 300-T. for contractors. Vitoladens 300-T Type VW3B Inox-Radial heat exchanger for oil fired condensing Unit

VIESMANN. Service instructions. MatriX radiant burner. for contractors

VIESMANN. Datasheet For part no. and prices: see pricelist VITOLIGNO 300-P. Pellet boiler 4to48kW. Vitotec folder, register 12. File in: Type VL3B

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation instructions VITODENS 200-W. for contractors

VIESMANN. Operating instructions VITODENS 100-W. for the system user

VIESMANN. Service instructions VITOCELL 300-B VITOCELL 300-V. for contractors

Technical Data Manual Model Nos. and pricing : See Price List

Technical Data Manual Model Nos. and pricing : See Price List

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Operating instructions VITODENS 111-W. for the system user

VIESMANN. Service instructions VITOCROSSAL 300. for contractors. Vitocrossal 300 Type CR3 and CR37, 787 and 978 kw Gas condensing boiler

WOLF GAS CONDENSING BOILERS COMFORTLINE

VIESMANN. Operating instructions VITODENS VITOPEND. for the system user. Heating system with Vitotronic 100 control unit for constant temperature mode

VIESMANN. Installation instructions. Extension AM1. Safety instructions. for contractors. Part no

Technical documentation. ComfortLine gas condensing boilers CGB-2(K) CGW-2 CGS-2 CSZ-2 NEW

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

VIESMANN. Service instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

VIESMANN. Installation and service instructions VITOTROL 200 RF. for contractors. Vitotrol 200 RF. Wireless remote control for one heating circuit

VIESMANN. Operating instructions DIGITAL TIME SWITCH. for the system user. Digital time switch for the Vitodens 100-W, type WB1B

VIESMANN. Installation and service instructions VITOTROL 300A. for contractors. Vitotrol 300A. Remote control, part no

VIESMANN. Installation and service instructions. Solar-Divicon SR. Safety instructions. Application. for contractors. Part no and

VIESMANN. Operating instructions VITODENS 050-W. for the system user. With constant temperature or weather-compensated control unit

VIESMANN. Installation instructions VITOCELL 300-V/W. for contractors. Vitocell 300-V/W Type EVIA-A

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

Oil/gas boilers and low pressure hot water boilers up to 22 MW

and Installation Instructions The installation instructions for the Unit pressure jet oil burner is included in the pressure jet oil burner pack.

VIESMANN. Installation instructions VITORONDENS 200-T. for contractors. Vitorondens 200-T Type BR2A, 20.2 to 53.7 kw Oil Unit condensing boiler

for contractors Vitoplex 200 Type SX2A For applicability, see the last page Please keep safe.

VITOPLEX. Low temperature oil and gas fired boilers Rated output Vitoplex 100: 575 to 1750 kw Vitoplex 200: 90 to 560 kw Vitoplex 300: 80 to 1750 kw

The competent brand for energy saving systems NEW. Gas-combi boiler CGG-1K-24/28

Solar-Divicon and solar pump assembly. Please follow these safety instructions closely to prevent accidents and material losses.

Technical Data Manual Model Nos. and pricing : See Price List

WOLF WALL MOUNTED GAS CONDENSING BOILERS COMFORTLINE

VIESMANN. Installation instructions. Mixer extension kit. for contractors. Mixer extension kit. For one heating circuit with mixer

Technical Data Manual Model Nos. and pricing: see Price List

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

Installation and maintenance instructions

Clyde Alkon 90. Floor standing condensing boilers. Natural Gas. 90 kw. LP Gas. 90 kw

VIESMANN. Installation and service instructions VITOCELL 340-M/360-M. for contractors. Vitocell 340-M/360-M Type SVKA Type SVSA

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

Installation and maintenance instructions

Vitocrossal 300, CU3A - Introduction

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

VIESMANN. Service instructions VITODENS 200-W. for contractors

1 VICTRIX ZEUS Superior kw I features

Remeha. Fuel oil/gas boilers P 520. Installation and Service Manual A

Pellet Boiler VITOLIGNO 300-P. Test winner Good (2.1) Pellet boiler VITOLIGNO 300-P. In the test: 10 systems 1 winner

Installation instructions PYROMAT ECO. for contractors PYROMAT ECO GB 8/2012 Dispose after installation.

Light oil - kerosene burner

ECONOFLAME R6000 GAS FIRED CONDENSING HOT WATER HEATER SUPPLEMENT

ENERGY TOP. Condensing boiler solutions

Quinta Pro Range. The New Remeha. Condensing Boilers REMEHA QUINTA PRO RANGE. High efficiency wall hung condensing boiler with ultra low NOx emission

VIESMANN. Operating and service instructions VITOMAX 200-HW. for contractors

Logamax plus GB172/GB172T. Heat is our element. Technical Guide Issue 2011/06. Fügen Sie auf der Vorgabeseite das zur Produktgruppe passende Bild ein.

Hoval TopGas (12, 16, 22)

GAS 610 ECO PRO. The new Remeha. Condensing Boiler Range REMEHA GAS 310/610 ECO PRO

CAST IRON PREMIX HIGH EFFICIENCY GAS FIRED BOILER kw BRILEY DESIGN MANUAL

Sirius FS. Working towards a cleaner future

Wall-hung boilers. Spare parts catalogue. ecotec plus

Ultramax R600. High output, floor standing gas fired condensing boilers with outputs from 150kW to 571kW

Stokvis R600 LMS IP Water Heater Gas-Fired Floor Standing Condensing

TermEfekt USER S MANUAL AIR HEATER. Model PGA 14

RIELLO 40 GS/M SERIES

Technical Data Manual for use by heating contractor VITOROND 200

Gas Instantaneous Water Heater

Technical information. Remeha P200. Pressurized boiler. Heat output: kw

VICTRIX 90 VICTRIX 115 Wall-hung condensing boilers for high power

Max-3 plus. Output range 420 to 2700 kw TopTronic E control. Steel Shell Boiler. Responsibility for energy and environment

VIESMANN. Installation and service instructions VITODENS 343-F. for contractors

WELCOME TO REMEHA, THE EXPERT CHOICE INTRODUCING THE REMEHA GAS 310/610 ECO PRO RANGE FEATURES AND BENEFITS

Sirius WH. Working towards a cleaner future

Technical Data Manual Model Nos. and pricing: see Price List VITOCROSSAL 300

VICTRIX Superior kw Export VICTRIX Superior kw X Export

Installation and service instructions for contractors Logano plus SB625. Burner shroud not available in UK and Ireland

R e m e h a P Technical Information. Remeha P 300. Pressurized boiler. Heat output: kw

VIESMANN. Installation and service instructions VITODENS 111-W. for contractors

Technical guide VITOMAX 200 HS. Notes on design and operation. Vitotec technical guide folder, register 1. File in:

Domestic Product Guide

Mikrotherm. Manual Radiator Valves With presetting

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

CBX 24, 32 & 38 SBX 30

Transcription:

VIESMANN VITOCROSSAL 300 Gas condensing boiler 187 to 635 kw Datasheet Part no. and prices: see pricelist VITOCROSSAL 300 Type CT3B Gas condensing boiler for natural gas E, LL and LPG With modulating MatriX radiant burner up to 314 kw (natural gas E and LL) 5614 838 GB 5/2012

Benefits at a glance Standard seasonal efficiency [to DIN]: up to 98 % (H s ) [gross cv] / 109 % (H i ) [net cv]. The stainless steel, corrosion-resistant Inox-Crossal heat exchanger ensures high operational reliability and a long service life. Inox-Crossal heat exchanger for highly effective heat transfer and condensation rate. Self-cleaning effect through smooth stainless steel surface. Clean combustion through low combustion chamber loading and straight-through design. With MatriX radiant burner up to 314 kw for particularly economical and environmentally responsible operation, with a modulation range from 30 to 100 %. Alternatively with ELCO or Weishaupt pressure-jet gas burner. Two return connectors for hydraulic connection optimised for condensing technology. Vitotronic control unit that is easy to operate with plain text and graphic display. A Vitotronic control unit B Stainless steel Inox-Crossal heat exchanger C Water-cooled stainless steel combustion chamber D Highly effective thermal insulation E Modulating MatriX radiant burner 5614 838 GB 2 VIESMANN VITOCROSSAL 300

Boiler specification Specification Rated heating output T V /T R = 40/30 C kw 187 248 314 408 508 635 T V /T R = 80/60 C kw 170 225 285 370 460 575 Rated heat input kw 177 234.5 297 385.5 479 599 Product ID CE-0085AQ0257 Permiss. operating temperature C 100 100 100 100 100 100 Permiss. flow temperature C 110 110 110 110 110 110 (= safety temperature) Max. permiss. operating pressure bar 4 4 4 5.5 5.5 5.5 Min. permiss. operating pressure *1 bar 0.5 0.5 0.5 0.5 0.5 0.5 Pressure drop on hot gas side Pa 100 140 160 200 220 270 mbar 1.0 1.4 1.6 2.0 2.2 2.7 Boiler body dimensions Length c +d (excl. boiler door) mm 1650 1728 1783 1823 1901 2057 Width t mm 684 684 684 800 800 800 Height n (incl. connectors) mm 1745 1794 1794 2012 2012 2012 Overall dimensions Total length b mm 1636 1714 1795 1871 1949 2105 Total length a (incl. MatriX burner) mm 1889 1967 2045 Total width q mm 988 988 988 1104 1104 1104 Total height p mm 1959 2009 2032 2290 2290 2290 Width u (incl. thermal insulation) mm 821 821 821 937 937 937 Foundations Length mm 1350 1450 1500 1600 1650 1800 Width mm 800 800 800 900 900 900 Height mm 100 100 100 100 100 100 Weight Boiler body kg 445 490 510 740 780 890 Removable combustion chamber without kg 96 96 96 124 124 124 boiler door Total weight kg 608 660 683 937 982 1098 Boiler with thermal insulation and boiler control unit Capacity boiler water l 240 265 300 460 500 540 Boiler connections Boiler flow PN 6 DN 65 65 80 100 100 100 Boiler return 1 *2 PN 6 DN 65 65 80 100 100 100 Boiler return 2 *2 PN 6 DN 50 50 50 80 80 80 Safety connection (safety valve) R 1¼ 1¼ 1¼ 1¼ 1½ 1½ Drain R 1 1 1 1 1 1 Condensate drain R ½ ½ ½ ½ ½ ½ Flue gas parameters *3 Temperature (at 30 C return temperature) at rated heating output C 45 45 45 45 45 45 at partial load C 40 40 40 40 40 40 Temperature (at 60 C return temperature) C 75 75 75 75 75 75 Mass flow rate (for natural gas) at rated heating output kg/h 269 357 452 586 727 909 at partial load kg/h 81 107 136 176 218 272 Available draught Pa 70 70 70 70 70 70 at the flue outlet mbar 0.7 0.7 0.7 0.7 0.7 0.7 Flue gas connection 7 mm 200 200 200 250 250 250 Standard seasonal efficiency [to DIN] at heating system temp. 40/30 C % up to 98 (H s ) [gross cv] /109 (H i ) [net cv] at heating system temp. 75/60 C % up to 95 (H s ) [gross cv] /106 (H i ) [net cv] Standby loss q B,70 % 0.40 0.30 0.30 0.30 0.28 0.25 5614 838 GB *1 For safe operation, a minimum operating pressure of 0.5 bar is essential. For this, a minimum pressure switch can be used. *2 When connecting 2 heating circuits, connect the heating circuit with the lowest temperature level to boiler return 1. *3 Values for sizing the flue system to EN 13384, based on 10 % CO 2 for natural gas Flue gas temperatures captured as gross values at 20 C combustion air temperature. The details for partial load refer to 30 % of the rated heating output. Calculate the flue gas mass flow rate accordingly when the partial load differs from that stated above (subject to burner operating mode). VITOCROSSAL 300 VIESMANN 3

i l Boiler specification (cont.) Note The available draught is achieved at the flue outlet with the MatriX radiant burner from our product range (up to 314 kw), with pressure-jet gas burners (from Weishaupt or ELCO) and many other pressure-jet gas burners. For alternative draughts, refer to the relevant burner manufacturer. If using the Vitocrossal 300 with moisture-resistant chimneys, the draught must be no more than 0 Pa. v e a b c w d q KRG SCH KV SA RG KTS f KTÜ 140 A m n o p DB KR2 KR1 E g k AGA h x z KOA j y r t u s A To safeguard perfect function, maintain the required minimum blast tube length. AGA Flue outlet DB R ½ female connection for pressure limiter E Drain KOA Condensate drain KR 1 Boiler return 1 KR 2 Boiler return 2 KTS KTÜ KRG KV RG SA SCH Boiler water temperature sensor Boiler door with burner connection flange Vitotronic control unit Boiler flow R ¾ female connection for additional control equipment Safety connection (safety valve) Inspection port (boiler with 187 to 314 kw: 90 offset) Dimensions Rated heating output kw 187 248 314 408 508 635 a mm 1889 1967 2045 b mm 1636 1714 1795 1871 1949 2105 c mm 1509 1587 1665 1743 1821 1977 d mm 141 141 118 80 80 80 e mm 715 715 715 751 751 751 f mm 1299 1349 1349 1500 1500 1500 g mm 194 194 194 190 190 190 h (length of the base rails) mm 1257 1335 1413 1488 1566 1722 i mm 298 298 298 325 325 325 j mm 165 165 165 168 168 168 k mm 518 518 523 577 577 577 l mm 802 852 852 921 921 921 m mm 1704 1755 1755 1962 1962 1962 n (transport dimension) mm 1745 1794 1794 2012 2012 2012 o mm 1879 1928 1935 2185 2185 2185 p mm 1959 2009 2032 2290 2290 2290 q mm 988 988 988 1104 1104 1104 r mm 177 177 177 200 200 200 s mm 227 227 221 221 241 241 t (transport dimension) mm 684 684 684 800 800 800 u mm 821 821 821 937 937 937 v mm 257 257 257 284 284 284 w mm 12 12 12 25 25 25 x mm 1423 1501 1579 1654 1732 1888 y mm 82 82 82 85 85 85 z (transport dimension) mm 1600 1678 1756 1850 1928 2084 4 VIESMANN VITOCROSSAL 300 5614 838 GB

Boiler specification (cont.) The boiler door can be removed where access to the boiler room is difficult. If this is not sufficient, the boiler front panel can be delivered separately (please state when ordering). Siting Minimum clearances A B 200 b To enable convenient installation and maintenance, observe the stated clearance dimensions; maintain the minimum clearances where space is tight (dimensions in brackets). In the delivered condition, the boiler door opens to the right. You can reposition the hinge pins so that the door opens to the left. 500 (400) 500 (400) 500 (50) a A Boiler B Burner Rated heating output kw 187 248 314 408 508 635 a mm 930 1000 1100 1500 1500 1500 b Installed burner length Siting Avoid air contamination by halogenated hydrocarbons (e.g. as contained in sprays, paints, solvents and cleaning agents) Avoid very dusty conditions Avoid high levels of humidity Free from frost and well ventilated Otherwise, the system may suffer faults and damage. In rooms where air contamination through halogenated hydrocarbons may occur, install the boiler only if adequate measures can be taken to provide a supply of uncontaminated combustion air. 5614 838 GB VITOCROSSAL 300 VIESMANN 5

Boiler specification (cont.) Pressure drop on the heating water side 100 80 70 60 50 40 30 20 314 kw 187-248 kw 408-635 kw The Vitocrossal 300 is only suitable for fully pumped hot water heating systems. Pressure drop in mbar 10 8 7 6 5 4 3 2 1 2 3 4 5 6 7 8 10 20 30 40 50 60 Flow rate in m³/h Burner installation (MatriX radiant burner, see page 7) Ø c Ø b Ø a Ø d 140 The hole circle of burner fixing holes and the blast tube aperture match the dimensions of many well known burner makes. If the dimensions vary from the standard supplied, first drill the burner fixing holes into the burner plate and then cut out the blast tube aperture, before mounting the burner plate on the boiler door. Burner plates may be factory-fitted on request (chargeable option). For this, please state the burner make and type when ordering. The blast tube must protrude through the thermal insulation on the boiler door. A Sight glass for 408 to 635 kw with 90 offset (central vertical) Rated heating output kw 187 248 314 408 508 635 a Ø mm 240 240 240 290 290 290 b Ø mm 270 270 270 330 330 330 c Thread M 10 M 10 M 10 M 12 M 12 M 12 d Ø mm 123 123 123 196 196 196 5614 838 GB 6 VIESMANN VITOCROSSAL 300

Specification MatriX radiant burner Specification for use in conjunction with a Vitocrossal 300 (type CT3B) Rated boiler heating output (at T V /T R 40/30 C) kw 187 248 314 Burner heating output, lower/upper *4 kw 43/177 77/234 98/296 Burner type VM III-4 VM III-5 VM III-6 Product ID CE-0085 BL 0403 Voltage V 230 230 230 Frequency Hz 50 50 50 Power consumption at upper heating output W 225 335 385 at lower heating output W 35 40 55 Version Modulating Dimensions Length c mm 290 290 290 Total length d mm 585 585 585 Width a mm 540 540 540 Height b mm 576 576 576 Weight kg 43.5 45 47 Burner with combination valve and burner hood Gas supply pressure mbar 20 20 20 Gas connection R 1 1¼ 1¼ Connection values relative to the max. load with Natural gas E m 3 /h 4.5 18.7 8.2 24.8 10.3 31.3 Natural gas LL m 3 /h 5.3 21.8 9.5 28.8 12.0 36.4 NO x category (to EN 676) 3 3 3 a N O P R A B H b G K C D F E L M d c A Boiler door B Display and programming unit C Gas train D Gas supply pipe E Rotary damper with servomotor F Venturi mixing pipe G Fan H Burner gauze assembly K Ignition electrode L Ionisation electrode M Thermal insulation block N Ignition unit O Air pressure switch P Suppressor choke box R Burner control unit Delivered condition 5614 838 GB Boiler body with fitted cleaning cover, fitted mating flanges with gaskets at all connectors, fitted protective crate and flue gas collector. *4 Corresponds to the rated heat input of the boiler. For delivery of a MatriX radiant burner (up to 314 kw) the boiler door is fitted to the MatriX radiant burner; from 408 kw the boiler door is fitted to the boiler body. VITOCROSSAL 300 VIESMANN 7

Delivered condition (cont.) Where access to the boiler room is difficult, the Vitocrossal 300 may also be delivered in sections. The front panel of the combustion chamber can be removed on site, taken into the installation room separately and refitted. 1 or 2 boxes with thermal insulation 1 box with MatriX radiant burner and burner hood (up to 314 kw) 1 box with boiler control unit and 1 bag with technical documentation 1 connection line on the water side secured to the boiler plinth (from 408 kw) 1 burner plate pack (only for delivery without MatriX radiant burner) Suitable pressure-jet gas burners (from 187 kw) are available from Weishaupt or ELCO and should be ordered separately (see pricelist). Delivery by the burner manufacturer. The use of burners from other manufacturers is possible. Control unit versions For single boiler systems: Without Vitocontrol control panel Vitotronic 100 (type GC1B) For operation with a constant boiler water temperature or for weather-compensated operation in conjunction with a control panel (see below) or an external control unit. Vitotronic 200 (type GW1B) For modulating boiler water temperature without mixer control Vitotronic 300 (type GW2B) For modulating boiler water temperature with mixer control, for up to 2 heating circuits with mixer With Vitocontrol control panel Vitotronic 100 (type GC1B) and Vitocontrol control panel with Vitotronic 300-K (type MW1B) for weather-compensated operation and mixer control for up to 2 heating circuits with mixer and additional Vitotronic 200-H, type HK1B or HK3B for 1 or up to 3 heating circuits with mixer or Control panel with external control unit (on site) Without Vitocontrol control panel Vitotronic 100 (type GC1B) and LON module in conjunction with Vitotronic 300-K (type MW1B) For modulating boiler water temperature (one boiler is supplied with the standard control equipment for a multi boiler system) and Vitotronic 100 (type GC1B) and LON module for modulating boiler water temperature for each additional boiler in a multi boiler system With Vitocontrol control panel Vitotronic 100 (type GC1B) and LON module For modulating boiler water temperature for each boiler in a multi boiler system and Vitocontrol control panel with Vitotronic 300-K (type MW1B) for multi boiler systems, weather-compensated operation and mixer control for up to 2 heating circuits with mixer and additional Vitotronic 200-H, type HK1B or HK3B for 1 or up to 3 heating circuits with mixer or Control panel with external control unit (on site) For multi boiler systems: (up to 4 boilers) Boiler accessories See pricelist and "Boiler accessories" datasheet. Operating conditions Operating conditions with Vitotronic boiler control units For water quality requirements, see the technical guide "Standard values for water quality" Requirements 1. Heating water flow rate None 2. Boiler return temperature (minimum value) None 3. Lower boiler water temperature None 4. Two-stage burner operation None 5. Modulating burner operation None 6. Reduced mode None total reduction is possible 7. Weekend setback None total reduction is possible 5614 838 GB 8 VIESMANN VITOCROSSAL 300

Design information Installation for open flue operation (B 23 ) For open flue combustion equipment with a total rated output in excess of 50 kw, the fresh ventilation is deemed to have been verified if the combustion equipment is located in areas which provide an aperture or duct leading outdoors. The cross-section of the aperture must be at least 150 cm 2 and must be 2 cm 2 larger for each additional kw above 50 kw rated output. Pipes must be sized to provide equivalent flow rates. The required cross-section may be split over a maximum of two apertures or pipes. Neutralisation During condensation an acidic condensate with a ph value of between 3 and 4 is produced. This condensate can be neutralised by processing it through a neutralising system. For further information, see the technical guide and "Boiler accessories" datasheet. Installation of a suitable burner The burner must be suitable for the relevant rated heating output and the pressure drop on the hot gas side of the boiler (see burner manufacturer's specification). The material of the burner head must be suitable for operating temperatures of at least 500 C. The blast tube must have a minimum length of 140 mm (see page 4). The burner must be tested to EN 676 and be identified with the CE designation in accordance with Directive 90/396/EEC. Burner adjustment Adjust the gas throughput of the burner to the rated boiler heating output. Further information on design/engineering See the technical guide to this boiler. Tested quality CE designation according to current EC Directives. 5614 838 GB VITOCROSSAL 300 VIESMANN 9

Subject to technical modifications. Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com 5614 838 GB 10 VIESMANN VITOCROSSAL 300

VIESMANN VITOCROSSAL 300 Gas condensing boiler 787 to 1400 kw Datasheet Part no. and prices: see pricelist VITOCROSSAL 300 Type CR3B Gas condensing boiler for natural gas E, LL and LPG 5606 748 GB 9/2011

Benefits at a glance Standard seasonal efficiency [to DIN]: up to 98 % (H s ) [gross cv] / 109 % (H i ) [net cv]. The stainless steel, corrosion-resistant Inox-Crossal heat exchanger ensures high operational reliability and a long service life. Inox-Crossal heat exchanger for highly effective heat transfer and condensation rate. Self-cleaning effect through smooth stainless steel surface. Clean combustion through low combustion chamber loading and straight-through design. As Unit version with Elco or Weishaupt pressure-jet gas burner. Split version for easy handling. Two return connectors for hydraulic connection optimised for condensing technology. Easy-to-use Vitotronic control unit with plain text and graphic display. A Two return connectors B Stainless steel combustion chamber C Highly effective thermal insulation D Inox-Crossal heat exchanger made from stainless steel 5606 748 GB 2 VIESMANN VITOCROSSAL 300

5606 748 GB Specification Specification Rated heating output T V/ T R = 50/30 C kw 787 978 1100 1400 T V /T R = 80/60 C kw 720 895 1006 1280 Rated heat input kw 742 923 1038 1320 Product ID CE-0085AU0315 Permiss. operating temperature C 100 100 100 100 Permissible flow temperature C 110 110 110 110 (= safety temperature) Permiss. operating pressure bar 6 6 6 6 Pressure drop on the hot gas side Pa 420 420 460 480 mbar 4.2 4.2 4.6 4.8 Boiler body dimensions Length b mm 2894 3094 3193 3543 Width c mm 960 960 1200 1200 Height (incl. connectors) mm 1676 1676 1676 1676 Module dimensions Length of the combustion chamber mm 1938 2138 2237 2587 module g Length of the heat exchanger module mm 1198 1198 1216 1216 o Overall dimensions Total length a mm 3021 3221 3338 3688 Overall width of thermal insulation mm 1114 1114 1296 1296 Total width incl. control unit f mm 1281 1281 1463 1463 Total height mm 1550 1550 1550 1550 Foundations Length mm 3100 3350 3450 3900 Width mm 1200 1200 1350 1350 Weight Combustion chamber module kg 780 845 1060 1160 Heat exchanger module kg 615 615 720 810 Total weight kg 1553 1635 1980 2185 Boiler with thermal insulation and boiler control unit Content boiler water l 1407 1552 1558 1833 Boiler connections Boiler flow PN 6 DN 100 100 125 125 Boiler return 1 *1 PN 6 DN 100 100 125 125 Boiler return 2 *1 PN 6 DN 100 100 100 100 Safety connection R 2 2 2 2 Drain R 1¼ 1¼ 1¼ 1¼ Condensate drain R ½ ½ ½ ½ Flue gas parameters *2 Temperature (at return temp. 30 C) At rated heating output C 40 40 40 40 At partial load C 30 30 30 30 Temperature (at return temperature C 70 70 70 70 60 C) Mass flow rate (for natural gas) At rated heating output kg/h 1140 1415 1640 2025 At partial load kg/h 340 425 490 605 Available draught Pa 70 70 70 70 to the flue outlet *3 mbar 0.7 0.7 0.7 0.7 Flue gas connection 7 mm 300 300 350 350 Standard seasonal efficiency [to DIN] for heating system temperature 40/30 C % Up to 98 (H s ) [gross cv] / 109 (H i ) [net cv] *1 When connecting 2 heating circuits, connect the heating circuit with the lowest temperature level to boiler return 1. *2 Values for calculating the size of the flue system to EN 13384, based on 10 % CO 2 for natural gas. Flue gas temperatures measured as gross values at 20 C combustion air temperature. The details for partial load refer to 30 % of the rated heating output. Calculate the flue gas mass flow rate accordingly when the partial load differs from that stated above (subject to burner operating mode). *3 The available draughts are achieved with the pressure-jet gas burners (from Weishaupt or Elco) in our product range and with many other pressure-jet gas burners. For alternative draughts, refer to the relevant burner manufacturer. When using the Vitocrossal 300 with moisture-resistant stacks, the draught may be max. 0 Pa. VITOCROSSAL 300 VIESMANN 3

Specification (cont.) Rated heating output T V/ T R = 50/30 C kw 787 978 1100 1400 T V /T R = 80/60 C kw 720 895 1006 1280 75/60 C % Up to 95 (H s ) [gross cv] / 106 (H i ) [net cv] Standby loss q B,70 % 0.25 0.25 0.25 0.25 KTS KR1 87 KR2 SA DB 189 1030 c 330 181 KV RG 300 1550 1470 1676 b e d SCH 311 KTÜ 750 1504 AGA 733 a 102.5 h l m o k n KOA f g 172 E AGA Flue outlet DB Female connection Rp ½ for pressure limiter E Drain R 1¼ KOA Condensate drain R ½ KR 1 Boiler return 1 KR 2 Boiler return 2 Dimensions Rated heating output kw 787 978 1100 1400 a mm 1114 1114 1296 1296 b mm 302 302 352 352 c mm 673 873 972 1322 d mm 590 590 669 669 e mm 1726 1926 2025 2375 f mm 960 960 1200 1200 g mm 1281 1281 1463 1463 h mm 1198 1198 1216 1216 k mm 1703 1903 2002 2352 l mm 2785 2985 3085 3435 m mm 2894 3094 3193 3543 n mm 1938 2138 2237 2587 o mm 3021 3221 3338 3688 KTS Boiler water temperature sensor Rp ¾ KTÜ Boiler door KV Boiler flow RG Female connection Rp ½ for additional control equipment SA Safety connection R 2 SCH Inspection port Where access to the boiler room is difficult, remove the boiler door and the flue gas header cover. 5606 748 GB 4 VIESMANN VITOCROSSAL 300

Specification (cont.) Siting Minimum clearances 200 (100) To enable convenient installation and maintenance, observe the stated clearance dimensions; maintain the minimum clearances where space is tight (dimensions in brackets). In the delivered condition, the boiler door opens to the right. You can reposition the hinge pins so that the door opens to the left. A B 500 (50) a Siting Avoid air contamination by halogenated hydrocarbons (e.g. as in sprays, paints, solvents and cleaning agents) Avoid very dusty conditions Avoid high levels of humidity Prevent frost and ensure good ventilation Otherwise, the system may suffer faults and damage. In rooms where air contamination through halogenated hydrocarbons may occur, install the boiler only if adequate measures can be taken to provide a supply of uncontaminated combustion air. 400 (300) 500 (50) 1600 Dim. a: Installed burner length A Boiler B Burner Pressure drop on the heating water side 100 80 70 60 50 40 30 The Vitocrossal 300 is only suitable for fully pumped hot water heating systems. 20 Pressure drop in mbar 10 8 7 6 5 4 3 2 1 10 20 30 40 50 60 80 Flow rate in m³/h 5606 748 GB VITOCROSSAL 300 VIESMANN 5

Delivered condition Standard delivery: Boiler body with thermal insulation (Combustion chamber and heat exchanger module are only supplied separately.) Boiler control unit, fully wired Boiler door with burner plate Mating flanges with screws and gaskets Connection for safety equipment no additional intermediate flow piece required Suitable pressure-jet gas burners are available from Weishaupt or ELCO and should be ordered separately (see pricelist). Delivery by the burner manufacturer. The use of burners from other manufacturers is possible. Control unit versions For single boiler systems: Without Vitocontrol control panel Vitotronic 100 (type GC1B) For operation with a constant boiler water temperature or for weather-compensated operation in conjunction with a control panel (see below) or an external control unit. Vitotronic 200 (type GW1B) For modulating boiler water temperature Without mixer control Vitotronic 300 (type GW2B) For modulating boiler water temperature With mixer control for up to 2 heating circuits with mixer With Vitocontrol control panel Vitotronic 100 (type GC1B) and Vitocontrol control panel with Vitotronic 300-K (type MW1B) for weather-compensated operation and mixer control for up to 2 heating circuits with mixer and additional Vitotronic 200-H, type HK1B or HK3B for 1 or up to 3 heating circuits with mixer or Control panel with external control unit (on site) Without Vitocontrol control panel Vitotronic 100 (type GC1B) and LON module in conjunction with a Vitotronic 300-K (type MW1B) for modulating boiler water temperature (one boiler is supplied with the standard control equipment for a multi boiler system) and Vitotronic 100 (type GC1B) and LON module for modulating boiler water temperature for each additional boiler in a multi boiler system With Vitocontrol control panel Vitotronic 100 (type GC1B) and LON module for modulating boiler water temperature for each boiler in a multi boiler system and Vitocontrol control panel with Vitotronic 300-K (type MW1B) for multi boiler system, weather-compensated operation and mixer control for up to 2 heating circuits with mixer and additional Vitotronic 200-H, type HK1B or HK3B for 1 or up to 3 heating circuits with mixer or Control panel with external control unit (on site) For multi boiler systems: (up to 4 boilers) Boiler accessories See pricelist and "Boiler accessories" datasheet. Operating conditions Operating conditions with Vitotronic boiler control units For water quality requirements, see the technical guide "Standard values for water quality" Requirements 1. Heating water flow rate None 2. Boiler return temperature (minimum value) None 3. Low-end boiler water temperature None 4. Low-end boiler water temperature with frost protection 10 C ensured through the Viessmann control unit 5. Two-stage burner operation None 6. Modulating burner operation None 7. Reduced mode None total reduction is possible 8. Weekend setback None total reduction is possible Design information Installation for open flue operation (B 23, B 33 ) 5606 748 GB 6 VIESMANN VITOCROSSAL 300

Design information (cont.) For open flue combustion equipment with a total rated output in excess of 50 kw, the fresh ventilation is deemed to have been verified if the combustion equipment is located in areas which provide an aperture or duct leading outdoors. The cross-section of the aperture must be at least 150 cm 2 and must be 2 cm 2 larger for each additional kw above 50 kw rated output. Pipes must be sized to provide equivalent flow rates. The required cross-section may be split over a maximum of two apertures or pipes. Neutralisation During condensation an acidic condensate with a ph value of between 3 and 4 is produced. This condensate can be neutralised by processing it through a neutralising system. For further information, see the technical guide and "Boiler accessories" datasheet. Installation of a suitable burner The burner must be suitable for the relevant rated heating output and the pressure drop on the hot gas side of the boiler (see burner manufacturer's specification). The material of the burner head must be suitable for operating temperatures of at least 500 C. The blast tube must be at least 135 mm long. The burner must be tested to EN 676 and CE-designated in accordance with Directive 90/396/EEC. Burner adjustment Adjust the gas throughput of the burner to the rated boiler heating output. Burner connection The blast tube aperture meets the requirements of EN 303-1. Use the burner plate (part of the standard delivery) to mount the burner. If the plate is not factory-fitted, drill the burner fixing holes into the burner flange and cut out the burner aperture with an oxy-acetylene torch. Max. blast tube aperture Ø 350 mm. In the case of different dimensions, adjust the cut-out in the thermal insulation of the boiler door according to the blast tube diameter. After the burner installation, seal the annular gap between the blast tube and the thermal insulation block with the heat-resistant insulation material supplied. Burner plates may be factory-fitted on request (chargeable option). For this, please state the burner make and type when ordering. The blast tube must protrude through the thermal insulation on the boiler door. Further information on design/engineering See the technical guide to this boiler. Tested quality CE designation according to current EC Directives. Qualitätsmarke der ÖVGW gem. Gütezeichenverordnung 1942 DRGBl. I für Erzeugnisse des Gas- und Wasserfachs. 5606 748 GB VITOCROSSAL 300 VIESMANN 7

5606 748 GB Printed on environmentally friendly, chlorine-free bleached paper Subject to technical modifications. Viessmann Werke GmbH&Co KG D-35107 Allendorf Telephone: +49 6452 70-0 Fax: +49 6452 70-2780 www.viessmann.com Viessmann Limited Hortonwood 30, Telford Shropshire, TF1 7YP, GB Telephone: +44 1952 675000 Fax: +44 1952 675040 E-mail: info-uk@viessmann.com 8 VIESMANN VITOCROSSAL 300