3102
A very warm welcome to The Decora Group the management and holding company for Domoteck and Climateck Industries. Focusing on making modern living comfortable, the Decora group has developed some innovative and creative heating / cooling solutions, and through our respective companies Domoteck & Climateck we manufacture and market a full range of heating & c o o l i n g s y s t e m s t h a t a r e g u i d e d b y t h e p r i n c i p l e o f "Low Temperature Heating" Domoteck produces and markets, a collection of high quality electrical underfloor radiant heating systems. That are energy e f f i c i e n t, m a i n t e n a n c e f r e e a s w e l l a s. "Simple & Perfect". Climateck produces and markets advanced hydronic systems setting new standards in protecting the environment, bringing the best of heating & cooling tech nology to your home. To operate both our electrical and hydronic systems we have a wide range of Control units to optimize performance FLOOR and ensure WARMING PRODUCTS maximum efficiency and safety. We also offer a selection of appliances purely for comfort, enjoyment and problem solving. 2 2
Indoor floor warming Mordern Building Energy saving Better insulation Increased comfort Floor warming - Wet installation - Dry installation Max. Floor temp. 27 C Wet installation Dry installation Thermostat installed on outside bathroom wall Thermostat Conduit Conduit Junction box Flooring Junction box Flooring Sensor FWM embedded Construction Insulation of the building Sensor FWM Installed on Construction Insulation of the building Sub-floor Sub-floor 4 4
Heating mat installed directly under the flooring Correct Temp. Difference: Above the heating element and between the heating element will be less than 1 C if watt per linear meter is less than 8.5W, 170W/m 2 5cm Distance between heating wire Wrong Temp. Difference: Above the heating element and between the heating element will be less than 2 C if watt per linear meter is less than 17W, 170W/m 2 10cm Distance between heating wire 5 5
6 6
Domoteck manufactures heating elements in different widths Lengths can be between 2m to 16m (2,4,6...16) 7 7
CABLE THICKNESS IMPORTANT FACTS FOR INSTALLATION FOR CABLE: A. Thickness of cable (build up) B. Distance of Cable (install. distance) C. Deepness of cable (of installation) FOR MAT: A. Thickness of cable (build up) B. Distance of cable (install. distance) C. Deepness of mat (of installation) D. Width of mat A A B B C C D 8 8
Product Name Underfloor Warming Products Electrical Mats Output Mat Output Cable Voltage Last layer cable First layer cable Size Wire Thickness Domotherm Classic Twin Mat FWM 2 S 1-975 120W/m 2 150W/m 2 9.6W/lm 12W/lm SCREEN 2.0mm 3m²-12m² Domotherm Mat FWM 1 S 1-970 120W/m 2 150W/m 2 7.5W/lm 9.5W/lm SCREEN 2.0mm 0.60m²-3m² Classic mat FWM 2 S 1-813 120W/m 2 160W/m 2 7.5W/lm 10W/lm PVC 3.5mm 1m²-8m² TFM-S Thermofloor Comfort Mat FWM 2 S 1-239 150W/m 2 11.11W/lm XLPE 1m²-8m² 3mm Thinnest Mat IVC FWM 1 B 1-871 120W/m² 7.5 W/lm PA 2.6mm 3m²-12m² Aluminium Mat Twin/S FWM 2 S 1-536 100W/m 2 150W/m 2 5.0W/lm 7.5W/lm SCREEN 2.0mm 1m²-8m² Fix Size (FS) Aluminium Mat FWM 1 N 1-510 100W/m 2 150W/m 2 5.0W/lm 7.5W/lm PA 2.0mm 0.50m²-3.5m² Aluminium Mat Single/s FWM 1 S 1-531 100W/m 2 150W/m 2 5.0W/lm 7.5W/lm SCREEN 2.0mm 1m²-8m² Aluminium CCPE FS FWM 1 N 1-945 120W/m² 6.0W/lm PA 2.0mm 0.25m²-3.5m² 9 9
Underfloor Warming Products Electrical Mats & Cables Bathroom Product Name Output Mat Output Cable Voltage Last Layer cable First layer cable Size Wire Thickness TFM-S Comfort Kit Mat FWM 2 S 1 239 150W/m 2 11.11W/lm XLPE 3.0mm 1.2m²-6m² TFM-S Comfort Mat FWM 2 S 1-239 150W/m 2 11.11W/lm XLPE 3.0mm 3.6m²-6m² TFC-S Comfort KIT Loose cable FWC 2 S 1-670 10W/m 2 XLPE 3.0mm 16m-80m Classic mat FWM 2 S 1-813 160W/m 2 200W/m 2 10W/lm 12.5W/lm PVC 3.5mm 0.6m²-4.8m² Shower Mat IVC FWM 1 B 2-540 200W/m 2 16W/lm PVC 0.64m² 4.3mm Easy Fit FWM 2 S 1-559 160W/m 2 TO 120W/m² 10W/lm PVC 3.5mm 1.2m²-4.8m² Thin Braided Cable IVC FWC 1 B 1-681 10W/lm PA 2.6mm 10m-120m PA 4.5mm Classic cable FWC 2 S 2 645 10W/lm 10m-150m Thinnest Mat IVC FWM 1 B 1-871 160W/m² 10 W/lm PA 2.6mm 2m²-8m² 01 10
Underfloor Heating Products Electrical Mats & Cables Product Name Output Mat Output Cable Voltage First layer cable Last layer cable size Wire Thickness Multitherm heating mat FHM 2 S 3-960 120W/m (50w/ m²+70w/m²) 17w/lm (7w/lm+10w/ lm) PVC 1m²-8m² 5.6mm Universal Thermosol FE Mat FHM 2 B 3 810 106W/m ² 17W/lm PVC 1.40m²- 24.50m² 5.6mm Classic Thermosol FE Cable FHC 2 B 3 676 17W/lm PVC 8.80m- 152.90m 5.6mm Universal thermosol XL Mat FHM 2 B 4-809 106W/m 2 17W/lm XLPE PVC 1.40m²- 24.50m² 6.2m² Classic thermosol XL Cable FHC 2 B 4-634 17W/lm XLPE PVC 8.80m- 152.90m 6.2mm Basic FH Mat FHM 2 B 4-753 170W/m² 17W/lm XLPE XLPE 1m²-12m² 6.0mm Basic FH Cable FHC 2 B 4-663 17W/lm XLPE XLPE 10m-120m 6.0mm 00 11
Frost Protection Mats & cables Product Name Output Mat Output Cable Voltage Last layer cable Wire Thickness size Anti Frost Mat AFM 1 B 3-746 (740) 300W/m 2 30Wlm 400V PVC 1m²-16m² 5.6cm Stairs De-icing Mat 300W/m 2 30Wlm PVC 5.6cm AFM 2 B 4-804 1.2m²-3.6m² De-icing Cable EPB AFC 2 B 4-637 18W/lm 30W/lm Polyolefin UV protected 4m-40m 7mm De-Icing IVC Cable AFC 1 B 3-658 30W/lm 400V PVC 5.6cm 10m-120m 50m-180m Anti Freeze Pipe Cable+ Thermo Switch AFC 2 B 4-604 17W/lm Polyolefin UV protected 7mmx5mm Oval Dim. 2m-40m Anti Freeze Pipe Cable SLR+ Thermo Switch AFC 2 B 4-662 25W/lm Polyolefin UV protected 7mmx5mm Oval Dim. 5m-30m De-Icing Cable SLR-SA Pre-assemble AFC 2 B 4-608 25W/lm Polyolefin UV protected 7mmx5mm Oval Dim. 5m-30m De-icing SLR Cable AFC 2 B 4-607 15W/lm 25W/lm Polyolefin UV protected 7mmx5mm Oval Dim. 50m-300m 02 12
Frost Protection Outdoor Control Units Accessories Product Name Product Name Thermostat Cu 100 TE 9725 420 060 Gutter Sensor 9725 420 161 Sensor base Humidity sensor 9725 420 062 CU 125- SAF Gutter De-icing Thermostat 9725 420 137 Cable holder 9721 440 142 Gutter Claps 9721 440 262 AC 709 Carrying Wire 9721 440 143 Support Hook 9721 440 257 Holding Bracket 9721 440 255 Accesories and Connection for SLR Anchor Plate 9721 440 254 Product Name Support Spring 9721 440 256 Cold lead 3 1mm² black 9721 490 239 Shrink Connection Set for SLR 9725 440 036 Sensor Pipe 5m UV 9721 440 252 SLR CAP AC 712 9721 440 103 01 13
Comfort Products for Office & More Product Name Width Length Voltage Watt per Unit Underlay AP 601 9721 400 006 1.30m 1.80m 480W 9721 400 003 1.30m 1.80m 300W Office Mat AP 602 9721 400 002 0.50m 0.70m 65W 9721 400 004 0.60m 0.90m 95W PVC Mat AP 607 9721 400 063 0.55m 0.55m 75W 9721 400 064 0.55m 0.75m 105W PVC Shoe Mat AP 608 9721 400 090 0.35m 0.75m 65W Heating panel personal Use RHP 150 9723 410 140 0.57m 0.40m 150W Heating panel UW installation RHP 300 9723 410 141 0.35m 1.10m 300W 04 14
Comfort Products for Bathroom Product Name Width Length Voltage Watt per Unit Fog Free Mirror AP 603 9721 400 000 0.45m 0.50m 50W 9721 400 001 0.60m 0.75m 110W Small Towel Dryer AP 606 9723 410 074 0.37m 0.33m 33W Mid Bath Towel Dryer AP 605 9723 410 005 0.40m 0.70m 65W Large Bath Towel Dryer 9723 410 075 0.60m 0.70m 98W Diagonal Towel Dryer AP 604 9723 410 004 0.56m 0.66m 100W Bath Radiant heating panel RHP 310 9723 410 153 0.425m 0.80m 300W 05 15
Thermostat with room sensor Product Name Application Voltage CU 333- SR 9725 420 156 Programmable 200V - CU 520 S-R 9725 420 116 Programmable 200V- CU 345-STT/R 9725 420 181 Programmable 200V- CU 543-STT/R 9725 420 182 Programmable 200V- CU 456 S/R 9725 420 179 Non Programmable Simple and effective 200V- CU 654 S/R 9725 420 180 Non Programmable Simple and effective 200V- CU 517 S/R 3232 031 180 Non Programmable 200V- 06 16
Control Thermostat Units with floor sensor Product Name Application Voltage CU 333 S-F 9725 420 155 Programmable 110V - CU 518 M-F 9725 420 091 Non Programmable 200V- CU 522-ST Universal Timer 9725 420 132 Timer CU 345-STT 9725 420 167 Programmable 200V- CU 543-STT 9725 420 168 Programmable 200V- CU 456 SF 9725 420 177 Non Programmable 200V- CU 654 SF 9725 420 178 Non Programmable 200V- CU 520 S-F 9725 420 093 Programmable 200V- 07 17
Testing Instruments Product Name Application Voltage Megger Meter TI 610 9725 420 081 Insulation Tester Multimeter Dk Fault Locator TI 611 9725 420 082 Identifies shortcut Fault Indicator TI 612 Fault Indicator 9725 420 124 Infra red camera TI 613 Identifies shortcut 9725 420 125 Variac TI 614 Identifies shortcut 9725 420 126 Transformer TI 615 Identifies shortcut 9725 420 127 08 18
Accessories for Mats & Cables Product Name Units Applications Tube for Sensor 12mm 1.5 m 9721 440 219 1 unit Installation of Thermostat Sensor 90 0 C Angle AC 704 8-12 9721 440 218 1 unit Fixing Sensor Tube in place Installation Kit AC 718 Including pipe 14/2+2.2m+angel +corrugated 2.5 m+ electrical box 9721 470 095 1 set Installation of control unit CCPE Insulation Layer AC 705 1 20 9721 440 089 20m² Installation under the Aluminium Mat CCPE Insulation mats AC 705 0.50 x 0.50-6 units 1.5m2/4mm 9721 440 194 1.5m² Installation under the Aluminium Mat Blind Net AC 707 0.5 10 9721 440 001 5m² To be framed around the Aluminium mat to level off the floor height Plastic Nails AC 714 100 unit 9721 440 136 100 units Fixing mats into place Aluminium adhesive tape 50m 9721 440 199 50m fixing cable to the sub floor Fixing Strip Aluminium Length 10mm Cables - 3.3mm 9721 440 104 9721 440 110 10m 10m Spacing loops - 25mm Spacing loops - 30mm Fixing Strip Aluminium Length 1mx5 unit 9721 440 123 1m X 5 unit Cables Spacing loops - 50mm Ecc 3 ( electrical connection chain) 9721 440 894 Ecc 5 (electrical connection chain) 9721 440 895 1 unit 1 unit ECC-connection ECC-connection Grippers 6 units per meter of mat To fix the easy fit mat 09 19
WBS- Manifolds Item Description Article Number SDU A 3Loops - 9723 460 511 4Loops - 9723 460 512 5Loops - 9723 460 513 SDU B SDU B V 2Loops - 9723 460 312 3Loops - 9723 460 313 4Loops - 9723 460 314 5Loops - 9723 460 315 6Loops - 9723 460 316 7Loops - 9723 460 317 8Loops - 9723 460 318 2Loops - 9723 460 491 3Loops - 9723 460 492 4Loops - 9723 460 493 5Loops - 9723 460 494 6Loops - 9723 460 495 7Loops - 9723 460 496 8Loops - 9723 460 497 SDU Z P V 4Loops - 9723 460 404 SDU AS P V ET 5-8 WL 5Loops - 9723 460 600 6Loops - 9723 460 601 7Loops - 9723 460 602 8Loops - 9723 460 603 21 20
WBS- ADU Stand-Alone Systems Item Description Article Number ADU 1-2 9723 460 276 ADU 3-4 9723 460 277 ADU 5-8 5Loops - 9723 460 515 6Loops - 9723 460 516 7Loops - 9723 460 517 8Loops - 9723 460 518 ADU 2M 2L 2 x 6 kw 9723 460 584 ADU 2M 10L 2 x 6 kw 9723 460 585 21
WBS - Heat Pumps & Systems Connecting to Heat Pumps Heat Pumps Description Article Number Heat Pump VOP HX 24,000 Btu 9723 460 577 Heat Pump B HX 18,000 Btu 9723 460 467 Heat Pump B 18,000 Btu Heat Pump B 24,000 Btu Heat Pump B 36,000 Btu 9723 460 458 9723 460 459 9723 460 461 Systems Description Article Number Interface C And control box 9723 460 501 Manifold for Interface 9723 460 489 Standard Energy Unit 9723 460 470 22
WBS - Pipes Pipes Description Article Number Dowlex-Pipe 8/1.2 mat 0.5 x 2.0 = 1.0 Dowlex-Pipe 8/1.2 mat 0.5 x 4.0 = 2.0 Dowlex-Pipe 8/1.2 mat 0.5 x 6.0 = 3.0 Dowlex-Pipe 8/1.2 mat 0.5 x 8.0 = 4.0 9723 305 008 9723 305 009 9723 305 010 9723 305 011 Dowlex-Pipe 8/1.2-Made of Dowlex with oxygen barrier layer in rolls of 200m 9723 300 038 Dowlex-Pipe 16/2-Made of Dowlex with oxygen barrier layer in rolls of 90m&200m 9723 300 017 9723 300 020 ACU Concealed 12000 Btu 15000 Btu 9723 460 480 9723 460 481 ACU Wall 12000Btu 3 speed 9723 460 523 ACU Wall 16000Btu 3 speed ACU floor OS 9000Btu 12000Btu 9723 460 472 9723 460 473 23
WBS Accessories Pipes Description Article Number Oval Pipe DOWLEX Orange Made of Dowlex with oxygen barrier layer 17 x 24 x 2.5mm in rolls of 200m 9723 300 027 Welding Nipple To connect the Oval Pipe 9723 460 274 Manifold Connection 21 x 2.5mm round pipe with 90 Bow Oval 9723 460 279 Elbow 90 Round/Oval Connection between 21 x 2.5mm Round Pipe and Oval Pipe 9723 460 272 Manifold Connection Pipe OV-AR 21 x 2.5mm - Length 1.0m Red 9723 300 028 Elbow 90 Oval/Oval To connect the Oval Pipe to cross vertical level differences 9723 460 273
WBS Accessories Product Description Blind Cap 3/4 -To close a not needed outgoing & in going circuit. Connector Nipple 3/4 Eurocone Nickel Plated to be installed at the Blank Port to add additional loops Pipe Fitter - Consisting of cap nut 3/4 Clamping Ring & Pipe Spout. To fix the Round Pipe to the manifold by 3/4 Euro cone. 16mm (16 x 2.5mm round pipe) 17mm (17 x 2.5mm round pipe) 20mm (20 x 2.5mm round pipe) 9723 460 423 9723 460 426 9723 420 069 9723 420 087 9723 420 076 Regulating Valve To be installed in the water outlet bar 9723 460 424 Thermostatic Valve To be installed in the water inlet bar 9723 460 425 Ball Valves - R1, Brass Nickel Plated 9723 460 427 Flow Meter - Balancing Valve Direct regulation, reading & shut-off of flows in systems 9723 460 406 Filling & Draining Valve - To be installed at the end of the water inlet & water outlet bar 9723 460 421 WBS-FRC Unit - Electrostatical Valve. Thermostat to open and close valve Sensor + Tube Black Angle 90 x 1 per loop 9723 410 125 Domo RTL AC WB 723 9723 410 096 Installation Box RTL AC WB 727 9723 410 112 25
WBS Accessories Product Description CU HA 535-S Thermostat for Home Acclimatization Systems 9723 420 147 CU 543-SR Thermostat 9725 420 168 Actuator type Alpha To open and close the water flow each loop Cable length 1m 9723 420 070 Terminal Strip - To connect the Thermostat to the Actuators Ventilation 1/2 To be installed at the Blank Port as needed Header Cabinet H500xW530 built-in installation made from Galvanized Sheet Metal Front powdered white RAL 9010 Available in 3 sizes - Dimensions on request 9723 450 123 9723 460 422 9723 410 137 26
WBS WBS Accessories Installation Description Black Angles - To help prevent the Pro-Pipe from breaking when connecting to the SDU-A. 9723 440 097 Hooks - To Fix the 16mm - 20mm Pro-Pipe to the Domo-ISO RJ system panel. 9723 440 190 Fixing Strips- anchoring the 8mm/200m Pro -Pipe 9723 440 123 Polyethylene Foil- To lay over the insulation for separation from the concrete. Thickness -0.2 Width - 2.0 m Folded to 1m rolls of 35m. Domo-ISO RJ System Panel Insulation Panel with foil backing & printed grid - 50mm distances. 9723 440 206 9723 440 189 Domo-ISO HP 1000x500mm AC WB 718 9723 440 187 Domo-ISO HP 1000x500mm AC WB 711 9723 440 186 Security Border Strip- 160 x 8mm with PE Strap to connect to the system panel. 9723 440 203 Tools Description Pipe Cutter - cutting the Dowlex -Pipe to the required length of the loops. 9723 440 213 Stapling Machine - To insert the hooks with the Pro-Pipe to the Domo-ISO RJ System Panel. 9723 440 191 27
Contact Information: info@domoteck.com www.domoteck.com 28 28