SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER

Similar documents
Beijing Holtop Artificial Environment Technology Co., Ltd

Mystery of Sustainable Heat Exchange Material Heat Recovery Ventilator(HRV)

EU Air Handling Units with SEMCO EXCLU-SIEVE

39G Air Handling Unit

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Material and rotor description.

ETA ACCU 90% HIGHEST EFFICIENCY AIR HANDLING UNIT

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

ASHRAE Region VI CRC Track III: Session 3 Ventilation Energy Recovery. Steven T. Taylor, PE Principal Taylor Engineering

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

HRV Brochure. Heat Recovery Ventilation

AIR HANDLING UNITS ZHK 2000

YAH Series Air Handling Units

YAH SERIES FAN COIL UNITS

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Horizontal rotor heat recovery ventilation unit RH 5. Vertical rotor heat recovery ventilation unit RV 9

Double Skin Air Handling Units

Heat pump and energy recovery systems

TEVHR. Heat Recovery Ventilator

Economical, Flexible, Advanced Performance. Ventilation and Dehumidification for Healthy IAQ

GUIDE SPECIFICATIONS FOR AIR HANDLING UNITS VENTILATION UNITS & HEAT RECOVERY UNITS

SAFETY AND INSTALLATION MANUAL MODEL 8100

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

Indoor Air Quality. For assured. Double Skin Air Handling Units

WATER TO AIR DUCTABLE INDOOR HORIZONTAL HEAT PUMP

Double Skin Air Handling Units

AIR COOLED ROOFTOP UNITS, COOLING CAPACITY FROM 50 TO 240 kw, AIRFLOW FROM TO m3/h

CHAPTER 4. HVAC DELIVERY SYSTEMS

Heat Recovery Units. Heat Recovery 1

FHE FHE. Dehumidifiers for radiant cooling systems with heat recovery. Versions

Put the V back in HVAC

Fans Air Handling Units Air Distribution Products Fire Safety Air Conditioning Air Curtains and Heating Products Tunnel Fans. Geniox.

Air handling units KLASIK. Unique solutions available Flexible performance & economy Reliable, stable & efficient Tight casing & perfect insulation

GHE Dehumidifiers for radiant cooling systems with heat recovery

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

AIR TREATMENT. ReCOOLER HP» INTEGRATED COOLING/HEATING FUNCTION WITH REVERSIBLE HEAT PUMP IN THE eq AIR HANDLING UNIT

Modular Air Handling Unit

AIR CONDITIONER PERFORMANCE RATING

COOLING and DE-HUMIDIFICATION WITHOUT USING REFRIGERANTS

Air flow m3/h

Air is our element. energy recovery our passion. Rotors overview. Quick guide GOST VDI 6022

PRODUCT CATALOGUE THE PROMISE THE PROOF HEATEX AIR-TO-AIR HEAT EXCHANGERS

Contents. How to choose Recovery Ventilation type?...3. How do HRV, ERV and TRV Systems work?...4. Types of installations...5. VUT 200 H mini...

Mikael Börjesson Product manager. Commercial air handling units Ventilation functionality Building management system integration

Centeral Station Air Handling Unit

GHE. Dehumidifiers for radiant cooling systems with heat recovery. Display

AHU Plus. DX Air Handling Units

VERSO Air Handling Units

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Double Skin Casing Air Handling Units

DES CHAMPS PRODUCTS 85% 4,400 CFM

MECHANICAL VENTILATION

» WITH REGASORP ROTARY HEAT EXCHANGER

Whole Home Heat Recovery Ventilation

AIR HANDLING UNITS MANDÍK

GHE GHE. Dehumidifiers for radiant cooling systems with heat recovery VERSIONS ACCESSORIES

The ultimate in air handling units: directly and indirectly fired

EHH SERIES DRAW THROUGH FAN COILS CFM

Why should you opt for ENTHALPY. Wheels for your. AHUs. ERVs. (Energy Recovery Ventilators) (Air Handling Units) from

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

The ultimate in air handling units: directly and indirectly fired

INDUSTRIAL DEHUMIDIFIERS. Advanced range of compressor and desiccant dehumidifiers. Dehumidification and drying

Indholdsfortegnelse. Danvent Air Handling Units SERVICE MANUAL

Rotary heat exchangers

FLOWAY. Floway Range. The dual-flow air handling unit with heat recovery guaranteeing an Economical and Durable solution. use.

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

Compact, Self-Contained unit that offer low installation cost plus dependable performance.

Air Handling Units. Geniox. Quick guide

Residential Heat & Energy Recovery

Enthalpy Wheel and its Application in Air Conditioning

Rotors overview. Quick guide GOST VDI 6022

The ultimate in air handling units: directly and indirectly fired

Bill McCullough. Director ERV Products. Dallas, TX

AIR HANDLING UNITS. Revision AG 16-07

Review on Waste Heat Recovery Techniques in Air Conditioning Application

White Paper. Executive Summary. Overview of Membrane Exchangers CLCH-PRB063A-EN. June 2017

Liquid Desiccant Air Conditioning Systems

On the cover Integrated professional services designed for your unique business need.

Easdale International INFINITY


TopMaster Air Handling unit. Technical data

The ultimate in air handling units: directly and indirectly fired

WHHR Midi & Midi Lite

Heat Recovery Unit (Aluminium Plate) Energy Recovery Unit (Rotary)

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Pharmaceutical Facility Design

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

VERSO Air Handling Units

Heat Recovery Ventilator Model PVe Light Industrial Commercial Institutional

Integrated VarIable refrigerant flow ahu/pau (r410a)

Resolair 62 and 66. Comfort air conditioning unit with highly efficient regenerative heat storage packages. AIR VOLUME FLOW: 1,200 4,300 m³/h

ReCooler Heat-Pump Energy efficient cooling unit for eq Air Handling Unit

USER S MANUAL. Heat (Energy) Recovery Ventilator. Vents Frigate HRV 120 S Vents Frigate ERV 120 S

DOMEKT ReGO 400VE(W)-B Series Air Handling Units Installation and Maintenance Service Manual

Duct Type Fan Coil Unit. Air flow: 680~4590m 3 /h Cooling capacity: 3.7~22.6kW

FUJITSU VRF 2016/17 PRODUCT CATALOGUE VRF MULTI SPLIT VRF VENTILATION

The plug & play fresh Air Solution

Transcription:

SUSPENDED AIR HANDLING UNIT WITH ROTARY HEAT EXCHANGER Energy Recovery Ventilation Specialist Beijing Holtop Artificial Environment Technology Co., Ltd ISO 9001: 2000 Approved Company

COMPANY BRIEF INTRODUCTION TO COMPANY ENERGY RECOVERY VENTILATION SPECIALIST Holtop is dedicated to the research and technology development in the filed of indoor air quality. It is the leading company in China who professionally produces heat recovery ventilation system. Covering a land of 20000 square meters, Holtop was created in May, 2002 furnished with first-class plants and equipments. Through innovation, it developed its own key components like plate and rotary heat exchangers for various heat & energy recovery systems. It provides now full lines of products covering 5 series and 98 specifications which can basically satisfy the needs of various airflows and installations worldwidely. Holtop is trusted by the users for its advanced technology, superb product quality and all-around services. By the end of year 2006, Holtop has supplied successfully to over 3000 customers in the domestic market and exported its products to Japan, Korea, Russia, Italy, Belgium, Australia, New Zealand, etc. Let's join together to contribute to our commitment of energy saving and pollution reduction. 2

CONTENTS BRIEF INTRODUCTION TO COMPANY 02 UNDERSTANDING MODEL NUMBER AND AIRFLOWS 04 SPECIFICATIONS AND DIMENSIONS 05 MAIN FEATURES AND COMPONENTS 06 MAIN FEATURES AND COMPONENTS 07 INSTALLATION, OPERATION AND MAINTENANCE 08 3

UNDERSTANDING MODEL NUMBER AND AIRFLOWS HDK-02 G P 6 S Y Type of AHU, Z for left and Y for right S- Humidifying Row number of cooling/heating coil, 3/6 rows available P-Plate heat exchanger, R-Rotary heat exchanger Class of filter: G for Coarse, F for Medium Nominal airflow multiplied by 1000m3/h Holtop suspended energy recovery AHU Judging left or right type Look at the direction of supply air, it s left type if water pipes on the left; otherwise, it s a right type. For standard AHU, service door, wiring port and water pipe of heating/cooling coils locate at the same side. OA RA Left EA SA Right Suitable airflow Model Suitable airflow HDK-01 1000m 3 /h~1700m 3 /h HDK-02 1800m 3 /h~2800m 3 /h HDK-03 2100m 3 /h~3200m 3 /h HDK-04 2700m 3 /h~3900m 3 /h HDK-05 3400m 3 /h~5200m 3 /h 4

SPECIFICATIONS AND DIMENSIONS Specifications Model Airflow (m3/h) External pressure of supply fan (Pa) External pressure of exhaust fan (Pa) Temp. Eff.(%) Noise db(a) Volt. (V) Current (A) Rated N. W. power (Kg) (W) HDK-012 1224 129 179 55 380 1.53 570 250 HDK-013 1337 144 112 55 380 1.53 570 250 Up to 70% HDK-030 3060 189 189 59 380 3.86 2000 320 HDK-033 3394 224 167 59 380 3.73 1700 320 Dimensions H H1 H2 L L1 L2 L3 EA W1 RA W OA W2 SA Model L L1 L2 L3 W W1 W2 H H1 H2 HDK-012, HDK-013 1570 530 510 530 1264 595 595 717 652 493 HDK-030, HDK-033 1570 530 510 530 1264 595 595 921 856 680 5

MAIN FEATURES AND COMPONENTS Main features Equipped with supply fan and exhaust fan, brings in fresh air and exhausts out stale indoor air as well. Equipped with rotary heat exchanger, recovers energy from outgoing indoor air, to save operating cost to the max. Thin height, easily installed in the ceiling space. Housing construction Double skin panel 25mm thick, inner skin made of galvanized steel sheet, outer skin color steel sheet, between skins is sandwiched with high density fireproof PU with thermal coefficient below 0.0199W/m. High air tightness Double inlaid sealing system to tightly join the framework and panels, total air leakage rate below 3%. Supply fan and exhaust fan Outer rotor motor, direct driven centrifugal fan, dynamic balance, compact and low noise level. Filter Plate type(g4) coarse filter as standard configuration. (Bag filter F5~F8 available as per request of customer). Draw-push installation, easy maintenance. 6

MAIN FEATURES AND COMPONENTS Rotary heat exchanger Holtop total heat exchanger (enthalpy recovery wheel) is made of aluminum foil coated with 3A molecular sieve, which enables the wheel to exchange both temperature and humidity, in another word, to recover both sensible and latent heat. Working principle Rotary heat exchanger is composed of heat wheel, case, drive system and sealing parts. The heat wheel rotates powered by the drive system. When outdoor air (OA) passes through half of the wheel, return air (RA) passes through reversely the rest half of the wheel. In this process, about 70% to 90% energy contained in the return air (RA) can be recovered to supply air (SA) to indoor. Technical features Molecular sieve coating 3A molecular sieve coated aluminum wheels have an excellent capacity of moisture absorption even under high temperature, high airspeed and low humidity, and can expel harmful odor gases due to the selective absorption characteristics. Double sealing system Unique design of double sealing system ensure the air leakage below 0.5%. The special soft and dense material achieves better sealing effect and is 3-5 times longer life than ordinary materials. Double purge sector The double purge sector minimizes carryover from the exhaust air into the supply air stream. If the correct pressure difference is provided (200-900Pa), the rate of dust, gases etc. carried over from exhaust air into the supply air is below 0.3%. Self-cleaning The wheel has high self-cleaning effect under normal conditions due to the continuously changing direction of air flow through the wave type channels of the wheel. 7

INSTALLATION, OPERATION AND MAINTENANCE Installation 1. For maintenance purpose, leave enough space around the service door and water ports. Optimal space should be bigger than the length of the heating/cooling coil. Least space should be enough for take-down operation of filters. 2. AHU shall be horizontally installed under ceiling 150~200mm. Shock absorber is required between suspender and lugs. Ceiling bolt should be at least M14 Nut Cushion Underframe Cushion Nut 3. Use seal tape for drainpipe to ensure smooth draining. Connect as per following diagram. AHU H=Max press undertake(mm)+50mm 4. Clean all the water paths before connecting them to the unit. Make gentle connection in order to protect the coil. Weight of valves, pipes and other components beside the AHU should not be borne on the AHU. 5. Use soft fittings to connect the air inlet/outlet of unit and ducts. 6. Supply air should not be higher than 80,otherwise, please inform us before ordering so as to take related measures. 7. AHU housing should be well earthed. Operation and maintenance 1. AHU is powered by TN-S power supply system, i.e. AC3~380V+N+PE. 2. Check and make sure motor runs at right direction and freely. Run the unit after all the electric parts are checked without fault by a professional. 3. Commissioning is required before putting the equipment into use. Motors should be running under rated electric current. 4. Cooling & heating coil should use clean demineralized water as medium, working pressure 1.2MPa. 5. Drain out the water in the coil in winter, and blow away the remains water as far as possible. In case remains water can not be blew away, inject antifreeze into the coil. 6. Examine the filter regularly, clean or replace it if resistance comes to the end resistance. Air-dry the washed filter totally before reuse. 7. Fully clean or maintain the unit after each 1 or 2-year operation. Clean the coils using compressed air or high pressure water. 8

Data is subject to changes without notification due to product improvement Beijing Holtop Artificial Environment Technology Co., Ltd Factory address : No.158 Hanjiachuan Road, Haidian District, Beijing China International marketing center Address: Room 2-1108 Industrial Plaza, Tina An Hi-Tech Ecological Park, No. 730 Yingbin Road, Panyu District, Guangzhou, China Tel:0086-20-39388201 Fax: 0086-20-39388202 Website:www.holtop.com E-mail: contact@holtop.com