PRESSIONAL 1 ONE LINE DIAGRAM 3 EMEGENCY LIGHTING SCHEME 2 FEEDER SCHEDULE
PRESSIONAL
PRESSIONAL
PRESSIONAL
PRESSIONAL
LOCAL SINGLE POLE SWITCH 3-WAY SWITCH 3-WAY SWITCH 1 LINE VOLTAGE SENSOR 2 LINE VOLTAGE SENSOR W/ SINGLE SWITCHING 3 LINE VOLTAGE SENSOR W/ 3-WAY SWITCHING 10 IT GROUND BAR DETAIL LOCAL SINGLE POLE SWITCH 3-WAY SWITCH 3-WAY SWITCH 4 LOW VOLTAGE SENSORS W/ POR PACK 5 LOW VOLTAGE SENSORS W/ POR PACK, SWITCH 6 LOW VOLTAGE SENSORS W/ POR PACK, 3-WAY PRESSIONAL WALL SENSOR LOCAL SINGLE POLE SWITCH 'A' LOCAL SINGLE POLE SWITCH 'A' 7 WALL SWITCH SENSOR W/ EXHAUST FAN (OPTIONAL) 8 LOCAL SINGLE POLE SWITCH 'B' LOW VOLTAGE SENSORS W/ POR PACK, A/B SWITCHING 9 LOCAL SINGLE POLE SWITCH 'B' LINE VOLTAGE SENSOR W/ A/B SWITCHING COPPER GROUNDING ELECTRODE 1 #4/0. MAIN SWITCHGEAR/PANELBOARD MAIN BONDING JUMPER SIZED PER 250-28(d) INSULATORS PLEXIGLAS SHIELD 3/8" x 5" x 20" PROVIDE IRREVERSIBLE COMPRESSION LUGS WITH BOLTS, WASHERS AND NUTS (TYPICAL FOR ALL) SEE NOTE 7 NOTES: 1. ALL GROUNDING SHALL COMPLY WITH ARTICLE NEC 250. WALL BRACKET (WITH MOUNTING SCREWS) SECURE TO STUDS OR PROVIDE BACK PLATE INSULATORS COPPER MAIN GROUND BUS (1/4" x 3"H x 18"L) MINIMUM PREDRILLED W/ HOLES ON 2" CENTERS HORIZONTALLY AND 1" VERTICALLY. MOUNT 18" A.F.F. EQUIPMENT JUMPER SIZED PER 250-1. 2. ALL GROUNDING CONDUCTORS AND BONDING JUMPERS SHALL BE CONNECTED BY EXOTHERMIC LDING, LISTED PRESSURE CONNECTORS, LISTED CLAMPS OR OTHER LISTED MEANS. 3. ALL CONDUCTORS SHALL BE COPPER. 4. ELECTRICALLY CONDUCTIVE MATERIALS, SUCH AS METAL WATER PIPING, AND STRUCTURAL STEEL SHALL BE BONDED TO THE MAIN MAIN GROUND BUS. 5. ALL GROUNDING CONDUCTORS AND BONDING JUMPERS SHALL BE ROUTED TO ENSURE SHORTEST POSSIBLE CONDUCTOR LENGTH. ALL METAL RACEWAYS AND ARMOR ENCLOSING A GROUNDING ELECTRODE CONDUCTOR SHALL BE BONDED AT EACH END AND TO ALL INTERVENING RACEWAYS, BOXES AND ENCLOSURES BETEN THE SERVICE EQUIPMENT AND THE GROUNDING ELECTRODE PER 250-92(a)(5). BONDING JUMPERS SHALL BE SAME SIZE AS GROUNDING ELECTRODE CONDUCTOR. CONCRETE ENCASED ELECTRODE (4/0 CU. UFER) EFFECTIVELY GROUNDED BUILDING STEEL METAL UNDERGROUND PIPE IN DIRECT CONTACT WITH THE EARTH FOR 10 FEET OR MORE AND ELECTRICALLY CONTINUOUS PER 250-30(a). BOND WITHIN 5 FEET ENTERING BUILDING PER 250-3(a)(3)(b) COPPER GROUNDING ELECTRODE CONDUCTOR 1 #4/0-1"C MINIMUM. CONDUCTOR AND METAL RACEWAYS SHALL BE ELECTRICALLY CONTINUOUS. INSTALL PER 250-64. PVC RACEWAY IS ACCEPTABLE. ALL CONNECTIONS TO GROUNDING ELECTRODES SHALL BE MADE BY EXOTHERMIC LD OR IRREVERSIBLE COMPRESSION LUGS PER 250-8. 6. THIS DETAIL IS ONLY DIAGRAMMATIC. 7. THE GROUNDING ELECTRODE CONDUCTORS SHALL BE LABELED AT THE MAIN GROUND BUS FOR IDENTIFICATION. 8. ALL CONNECTION TO GROUNDING ELECTRODES SHALL BE MADE BY EXOTHERMIC LD OR IRREVERSIBLE COMPRESSION LUGS PER NEC 250-8. 9. OTHER GROUNDING ELECTRODES SHALL BE PERMITTED INCLUDING BUT NOT LIMITED TO GROUND RODS, COUNTERPOISE GROUND LOOP, AND OTHER MADE ELECTRODES PER NEC 250-50 AND 250-52. 11 MAIN GROUNDING BUS DETAIL
PRESSIONAL 1 SITE PLAN - LIGHTING - ELECTRICAL 1/16" = 1'-0"
1 FIRST FLOOR - LIGHTING - ELECTRICAL PRESSIONAL 2 SECOND FLOOR - LIGHTING - ELECTRICAL
1 THIRD FLOOR - LIGHTING - ELECTRICAL PRESSIONAL 2 RO - LIGHTING - ELECTRICAL
1 PLAN - KING - ELECTRICAL 1/4" = 1'-0" PRESSIONAL PLAN - KING ADA - ELECTRICAL 1/4" = 1'-0" 2 1/4" = 1'-0" 3 PLAN - QUEEN/QUEEN - ELECTRICAL 4 PLAN - QUEEN/QUEEN ADA - ELECTRICAL 1/4" = 1'-0" 5 PLAN - KING SUITE - ELECTRICAL 1/4" = 1'-0" 6 PLAN - KING SUITE ADA - ELECTRICAL 1/4" = 1'-0"
1 FIRST FLOOR - POR & COMMUNICATIONS - ELECTRICAL PRESSIONAL 2 SECOND FLOOR - POR & COMMUNICATIONS - ELECTRICAL
1 THIRD FLOOR - POR & COMMUNICATIONS - ELECTRICAL PRESSIONAL 2 RO - POR & COMMUNICATIONS - ELECTRICAL
PRESSIONAL 1 ENLARGED LAUNDRY PLAN - POR 1/4" = 1'-0" 2 ENLARGED FOOD PREP PLAN - POR 1/4" = 1'-0"
1 FIRST FLOOR - FIRE ALARM & SECURITY - ELECTRICAL PRESSIONAL 2 SECOND FLOOR - FIRE ALARM & SECURITY - ELECTRICAL
1 THIRD FLOOR - FIRE ALARM & SECURITY - ELECTRICAL PRESSIONAL 2 RO - FIRE ALARM & SECURITY - ELECTRICAL