Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

Similar documents
SAC 100 Automatic Smoke Curtain System. - Specifier Information -

SMOKE AND FIRE CURTAINS

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT SPECIFICATION FireMaster Plus

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Technical Manual (European Standards)

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

PRODUCT SPECIFICATION FireMaster Plus Concertina

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

BLE Smoke and Fire Curtains

A REVOLUTIONARY APPROACH TO FIRE SAFETY

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

FIREMASTER CONCERTINA TM

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

Firetex steel fire shutters

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

FIRE & SMOKE CURTAINS

FIRE & SMOKE CURTAINS

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

Automatic Smoke & Fire Curtain Surveying Manual. Table of Contents. Before the Survey 2. Carrying out the Survey 2-3

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

SMART FIRE CURTAINS INTISI7. for invisible fire protection closures

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

WARNING FIRE DOOR CLOSING

PRODUCT SPECIFICATION FireMaster Concertina

SECTION XPRESS II INCLINED WHEELCHAIR PLATFORM LIFT. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

Smoke and Fire Curtains

Fire PROtec. Manual for automatic Fire Curtains. copyright by SIMON RWA Systeme GmbH Passau

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

Element C3.5 Means of Escape

WARRES No Page 1 of 27. Fire Resistance Test Generally In Accordance With BS 476: Part 22: 1987, Clause 5, on an Insulated Fabric Barrier

SECTION INCLINE WHEELCHAIR LIFTS. Display hidden notes to specifier by using Tools / Options / View / Hidden Text.

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

DORMA. Free Swing and Hold-open Solutions for Fire Doors. An alternative to Fire door keep shut

STANDARD FOR FIRE RATED ROLLING DOOR ASSEMBLIES

The EN54 Part 2 and 4 Fire System

Exclusively Curved. platinum STAIRLIFTS. platinum STAIRLIFTS

CENTRIFUGAL FANS user's manual. model VENTS VK.

ACTIVE FIRE CURTAINS INTISI7

An Overview of Extinguishing Systems for Computer Equipment

Module 7. Control of Smoke & Highlights of Code Requirements

FIA Guidance on Manual Call Point - Protection - False Alarm Mitigation

NG-9B NATURAL GAS ALARM

INTRODUCTION HOW DO RADIANT PANELS WORK? A common misconception, even among heating professionals, is that heat rises. In fact, hot air rises and cold

Fire detection and alarm

UBS1RF OPTICAL SMOKE ALARM EN 14604:2005/AC:2008 DOP:UBS1RF-001-V1

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

Loadstar AC/DC Systems

DAVITS INFORMATION & CERTIFICATION

1 P age w w w. s m o k e c o n t r o l. c o m. a u PROPRIETARY ITEM: FIBERHSIELD V AUTOMATIC OVERHEAD COILING TYPE FABRIC FIRE CURTAIN

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

Electromagnetic Locking Devices Performance Requirements

platinum STAIRLIFTS Exclusively Curved Stairlifts

Operation & Maintenance Manual

A. Section Masonry Assemblies: Anchor placement in masonry.

Uniclass L4223 CI/SfB (76.7) Epic D22. Roller Blind System

NFPA 80 Overview January 21, 2016

Loss Prevention Standard

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Fire Alarm Systems Design. incorporating Amendment No.2. a guide to BS5839. Part1:2002

The Application of Double-deck Inorganic Composite Fire Resisting Shutters in Constructional Engineering Bai-Xia ZHOU*

Model 3.6m. User Manual Original instructions

THE TINY LIGHTWEIGHT

Shops and Businesses Page 1/5

SANTA ROSA FIRE DEPARTMENT FIRE PREVENTION BUREAU PLAN REVIEW CHECKLIST

Standards in Security Shutters & Fire Shutters (UK & USA)

HeatExchangerSpares.com Ltd HRS Heat Exchangers Ltd HRS Hevac Ltd HRS Hevac Engineering Ltd HRS International Ltd HRS Investments Ltd

ROLLER SHUTTER SOLUTIONS AS UNIQUE AS YOUR VISION. RollUp Serranda (Pty) Limited 0860 ROLLUP ( )

Laboratory Fume Cupboards

Flame Shutter & Flame Curtain Price List

ROLL-DOWN FIRE DOORS AND SMOKE CURTAINS

STRETEX EXHIBITION STANDS: Buying Guide THE WAVE THE CURVE

USER MANUAL 10 YEAR LIFE SMOKE ALARM

Heating and cooling ceiling systems Suspended ceiling systems. Heating Cooling Fresh Air Clean Air

SECTION AIR DUCT ACCESSORIES

Hospitality. Emergency Lighting

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection

ASSA ABLOY Revolving Doors A full range to go full circle

Tabletop Cooler. Installation and User Guide. Swan Service Helpline For model: SR12010 (all colours) SR12010_IM.indd 1 17/02/ :56

Technical Information

Control Panels and Fire Detection Equipment

Telecab Residential Elevator OWNER S MANUAL

Catalogue. ActionpacEMSStandard. Electro Mechanical Control & Monitoring System.

THE IMPORTANCE OF FIRE DOORS

STA 21. record STA 21. record system 20 technologies for light to medium-heavy applications. record your global partner for entrance solutions

OPERATING AND MAINTENANCE MANUAL

WDC SERVICE SOLUTIONS LTD

Turbo steam iron steam/spray/shot

DS160/161 Request To Exit PIR sensors Installation Instructions

Transcription:

Smoke and Fire Curtains Performance Door sets for security and Fire resistant applications

Introduction The Fire & Smoke curtains are the latest in fire protection systems to be added to the Doors (UK) product range. We have the ability to offer the client a complete package from security to Fire & smoke containment. The dangers of fire, smoke and toxic fumes have become particularly evident in recent years as a result major tragedies involving the loss of life and damage to property. These dangers have greater scope in large Open Plan buildings where the intense heat of fire produces large volumes of lethal smoke and hot, combustible gases which travel at high speeds along ceilings and through ceiling voids. The speed of this wave of smoke and heat is such that people escaping from the fire are rapidly overtaken reducing visibility, increasing panic and leading to disorientation and death. However, Architectural and design considerations increasingly look for Open Plan buildings as the most aesthetic and ergonomic solution to Retail Store, Shopping Mall, Exhibition and Conference centres, Office and other high pedestrian traffic developments. The accepted solution to this dilemma is the Fire & Smoke curtains. Doors (U.K.) Ltd design, manufacture and install and a electrically operated roller which is fitted with a flameproof, woven glass textile curtain. This remains in the its retracted position, flush to the ceiling until it is activated by a signal from the main fire protection system. On receiving the signal the curtains descends to a preset level which forms a smoke compartment which enables any smoke to be extracted. When a smoke curtain is required to deploy in an emergency situation it is probable that the mains supply to the control panel may have already failed and that the cables linking the smoke curtains to the control panel might be damaged. Under these circumstances with no power available the smoke curtain will have to deploy by gravity. For this reason the Fire Curtain is always deployed by gravity and every time the system is tested it is a 100% confirmation of the fail safe operation of the system. A test in which a curtain is powered down under normal test conditions are only proving that they can deploy when powered. This does not confirm an ability to fail safe. Our Fire Curtain is a gravity fail safe Automatic Smoke Curtain system utilizing the latest in electronic technology. Advantages Fire resistant for up to 4 hours Total gravity fail safe system as standard Safe access and escape in the event of fire Versatile Lightweight compact construction enables easy installation without heavy structures significant radiant heat reduction with Enhanced fire and smoke containment

Operation Under normal conditions the curtain is retracted in the head box and is held in position by the electronics contained within a remote enclosure mounted on the motor end of the box. The bottom bar will be resting against the under side of the box or below the box if a stopping bar is installed, the stopping will then rest against the box. In the event of a fire condition or operation of the test key switch the group control panel removes the power to the curtain motors. The curtain descends in a controlled manner under the power of gravity and stops in the lower position when all the fabric is unwound from the roller. When the signal is reset the group control panel re connects the power to the motors which will retract the curtains to the up position. Should the mains power fail to the group control panel the supply is automatically switched to the integral standby battery. The curtain remains in the retracted position for 1 hour (fully loaded system). The curtain will remain fully operational until the battery low voltage cut off facility reads a voltage of 24v, the curtains will then descend under the power of gravity to the operational position. The Fire Curtain system allows the option of a 2 stage descent facility as smoke curtains are sometimes required to stop during descent to allow egress from buildings. A timer and relay circuit is installed within the GCP which is connected to a 24v brake housed in the motor assembly. The brake is operated at a pre determined time after descent to stop the curtain. After the required time limit the brake is de-energized and the curtain will descend to the full operational position under the power of gravity. Two stage descent facility The above panels include two timers which when set allow the smoke/fire curtain to be halted during descent. The curtain will descend for the preset run time and will then be stopped by the operation of the integral brake unit on the roller mechanism. When the chosen delay time has elapsed the brake unit will be de-energized and the curtain will continue on its descent. Both timers commence operation simultaneously, either upon receipt of a fire signal or if the GCP is placed in test mode. The run timer should be set to the time required for the curtain to descend to its delay position. The delay timer should be set to the required period of delay plus the run time. E.g. The curtain is to descend for a time of 10 seconds and then hold at this position for 15 seconds. 1) Set Run Timer to 10 seconds 2) Set Delay Timer to 10 seconds + 15 seconds = 25 seconds The curtain will retract as normal. Features Gravity fail safe operation Current limiting device incorporated, motor limit switches are not required Synchronized motor control circuitry, allowing variable speed control Back EMF controlled speed of descent, separate brake units are not required 24 v operation Control panels can control up to 6 curtain rollers Battery low voltage cut off facility, the curtains descend in a controlled manner.

Typical Standard Drawing

Specification Norfycurtain Fire Resistant Curtain. The fire curtain is deployed by gravity upon receipt of a fire signal or failure with the alarm system, which ensure a Fail safe system. The system has been tested to BS 476: Part 22 and has achieved a 4 hour rating. Dimensions: Electric operation - opening height up to 6000mm, opening width up to 6000mm for a single curtain. Widths above 6000mm will be manufactured from multiple roller with a 600mm overlap with a common bottom rail Curtain Constructed from 1, 2, 4 ½ Hour rated, Glass cloth fabric with a polymer coated to both sides, tested to BS 476 Parts 6,7, 20 and 22 Bottom Rail The lower edge of the curtain will incorporate a twin inverted powder coated mild steel angle which acts as a weight bar to enable the curtain to un wind upon receipt a fire signal. Performance: 4 hours fire resistance. Arrangement: Vertical Roller Curtain Shutter curtain: Glass cloth fabric with a polymer coated to both sides. Finish as delivered: Galvanised Steel Frame/ Guides: Bottom Rail: Twin inverted powder coated mild steel angle primer finished. Optional Finish: Powder coated finish to guides and bottom rail. Consult with for availability of alternative finishes. Side Guides Galvanised steel guides 100mm deep x 50mm width. Incorporating a fabric retaining system to prevent the fabric pulling out of the guides under pressure from the fire source. Electric Operation The motor assembly is responsible for driving and then stopping the curtain in the normal operational position via a current limiting circuit and providing a controlled speed of descent via a back EMF generation. Control Panel The group control panel can support up to 6 No fire curtains rollers. In normal operation the GCP provides a constant 24v AC supply to the roller under its control. Should a fire condition arise or the test key activated the GCP removes the 24v and the curtains descends under the gravity. Fire Resistance To BS 476: Part 22: 1987. 4 hours fire resistance Test No. 9753 Warrington Test Laboratory. Roller Assembly Enclosed within a 1.2mm galvanised steel head box. The barrel is manufacture from 76mm Diameter tube with 4mm wall, this give support to the curtain fabric and bottom rail. Endplates The curtain assembly is supported by mild steel endplates with mounting angles for fixing to the support structure Product reference: Norfycurtain Fire Resisting Curtain. Other requirements: Automatic Closing FDI Panel 2 Stage Closing Gravity Fail Safe Adjustable Descent Manufacturer:, Kingsforth Road, Thurcroft, Rotherham, South Yorkshire, S66 9HU. Tel: 01709 545 999 Fax: 01709 545 341 Email: mail@northerndoors.co.uk Website: www.northerndoors.co.uk

OTHER FIRE RESISTANT PRODUCTS NORFYDOR FIRE RESISTANT SHUTTER ESCALATOR FIRE RESISTANT SHUTTER WAYFINDER FIRE RESISTANT SHUTTER STRAIGHT SLIDING FIRE DOOR SLIDING FOLDING FIRE RESISTANT DOUBLE STEEL HINGED SINGLE STEEL HINGED LEAF AND HALF STEEL HINGED