FIRE & SMOKE CURTAINS

Similar documents
FIRE & SMOKE CURTAINS

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT CATALOGUE ACTIVE FIRE AND SMOKE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FIREMASTER CONCERTINA TM

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

FireMaster. The Fire Curtain Barrier WITHOUT CORNER POSTS. Inspiring design, maximising floor space and increasing income.

ACTIVE FIRE CURTAIN BARRIER FOR DOMESTIC & COMMERCIAL APPLICATIONS

FIREMASTER PLUS 2 TENABLE ZONE / HEAT PROTECTION ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

SMOKESTOP evacu8 ACTIVE SMOKE BARRIERS WITH EGRESS LEADING THE WAY IN FIRE PROTECTION

FIREMASTER ACTIVE FIRE CURTAIN BARRIER ASSEMBLIES LEADING THE WAY IN FIRE PROTECTION

PRODUCT SPECIFICATION FireMaster Plus Concertina

DATASHEET VARIOSPEED 6 EMERGENCY RETRACT UNIT CONTROLS AT MOTOR (VS6-ERU-CAM)

PRODUCT SPECIFICATION FireMaster Plus

In accordance with: Period of Fire Resistance: 180 minutes (3 hours) integrity (single) 120 minutes (2 hours) integrity (overlapped)

Maximum Dimensions: Approved for spans unlimited in width, heights up to 10.5 m ( in), minimum panel overlap 400 mm (15.

PRODUCT SPECIFICATION FireMaster NVS Horizontal Simplex

AUTOMATIC FIRE CURTAIN FIRE CURTAIN FM 1

PRODUCT SPECIFICATION FireMaster Concertina

SMOKE & FIRE THE LEADING EDGE IN. Smoke & Fire Curtains

SAC 100 Automatic Smoke Curtain System. - Specifier Information -

CI/Sfb ( ) smoke stop. Smoke Barriers for all applications... Swiss Re London. Lane Crawford Singapore. London.

Smoke and Fire Curtains. Performance Door sets for security and Fire resistant applications. Northern Doors (UK) Ltd

A REVOLUTIONARY APPROACH TO FIRE SAFETY

FIBERSHIELD V FIREIRE CURTAINSURTAINS (COMPACT FLEXIBLE AUTOMATIC FIRE BARRIERS)

ACTIVE FIRE CURTAINS INTISI7

Technical Manual (European Standards)

CI/SfB (68.5) February Intelligent security and fire protection. SecureFire S e c

Retail solutions by Tenos. Value engineered fire safety solutions for landmark retail developments.

REPORT HOLDER: SMOKE GUARD, INC. 287 NORTH MAPLE GROVE ROAD BOISE, IDAHO EVALUATION SUBJECT:

Won-Door FireGuard T H E P E R F E C T F I T I N A V A R I E T Y O F A P P L I C A T I O N S

Smoke and Fire Curtains

Firetex steel fire shutters

Best Practice BS 3621: 2007 BS 8621: 2007 BS 10621: 2007 dhf

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

PASSIVE FIRE PROTECTION FTI-MARNEROS LTD

1 P a g e w w w. s m o k e c o n t r o l. c o m. a u

Hardware for Sliding Doors & Folding Doors

Building Services Brochure

SECTION ELEVATOR FIRE RATED SMOKE CONTAINMENT SYSTEM

V3 Intelligent Damper Control and Monitoring System

Safegard V4 Bespoke Intelligent Damper Control and Monitoring System

fire resistance testing

Fire and Smoke Curtains

Panic and Emergency Exit Devices

Mechanical Smoke Extract Shaft Systems

Advanced FireAlarm Panel 1-4Loop

BLE Smoke and Fire Curtains

Prescriptive Requirement for Smoke Control

Actionpac LNS3 Intelligent Damper Control and Monitoring System

Fire detection and alarm

THE LEADING EDGE IN Smoke & Fire Curtains

WORLDWIDE VENTILATION SOLUTIONS

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

THE SMOKE AND ACCESS SPECIALISTS. Compliance without compromise

1 P a g e w w w. s m o k e c o n t r o l. c o. nz

Fire and Security Products and Services

Schueco Fire and Smoke Protection Systems

Forming the Future. Changing spaces with architectural cladding and interior theming

Reliably Advanced Extinguishing Control

Operation & Maintenance Manual

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

About Smart. Expand your horizons with our high-quality sliding and slide-folding doors

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Pocket guide to. Fire Alarm Systems Design BS Standard

Loss Prevention Standards

Actionpac 60/120 (LNS Standard)

Section 2 - Applications - General. Section 2A - FD30 Strebord 35+, 38+, 44 & Superpan with MDF & Wood Frames

YOUR SINGLE SOURCE FOR EMERGENCY RESPONSE CLOSURE PRODUCTS

ROCHÉ SYSTEMS. Designer, manufacturer & installer of high quality physical security, awning & glass room solutions. COMMERCIAL

Controlled Door Closing Devices

technical specification smoke venting systems

Range brochure. Beam detection. others look up to.

Total peace of mind. Services. Services. Total peace of mind

Advanced Air. Hard Wired Damper Control Panels. Systems 10, 11, & 12. Hard-Wired Systems. Bespoke Systems Available. Value Engineered Solutions

Low Voltage Catalogue_Final ai 11/8/09 11:37:27 AM BICC 1 BICC Final Brochure-NEW.indd 1 7/5/10 3:02 PM

FIRE DOORS - GENERAL UCL OVERVIEW AND REQUIREMENTS

HART XL High Sensitivity Smoke Detection

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

Fire Door Maintenance Guide.

Remote Control Garage Doors

Electromagnetic Locking Devices

Hazardous Area Portable Fan Heater The Bulldog

best practice guide BS EN 12320: 2001 Padlocks & padlock fittings to in association with Permission to reproduce extracts from BS EN 12320: 2001

Best practice guide. Hardware for sliding doors and folding doors to BS EN in association with. Association of Building Hardware Manufacturers

ROLLER SHUTTER SOLUTIONS AS UNIQUE AS YOUR VISION. RollUp Serranda (Pty) Limited 0860 ROLLUP ( )

Firefighting operations on fire alarm panels F5-04 GD

Fire Rated Door Assemblies: Compliant Designs

Safety Instrumented Fire & Gas Systems

Technical reference Reference & design

Life Safety Damper Installation ASHRAE St Louis Chapter Feb. 9,2015. Peter McDonnell, PE, LEED AP BD+C McClure Engineering

UCL PRINCIPAL CONTRACTOR SITE FIRE SAFETY RISK REVIEW & MITIGATION MEASURES

/WON BuyLine 3726 WON-DOOR. FireGuard. The ORIGINAL horizontal sliding accordion fire door.

A Guide To BS Understanding the selection, spacing and siting of detectors

White Paper. Keeping up with compliance: Escape doors standards. The global leader in door opening solutions

General Principles of Smoke Control

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Smoke Vent Control Panel PCB4 V4 Installation Manual

GRUNDFOS FIRE PUMP SYSTEMS PEERLESS ENGINEERED SYSTEMS LISTED

WORKSHEET 2-1 THE MANITOBA RESIDENTIAL OCCUPANCY FIRE RISK INDEX FIRE SAFETY PARAMETER VALUES

security WHAT MAKES US DIFFERENT? We Place A Huge Importance On Integrity.

FIRE DOOR. AlarmGard & FireGard. Preferred door solutions.

Transcription:

FIRE & SMOKE CURTAINS APPLICATIONS FOR FIRE AND SMOKE CURTAINS AND THE PRODUCT RANGE AVAILABLE WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION

TESTING AND STANDARDS COMPANY PROFILE COOPERS FIRE Coopers Fire operates from two factories in the UK, the main office and factory on the south coast in Havant and one in Elland, West Yorkshire. Coopers Fire offer third party certified product design, manufacture, installation, commissioning and on-going servicing of fire and smoke barriers. Coopers Fire offer third party certified product design, manufacture, installation, commissioning and on-going servicing of fire and smoke barriers. With a long established history, Coopers Fire are represented in over 40 overseas territories through a distributor network The Engineering Department is fully equipped with 3D and 2D facilities and can provide customised services right from concept and design stage to completion. Coopers Fire offers technical expertise, with a number of its experts extensively involved in developing ISO, CEN and BS product standards. Unlike other suppliers, Coopers Fire pride themselves on innovation and bespoke solutions which are supported by numerous internationally accredited Independent Third Party Certification Schemes for Product, Installation and Service where applicable. Coopers Fire commitment to life safety is best expressed through dedication to ensuring that the fire and smoke curtains manufactured meet the highest international standards. Coopers Fire test and manufacture every fire and smoke curtain in accordance with the toughest of internationally recognised accreditations, which are then independently third party certified, instilling clients with confidence in fire protection equipment that they can trust. Coopers Fire are the original patentees of the electromechanical fail safe system, which set the benchmark for active smoke and fire barriers worldwide, and help to continue to remain a market leader using patented and proprietary technology. Coopers Fire offer an unparalleled range of vertical and horizontal fire and smoke curtain barrier systems that are tested extensively in many different countries to many international standards meeting a wide range of regulation. COOPERS FIRE IS A SPECIALIST MANUFACTURER OF SMOKE AND FIRE CURTAIN BARRIER SYSTEMS COMPANY HISTORY Coopers Fire was originally a family business manufacturing blinds and shutters dating back to 1874. The automatic fire screen with gravity fail-safe drive system was invented and patented by Coopers Fire in 1983 and sparked a generation of smoke and fire barriers. Now an industry norm, active smoke and fire barriers are available worldwide. Coopers Fire operate with an ISO 9001 Quality Management System and ISO 14001 Environmental Management System. The product range is quality assured and built for longevity and on-going service and maintenance. 2 W W W. C O O PER S F I R E.COM COOPERS INTERNATIONAL LANDMARKS Continuous research and development has resulted in Coopers Fire always being first in their industry to comply with new standards. It was the first to comply with BS 7346-3 and CE Mark to EN 12101-1 for smoke barriers and with BSI PAS 121 and now BS 8524 for fire curtain barriers. Coopers Fire was bought by the Lowe & Fletcher Group in 2014, who are a fifth generation family owned industrial business which was founded in 1889. Many prestigious international landmark buildings are protected by Coopers Fire smoke and fire curtains. Some of the iconic buildings in which Coopers Fire products are installed include the Sydney Opera House; The Louvre in Abu Dhabi; Royal Palaces at Buckingham Windsor, and St. James; London s iconic buildings like The Shard; The British Museum and The Gherkin and large shopping malls like The Mall of the Emirates and the Dubai Mall. Coopers Fire have curtains in International Airports such as Sydney; Brisbane; Dulles, Heathrow; Gatwick; Stansted; Ataturk; Johannesburg; Düsseldorf; Chek Lap Kok; and Dubai. Coopers Fire have also installed fire and smoke curtains in commercial buildings, offices and retail stores for brands such as Apple; Adidas; Google; McDonald s; Selfridges; Fortnum and Mason and Facebook. LEA D ING THE WAY IN FIR E PR OT E C T ION 3

APPLICATIONS FIRE AND SMOKE CURTAINS APPLICATIONS FIRE AND SMOKE CURTAINS Coopers Fire have developed a wide range of fire and smoke curtains to protect every type of building application. From protecting means of escape and boundary protection to providing a building with a system that offers effective fire and smoke compartmentation. Fire and Smoke curtains offer various solutions to architects, engineers, consultants and specifiers providing the ability to design complex buildings that adhere to fire regulations and offer protection against fire or smoke. When specifying a fire or smoke curtain system, it is essential to consider the whole package from quality, performance, installation and maintenance to after sales care. Coopers Fire offers third party certificated products as well as third party accredited installation and specialist after care packages, tailored to your specific requirements and application. Commitment to life safety has led Coopers Fire to develop a wide range of fire and smoke curtain barrier assemblies fully tested to BS EN and UL standards and approved to protect various applications across a wide spectrum of building types such as retail, hospitals, commercial, airports and domestic. ATRIUM, LOBBIES & RECEPTIONS OPENINGS IN WALLS COMPARTMENTATION LIFTS AND LIFT LOBBIES Prevent the spread of smoke and fire from one to floor to another in an atrium with Coopers Fire Horizontal or Concertina curtains or protect lobbies and receptions using Vertical fire and smoke curtains. Coopers Fire fire curtains can be used to replace non-load bearing walls and fire rated glazing offering open plan designs that still meet fire regulations. Coopers Fire full range of fire and smoke curtains can be used to create compartments to contain fire and smoke and prevent it from spreading. The product range is used particularly in this instance in large open spaces in buildings. Coopers Fire knowledge of the regulations protecting lifts and lift lobbies has led to the development of a range of Vertical fire curtains with smoke control approved to protect the spread of fire and smoke through lift shafts. EGRESS & CORRIDOR SEPARATION BOUNDARY PROTECTION STAIRS AND ESCALATORS PROTECTED MEANS OF ESCAPE Protect escape routes for mass evacuation. The evacu8 smoke curtain allows egress through a compartment that contains smoke. It offers the capability to split deployment to encourage safe evacuation psychology where assemblies cross potential escape routes. Coopers Fire fire curtains are an approved alternative to fire shutters, fire rated glazing and firewalls whilst protecting windows from channeling fire and preventing the spread of fire from one building to the next. Open up stairwells or protect escalators by using Vertical or Concertina fire and smoke curtains. The Concertina product has been used to fully encapsulate stairs or escalators to allow open plan designs, replacing fire doors and lobbies. Coopers Fire commitment to advancing fire fabric technology has led us to develop a range of insulating zone fire curtains that provide architects and fire engineers with a non-invasive, protected means of escape, in accordance with fire regulations. 4 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 5

PRODUCT MATRIX FIRE AND SMOKE CURTAINS PRODUCT MATRIX FIRE AND SMOKE CURTAINS These tables will help assist you with the type of fire or smoke curtain product required. These tables will help assist you with the type of fire or smoke curtain product required. BS 8524-1 FIRE CURTAINS PRODUCT NAME ORIENTATION WIDTH DROP FIRE RESISTANCE OR CLASSIFICATION SMOKE CONTROL Vertical - Single Roller 5m 8m E180 EW30 Yes* Vertical - Overlapping Rollers Vertical - Overlapping Rollers 27.5m 5m E60 EW60 No 8m 8m E120 EW60 No PLUS 2 Vertical - Single Roller 5m 8m E180 EW60 Yes* PLUS 2 Vertical - Wide Single Roller 20m 4m E180 EW60 Yes* Concertina - Open Unlimited 5m E180 EW30 No Concertina - Open Unlimited 8m E120 EW30 No Concertina - Closed Unlimited 5m E240 EW30 No Concertina - Closed Unlimited 8m E120 EW30 No VII FIRE Vertical - Single Roller 4m 4m E120 EW30 Yes* VII FIRE izone Vertical - Single Roller 4m 4m E180 EW60 Yes* * Approved to BS EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware. Smoke control test for door and shutter assemblies. BS EN 1634-1 FIRE CURTAINS PRODUCT NAME ORIENTATION WIDTH DROP FIRE RESISTANCE OR CLASSIFICATION SMOKE CONTROL Vertical - Single Roller 7m 8m E120 EW30 Yes* Vertical - Single Roller 7m 7m E180 EW30 Yes* PLUS 2 PLUS 2 Vertical - Overlapping Rollers Vertical - Single/ Overlapping Rollers Vertical - Single Roller/ Wide Single Roller Vertical - Single Roller/ Wide Single Roller Unlimited 6m E120 EW60 No Unlimited 8m E120 EW30 No 7m 5m E120 EW60 Yes* 7m 4m E180 EW60 Yes* MARINE Vertical - Single Roller 2.692m 2.4m A-0 No HORIZONTAL Horizontal - Simplex 5m 7m E120 EW30 No HORIZONTAL Horizontal - Duplex 5m 14m E120 EW30 No PLUS HORIZONTAL PLUS HORIZONTAL SUPERPLUS Horizontal - Simplex 5m 7m E120 EW60 No Horizontal - Duplex 5m 14m E120 EW60 No Vertical - Single/ Overlapping Rollers On Request 3m EI30 (EI120 through assessment) * Approved to BS EN 1634-3, Fire resistance and smoke control tests for door and shutter assemblies, openable windows and elements of building hardware. Smoke control test for door and shutter assemblies. No UL TESTED FIRE AND DRAFT CURTAINS BS EN 12101 SMOKE CURTAINS PRODUCT NAME EGRESS DRAFT CURTAIN EGRESS ORIENTATION Vertical - Single/ Overlapping Rollers Vertical - Single/Wide Single Roller WIDTH DROP FIRE RESISTANCE OR CLASSIFICATION SMOKE CONTROL Unlimited 8m 180 mins Yes 18m 7m 180 mins Yes Vertical - Open/Closed Unlimited 8m 180 mins No Concertina - Single/ Overlapping Rollers Vertical - Single/Wide Single Roller Unlimited 8m N/A Yes 18m 7m N/A Yes PRODUCT NAME ORIENTATION WIDTH DROP FIRE RESISTANCE OR CLASSIFICATION Vertical - Single Roller 6m 8m D600A Vertical - Overlapping Rollers Unlimited 10.5m D600A Vertical - Single Roller 6m 8m DH60 EVACU8 Vertical - Overlapping Rollers Vertical - Side by Side Overlapping Unlimited 10.5m DH60 Unlimited 6.7m D600A Vertical - evacu8 Unlimited 6.7m D600A Concertina - Open/ Closed Unlimited 6m DH60/D60 6 LEADING THE WAY IN FIRE PROTECTION 7

VERTICAL FIRE AND SMOKE CURTAINS VERTICAL FIRE AND SMOKE CURTAINS Coopers Fire manufacture a range of active Vertical fire and smoke curtains that can be installed for various applications. Vertical fire and smoke curtains are designed to prevent the spread of fire and smoke in accordance with BS 8524-1:2013 and UL 10D for fire curtains and BS EN 12101 for smoke curtains. Vertical fire curtains are used to prevent the spread of fire within a building and can be discreetly installed to be hidden from view until required. All Coopers Fire vertical active fire curtains use the Total Gravity Fail-Safe (TGFS) system which ensures the fire curtains will activate even if there is a total power failure or short circuit. 1 2 Vertical smoke curtains are used to prevent the spread of smoke and/or work as part of a smoke control system to channel smoke for extraction from a building. Smoke curtains can also be discreetly installed and activate using the Total Gravity Fail-Safe system. Coopers Fire active Vertical fire and smoke curtains can use various fire-resistant fabrics, depending on the application, fixed to a roller and housed in a steel headbox. The curtains remain invisibly retracted until activated by an alarm or detector signal, at which time they descend safely to their operational position. Fire and smoke curtains are available in various widths and drops (see the product matrix on pages 6 and 7) and have been tested to BS EN and UL standards. Coopers Fire manufacture a unique intumescent fabric that can offer protection from radiant heat and be used where protected means of escape is required. 4 A TYPICAL VERTICAL FIRE CURTAIN 3 Single Roller Assembly - used for narrower width curtains where one roller is required 1 Headbox 2 Fabric Curtain 3 Guide Assembly 4 Bottom Bar A TYPICAL VERTICAL SMOKE CURTAIN PRODUCT FEATURES Fire Curtains compliant to BS 8524-1: 2013 and assessed in accordance with BS 476-22.8:1987 and BS EN 1634-1:2008. Tested to UL Standards 10B, 10C, 10D,1784 and NFPA 252 Smoke Curtains CE marked and classified to DH60 or D 600 A and assessed in accordance with BS EN 12101-01:2005+A1:2006. Certified for smoke and draft rating in accordance to UL 1784 Standard Unlimited widths and bespoke engineered products available Third Party Approved by IFC Certification, Warrington Certification and other certification bodies Integrity, Radiance and Insulated vertical fire curtains available Overlapping / Multiple Roller Assembly - used for wider curtains (unlimited) where multiple rollers are required 8 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 9

HORIZONTAL FIRE CURTAINS HORIZONTAL FIRE CURTAINS Coopers Fire active FireMaster Horizontal fire curtains offer an alternative way to close off stairwells and atria. Horizontal curtains can be used instead of installing fire rated glazing or non-load bearing ceilings therefore creating open plan areas. All Coopers Fire Horizontal fire curtains have No Visible Supports (NVS TM ) which means the unique design allows the curtain to run under tension in a guide down each side, leaving the opening free from any supports for the curtain once installed. There are three types of the FireMaster Horizontal fire curtain, the Mini Simplex, Simplex and Duplex. Both the Mini Simplex and Simplex close from one end to the other, whereas the Duplex is used for much larger areas and closes from each end of a void to meet and close in the middle. Active Horizontal fire curtains comprise of technologically advanced fire resistant fabric encased in a compact steel housing. The fire curtain will remain invisibly retracted until activated by an alarm or detector signal, at which time they close safely to their fire operational position. Horizontal fire curtains will stop and control the spread of fire between floors in a building. To be compliant, Fire Barriers must have a dual power supply fitted as standard. The curtain closes with mains or emergency power using a low voltage drive system. The FireMaster Horizontal is designed to prevent the spread of fire in the horizontal plane and available in a range of sizes. 1 2 3 Curtain Direction MINI SIMPLEX TM (SINGLE BARRIER ASSEMBLY) SIMPLEX TM (SINGLE BARRIER ASSEMBLY) 4 1 4 1 Fabric Roller Headbox 2 Fabric Curtain 3 Guide Assembly 4 Cable Roller Headbox 5 Finished Floor Suitable for smaller, narrower openings in domestic dwellings and for skylights etc. 5 Suitable for smaller openings and skylights etc. PRODUCT FEATURES Fire Curtains compliant to and assessed in accordance with BS EN 1634-1:2008 Alternative to fire rated glazing and non-load bearing ceilings Third Party Approved by IFC Certification, Warrington Certification and other certification bodies Integrity and Radiance fire curtains available DUPLEX TM (DOUBLE CURTAIN ASSEMBLY) Suitable for large openings including expansive atria. Complete closure in half the time. 10 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 11

TM FIRE AND SMOKE CURTAINS TM FIRE AND SMOKE CURTAINS The innovative active Concertina fire and smoke curtain offers greater flexibility to designers to create open plan buildings that remove the requirement for columns or corner posts and intrusive ceiling interfaces that may be required for alternative fire and smoke safety products. The unique features of the FireMaster and SmokeStop Concertina allow it to be used in place of traditional fire and smoke control elements, allowing architects, fire engineers and specifiers to create open plan designs which meet all the requirements of a building s fire and smoke control strategy. The Concertina can be configured in a variety of bespoke sizes and shapes, like a square or circle and an arc or trapezoid. In fact, the Concertina can be configured in most shapes in unlimited spans. 1 3 Concertina fire and smoke curtains are installed to prevent the spread of fire and smoke and are often used to close off stairs and escalators providing architects, consultants and specifiers a whole new approach to building design. Coopers Fire active Concertina fire and smoke curtain can use various fire-resistant fabrics, depending on the application. The fabric is uniquely folded and housed in a steel headbox. The curtain remains invisibly retracted until activated by an alarm or detector signal, at which time they descend safely to their operational position. The Concertina product benefits from the Total Gravity Fail- Safe system which ensures the curtain will deploy safely even in the event of a total power failure or short circuit. 2 BESPOKE PRODUCT CONFIGURATIONS 4 5 1 Headbox 2 Bottom Tray 3 Fabric Curtain 4 Corner Fold Fabric Developed to provide a bespoke alternative to fixed non-loadbearing walls, partitions and fire shutters, the Concertina can be used as part of a fire engineering solution in commercial and industrial applications such as airports, shopping centres, offices and hotels or where the need for maintaining open areas for access is vital. 5 Floor DIFFERENT TYPES 1. Square (Closed) 2. Faceted Curve (Open) 3. L Shaped Corner (Open) 4. Trapezoid (Closed) 5. Multifaceted (Circular Closed) 1. 2. PRODUCT FEATURES Concertina fire curtain compliant to BS 8524-1: 2013 and assessed in accordance with BS EN 1634-1:2008 and BS EN 13501 2:2007+A1:2009. Tested to UL Standards 10B, 10C, 10D,1784 and NFPA 252 Concertina smoke curtain is CE marked and classified to DH60 or D 600 A and assessed in accordance with BS EN 12101-01:2005+A1:2006 Unlimited widths and bespoke engineered products available Third Party Approved by IFC Certification, Warrington Certification and other certification bodies Bespoke shapes achievable to allow open plan designs meet fire regulations 3. 4. 5. 12 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 13

Vii FIRE COMPACT FIRE CURTAINS Vii FIRE COMPACT FIRE CURTAINS Coopers Fire Vii Fire compact vertical fire curtain provides the means to help create modern, open plan living environments in domestic homes, which are compliant with stringent fire regulations without compromising design. Sympathetic to interior aesthetics, the Vii Fire fire curtain barrier will remain hidden until deployed. It is used to replace non-loadbearing walls, fire doors and uninsulated glazing. The Vii Fire FM product is designed as a barrier to prevent the spread of fire in accordance with BS EN 1634-1:2008 and BS 8524-1:2013 and is the ideal solution for small holes in fire walls. 1 The Vii Fire product range is limited to a maximum width of 4 metres and a maximum drop of 4 metres. This range of products was introduced for use in domestic homes and areas of buildings where a compact headbox is required. 2 4 3 1 Headbox 2 Fabric Curtain 3 Side Guide Assembly 4 Smoke Seal The full Vii Fire range is easy for a competent person to install and is the first and only plug and play fire curtain system. This product is also aimed at kitchen serveries and portable cabins. Being extremely compact, it remains completely invisible until required. Vii Fire active fire curtains can use various fire-resistant fabrics, depending on the application. The fabric is fixed to a roller which is housed in a steel headbox. The curtains remain invisibly retracted until activated by an alarm or detector signal, at which time they descend safely to their operational position. The Vii Fire uses the Total Gravity Fail- Safe system ensuring the fire curtain will deploy safely even if there is total power failure or a short circuit. ACTIVE FIRE BARRIERS FOR THE DOMESTIC HOME If protecting a means of escape, an insulating zone is required to protect passing occupants from radiating heat. Coopers Fire Vii Fire i-zone is approved to BS 8524-1:2013 and will achieve radiated heat as low as 10kW/m² after 60 minutes. BEFORE 5 6 5 Bottom Bar 6 Finished Floor The Vii Fire izone utilises a unique intumescent fabric manufactured by Coopers Fire that can offer protection from radiant heat and can be used where protected means of escape is required. PRODUCT FEATURES AFTER Fire Curtains compliant to BS 8524-1: 2013 and assessed in accordance with BS 476-22.8:1987 and BS EN 1634-1:2008 Maximum width of 4m and maximum drop of 4m Third Party Approved by IFC Certification, Warrington Certification and other certification bodies Integrity and Radiance vertical fire curtains available 14 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 15

CONTROL OPTIONS VARIOSPEED 6 CONTROLS PLUG AND PLAY MONO MK5 CONTROL The Variospeed 6 system is used for Smoke and Fire Curtains. It uses 24Vdc permanent magnet electrical motors with an internal 24Vdc electromagnetic brake, as standard. When the Smoke or Fire curtain(s) are fully retracted, the internal electromagnetic brake is powered, keeping the Smoke or Fire curtain(s) in their retracted position. Power to the motor is completely isolated, prolonging the life of the motor and maintaining the manufacturers supply warranty. The Mono Control Unit is a compact single curtain controller with a complete range of incorporated ancillary control options. The system is completely plug and play, which means all wiring terminations can be connected quickly and efficiently, reducing installation times and complexity. The system also incorporates a self-test facility, enabling the system to monitor it s performance and maintaining a safe system. The motors include built in short circuit and open circuit protection, meaning the curtains will deploy under Total Controlled Gravity Fail-Safe at a descent rate compliant with standards BS EN 12101 and BS 8524 even if the motor wires are severed, i.e. shorted together or disconnected from the Motor Control Card (MCC). In the event of an alarm activation the electromagnetic brake will de-energise and the Smoke or Fire curtain(s) will immediately deploy to their Fire Operational Position under Gravity Fail-Safe. VARIOSPEED 6 CONTROLS AT MOTOR (CAM) 230Vac 50Hz Dedicated Supply Motor Control Unit Tubular Motor 24Vdc Signal 24Vdc Motor Cable Fire Alarm Normally closed, volt-free contacts Power Supply Unit GRAVITY FAIL-SAFE If there is a mains power failure the Smoke or Fire curtain(s) will be held in the retracted position for 30 minutes (adjustable) under Battery Backup (BBU) before deploying to their Fire Operational Position (FOP). If an alarm activation is received during a mains power failure, the curtain(s) will immediately deploy to their FOP. The Smoke or Fire curtain(s) will descend under total and controlled Gravity Fail-Safe. PRODUCT BENEFITS 230Vac 50Hz Dedicated Supply Tubular Motor Fire Alarm Normally closed, volt-free contacts Mono Control Unit VARIOSPEED 6 CONTROLS GROUPED (CG) Tubular Motor 230Vac 50Hz Dedicated Supply 24Vdc Motor Supply from Coopers PSU Fire Alarm Normally closed, volt-free contacts Power Supply Unit Can be connected to BMS for monitoring of system Up to 20 fire or smoke curtain rollers from one Power Supply Unit (PSU) Adjustable electronic descent speeds Motor protected from short circuits or open circuits 24Vdc motors with internal electromagnetic brakes as standard Adjustable battery backup Multiple alarm inputs and outputs Low power consumption PRODUCT FEATURES Low power consumption Small, compact enclosure Complete plug and play wiring and terminations, simple to connect 24Vdc motors with internal electromagnetic brakes as standard Adjustable electronic descent speeds Motor protected from short circuits or open circuits Adjustable battery backup Enabled for Self-Test Programmable and adjustable Split Drop Delay Programmable and adjustable Dual Drop Programmable Timed Emergency Retract Fireman s Override Fault and Event Log 16 WWW.COOPERSFIRE.COM LEADING THE WAY IN FIRE PROTECTION 17

OPTIONAL EXTRAS VARIOSPEED 6 CONTROLS SERVICE AND MAINTENANCE Light Warning Unit Voice Warning Unit Heat Detector Smoke Detector Your fire and smoke curtains are part of the building s life support system; we ll make sure that they continue to protect your building and its occupants from fire and smoke. No matter the type of building or the make and model of the fire curtain or smoke curtain, a Coopers Fire service agreement provides peace of mind as you can be assured of the performance of your system at all times and can avoid any unexpected and costly repairs. Coopers Fire service engineers are the only independently approved service team qualified to conduct the servicing of fire and smoke control curtains. Test / Reset Switch Emergency Retract Buttons Building Management System (BMS) Interface Adjustable Split Drop and Half Drop Enabled Safety Edge / Bump Stop PLANNED SERVICE IS AVAILABLE FOR COOPERS FIRE LIFE SAFETY EQUIPMENT. BENEFITS OF BEING A SERVICE CUSTOMER OPTIONAL EXTRAS MATRIX Optional Extras MONO / ERU Control Panel Type Light Warning Units Voice Warning Units Heat Detector / Smoke Detector û Test / Reset Switch Emergency Retract Push Buttons û BBU BMS Interface Adjustable Split Drop and Half Drop Enabled Safety Edge / Bump Stop MONO - Control Panel for single curtain i.e. one roller ERU - Emergency Retract Unit BBU - Battery Backup Unit See the table below for use of optional extras available. Datasheet Reference Visit Coopers Fire website at www.coopersfire.com Customer Service Adviser A member of the service team will oversee your account Technical Support Access to technical teams and engineers Scheduled Maintenance Visits Two pre-planned visits to ensure compliance with relevant British Standards Guaranteed Response Times For Emergency Calls 24hr response Pre-agreed Spending Limits Avoid costly return visits and delays by utilising van stocks On Site Training Provided during engineers visits No Up Front Payments Setting up an account ensures no delay to repairs Service Customer Call-Out Only 18 LEADING THE WAY IN FIRE PROTECTION 19

For information, to get a quote or to book a CPD workshop Please call: +44 (0)2392 454 405 or E-mail: info@coopersfire.com WWW.COOPERSFIRE.COM Coopers Fire Ltd, Edward House, Penner Road, Havant, Hampshire, PO9 1QZ United Kingdom Phone: +44 (0)2392 454 405 Fax: +44 (0)2392 492 732 Email: info@coopersfire.com Web: www.coopersfire.com Coopers Fire Ltd has a policy of continuous product improvement. As such we reserve the right to change design and specifications without prior notice. Please check our website for the latest information. Coopers Fire Ltd. All content and products are copyright of Coopers Fire Ltd. Registered in England Number: 2010274. Multiple patents granted and pending. Series 2 v06 May 2018 L&F A Lowe & Fletcher Group Company LEADING THE WAY IN FIRE PROTECTION